Indian Tenders

Tender Notice

TDR 55074591
Tendering Authority Ajmer Vidyut Vitran Nigam Limited
Tender No AJD/SE/TW/LRC/TN-463 Lot-I
Tender ID 2026_AVVNL_551499_1
Tender Brief Tender For Erection Of 33Kv Line Interconnection Work For (Jawaja 33Kv Line, Kabra 33Kv Line , Rajiyawas 33Kv Line & Shekhawas 33Kv Line) In Jawaja (O&M) Sub-Division Of Ajmer Discom.
City Ajmer
State Rajasthan
Document Fees INR 2950 /-
EMD INR 112000.0 /-
Tender Value INR 56 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Erection Of 33Kv Line Interconnection Work For (Jawaja 33Kv Line, Kabra 33Kv Line , Rajiyawas 33Kv Line & Shekhawas 33Kv Line) In Jawaja (O&M) Sub-Division Of Ajmer Discom.

Key Dates

Publish Date 13-04-2026
Last Date of Bid Submission 27-04-2026
Tender Opening Date 28-04-2026

Contact Information

Company Name Ajmer Vidyut Vitran Nigam Limited
Contact Person SE TW AVVNL AJMER
Address ROOM NO. 216 VIDHYUT BHAWAN PANCHSHEEL AVVNL AJMER

