Indian Tenders

Tender Notice

TDR 54872951
Tendering Authority Directorate Of Municipal Administration
Tender No MC/WS/2026-27/02ELECTRICAL
Tender ID 2026_DMA_1290915_1
Tender Brief Corrigendum : Tender For Water Supply Deppt. (Annual Rate Maintenance Contract For Electrical And Mechanical Works) (2026-27)
City Jalgaon
State Maharashtra
Document Fees INR 2000 /-
EMD INR 10000.0 /-
Tender Value Refer document
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Water Supply Deppt. (Annual Rate Maintenance Contract For Electrical And Mechanical Works) (2026-27)

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 06-04-2026 Date Extension Date 09-04-2026

Key Dates

Publish Date 06-04-2026
Last Date of Bid Submission 09-04-2026
Tender Opening Date 10-04-2026

Contact Information

Company Name Directorate Of Municipal Administration
Contact Person CHIEF OFFICER FAIZPUR MUNICIPAL COUNCIL
Address CHIEF OFFICER FAIZPUR MUNICIPAL COUNCIL

BOQ Items

Name of Work:- Water Supply Deppt. (Annual rate maintenance contract for Electrical and Mechanical works) (2026-27)
Sl. No. Item Description
1Supplying and replacing MNX three pole power contactors {L&T MNX Power Contactors 415V AC (3 Pole)}/ Siemens/Metasol make 3 Pole, 3 Phase, AC (AC magnetic contactor, suitable for use with 3TF series motor control systems) for motor starter:
2MNX 9
3MNX 12
4MNX 18
5MNX 25
6MNX 40
7MNX 140
8MNX 185
9MNX 225
10MNX 300
11MNX 400
12MNX 550
13MNX 650
14SIEMENS - 3TF51
15SIEMENS - 3TF53
16LS Make MC - 225 a/4
17Supplying, erecting & marking MCB with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board:
1825 AMP 415 Volt mark
1932 AMP 415 Volt ISI mark
2040 AMP 415 Volt Isl mark
2163 AMP 415 Volt ISI mark
22125 AMP 415 Volt ISI mark
23200 AMP 415 Volt ISI mark
24Supplying and erecting electrical control panel electrical components:
25INDICATOR R, Y, B MAKE- TECNIC, 22.5 mm
26VOLT METR, range 0 - 500 volts, 96x96
27CT OPERATED AMMETER, range 0 - 200 amp., 96x96
28ROTARY SWITCH RYB AMP./VOLTMETER
29C- channel
30Rewinding of electric motor of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc.:
31Upto 10 HP
32Upto 20 HP
33Upto 40 HP
34Upto 100 HP
35Upto 150 HP
36Upto 250 HP
37Upto 350 HP
38Upto 450 HP
39Supplying and replacing No-Volt-Coil for motor having DOL starter and Star-Delta Starter from:
40Upto 15 HP
41Upto 30 HP
42Upto 90 HP
43Upto 125 HP
44Supplying, erecting & terminating XLPE insulated unarmoured cable 1100 V aluminium conductor complete erected with lugs, on wall/ trusses/pole or laid in provided trench/ pipe:
452CX10 SQMM
464CX10 SQMM
474CX16 SQMM
484CX25 SQMM
494CX35 SQMM
504CX50 SQMM
513.5CX70 SQMM
523.5CX95 SQMM
533.5CX120 SQMM
544CX70 SQMM
554CX95 SQMM
564CX120 SQMM
574CX150 SQMM
584Cx180 SQMM
594CX240 SQMM
604CX300 SQMM
61Supplying, erecting & terminating XLPE insulated unarmoured cable 1100 V copper conductor complete erected with provided lugs, laid in provided control panel /distribution boards / pipe:
621CX25 SQMM
631CX35 SQMM
641CX50SQMM
652CX2.5 SQMM
662CX4 SQMM
672CX6 SQMM
682CX10 SQMM
693CX2.5 SQMM
703CX4 SQMM
713CX6 SQMM
723CX10 SQMM
734CX4 SQMM
744CX6 SQMM
754CX10 SQMM
76Providing & erecting epoxy straight through joint outdoor/indoor for LTXLPE armoured cable with necessary material:
772.5 to 16 sq.
7825 to 50 sq.
7970 to 95 sq.
80120 to 185 sq. mm.
81240 sq. mm.
82300 sq. mm.
83400 sq. mm.
84Supplying & erecting crimping type copper lugs for cable complete:
85Upto 50 sqmm
86Upto 70-120 sqmm
87Upto 150-300 sqmm
88400 sqmm
89Supplying , erecting & terminating XLPE insulated, galvanised steel formedwire armoured (strip) cable 11 kV(UE), aluminium conductor laid in provided trench / pipe:
90Supplying , erecting & terminating XLPE insulated, galvanised steel formedwire armoured (strip) cable 11 kV(UE), 3 x 150 sq. mm. aluminiumconductor laid in provided trench / pipe
