Tender for Demolation Of Tank Below Ground Level And Stacking The Unserviceable Material Complete In All Respect In All Leads And Lifts As Per The Direction And Entire To The Satisfaction Of Engineer In Charge . , Excavation In Foundations, Trenches Etc., In Earth Work,Lift Upto 1.50 Mts.Stacking The Excavated Soil Not More Than 3 Metres Clear From The Edge Of The Excavation And Then Returning The Stacked Soil In 15 Cm Layers, When Required In To Plinths Sides Of Foundation Etc. Consolidating Each Deposited Layer By Ramming And Watering And Then Disposing Of All Surplus Excavated Earth As Directed With In Alead Of 20 Metres Complete In All Respect In All Leads And Lifts As Per The Direction And Entire To The Satisfaction Of Engineer In Charge . , Providing And Laying Cement Concrete 1:4:8(1Cement:4Sand:8 Graded Stone Aggregate 20Mm Nominal Size)And Curing Complete Excluding The Cost Of Centring And Shuttering In Foundation And Plinth Complete In All Respect In All Leads And Lifts As Per The Direction And Entire To The Satisfaction Of Engineer In Charge . , providing and laying Cement Concrete 1 : 3 : 6 (1 Cement : 3 Sand : 6 Graded Stone Aggregate 40 Mm Nominal Size) & Curing Complete In Foundation & Plinth. Complete In All Respect In All Leads And Lifts As Per The Direction And Entire To The Satisfaction Of Engineer In Charge . , Providing Form Work With Steel Plates 3.15 Mm Thick Welded With Angle Iron In Frame 30X30x5mm. So As To Give Fair Finish Including Centring Shuttering Strtting And Proping Etc. With Wooden Battens And Balies Height Of Proping And Centring Below Supporing Floor To Ceiling Not Exceeding 4Mtrs And Removal Of Same For Insitu-Reinforcred Concrete & Plain Concrete Work In :- , Edge Of Slab And Breaks In Floors And Wall Under 20Cm Wide Complete In All Respect In All Leads And Lifts As Per The Direction And Entire To The Satisfaction Of Engineer In Charge . , Vertical Surfaces Such As Walls ( Any Thickness) Partitions And Like Including Attached Pillasters,Buttresses,Plinth And String Courses And The Like Complete In All Respect In All Leads And Lifts As Per The Direction And Entire To The Satisfaction Of Engineer In Charge . , Sides And Sofits Of Beams, Beam Haunching, Cantilever Breasumer And Lintles Not Exceding 1 Mtr In Depth In All Heights From Floor Complete In All Respect In All Leads And Lifts As Per The Direction And Entire To The Satisfaction Of Engineer In Charge . , Flat Surfaces Such As Soffits & Suspended Floors, Roofs Landing And The Like Complete In All Respect In All Leads And Lifts As Per The Direction And Entire To The Satisfaction Of Engineer In Charge . , providing and laying Cement Concrete 1:1.5:3 (1Cement:1.5 Sand:3 Graded Stone Aggregate 20 Mm Nominal Size Excluding Cost Of Form Work & Reinforcement For Reinforced Cement Concrete Work In :- , Foundation , Foootings Base Of Columns And The Like And Mass Concrete Complete In All Respect In All Leads And Lifts As Per The Direction And Entire To The Satisfaction Of Engineer In Charge . , Wall Any Thickness Not Less Than .10 M Thickness) Attached Pilasters,Buttresses, Plinth And String Courses Etc. From Top Of Foundation Level Upto Floor Two Level Complete In All Respect In All Leads And Lifts As Per The Direction And Entire To The Satisfaction Of Engineer In Charge . , Providing And Laying Cement Concrete 1:2:4(1Cement:2Sand:4 Graded Stone Aggregate 20Mm Nominal Size)And Curing Complete Excluding The Cost Of Form Work In :- , Suspended Floor ,Roofs, Landing& Shelves & Their Suport Balconies, Beams, Girders Bressumer And Cantilevers Upto Floor Two Level Complete In All Respect In All Leads And Lifts As Per The Direction And Entire To The Satisfaction Of Engineer In Charge . , Providing Tor Steel Reinforcement For Reinforced Cement Concrete Work Including Bending, Binding And Placing In Position Complete Upto Floor Two Level Complete In All Respect In All Leads And Lifts As Per The Direction And Entire To The Satisfaction Of Engineer In Charge . , providing & Fixing Steel Fibre Reinforced Concrete Man Hole Cover With Frame Having Frames Size Of 560 Mm Internal Dia.Should Not Be Less Than 100 Kg Complete In All Respect In All Leads And Lifts As Per The Direction And Entire To The Satisfaction Of Engineer In Charge . , Providing & Fixing G.I. Pipe Light Grade For Inlet/Outlet Pipe/Over Flow Pipe 50 Mm Dia Complete In All Respect In All Leads And Lifts As Per The Direction And Entire To The Satisfaction Of Engineer In Charge . , Providing And Fixing Brass Sluice Valve (With Hand Wheal) As Per I S Specification 50 Mm Dia Complete In All Respect In All Leads And Lifts As Per The Direction And Entire To The Satisfaction Of Engineer In Charge . , Steel Work Welded In Built Up Sections Trusses And Framed Work, Including Cutting Hoisting Fixing In Position And Applying A Priming Coat Of Red Lead Paint In Gratings Framed Guard, Bars, Ladders Railling, Brackets And Similar Work Complete In All Respect In All Leads And Lifts As Per The Direction And Entire To The Satisfaction Of Engineer In Charge . , Providing And Fixing 50 Mm Dia Double Flanged Puddle Collar For Conection With R.C.C.Walls Complete In All Respect In All Leads And Lifts As Per The Direction And Entire To The Satisfaction Of Engineer In Charge . , Finishing Wall With Weather Proofing Cement Paint( Apex Altima) Or Approved Brand And Manufacture And Of Requir-Ed Shade On Undecorated Wall Surface Two Coat To Give An Even Shade After Throughly Brushing. The Surface To Removal All Dirt, Dust And Removing Of Loose Material Complete In All Respect In All Leads And Lifts As Per The Direction And Entire To The Satisfaction Of Engineer In Charge . , Wire Crate Of G.I.Wire Filled With Boulders With Against The Wire ( Boulder Filling To Be Measured And Paid For Seprately ) G.I.Wire 5Mm Thick Corresponding To Swg-6 ( 15Cm X 15Cm) Complete In All Respect In All Leads And Lifts As Per The Direction And Entire To The Satisfaction Of Engineer In Charge . , Wire Crate Of G.I.Wire Filled With Boulders With Square Cut Faces Against The Wire ( Wire Crate To Be Measured And Paid For Seprately) Complete In All Respect In All Leads And Lifts As Per The Direction And Entire To The Satisfaction Of Engineer In Charge . , Fixing 2.00 Metre Long Reinforced Cement Concrete Fencing Struts As Per Approved Drawing. Earth Work Paid For Seperetaly.) Complete In All Respect In All Leads And Lifts As Per The Direction And Entire To The Satisfaction Of Engineer In Charge . , Providing & Fixing Of 1.80Mtr.High Fencing With 2.50Mtr.Rcc Posts 2.50Mtr.Centre To Centre With 7 Horizontal Lines And 2 Diagonals Of Galvanised Steel Bar Bed Wire Complete In All Respect In All Leads And Lifts As Per The Direction And Entire To The Satisfaction Of Engineer In Charge .
|