| 1 | Laying and Jointing PVC Pipe. Heading |
| 2 | Supply of XLPE Insulated power calbe (conforming IS-7098) 1100 Volt grade /Heavy duty power cable conforming to IS 1554- 1100 Volts grade. 2 core / 31/2 core/4 coreISI MARKED with Alu.Stranded / solid conductor Armoured 4 Core - 25 Sq.mm. (XLPE) |
| 3 | Supply of XLPE Insulated power calbe (conforming IS-7098) 1100 Voit grade/Heavy duty power cable conforming to IS 1554-1100 Volts grade. 2 core / 31/2 core/4 coreISI MARKED with Alu. Stranded / solid conductor Armoured 4 Core - 10 Sq.mm. (XLPE) |
| 4 | Supply of Double wall corrugated pipes (DWC) of HDPE (IS 14930 Part II -marked ) for cable laid under ground with necessary connecting sockets/ couplings,tees of same material .50.00mm outside dia. |
| 5 | Supply of Double wall corrugated pipes (DWC) of HDPE (IS 14930 Part II -marked ) for cable laid under ground with necessary connecting sockets/ couplings,tees of same material .77.00mm outside dia. |
| 6 | Laying of one number PVC insulated and PVC sheathedd power cable of 1:1 kV grade of size not exceeding 25 Sq.mm in the existing RCC Hume/Stone/Ware/G.I. pipe as required. |
| 7 | Suppying & installing G.I. Pipe for protection of underground cable fixed on wall/support/ in trench/ fixed between two rigid existing support of wall/ beam for erection of ceiling Fan/ down rod for stiff pendent for light luminaries/ fan/ protective for earthing, lightening conductor down strip/ everhead service line/ for submer cable or centrifugal pump for water supply with necessary iron clamp coupler, bend, te, elbow, nuts and bolts etc. complete in an approved manner as required to complete the job excluding cost of excavation/ dismateling & other finished masonary Item complete. A'Class G.I. Pipe ISI Marked (IS-1161- 69) (Road RRossing) 80 mm dia |
| 8 | Supplying, fixing,testing & commissioning wall / floor mounted LT Panel primer coated with two coat of enamel paint & provided with required gasket for dust/ vermin proof with degree of protection IP42 suitable for 415V 3 phase,50 Hz ,4 wire system fabricated out of CRCA sheet upto 2 mm thick(1.6 mm for doors) with frame work of angle iron/ channel/ bolted type construction duly compartmentalised for incomer,bus section , outgoings,cable alleys & CT,PT Ampere Meter ,Volt Meter , selector switches,Frequency Meter,phase indicating lamps , energy Meter complete including cost of busbar supports,detachable cable gland plates,2 earthing terminals, internal wiring & fixing of separately supplied MCBs, MCCBs,panel mounted Changeover switch/SFUs, etc. as required but |
| 9 | Supply of ISI marked and approved make of Maulded case circuit Breaker MCCB suitable for 3 phase 3 pole 50 HZ 415 volt AC Supply with respective Interrupiting Capacity (KA ) at 415 Volt cited againest their range standerd confirming to IS -8828 MCCB with breaking capacity 25 kA at 415 V current rating - 25 to 100 amps & 70%-100% adjustable |
| 10 | Supply, Installation, testing and Commissioning of 25 A rating four pole contractor, designed specific contrat material AgSnO2 for lamp loads and AC load for high starting current. It shall work at an ambient temperature of( - 20 ) to (+ ) 50 deg C and auto-On- Off selector version. It shall have 3 Kv short circuit protections. The mounting shall be on 35 mm DIN rail (EN 60715 ) |