91Supplying , erecting & terminating XLPE insulated, galvanised steel formedwire armoured (strip) cable 11 kV(UE), 3 x 185 sq. mm. aluminiumconductor laid in provided trench / pipe
92Supplying , erecting & terminating XLPE insulated, galvanised steel formedwire armoured (strip) cable 11 kV(UE), 3 x 240 sq. mm. aluminiumconductor laid in provided trench / pipe
93Supplying , erecting & terminating XLPE insulated, galvanised steel formedwire armoured (strip) cable 11 kV(UE), 3 x 300 sq. mm. aluminiumconductor laid in provided trench / pipe
94Supplying , erecting & terminating XLPE insulated galvanised steel formedwire armoured (strip) cable 11 kV(UE), 3 x 400 sq. mm. aluminiumconductor laid in provided trench / pipe
95Providing & erecting epoxy straight through joint outdoor/indoor for LTXLPE armoured cable with necessary material:
962.5 to 16 sq.
9725 to 50 sq.
9870 to 120 sq.
99150 to 185 sqm.
100240 to 300 sqm.
101400 sqm.
102Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E )XLPE HT cable with necessary material:
103Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E )Providing and erecting Heat shrinkable indoor termination kit for 11 kV(UE)/22 kV ( E ) XLPE HT cable 3x up to 95 sq. mm. with necessarymaterial
104Providing and erecting Heat shrinkable indoor termination kit for 11 kV(UE)/ 22 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessarymaterial
105Providing and erecting Heat shrinkable indoor termination kit for 11 kV(UE)/ 22 kV ( E ) XLPE HT cable 3x240 to 400 sq. mm. with necessarymaterial
106Providing and erecting Heat shrinkable out door termination kit for 11 kV(UE)/ 22 kV ( E ) XLPE HT cable 3x up to 95 sq. mm. with necessarymaterial
107Providing and erecting Heat shrinkable outdoor termination kit for 11 kV(UE)/ 22 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessarymaterial
108Providing and erecting Heat shrinkable outdoor termination kit for 11 kV(UE)/ 22 kV ( E ) XLPE HT cable 3x240 to 400 sq. mm. with necessarymaterial
109Providing and erecting Heat shrinkable straight through joint kit for 11 kV(UE)/22 kV ( E ) XLPE HT cable 3x up to 95 sq. mm. with necessarymaterial as
110Providing and erecting Heat shrinkable straight through joint kit for 11 kV(UE)/22 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessarymaterial
111Providing and erecting Heat shrinkable straight through joint kit for 11 kV(UE)/22 kV ( E ) XLPE HT cable 3x240 to 300 sq. mm. with necessarymaterial
112Providing and erecting Heat shrinkable straight through joint kit for 11 kV(UE)/ 22 kV ( E ) XLPE HT cable 3x 400 sq. mm. with necessary material
113Fault detection and repairing of MCC panel and ATS panel:
114Fault detection and repairing of MCC panel and ATS panel as per site requirement (labour part only)
115Sub Stations (SS) works:
116Supply of transfomer oil
117Overhauling of 200 KVA transformer
118Overhauling of 800 KVA transformer
119Overhauling of 1000 KVA transformer
120Supplying and erecting 11 kV outdoor type gang operated air break, triplepole switch 200 A capacity with 3 post pin type insulator per phase,mounted in horizontal or vertical position with necessary channels on providedcross arm with adequate length of \\"C\\" class G.l. pipe for operating handleerected on extended square shaft. The operating handle provided with lockand key at suitable height from ground level with necessary clamp.
121Supplying and erecting 11 kV outdoor type gang operated air break, triplepole switch 400 A capacity with 3 post pin type insulator per phase,mounted in horizontal or vertical position with necessary channels on providedcross arm with adequate length of \\"C\\" class G.l. pipe for operating handleerected on extended square shaft. The operating handle provided with lockand key at suitable height from ground level with necessary clamp.
