Indian Tenders

Tender Notice

TDR 55071109
Tendering Authority Chandigarh Administration Engineering Department
Tender No PH8/2026/2722897/55
Tender ID 2026_CHD_91721_1
Tender Brief Tender For Repair & maintenance Of Ac (Split, Window Cassette, And Ductable Ac) In The Police Line And Police Station Non-Residential Building Sector 26 Chandigarh Fall Under The Jurisdiction Of Sub-Divisional Engineer, W/S Sub-Division No. 12, Chand
City Chandigarh
State Chandigarh
Document Fees Refer document
EMD INR 22501.0 /-
Tender Value INR 11.25 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Repair & maintenance Of Ac (Split, Window Cassette, And Ductable Ac) In The Police Line And Police Station Non-Residential Building Sector 26 Chandigarh Fall Under The Jurisdiction Of Sub-Divisional Engineer, W/S Sub-Division No. 12, Chandigarh.

Key Dates

Publish Date 13-04-2026
Last Date of Bid Submission 20-04-2026
Tender Opening Date 20-04-2026

Contact Information

Company Name Chandigarh Administration Engineering Department
Contact Person Er Sanjay Sahni
Address EEPH8 Chd

BOQ Items

Name of Work:- Repair & Mtc. of AC (Split, Window Cassette, and Ductable AC) in the Police line and Police Station Non-Residential Building Sector 26 Chandigarh fall under the jurisdiction of Sub-Divisional Engineer, W/S Sub-Division No. 12, Chandigarh.
Sl. No. Item Description
1Providing and fixing of compressor including Gas charging, welding testing and refitting at site complete in all respect (change of filter, capillary and flushing etc.) Make Emerson /kiroskar /mittsubish / hitachi/blue star,carrior or as per machines requirment. (NSR) .NSR
21.5 ton cap.compressor .
32.0 ton cap.compressor .
43.0 ton cap.compressor .
511.5 ton cap.compressor .
6Supply and fixing of R-22/R-134a/R-410A/R-32 various AC complete in all respect including change of filter, caoaillary and flushing with Nitrogen, Rectifying defector leakage etc .NSR
73 ton to 5 ton AC .
81.5 and 2.0 ton cap. Window A.C .
91.5 and 2.0 ton split type AC .
10Ductable AC 11 ton .
11Providing and fixing of hard copper piping with sleeve type insulation complete in all respect for all 2.0 TR/1.5 TR AC as per direction of the EIC. .NSR
12size -5/8 inch .
13size-3/8 inch .
14Repair and Replacement of AC Fan motor 1/6 HP including rewinding, rebushing, refiting at site single phase 220volts complete in all respects .NSR
15Providing and fixing of various running capacitors mfd make: Tasla and Siemens, EPCOS,Tibcon (NSR) .NSR
1680/100 Mfd .
1736/45 Mfd .
184/6 Mfd .
19Repair and Replacement of PCB circuit for window /Split type AC of all tanage. .NSR
20Providing and fixing of 3core wire 2.5mm2 between outdoor and indoor unit of split AC at various sites .NSR
21Providing and fixing of PVC rigid drain pipe of Diplast make of Size (3/4) complete in all respect from indoor unit to disposal point as directed by the E.I.C. .NSR
22Service and cleaning of split / window type /pillar type AC with the help of jet pump , cleaner complete in all respect. .NSR
23Service and cleaning of Ductable type AC with the help of jet pump , cleaner complete in all respect. .NSR
24Providing and fixing of sensor for cutoff AC with remote complete in all respect .
252 Ton to 3 Ton window / split AC .
26Ductable unit 8 Ton to 11 Ton .
27Providing and fixing of fan motor for split AC including dismantelling of old motor with fitting of new motor and rebate for old material .NSR
28Split AC-1/6 HP .
29Providing and fixing of condenser fan blade for window/split type AC's complete in all respect .NSR
30Providing and fixing of various type Contactor Block single phase and 3phase make: L&T Siemens .NSR
31ML 3/CL03 3 phase .
32ML 1.5/CL02 single phase .
33Providing and fixing of copper piping with sleeve type insulation between outdoor and indoor unit of spilt type AC at various sides requirment/manufacture standards .NSR
34Supply and installation and testing of microprocessor controller with wiring connector for ductable AC's (Indoor / Outdoor) complete in all respect .NSR
354 Ton to 11 Ton packing unit .
36Providing and Fixing of Voltage Stabilizers of (3 stage) with Copper winding Input range 160 to 280 Volts, Nominal output-230 Volts±10% Including cost of copper wire from stabilizer to AC unit and power plug to stabilizer upto 6m each with M.S. body of 22 gauge sheet (powder coated), complete in all respects Make Deol or Jewel Volts,V-Guard (5 KVA). .NSR
37Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. .E&M DSR 20252.10
38Single pole and neutral .2.10.2
39Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. .E&M DSR 20252.15
4063 A .2.15.3 Please Enable Macros to View BoQ information

Other Detail

Information Source https://etenders.chd.nic.in
Download FileName File Description File Size
Download 0ca426d7-3955-45a0-95cb-3f718d3296b2.html Tender Documents 0 KB
Download BOQ_112218.xls Tender Documents 0 KB
Download Tendernotice_1 (7).pdf Tender Documents 0 KB
Disclaimer :