| 11 | Astro time switch for lights on - off based on sinrise & sunset timing supply, installation, testing & commissioning of Astro-time switch based on astro program i.e. calculation of sunrise & sunset times through date, time and indian PIN codes. It shall have an option of astro ON period override by time switch and offset function which allows programming of switching times offset from the astromic time. The 230 V ac operated astro time witch shall have an operating range of 96..253 V AC with 1NO 16 A, AgSno2 contact material with starting current of 120 A and 1CO cadmium free contacts, it shall have LCD status indication with back light display along with internal easily replacable battery on the front side for set up and programming. the electrical life at rated load AC1 shall be 1 lakh cycles and shall work at ambient temperature of -20 to +50 deg C. It shall have a dielectric strenght between supply and open contacts of 4000V AC, between open contacts 1000V AC respectively and rated impulse voltage (between supplyand contacts) of 6kV and rated impulse voltage( between open contacts) of 1.5 kV. The mounting shall be on 35 mm DIN rail (EN 60715) and shall have necessary approvals like CE, IMQ and EAC. |
| 12 | Supplying of ISI Marked and accepted standard of Miniature Circuit Breaker (MCB) of 'C' series suitable for 240/415 Volts. 50 Cycle, 10 kA Value AC suppy confirming to IS : 8828 : 1996, IEC : 60898 :2002 but without enclosures :- FOR Four (FP)- 50 to 63 Amp rating |
| 13 | Supplying and fixing of high Breaking Capacity (HBC) fuse link bolted connection type as per IS:13703:1993 & IEC:60269:1986 with 80 KA breaking Capacity of approved make , 80 Amp. To 125 Amp. |
| 14 | Fixing of MCB/MCCB/ Isolator1Fixingof MCB/ Isolator SP/DP/TPN /FP in sheet steel enclosure as required as per accepted practice, including mounting on busbar and cable connection etc. complete |
| 15 | 4 Pole epoxy connector Supplying and fixing of 4 Pole epoxy connector nut & bolt type, 30Amp. 500Volt. in existing box as required as per specification: |
| 16 | Supply and fixing of multicore round HRFR/FR PVC insulated copper flexible conductor and PVC sheathed cables 1100 volts as per IS 694- 1990 of app make : 30/0.25mm 3 core x1.5 sqmm wire |
| 17 | BRASS COMPRESSION GLAND Supplying and fixing heavy duty calbe gland for P.V.C. insulated armoured cable with brass washer, Rubber ring complete erected with cable and lead connection etc. as per specification complete Gland size 22 mm suitable for cable 2,3,3 1/2 x 10 sqmm or 2x16 sq. mm) |
| 18 | BRASS COMPRESSIONGLAND Supplying and fixing heavy duty calbe gland for P.V.C. insulated armoured cable with brass washer, Rubber ring complete erected with cable and lead connection etc. as per specification complete Gland size 22 mm suitable for cable 2,3,3 1/2 & 4 upto 6 sq.mm |
| 19 | Supply and fixing cramping type aluminum lugs as per I.S.s specfication suitable for following site of cable with alumunum copper solid standerd conductor evently RRamped with high/ Pressure to and connected to swich gear / bus / mcccb /mcb etc. as requireted complated . for Conductor size -35 sqmm |
| 20 | Supplying of ISI Marked and accepted standard of Miniature Circuit Breaker (MCB) of 'C' series suitable for 240/415 Volts. 50 Cycle, 10 kA Value AC suppy confirming to IS : 8828 : 1996, IEC : 60898 : 2002 but without enclosures :- SINGLE POLE (SP) 6 Amp to 32 Amp Rating |
| 21 | Supply of XLPE Insulated power calbe (conforming IS-7098) 1100 Voit grade/Heavy duty power cable conforming to IS 1554-1100 Volts grade. 2 core / 31/2 core/4 coreISI MARKED with Alu.Stranded / solid conductor - Armoured 4 Core - 16 Sq.mm. (XLPE) |
| 22 | providing and fixing of bakelite sheet 10 mm thick one mcb 6 -32 amp SP and 16 sq mm stud type 4 way epxoy connector for decorative designer pole/ octagonal pole box. |
| 23 | Supply of cable jointing kit |
| 24 | Testing, commissioning and restoration of street light system including switching ON/OFF trial. |
| 25 | Installing of Double wall corrugated pipes (DWC), laying of cables, Below road/ground surface, including excavation, back filling with excavated material with ramming and making the surface good |
| 26 | Providing and fixing 4.0 mm gi wire on surface or in nececerised consealed for loop earth as requred Please Enable Macros to View BoQ information |