122Supplying and erecting, 11 kV outdoor type drop out fuse with insulatorcomplete with fuse holders, fuse barrel with metal fitting, fuse elementmounted on M.S. channel with working current of 15A capacity completeerected on provided cross arm.
123Supplying and erecting fencing of section having size 2450 mm in height fromground level and 1200 mm width with angle iron frame work erected in CCfoundation and painted complete as per specification no SS-AS/FSG
124Supplying and erecting 50 x 50 x 6 mm angle iron as corner support 2m longfixed at the middle of the fencing frame and the other side inclined at 30 degreeangle, in cement concrete foundation of 15 x 15 x 40 cm complete duly paintedwith one coat of red oxide and two coats aluminium paint complete.
125Supplying and erecting double leaf hinged door each 1500 mm in width x 1850mm in height using B class, GI pipe with angle iron supports, chain link wiremesh (jali) complete supported on channel iron, erected in foundation, and paintedcomplete
126Supplying & erecting barbed wire two ply with 12 SWG ply and 12 SWG barbwith a gap between two bars of 75 mm. firmly fixed on provided angle supportswith necessary materials complete. (6.044 meters/kg.).
127Transportation of 11/22 kV transformer above 315 kVA to 1000 kVA withoutloading & unloading (for handing over to section store/ repair works only)
128Dismantling the existing distribution transformer of any capacity from theplinth / foundation safely without any damages.
129Dismantling existing DO / AB switch set complete from D.P. structure in anapproved manner.
130Supplying and erecting 11 kV fuse barrel with metal fittings complete.
131Supplying and erecting hard drawn copper solid wire no. 0 to 6 SWGcomplete erected for connections on H.T. sides.
132Supplying and erecting extra thick alkathene pipe 10 mm dia. erected toenclose bare conductor wires complete.. (use shall be restricted to H.T.)
133Supplying heavy duty operating rod, outer dia 25 mm & inner dia 20 mmsuitable for 11 kV with brass couplings etc. for removing drop out fuses at 6meters length, 4 pieces each with rain shade with hand grip including earthlingchain 1.5m complete.
134Supplying and erecting copper tubular bus 20 mm dia 1.6 mm (16 SWG) thickfor the use of high tension over head bus and erected on provided HTinsulators with clamps, nuts and bolts complete. (weight per meter of bus isabout 1.7 kg.)
135Supplying and erecting clamps, made out of 25x3 mm, copper strips to befixed to tubular bus for connecting the bare copper wire to other equipment, withbrass nuts bolts of suitable dia complete.
136Supplying and erecting anti climbing devices, fabricated from pole clamps ofMS flat 40x5 mm, with drooping spikes 15 cm. in length, welded to it and erectedon pole complete.
137Supplying and fixing PVC synthetic elastomer electrically insulating matwith class B insulation conforming to IS: 15652 – 2006 having 2.5 mm thicknessup to 11 kV
138Supplying , erecting Indoor LED Fittings:
139Supplying and erecting CRCA powder coated corridor/passage light LEDfitting (4 feet) Max. 17W with high transitivity diffuser with system lumensoutput of Min. 2000 lumens , min. efficacy of 120 lumen/W, CRI>80, CCTupto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95,operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs.at L70B50, including driver, with end caps on provided PVC Block / woodenboard with 3 years warranty.
140Supplying , erecting Outdoor LED Fittings:
