Indian Tenders

Tender Notice

TDR 54956545
Tendering Authority Military Engineer Services
Tender No 8121
Tender ID 2026_MES_759157_1
Tender Brief Corrigendum : Tender For Certain Repair To Sewage Lines, Man Holes, Septic Tanks, Cleaning Of Sewage Lines To Md/Otm Of Odtd, Shivaji Enclave Under Ge Dehu Road
City Pune
State Maharashtra
Document Fees INR 500 /-
EMD INR 38000.0 /-
Tender Value INR 19 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Certain Repair To Sewage Lines, Man Holes, Septic Tanks, Cleaning Of Sewage Lines To Md/Otm Of Odtd, Shivaji Enclave Under Ge Dehu Road

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 25-04-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 02-05-2026

Key Dates

Publish Date 25-04-2026
Last Date of Bid Submission 02-05-2026
Tender Opening Date 04-05-2026

Contact Information

Company Name Military Engineer Services
Contact Person Maj Hridayakumar KV
Address Garrison Engineer, Dehu Road, Pin - 412101

BOQ Items

Name of Work:- Certain repair to sewage lines, man holes, septic tanks, cleaning of sewage lines to Md/OTM of ODTD, Shivaji Enclave under GE Dehu Road
Sl. No. Item Description
1Dewatering of following including disludging of sludge at bottom in foul condition including taking out other dirty and flithy materials from manhole and septik tanks by sewage pumps or manually using buckets/baskets lifting the same upto 4.50 m depth of tank / MH and removing outside MD land including cleaning/clearing for following:-
2Manhole of any dimension upto 1.5 m deep
3Manhole of any dimension exc 1.5 m but n exc 3.00 m deep
4Septik tank upto 10 User capacity
5Septik tank upto 50 User capacity
6Septik tank exc 50 but n exc 100 User capacity
7Cleaning of SWG/RCC Sewage line of 150mm bore dia of pipe of foul condition by rodding the drain/sewage line using flexible rod/suitable device or by any other means for removing blockage from sewar line, mud, silt and any other debries obtained from sewage line with water to remove blockage and cleaning the entire rubbish, sludge etc and burrying the material obtained from sewage line including all precautionery and safety measures etc complete all as specified and directed.
8All as per item No. 02 above for 200 mm dia pipe complete all as specified and directed by Engineer-in-Charge.
9Removing blockage from water closet, floor or gully or Nahani Trap traps and bends by rodding thoroughly and pouring water under pressure and Cleaning, clearing the drainage to efficient and Smooth flow of sludge/waste water all as specified and directed by Engineer-in-Charge.
10Demolition of cement concrete (reinforced )as in manholes cover complete all as specified and directed by Engineer-in-Charge.
11M&L for precast cement conrete (1:2:4) type B-1 (20mm graded stone agg) as in cover slabs for man holes, set and jointed in CM (1:4) complete all as specified and directed Note:- Reinforcement shall be measured and paid separately.
12M&L for mild steel TMT bars 6 to 8 mm and over dia cut to length, bent to shape required incl cranking, bending, hooking ends & binding with & incl mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engineer-in-Charge.
13Demolition of brick work or stone/boulder masonry including all quoins, arches, pillars etc , precast concrete articles and precast concrete block walling built in cement mortar complete all as specified and directed by Engineer-in-Charge.
14M & L for brick work with sub class 'B' bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:6 complete all as specified and directed by Engineer-in-Charge
15M&L for rendering 15mm thick in CM (1:4) on fair faces of brick work or concrete surface incl mixing of water proofing compound finished even & smooth with using extra cement complete all as specified and directed by Engineer-in-Charge.(Note: WPC shall be measured & paid seperately)
16Supply only liquid water proofing compound.
17Dismantling/ taking down AC waste / vent pipes fixed to walls with all fittings/ accessories 100 mm dia pipes all as specified and directed by Engineer-in-Charge
18S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints fixed to walls, or laid in trenches bore of pipe 110 mm dia complete all as specified and directed by Engineer-in-Charge.
19S&F 110 mm dia PVC (SWR) bends, any radius with access door complete all as specified and directed by Engineer-in-Charge.
20S&F 110 mm dia PVC (SWR) branch piece (Single Y) equal or unequal complete all as specified and directed by Engineer-in-Charge.
21S&F 110 mm dia PVC (SWR) branch piece double, (Double Y) equal or unequal complete all as specified and directed by Engineer-in-Charge.
22S&F 110 mm dia PVC (SWR) vent cowl complete all as specified and directed by Engineer-in-Charge.
23S&F PVC (SWR) pipes 75 mm dia ,single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed by Engineer-in-Charge.
24S&F PVC (SWR) bends any radius, 75mm dia pipe complete all as specified and directed by Engineer-in-Charge.
25S&F PVC (SWR) branch piece, single (single Y) equal or unequal,for 75mm dia pipe complete all as specified and directed by Engineer-in-Charge.
26S&F PVC (SWR) branch piece, double (double Y), equal or unequal,for 75mm dia pipe complete all as specified and directed by Engineer-in-Charge.
27S&F 75 mm dia PVC (SWR) vent cowl complete all as specified and directed by Engineer-in-Charge.
28Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortat for 150 mm dia pipes, all as specified and directed by Engineer-in-Charge.
29All as item No. 23 above but for internal dia of pipe 200mm dia complete all as specified and directed .