BOQ Items

Name of Work:- Erection of 33KV Line Interconnection work for (Jawaja 33KV Line, Kabra 33KV Line , Rajiyawas 33KV Line & Shekhawas 33KV Line) in Jawaja (O&M) Sub-division of Ajmer Discom.
Sl. No. Item Description
133 KV Line work Annexure -B
2Conducting route survey as per approved route map and pegging of route with tee off point section point & double pole locations.
3Trimming of tree branches/plants and preparing route approchases for proposed line.
4Excavation of pit in soil (ordinary) to erect various supports and stay sets including stacking of excavated soil from the edge of excavation.
5(A) Height of poles/R.S.Joist/M.S. Rail Size of pit
69 Mtr/ 1.2mx0.6mx1.50 m deep
7(B) Lattice Tower /Size of pit
811.4/10.8 Mtr/ 1.5mx1.5m x1.80 m deep
912.8/12.6 Mtr/ 1.5mx1.5m x2.10 m deep
10(C)Stay set/Depth of pit
118'x 3/4\\" -0.75x0.5x1.6 m
12Excavation of pit in Hard soil
13(A) Height of poles/R.S.Joist/M.S. Rail Size of pit
149 Mtr/ 1.2mx0.6mx1.50 m deep
15(B) Lattice Tower /Size of pit
1611.4/10.8 Mtr/ 1.5mx1.5m x1.80 m deep
1712.8/12.6 Mtr/ 1.5mx1.5m x2.10 m deep
18(C)Stay set/Depth of pit
198'x 3/4\\" -0.75x0.5x1.6 m
20Excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit.
21(A) Height of poles/R.S.Joist/M.S. Rail /Size of pit
229 Mtr/ 1.2mx0.6mx1.50 m deep
23(B) Lattice Tower /Size of pit
2411.4/10.8 Mtr/ 1.5mx1.5m x1.80 m deep
2512.8/12.6 Mtr/ 1.5mx1.5m x2.10 m deep
26(C)Stay set/Depth of pit
278'x 3/4\\" -0.75x0.5x1.6 m
28Excavation of pit in Hard rock ( Where blasting is required) to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit.
29(A) Height of poles/R.S.Joist/M.S. Rail /Size of pit
309 Mtr/ 1.2mx0.6mx1.50 m deep
31(B) Lattice Tower /Size of pit
3211.4/10.8 Mtr/ 1.5mx1.5m x1.80 m deep
3312.8/12.6 Mtr/ 1.5mx1.5m x2.10 m deep
34(C)Stay set/Depth of pit
358'x 3/4\\" -0.75x0.5x1.6 m
36Safe carriage of PCC poles including loading / un-loading
37a) 9 Mtr. Long-400 Kg /11 Mtr. PCC pole
38Within 10 Kms.
39Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
40Safe carriage of steel( fabricated and unfabricated) I.e.M.S. Rails, R.S.Joists, M.S.Channels, M.S.Angles, M.S.Flat, G.I.Stay Sets, G.I. Stay Wire, G.I.Wire Nut & Bolts etc. and ACSR Conductor including loading and unloading and stacking in Nigam store /at work site
41Within 10 Kms.
42Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
43Safe Carriage of insulator, hardware, cable etc.including loading/unloading and stacking in Nigam.stores etc.
44Within 10 Kms.
45Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
46Safe carriage of fabricated lattice towers structures and sub-station structures type AB, AB beams, isolators structures etc. including loading/unloading and stacking in the Nigam. Stores / at work site.
47Within 10 Kms.
48Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
49Erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. The support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item No. 5.7 the remaining portion of the pit will be back filled with soil. The nuts & bolts will be provided by the contractor as per Nigam's specification for which payment will be made at the prevailing store issue rates. The cost muffing and grouting will be paid extra.
50Lattice Structure
51Providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.
52Erection of PCC poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. The support is to be back filled with soil with proper ramming. The nuts & bolts are to be provided by the contractor as per Nigam's specification for which the payment will be made at the prevailing Discom store issue rates.
53PCC Poles 9 Mtr. Long (400 Kg)
54Erection &assembly of 2 Pole structures of steel supports or PCC poles in excavated pit in alignment after checking the same with plumb line.Including fixing of top bracing of M.S.Channels with pilot plates and clamps.The support is to be back filled with soil with proper ramming.The nuts &bolts are to be provided by the contractor as per Nigams specfication for which the payment will be made at the prevailing Discom store issue rates.
55PCC Poles 9 Mtr. Long(400 Kg.)
56Erection & fixing of G.I.Stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.The work includes fixing of stay clamps.Stay insulator with stay wire at both ends with proper tension.Size of stay set/stay wire
578\\"x3/4\\" with 7/8 SWG stay wire
58Laying ,jointing , stringing, tensioning and clamping of conductor with proper sag as directed , using bolted type hardware including binding on pin insulators,jumpering on section points with binding wire / P.G.clamps.Aluminium jointing sleeves will be used for jointing the conductor.The line must stand at proper voltage on charging.The contractor will be provide P.G.clamps for which payment will be made as per prevailing Discom issue rate.
59(B) IN RURAL AREA
60ACSR DOG
61Fixing of 33kv pin insulator with pins.
62Fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. The nuts &bolts are to be provided by the contractor as per Nigams specification for which payment will be made as per prevailing Discom store issue rates.
6333 KV line
64Assembly. Installation & commissioning of gang operated isolating switch on erected structure with setting for accurate operation including fixing of allied accessories completein all respect with post insulator and jumpering on both ends for connection with the system. The nuts and bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates. (B)G.O. switch . without earthing blade.
6533kv G.O.switch
66Laying , jointing,stringing,tensioning and clamping of G.I.Earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc.including proper binding at each end.The nuts and bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates.
67(A).In Urban Area
68G.I.Earth wire 6 SWG
69G.I.Earth wire 8 SWG
70(A).In Rural Area
71G.I.Earth wire 6 SWG
72G.I.Earth wire 8 SWG
73Earthing of line for all type of supports as per REC construction standards using Stay wire/GI wire with one pcs.of M.S.rod20mm dia each 3 meter long and driving into earth by mechanical means as per approved design.Drawing &specification.All material except MS rod,MS flat & stay wirewill be supplied by the contractor.If material is supplied by the contractor ,the payment will be made as per prevailing Discomstore issue rates.(In case of PCC poles earthing must be connected with earthwire already available on PCC pole at bottom)
74Fixing of 11kv B&S/T&C type disc insulator for 33kv lines (each unit consiting of 3 nos .disc.& 1set of H/W) on terminal point including fixing of hardware and strips.
75Supply of MS nuts & bolts
76Supply of PG Calmps
77Fixing of PG clamp of Dog /Racoon Conductor
78Fabrication of steel structures of M.S angle ,M.S.channel & M.S.Flat including cutting ,drilling as per design and drawing.
79Other steel items
80Drilling of holes in MS Channel / Angle /Flat
8115/16\\" dia holes(23.81 mm dia.)
82Laying of 33 KV XLPE Cable ( Aluminium Conductor ) underground as per relevant ISS / AVVNL standard including excavation of 30 cm width x120 cm deep trench in Kaccha land 25 cm thick under layer of sand. 'A' class bricks or concrete block covering refilling soil in the remaining portion and providing/fixing cable route indicators at every 30Mtr.of cable and at every turn.
83B) 3x240 Sq mm to 3x400 Sq mm
84Note:- Per mtr. Rate shall be paid extra for excavation of puccka road
85Laying of two ( D/C) 33KV, XLPE (Aluminium conductor) undrground cables w/o overlapping as per relevant IS/ AVVNL standard including excavation of 50 cm width x 120 cm deep trench in Kaccha land.25 cm thick under layer of sand. 'A' class bricks or concrete block covering refilling soil in the remaining portion and providing/fixing cable route indicators at every 30Mtr.of cable and at every turn.
86A) 3x50 Sq mm to 3x185 Sq mm
87B) 3x 240 Sq mm to 3x400 Sq mm
88Note:- per meter shall be paid extra for excavation in Pakka Road.
89Laying of 33 KV & 11KV XLPE cable without Road cutting i.e. through burrowing machine \\"VERMIER\\".(120 cm deep).Use of this technology must be restricted to the situation like:-
90(iii)When cable laid in a HDPE pipe
9133 / 11 KV 3C x 300 Sq.mm cable
92Add Cost of 200 HDPE pipe
93(b) HDPE DWC pipe(IS-14930)
94Intallation of 33 KV Cable (XLPE) termination / straight through joints ( Heat shrinkable type) as per manufacturer's kit guidance and direction including preparation of cable and testing refilling etc as required.(Including crimping of lugs)
95A) (ii) 3x240 Sq mm to 3x400 Sq mm
96C) (ii) Straight through joint 3x240 Sq mm to 3x400 Sq mm
97Providing and fixing of G.I. Pipe of 150 mm diameter. B-Class (IS:1239 mark),at the starting and finishing point of 33 KV under ground cables and to lay & clamp vertically with the existing support including labour charges. Please Enable Macros to View BoQ information

Other Detail

Information Source https://eproc.rajasthan.gov.in
Download FileName File Description File Size
Download a6232932-c043-433e-be1a-71ca5d19150e.html Tender Documents 0 KB
Download BOQ_982947.xls Tender Documents 0 KB
Download Tendernotice_1 (14).pdf Tender Documents 0 KB
Download TenderspecificationTN463.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.