141Supplying and erecting integrated LED flood light fitting Max. 100W IP65 &IK07 class having pressure die-cast aluminium housing, having system lumensoutput of Min. 12000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCTupto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surgeprotection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with Ushaped bracket with 3 Years warranty
142Supplying and erecting integrated LED flood light fitting Max. 195W IP65 &IK07 class having pressure die-cast aluminium housing, having system lumensoutput of Min. 23400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCTupto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surgeprotection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with Ushaped bracket with 3 Years warranty
143Supplying , erecting point wiring and MCBDBs:
144Point wiring for independent plug in 20 mm FRLS grade HMS PVC conduitwith 1.5 sq.mm (2+1E) FRLSH grade copper wire, flush type switch, earthingand required accessories as per specification No: WG-PW/SW
145Supplying & erecting triple pole and neutral distribution board (TPNDB),SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type)
146Supplying , erecting Cable Enclosures / Excavation and Earthing:
147Supplying and erecting iron work, sheet metal work consisting of CRCAsheets, various sections of iron, plates, chequered plates, rods, bars, MSpipes, etc. for panel board or any other purpose with bending, cutting, drillingand welding complete erected at the position with necessary materials dulypainted with one coat of red oxide and two coats of enamel paint to match theswitchgears or as per directions by the authority.
148Supplying and laying (including excavation of suitable width & depth up to 90 cm)120 mm outside dia. double wall corrugated pipes (DWC) of HDPE forenclosing cable below ground/road surface, to required depth complete.
149Supplying and laying (including excavation of suitable width & depth up to 90 cm)160 mm outside dia, double wall corrugated pipes (DWC) of HDPE forenclosing cable below ground/road surface, to required depth complete.
150Supplying and laying (including excavation of suitable width & depth up to 90 cm)200 mm outside dia, double wall corrugated pipes (DWC) of HDPE forenclosing cable below ground/road surface, to required depth complete.
151Excavating hard Rock or bituminous road by chiselling for preparing pit forpole / stay/earth plate / for laying cable/ pipe & clearing the site by removingdebris & making the site as required complete.
152Excavating hard murum / stone metal road by chiselling for preparing pit forpoles stay or earth plates or for laying cables, pipes & clearing the site byremoving debris & making the site as required complete.
153Excavating soft murum / soft soil road by chiselling for preparing pit for polesstay or earth plates or for laying cables, pipes & clearing the site by removingdebris & making the site good complete.
154Supplying & laying (including excavation) half round reinforced cementconcrete pipe of IS 458:2003 NP-2 class of 250 mm internal diameter in properline, level and slope including providing and fixing collars in cement mortar 1:2and curing etc. complete.
155Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm withfunnel with a wire mesh for watering and brick masonry block C.l. covercomplete with all materials, testing & recording the results
156Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rodcomplete with all materials testing and recording the results
157Supplying, installation and testing of maintenance free earthing comprising ofElectrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecularcopper bonded earthing rod of Length 3m along with 25 kg Carbon basedenvironment friendly back fill ground enhancing compound required to fill up theexcavated earth with required quantity complete, and recording the results
158Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnelwith a wire mesh for watering and brick masonry block C.l. cover with minimum25 kg Carbon based environment friendly back fill Ground Enhancing compoundcomplete with all materials, testing & recording the results
159Supplying and erecting GI strip of high purity required size used for earthing onwall and/or any other purpose with necessary GI clamps fixed on wall paintedwith bituminous paint with joints required.
160Service charges for Manpower of Services:
161Service charges for Manpower of Helper Services
162Service charges for Manpower of Skilled Electrician Services
163Supply and installation of Lifting tools and tackels:
164Manual chain pulley block with trolly (capacity- 5 Tonnes)
165Electrical hoist of capacity- 5 Tonnes with trolley
166Supply and installation of Steel Poles:
167Supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm diawith 4.5x3.65x3.25 mm thickness (4.5+1.75+1.75 m) length respectively andtotal 8.0 m long with pole cap, base plate in provided foundation. (weight 101 kg)
168Supply and installation of Accessories for Outdoor Fittings:
169Supplying and erecting Street light bracket for erection of Double fittingmade from 40 mm. dia ‘B’ class G.I. pipe 1.0 m. in length along with pole capof 300 mm length 100 mm dia duly welded
170Supply and installation of WIRING:
171Supplying and erecting mains with WP 2 x 6 sq. mm. 1100 V. grade aluminiumPVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWGcomplete erected with required size of porcelain reel insulators and 16 SWGG.I. binding wire.
172Supplying and erecting mains with WP 2 x 4 sq. mm. 1100 V grade aluminiumPVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWGcomplete erected with required size of porcelain reel insulators and 16 SWGG.I. binding wire.
173Point wiring in for light/fan/bell in 20 mm metal conduit with 1.5 sq.mm(2+1E) FRLSH grade copper wire, flush type switch, earthing and requiredaccessories
174Point wiring for independent plug in 20 mm metal conduit with 1.5 sq.mm(2+1E) FRLSH grade copper wire, flush type switch, earthing and requiredaccessories
175Repairing work for 20 HP Centrifugal Motor Pump set:
176Supply of Following spares for above pumpset:
177Motor Cooling Fan
178Rotter Balancing
179Best Quality grease AP 3
180Bearing Cap
181Motor Top bearing
182Motor Bottom bearing
183Motor top and bottom Shaft Welding Turning
184Oil Seal
185Bearing check - nut
186Motor housing Cover Top
187Motor housing Cover Bottom
188Motor connection plate
189Motor connection lugs
190Pump Shaft Sleeve S/S
191Pump Shaft S/S (New)
192Pump Shaft Balance
193Pump Impeller
194Impeller Neck Ring
195Impeller Balance
196Impeller diffuser
197Oil seal & Mechanical Seal
198Coupling Bush
199Repairing work for 30 HP Centrifugal Motor Pump set:
200Supply of Following spares for above pumpset:
201Motor Cooling Fan
202Rotter Balancing
203Best Quality grease AP 3
204Bearing Cap
205Motor Top bearing
206Motor Bottom bearing
207Motor top and bottom Shaft Welding Turning
208Oil Seal
209Bearing check - nut
210Motor housing Cover Top
211Motor housing Cover Bottom
212Motor connection plate
213Motor connection lugs
214Pump Shaft Sleeve S/S
215Pump Shaft S/S (New)
216Pump Shaft Balance
217Pump Impeller
218Impeller Neck Ring
219Impeller Balance
220Impeller diffuser
221Oil seal & Mechanical Seal
222Coupling Bush
223Repairing work for 40 HP Centrifugal Motor Pump set:
224Supply of Following spares for above pumpset:
225Motor Cooling Fan
226Rotter Balancing
227Best Quality grease AP 3
228Bearing Cap
229Motor Top bearing
230Motor Bottom bearing
231Motor top and bottom Shaft Welding Turning
232Oil Seal
233Bearing check - nut
234Motor housing Cover Top
235Motor housing Cover Bottom
236Motor connection plate
