Indian Tenders

Tender Notice

TDR 55065571
Tendering Authority Military Engineer Services
Tender No 8549/E8
Tender ID 2026_MES_753233_2
Tender Brief Corrigendum : Tender For Provn Of Solar Power Plant Of 500 Kwp At Fort William Under Ge(Fw) Kolkata (Risk And Cost For Only Those Items Which Are Not Executed By The Contractor M/S Bhel)
City Kolkata
State West Bengal
Document Fees INR 500 /-
EMD INR 81000.0 /-
Tender Value INR 40.50 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Provn Of Solar Power Plant Of 500 Kwp At Fort William Under Ge(Fw) Kolkata (Risk And Cost For Only Those Items Which Are Not Executed By The Contractor M/S Bhel)

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 30-04-2026 Date Corrigendum Date 04-05-2026
2 28-04-2026 BOQ Corrigendum Other 04-05-2026
3 23-04-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 30-04-2026
4 23-04-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 30-04-2026

Key Dates

Publish Date 30-04-2026
Last Date of Bid Submission 04-05-2026
Tender Opening Date 05-05-2026

Contact Information

Company Name Military Engineer Services
Contact Person Garrison Engineer (FW) Kolkata
Address D9 Commissariat Road Hastings Kolkata 700022

BOQ Items

Name of Work:- PROVN OF SOLAR POWER PLANT OF 500 KWP AT FORT WILLIAM UNDER GE(FW) KOLKATA (RISK AND COST FOR ONLY THOSE ITEMS WHICH ARE NOT EXECUTED BY THE CONTRACTOR M/S BHEL)
Sl. No. Item Description
1Overhauling upto 50 kw inverter Bluetooth enabled with comprehensive LCD, in-built MPPT, Rated AC Active Power – 50KW, Rated AC Voltage – 400 (+/- 20%), 3-Phase, 50 Hz Output, anti-islanding protection, AC over current protection, AC short circuit protection, protection against DC reverse connection, AC & DC surgeprotection, insulation resistance detection, leakage current detection, P V String fault detection etc., Wifi and GPRS compatible with remote monitoring facility complete all as specified and directed. Make : M/s Jackson Engineer/ M/s Thermax Limited/M/s Su-Kam Power System Ltd
2Supply and fixing dataloger Polycabornate, watertight to IP68 Humidity loggers splash proof from topSize 65 × 31 × 106 mm Weight 115 g Ambient -40 + 85 °C Sensor (see sensor specifications) Temperature: Precision Thermistor or Pt 100Humidity: capacitive precision Memory E model: 12,000 to 25,000 sets of measurementsC model: 10,600 sets each sensorF model: 10,600 sets each sensor (21,200 if only one)A & P: 20,000 to 60,000 sets of measurementsInterface Special interface cable to serial port and/or special interface cable to USB PortSecurity ID Permanent serial numberResolution Temperature: Better than 0.1 °C (see sensor specifications)Humidity: Better than 0.1%RH
3Supply and fixing Cat 1 data cable for 10 nos inverter Speed (Data Rate: the speed of a cable refers to the amount of data it can transmit per second. 100 Mbps means the cable can transmit 100 million bits of data a second. In a commercial network, speed is usually dictated by the equipment you are connecting (for example, a network switch with Gigabit Ethernet ports). In the home, choose a cable that can support the speed of your Internet connection, plus some room for speed upgrades in the future. A cable's Category designation is an easy way to identify the speed of a cable.) complete all as specified and directed.
4Supply and fixing Inverter display and switch repairing
5Supply and fixing Pv Module 325 wp Type Poly Dimensions 77.17\\" x 39.02\\" x 1.57\\" Weight 49.60 lbs Frame Clear Anodized Connector MC4 Electrical Watts (Pmax) 325 W Max Power Voltage (VMPP) 37.39 V Max Power Current (IMPP) 8.69 A Open Circuit Voltage (VOC) 46.38 V Short Circuit Current (ISC) 9.17 complete all as specified and directed. Make BHEL/BEL/VIKRAM SOLAR
6(A )Cable condute pipe 32mm dia Material Virgin ThermoplasticMaterial Grade PE 100Pressure Rating of Pipe PN 8Base Density at 27°C (Kg/m³) 930-960Melt Flow Rate at 190°C using a 5 Kg mass (g/10 min) 0.2-1.1 Nominal Diameter (mm) 32 Color Of Pipe As per Clause 6.2 of governing specifications (B) Cable trays & accessories shall be galvanized with Zinc coating of 75 microns (minimum),86 microns (average) for 2.0 mm thick product & 55 microns (minimum), 65 microns(average) for 1.6 mm thick product. Also, min. weight of Zinc deposit shall be 610 gramsper square meter for 2.0 mm thick product & 460 grams per square meter for 1.6 mmthick product.
7Supply and fixing DC Cable poly cab1C x 4 Sq.mm1 Manufacturer Name Polycab Wires Private Limited 2 Brand Name POLYCAB 3 Rated a.c. Voltage 1100V 4 Rated d.c. Voltage 1500V 5 CONDUCTOR a) Material Annealed high conductivity Flexible copper conductor as per Class 5 as IEC 60228 b) Conductor Size Sq.mm 4 c) Max. D.C Cond. Resistance at 20 Deg. C. Ohm/km 4.95d) No/Dia of strands (No/mm) 56 x 0.36 INSULATION a) Material XLPE insulationb) Thickness - Nominal mm 0.7 c) Core Identification Red for +ve DC & Black for –ve DC 7 Sheath a) Material UV Stabilized PVC ST2 Sheath b) Nominal Thickness mm. 0.9 d) Sheath Colour Black with Red Stripe outer sheathing for +ve DC & Black outer sheathing for –ve DC 8 Overall Supply and fixing Diameter ( Approx) mm 6.0 ± 0.5mm 9 Current rating (In Air) A 45 10 Max. conductor temp. under normal operatingconditions °C 90°C 11 Max. conductor temp at the termination of short circuit °C 250°C 12 Standards to which the cables confirm UV resistant according to DIN 5338713 Recommended minimum bending radius in mm 8 - 10 times the overall diameter of the cable14 Max. Tensile strength when pulled with pulling eye Kg 20 15 Printing POLYCAB 1C X 4 SQ.MM. XLPE/UV PVC ST2 SOLARDC CABLE TYPE -3 MAKE- Polycab/ Universal/KEI
