Tender Brief Corrigendum : Tender For Supply Installation Testing and Commissioning of Mgps Work In Construction Of Critical Care Block Hospital At District Jhunjhunu
City Jaipur
State Rajasthan
Document Fees INR 1180 /-
EMD INR 170900.0 /-
Tender Value INR 85.45 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Supply Installation Testing and Commissioning of Mgps Work In Construction Of Critical Care Block Hospital At District Jhunjhunu

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 15-04-2026 Corrigendum to modified dates 15.04.2026 Date 20-04-2026

Key Dates

Publish Date 15-04-2026
Last Date of Bid Submission 20-04-2026
Tender Opening Date 21-04-2026

Contact Information

Company Name Rajasthan State Road Development And Construction Corporation Limited
Contact Person GM RSRDC LTD JAIPUR
Address GM RSRDC LTD SETU BHAWAN, JHALANA DOONGARI, JAIPUR

BOQ Items

Name of Work:- SITC of MGPS Work in Construction of Critical Care Block Hospital at District Jhunjhunu
Sl. No. Item Description
1MGPS Work
2SITC of Oxygen Outlets (imported) as per HTM-2022/02-01 of UKINFPA99C of USA as per enclosed technical specifications - (Imported) (European CE with 4 digit notafied body no / UL Listed
3SITC of Oxygen probes (imported) as per HTM-2022/02-01 of UKINFPA99C of USA as per enclosed technical specifications - (Imported) (European CE with 4 digit notafied body no / UL Listed
4SITC of BPC (back pressure compensated) flow meter with humidifer made of nickel plated body , double jacketed with flow gradations marked on it . Desired flow will be setteled through rotary knob . Flow range should be between 0 to 15 1pm & work should be executed as per direction of engineer in charge .
5MEDICAL NITROUS OXIDE SYSTEM
6SITC of N20 Outlets (imported) as per HTM-2022/02-01 of UKINFPA99C of USA as per enclosed technical specifications - (Imported) European CE with 4 digit notafied body no / UL Listed
7SITC of N20 probes (imported) as per HTM-2022/02-01 of UKINFPA99C of USA as per enclosed technical specifications - (Imported) European CE with 4 digit notafied body no / UL Listed
8MEDICAL COMPRESSED AIR SYSTEM
9SITC of Air-4 Bar Outlets as per HTM-2022/02-01 of UKINFPA99C of USA as per enclosed technical specifications - (Imported) (European CE with 4 digit notafied body no / UL Listed
10SITC of Air-4 Bar probes, as per HTM-2022/02-01 of UKINFPA99C of USA as per enclosed technical specifications - (Imported) (European CE with 4 digit notafied body no / UL Listed
11SITC of Air-7 Bar Outlets , as per HTM-2022102-01 of UKINFPA99C of USA as per enclosed technical specifications - (Imported) (European CE with 4 digit notafied body no / UL Listed
12SITC of Air-7 Bar probes, as per HTM-2022102-01 of UKINFPA99C of USA as per enclosed technical specifications - (Imported) (European CE with 4 digit notafied body no / UL Listed
13MEDICAL VACCUM CENTRAL SYSTEM
14SITC of Vacuum Outlets , as per (imported) HTM-2022102-01ofUKINFPA99C of USA as per enclosed technical specifications - uropean CE with 4 digit notafied body no / UL Listed
15SITC of Vacuum probes, as per (imported) HTM-2022102-01ofUKINFPA99C of USA as per enclosed technical specifications - European CE with 4 digit notafied body no / UL Listed
16SITC of suction unit (Suction Controller and Collection Jar) with posibility to configure required capacity capacity collection Jar and should meets the requirements as per BSEN ISO 100793:2009. The unit must designed to operate with the vaccum line of MGPS. The collection Jar must accumpained with Vaccum regulator suitable for 0-14.7 psig with flow rate 0-55 Lmp (min) for operating temperature - 18°C to 50°C with ON/OFF facility. The collection Jar should be transparent, made of high quality polycarbonate that can be autoclaved at 121°C for 20 minutes for reuse and provided with auto stop to avoid over spill and contamination of the suction source when the jar collection reached optimized level. The complete unit supplied with filter to protect the source and pipe line from bacterial contamination.