237Motor connection lugs
238Pump Shaft Sleeve S/S
239Pump Shaft S/S (New)
240Pump Shaft Balance
241Pump Impeller
242Impeller Neck Ring
243Impeller Balance
244Impeller diffuser
245Oil seal & Mechanical Seal
246Coupling Bush
247Repairing of 60 HP V.T Pumpset
248Removing and Dismaintling of 60 HP V.T pump set with allied equipments etc complete
249Repairing of vertical Turbine pump with turning, grinding and polishing of bowl assembly and required spares with skilled labour charges etc. complete
250Supply of Following spares for above pumpset
251Stuffing box bushing bronze
252Gland sleeve S.S.
253Rubber Bush
254Ratchet as per sample
255Neck ring bronze
256Bowl bush
257Bowl turning and surface counter and top
258Impeller
259Impeller collect
260Impeller turning
261Impeller balancing
262Top shaft S.S
263Column pipe EN - 8
264Column shaft
265Shaft sleeve
266Special strengthen Heavy Duty nut bolts for total pump set
267Rubber Packing
268Pump Foundation plate surfacing and Finishing etc. complete
269Column pipe repair with welding of ribs to MS Flange with machining etc
270coupling Socket
271Spyder
272Spyder rubber
273Pump Shaft
274Complete servicing of 60 HP V.T motor with checking insulation winding, varnishing and rotor balancing etc complete .
275Transportation of V.T Pumpset with loading and unloading by crane with too and from site etc complete
276Erection and assembling of 60 HP V.T Pumpset with bowl assembly, discharge head, coloumn pipe, line shaft with allied equipments etc complete .
277Repairing of 60 HP Motor:
278Removing and Dismaintling of 60 HP VHS type Motor with allied equipments etc complete
279Complete rewinding of motor with quality copper wire 'F' class insulation including heating, varnishing, backing and skilled labour charges etc complete with testing of site of work .
280Supply of Following spares for above pumpset
281Rotor balancing
282Cooling fan
283best quality grease Ap3
284140 No. bearing oil
285Motor top bearing
286Motor bottom bearing
287Motor bottom / top Shaft welding turning
288Oil seal
289Motor lock ratchet check lock key complete bushing S.S & etc.
290Brass pipe & Nipple etc complete
291Terminal
292Brass Lugs
293Motor housing cover top
294Motor housing cover bottom
295Bearing checknut
296Cerclip
297bearing Cap
298Transportation of motor with loading and unloading by crane with too and fromsite etc complete
299Erection and assembling of 60 HP VHS type motor with allied equipments etc complete .
300Supplying & erecting DOL starter:
3017.5 H.P.
302Supplying & erecting Star Delta Starter:
30320 H.P.
30415 H.P
305Supplying & erecting HRC fuse cartridge 415V:
30660 Amp
30780 Amp
308100 Amp
309125 Amp
310150 Amp
311200 Amp
312Supplying & replacing timer for STAR/DELTA motor starter:
313GIC Stardelta Timer
314GIC Timer SM-301
315Select 800SD
316Time Switch Timer
317Supplying and replacing thermal over load relay for motor starter:
318Relay Range 4 to 6 Amp
319Relay Range 9 to 14 Amp
320Relay Range 13 to 21 Amp
321Relay Range 45 to 75 Amp
322Supplying & erecting four pole ON LOAD change over switch, 415V, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3:
32325 AMP 415 Volt mark
32432 AMP 415 Volt ISI mark
32540 AMP 415 Volt ISI mark
32663 AMP 415 Volt ISI mark
327125 AMP 415 Volt ISI mark
328200 AMP 415 Volt ISI mark
329Repairing of motor starter (Rate quoted per HP of pump) Please Enable Macros to View BoQ information

Other Detail

Information Source https://mahatenders.gov.in
Download FileName File Description File Size
Download 57d0c3b9-c7b8-4327-b1a7-a7d8c43b13d3.html Tender Documents 0 KB
Download BOQ_2219071.xls Tender Documents 0 KB
Download ELECTRICTENDERPAPER.pdf Tender Documents 0 KB
Download Tendernotice_1 (10).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.