8Supply and fixing MC4 Solar Connector Conductor Pins are Made of Copper with Outer Tin Plated. Made of High Quality PPO + PA material, It makes a rock solid connection after you crimp the pin with wire, and these are operated perfectly under heavy load.With excellent aging resistance and UV endurance, it can be used in harsh environment. Estimated Life 25 Years. Once you complete the installation, your joint is waterproof.This Solar Male/Female Connectors are compatible with different insulation diameters from 2.5mm to 6mm Single and Double PVC Solar DC Wires complete all as specified and directed.
9Supply and fixing SPD changing for dc site 80 Nos L & t or CTEL make UCPV 1200 vdc rated discharge current ratings like Nominal In 20 kA and Maximum Imax 40kA for the 8/20 µs waveform,complete all as specified and directed.
10Supply and fixing SPD chang for ac site 10 nos L & t or CTEL makeSPD specificationNominal voltage (UN) V AC — 230 230 —Maximum operating voltage (UC) V AC 255 per Phase Lightning impulse current (10/350 μs) (Iimp) kA 100 Nominal discharge current (8/20 μs) (In) kA 100 Maximum discharge current (8/20 μs) (Imax) kA 100 Total discharge current (10/350 μs) (Itotal) kA 100 Voltage protection level (Up) kV 1.5 Ability to independently switch off the following current (Ifi) A 100 No following currentNo following current 100 IPE uA < 4TOV 120 min L-N V AC — 440 440 —TOV 5 s L-N V AC — 335 335 —TOV 200 ms N-PE V AC 1200 — — 1200Response time (ta) ns 100 Short-circuit proof at maximum overcurrent protection - ISSCR kArms — 50 Maximum overcurrent protection(fuse rating gL/gG) A — 250Maximum overcurrent protection for serialconnection
11Supply and fixing Notice Board with LED glow sign fixture along with MS frame/stand for fixing arrangement complete all as specified and directed.
12Supply and fixing LIGHTING ARESTER ESE TYPE (Make: OBO BETERMAN OR JMV) : voltage protection level of ≤1.3 kV, surge current capacities such as 35 kA or 125 kA (10/350 µs), response times under 100 nanoseconds, and operating temperature ranges of -40°C to +85°C complete all as specified and directed. MAKE - NIMBUS/LPI/ERKO
13Supply and fixing ANEMOMETER: Brand ‎HTC InstrumentMaterial ‎Plastic Item dimensions L x W x H ‎28 x 67 x156 Millimeters Item Weight ‎350 GramsUPC ‎734026222367 HTC InstrumentManufacturer ‎HTC InstrumentCountry of Origin ‎India Model number ‎AVM-07Number of Memory Sticks ‎1Special Feature ‎USBItem Weight ‎350 g Product Dimensions ‎2.8 x 6.7 x 15.6 cm; 350 g Item model number ‎AVM-07Item Height ‎15.6 Centimeters Item Width ‎6.7 Centimeters Operating System ‎Windows PhoneIncluded Components ‎Meter
14Supply and fixing Spike arrngment for top edge of solar panel to avoid bird standing complete all as specified and directed.
15Supply and fixing Isolation switch 4 pole to to isolate the grid by utillity personal to carry out maintenance after locking this switch complete all as specified and directed.
16Supply and fixing Digital energy meter Class of accuracy : 1.0 S (No drift in tolerance of accuracy with time) (Meter should record energy at 1% Ib at UPF preferably with an error band + 2%) Supply Voltage : 240V, (– 40% to + 20%) Frequency : 50 Hz + 5% Current Range (basic) :10A for10 – 60A Maximum Current : 60A Starting Current : 0.2% of Ib at UPF Power factor range : Zero (lagging) – Unity – Zero (Leading) Power Loss : Voltage Circuit Less than 1.5W / 10VA per phase : Current Circuit Less than 4VA Resistance to impulse voltage : Minimum 10KV peak Resistance to surge voltage : Minimum 8KV peak of 1.2/50 Micro sec. Test Voltage at 50 Hz for 1min : 4 KV rms – as per IS 13779 Clock time accuracy : + 3 min/year – as per CBIP Tech Rep 88 MAKE - SIEMENS/L&T/HPL/HAVELLS
17Supply and fixing Numarical revers power relay and differencial power protection relay complete all as specified and directed.
18Supply and fixing Temper sensors with wheater shield and ambient temp sensors for spv module complete all as specified and directed.
19Provision of cable gland and pvc tag for 10 nos inverter complete all as specified and directed.
20Supply and fixing Data acquisition system having time and date stamped data lo withs with suitable for display of system parameters complete all as specified and directed.
21Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ. Please Enable Macros to View BoQ information

Other Detail

Information Source https://defproc.gov.in/nicgep/app
Download FileName File Description File Size
Download BOQ_851381.xls Tender Documents 0 KB
Download fdc51538-6f17-488c-b1de-21d4cb585435.html Tender Documents 0 KB
Download TENDERDOCUMENT8549.pdf Tender Documents 0 KB
Download Tendernotice_1 (2).pdf Tender Documents 0 KB