Indian Tenders

Tender Notice

TDR 55067508
Tendering Authority Madhyanchal Vidut Vitran Nigam Limited
Tender No 48/SE(T)AMAUSI ZONE/2025-26
Tender ID 2026_MVVNL_1116162_2
Tender Brief Tender For Different Type Of Repairing, Maintenance And Carriage Work Against O And M Scheme Under Jurisdiction Of E.E., 11 Kv And Lt Nadarganj, Amausi Zone, Lucknow
City Lucknow
State Uttar Pradesh
Document Fees INR 3540 /-
EMD INR 45500.0 /-
Tender Value Refer document
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Different Type Of Repairing, Maintenance And Carriage Work Against O And M Scheme Under Jurisdiction Of E.E., 11 Kv And Lt Nadarganj, Amausi Zone, Lucknow

Key Dates

Publish Date 13-04-2026
Last Date of Bid Submission 18-04-2026
Tender Opening Date 18-04-2026

Contact Information

Company Name Madhyanchal Vidut Vitran Nigam Limited
Contact Person SUPERINTENDING ENGINEER, (TECHNICAL), AMAUSI ZONE
Address Sec-5, D, Vrindavan, Amausi Zone, Lucknow

BOQ Items

Name of Work:- Different Type of repairing, maintenance and carriage work against O and M Scheme UNDER JURISDICTION OF E.E., 11 KV and LT Nadarganj, Amausi Zone, Lucknow
Sl. No. Item Description
1Safe carriage, loading and unloading of following material from ESC DaliganjLucknow in work site J.E. dump store
2Line Material
3PCC Pole 8.5/9 Mtr long.
4S.T.P. Pole 9/11 Mtr. Long
5Repairing of damage/Rusted Steel Tubular Pole by digging of pit up to2 for proper position, Putting 3 Nos. Angle From of size 35x35x6 mm, 3 Long properly welding on 3 circle with pole than Grouting and Plinthing 300 mm Above level with cement concrete and sand and bricks ballast, (All material, labour and T&P will be provided by the Contractor)
6Opening and dismantling of all the wire and accessories from tilted pole and digging the pit for Strengthening of existing tilted support of HT/LT lines after strengthening of tilted pole fixing of all accessories and re-stringing of old HT/LT line with help of T&P.
7Dragging of ST/PCC Pole to pit site, digging of pit erection and grouting (As per RESPO Norms) of 11 KV line with fixing of necessary item, such as V-type X-arm, F-bracket, 11 KV Pin insulator, Guarding angle (1.8 mm 65x65x6) with Nut & bolts its ramming as per RESSPO Specification. Only Pole and insulator will be Provided by the Department.
8Dragging of ST/PCC Pole from Dump Store to pit site, digging of pit erection and grouting (As per RESPO Norms) of LT support suitable for laying of ABC Line on 8.5 Mtr Long PCC Pole by providing of necessary eye hook/Lt Shackle insulator with Clamps and its accessories etc. as per RESSPO Specification. Only Pole will be Provided by the Department.
9Well type earthing of with 60 Fit Deep boring and providing GI Pipe 1.5\\" dia (\\"B\\" Class) and earthing must be joint by G.I. Strip of 32x5 mm thick long attached with nut & bolts and GI pipe cap. All material and labour shall be supplied the contractor.
10Wiremess fencing of 11/0.4 KV S/S shall be made of rectangular of size as per site requirement not exceeding 3 meter fabrication 45x45x5 mm angel the frame is also have 1 no. Horizontal runner of MS flat 40x5 welded in middle to support of wire mesh. Rectangular welded type wire mess of size 50x25 made of 12 S.W.G. wire mess shall be welded all along the periphery of the frame as well as on horizontal runner to give extra strength of welding to wire mess welded on the frame. Diagonal bracing of all the frame panel will be welded with Ms flat of size 25x3mm to support as per RESPO specification & direction of E/I. All Material provided by contractor.
11Chemical Earthing system with outer pipe diameter 50mm, inner Strip 40x6, length 3000 mm. galvanization up to 200 micro, earthing pipe with crystalline conductive mixture filled inside the pipe with anti-corrosion & high conductive along with 50 Kg(As per required) of BFC which should be capable to reducing the soil resistively with good moisture retaining capacity.(Specification of chemical earthing and drawing is hereby enclosed). All material shall by supply by the contractor.
12Re sagging of Damage L.T/ ABC Line, opening of ABC at service point from distribution box and opening of Consumer service cable after Re-sagging of ABC Re Connection of Consumer Service cable on ST Pole/PCC . (All the material will be arranged by the Contractor)
13Resagging of damage H.T. line along with spare parts for various spans.
14Replacement of damage/burned and Proper laying & commissioning of (3x50/3x95/3x120 sq.mm) XLPE Aerial Bunched Conductor. Only ABC Provided by department.
15Painting of ST pole with one coat of red oxide & two coats of best quality top 2 mtr PO Red paint and remaining Al. Paint ISI mark as per RESPO norms.
16Lopping & Chopping of tree branches for clearance of HT/LT line. After clearance of line throughout pieces of tree branches of site.
17{kfrxzLr ifjorZdksa dks fifyaFk@pkj iksy] Mcyiksy] flaxy iksy ls mrkjdj@midsUnz ls mBkdj Mh0Vh0lh0 gsrq LVksj@dk;Z'kkyk rd igq¡pkukA
18250 KVA
190 to 30 K.M.
2031 to 50 K.M.
21400 KVA
220 to 30 K.M.
2331 to 50 K.M.
24630 KVA
250 to 30 K.M.
2631 to 50 K.M.
27lsaVj LVksj@ifjorZd dk;Z'kkyk ls ifjorZd dks ysdj {kfrxzLr ifjorZd ds LFkku ij yxkuk rFkk fo|qr vkiwfrZ pkyw djuk@ midsUnz ij igqapkukA
28250 KVA
290 to 30 K.M.
3031 to 50 K.M.
31400 KVA
320 to 30 K.M.
3331 to 50 K.M.
34630 KVA
350 to 30 K.M.
3631 to 50 K.M.
37oSdfYid O;oLFkk ds rgr {kfrxzLr ifjorZd ds LFkku ij mfpr {kerk ds ifjorZd u feyus ,oa rRdky fo|qr vkiwfrZ cgky djus gsrq 33@11 ds-oh- midsUnz ls ifjorZd eksckby Vªkyh dks {kfrxzLr ifjorZd ds LFkku ij igqapkdj fo|qr vkiwfrZ pkyw djukA
38oSdfYid O;oLFkk ds rgr ifjorZd eksckby Vªkyh dks okil mBkdj 33@11 ds-oh- lc LVs'ku ij igqapkukA
39G.S.T. Extra as per rules. Please Enable Macros to View BoQ information

Other Detail

Information Source https://etender.up.nic.in
Download FileName File Description File Size
Download BOQ_2121791.xls Tender Documents 0 KB
Download cc82126b-a9cb-420e-b72a-de65c1a2edca.html Tender Documents 0 KB
Download T48FORMM.pdf Tender Documents 0 KB
Download Tendernotice_1 (14).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.