17600 m1 Capacity collection Jar
18Supply, Installation, testing & commissioning of Theatre Vacuum Unit (2 jar nos capacity 2000 Ml) ( Imported) European CE with 4 digit notafied body no
19SITC of MGPS of medically grade as per BSEN-13348 with third party certification from Lloyds/TUV, degreased (ie free from oil, grease and particulate matters) seamless copper pipe confirming to ASTM B88 and all copper joining done by brazing with AWSA5.8, classification BCuP-5 or BS 1845 following procedure in accordance with ASTM B828 after purging with nitrogen. All pipe cutting shall be carried out with a radial pipe cutter and copper pipe fitting's shall comply with B4 alloy designation. Adequate support shall be provided while laying pipeline testing shall be done at 17 bar and after testing pipe shall be painted with two coat of enamel paint as per colour codification as per ISO 7396-Part-I 2016.
20SITC of Valve box made of CRCA sheet duly powder coated with transparent window which is installed in the MGPS for oxygen and vaccum line and should comply with ENIS05211:2001 complete with ball type valves and gauses as required for oxygen compressed air and vaccum line (three gas)
21For Three gas
22For Four gas
23For Five Gas
24SITC of microprocessor based auto alarm system (digital type) suitable for medical gas service provided with audible and visual alarm for MGPS Zoning. It should monitors the current status of oxygen /compressed air pressure in distribution pipeline of central medical supply system and trigger the alarm to alert. The system should comply BSEN ISO:7396-1:2007
25For Two Gas Services
26For Three Gas Services
27For Four Gas Services
28For Five Gas Services
29SITC of non lubricated ball type GM Isolation Valve with adapter & PTFE Seat having quarter turn handle opening of following sizes suitable for flow capacity 1500 LPM at 4.7 bar with maximum allowable pressure of 30 bar and suitable for working temperature ranging - 20°C to 130°C.Valve should be CE approved/ CE certified.
30For 12 MM OD pipe
31For 15 MM OD pipe
32For 22 MM OD pipe
33For 28 MM OD pipe
34For 42 MM OD pipe
35For 54 MM OD pipe
36SITC of Bed Head Panel of 1200 -1500 MM long made out from high strength extruded aluminium with powder coating with 4 nos 6/16 Amp switch socket and provision forfour Nos gas outlet point work should be executed as per directions of engineer in charge and of CE certified makes.
37P&F of Bed Panel accessories like Monitor Tray, Utility Basket, Vacuum Slider, Infusion Pump Pole with IV hooks, with proper nut bolts and screw and with proper finishing & work should be executed as per directions of engineer in charge of CE certified/ CE Approved .
38Monitor Tray
39Utility Basket
40Vacuum Slider
41Infusion Pump Pole
42Sub: Operation Theater 02 Nos Please Enable Macros to View BoQ information

Other Detail

Information Source https://eproc.rajasthan.gov.in
Download FileName File Description File Size
Download agrement.pdf Tender Documents 0 KB
Download AnnexureABCD_RTPPAct2012_AnnexureC.pdf Tender Documents 0 KB
Download AnnuxtureAElectBSR2022.pdf Tender Documents 0 KB
Download BOQ_980970.xls Tender Documents 0 KB
Download dead686b-f24d-46f7-9013-670740d7d0b5.html Tender Documents 0 KB
Download EligibilitycriteriaofBidd_1.pdf Tender Documents 0 KB
Download Engineering_Cost.pdf Tender Documents 0 KB
Download gentc_alongwith_dlptc.pdf Tender Documents 0 KB
Download PdBankAccountNumberDetails.pdf Tender Documents 0 KB
Download TECHNICALSPECIFICATIONSR3.pdf Tender Documents 0 KB
Download Tendernotice_1 (13).pdf Tender Documents 0 KB
Download various_Circulars_Office_Orders.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.