30M&L for reinforced cement concrete pipes class NP-2 , laid in trenches & jointed complete with collars, dia of pipe 150 mm complete all as specified and directed by Engineer-in-Charge.
31All as item No. 25 above but for 200 mm dia of pipe complete all as specified and directed by Engineer-in-Charge.
32M&L concrete bed to drain pipe of 150 mm dia including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C2 using 40 mm graded stone aggregate complete all as specified and as directed by engineer-in-Charge
33All as item No. 27 above but for 200 mm dia RCC pipe.
34Supply and fix in repair hume pipe septic tank 10 users capacity inclding all excavation earth work required and demolition and removal of old septic tank (any size) and removal of debris and connecting the new septic tank to the incoming sewer lines and connectd to soak pit as directed.
35Demolition of cement concrete ( unreinforced) in ground floors and paving n exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
36M & L for 75 mm thick PCC type D-2 1:4:8 (40 mm graded aggregate) as in sub base for tiling complete all as specified and as directed
37M & L for Chequered cement concrete tiles of 30 cm x 30cm x 25 mm thick rubber moulded any colour with grey cement and pigment,set and jointed in neat cement slurry in floors including 15 mm thick screed bed or bedding layers in cement mortar 1:6 for laying tiles complete all as specified and as directed.
38M & L for cement concrete Type C2 1:3:6 (using 40mm graded aggregates) as in plinth protection 75 mm thick finished top surface even and smooth without using extra cement complete all as specified and as directed.
39M & L for precast concrete interlocking paver block rubber moulded any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade with grey cement and pigment over 25 mm thick sand cushion complete all as specified and as directed.
40Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed .
41M & L non skid coloured ceramic tiles 7 to 8 mm thick area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm , in floors, etc.set and jointed in neat cement slurry and pointed in white or coloured cement to match. Including 15 mm thick screed bed or bedding layer in cement mortar 1:6 complete.
42M & L Glazed ceramic tiles in vertical surface 350mmx250mm/450mm x350x7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles incl backing coat 10mm thick in CM 1:4 all as direced.
43S&F in repairs vitreous china squating pan Orissa pattern of size 580x440 mm white with integral foot rest (excluding flushing cistern and flush pipe) all as specified and as directed by Enginner-in-Charge
44S&F vitreous china premium / 1st quality wash down water closet EWC white/ivory/off white incl all necessary accessories (excluding flushing cistern and flush pipe) all as specified and as directed by Enginner-in-Charge
45S&F as in repairs PVC low/high level flushing cristern white 10 litre capacity incl PVC inlet pipe with brass check low level full both sides alongwith PVC flush pipe 32mm dia jointed to WC and handle incl brackets all as directed.
46S/F in repairs Vitreous china wash basin white flat back size (630x450) mm including , waste pipe and plug and porcelain stopper and brackets incl cutting for and pinning in ends of brackets or erecting stand along with 32mm dia CP waste coupling and UPVC waste pipe incl Bottle trap of PTMT 32mm dia having minimum water seal of 25mm .(Minimum weight 32mm-260gms/ 40mm-270 gms) complete all as directed.
47S&F in repair brass chromium plated bottle traps 32 mm dia for wash basin with inlet and outlet screwed for pipe or connection including necessary packing, union and cap and fixed
48S & F in repairs pillar taps fancy type cromium plated with capstan heads, chromium plated, screwed down high pressure, and fly-nuts, screwed for iron pipe and fixed for 15 mm dia pipe complete all as specified and directed .
49S&F in repair Health faucet (ABS body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 mtr long flexible tube and ABS wall hook including making connection and fixed in position complete all as specified and as directed by Engineer-in-Charge
50S&F in repair bib tap 15mm dia fancy type with long body all as specified and as directed by Engineer-in-Charge
51S&F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
52Taking up or down steel tubing and connections including cleaning for refixing of 15 mm bore of pipe complete all as specified and as directed.
53Taking up or down steel tubing and connections including cleaning for refixing of 20 mm bore of pipe complete all as specified and as directed.
54Fixing only 15 mm bore GI pipe medium grade with all fittings and fixtures and fixed to wall, ceiling, floor complete all as specified and as directed.
55Fixing only 20 mm bore GI pipe medium grade with all fittings and fixtures and fixed to wall, ceiling, floor complete all as specified and as directed.
56M & L for 15 mm bore GI pipe medium grade with all fittings and fixtures and fixed to wall, ceiling, floor complete all as specified and as directed.
57M & L for 20 mm bore GI pipe medium grade with all fittings and fixtures and fixed to wall, ceiling, floor complete all as specified and as directed. Please Enable Macros to View BoQ information

Other Detail

Information Source https://defproc.gov.in/nicgep/app
Download FileName File Description File Size
Download 8121TenderDocuments.pdf Tender Documents 0 KB
Download BOQ_850319.xls Tender Documents 0 KB
Download de4acf18-f302-428b-8d49-d25e93e36120.html Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.