Indian Tenders

Tender Notice

TDR 54861871
Tendering Authority Military Engineer Services
Tender No GE(AF)/ADM/T-75 OF 2025-26
Tender ID 2025_MES_746704_2
Tender Brief Tender For Provision Of Standby Three Phase Power Supply From Existing Dg Sets To Certain Blast Pens At Af Stn Ad Ur
City Jalandhar
State Punjab
Document Fees INR 500 /-
EMD INR 89920.0 /-
Tender Value INR 44.96 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Provision Of Standby Three Phase Power Supply From Existing Dg Sets To Certain Blast Pens At Af Stn Ad Ur

Key Dates

Publish Date 27-03-2026
Last Date of Bid Submission 13-04-2026
Tender Opening Date 15-04-2026

Contact Information

Company Name Military Engineer Services
Contact Person GE (AF) Adampur
Address GE (AF) Adampur

BOQ Items

Name of Work:- PROVISION OF STANDBY THREE PHASE POWER SUPPLY FROM EXISTING DG SETS TO CERTAIN BLAST PENS AT AF STN AD UR
Sl. No. Item Description
1Taking out old unserviceable LT UG Cable of any sizes/capacity, complete all as specified and directed
2M&L for shifting of existing DG Set 100 KVA capacity of make Kirloskar from 47 Sqn power room to sun shelter power room (approx. 250 metre distance) including removal of existing cable and re-connecting new cable (approx length 10m) complete all as specified and as directed.
3Excavation in trenches n. exc 1.5 metre wide for taking out/ laying pipe line, cable, foundation etc. not exc exceeding 1.5 metre deep and getting out as in soft/ loose soil complete all as specified and directedNOTES : Excavation work will be carried out by contractor manually and very carefully without endangering existing AFNET/ cables, pipe lines and adjoining structures, if any. In case any damage is caused, the same shall be made good by the contractor without any extra cost to the Govt.
4M&L for Clean dry sand ( locally available) as cushioning for under ground cable 230 mm thick (one layer of 80 mm thickness before laying the cable and other layer of 150 mm thickness after laying the cable) complete all as specified and directed.NOTE:- Punned down thickness (over all 180 mm) shall be considered for measurement and payment.
5Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
6Removal of excavated surplus spoil to a distance n. exc. 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified and directed.
7Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 flat, size 250 mm x 150mm x 40mm complete all as specified and as directed.
8Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 core complete all as specified and as directed.
9Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 core complete all as specified and as directed.
10Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 core complete all as specified and as directed.
11Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 core complete all as specified and as directed.
12Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 core complete all as specified and as directed.
13Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all specified and directed.
14Design, fabricate, supply ,install, testing and commissioning of LT panel outdoor type 415 Volts, 50 Hz, 3 phase, 4 wire totally enclosed self supporting structure fully compartmentalized, with sloping canopy, suitable for outdoor use with bottom cable entry with suitable cable glands, made out of CRCA sheet 3.15mm thick with angle iron frame works with suitable legs of ISA 50x50x5mm with four legs grouted PCC (1:2:4) type B1 foundation block pedestal of 30cm height from ground level with suitable nuts, bolts and washers etc. detachable plate shall be provided at the bottom of the panel with necessary holes suitable for termination of various sizes of cables with glands, with suitable mounting arrangement for aluminium bus bars 400 Amps capacity, suitable size copper wire for internal power and control wiring, hinged door at front with suitable locking arrangement, provision of air vent at both sides, double door, both side openable, CPRI approved, dust and vermin proof, powder coated for accommodating the following accessories and as incoming/outgoing switchgears complete all as specified and directed :-(a) MCCB 250 Amp, 4 Pole, 415 V, 50 Hz with rupturing capacity 36 KA- 1 Nos (Incoming)(b) MCCB 200 Amp, 4 Pole, 415 V, 50 Hz with rupturing capacity 25 KA- 1 Nos (Outgoing)(c) MCCB 63 Amp, 4 Pole, 415 V, 50 Hz with rupturing capacity 16 KA- 1 Nos (Outgoing)(d) Digital Volt meter with selector switch (0-500 V)-01 No(e) Digital Ammeter with selector switch-01 No(f) CT's 400/5- set of 3 No(g) LED Indication lamps (RYB)-one set
15Design, fabricate, supply ,install, testing and commissioning of LT panel outdoor type 415 Volts, 50 Hz, 3 phase, 4 wire totally enclosed self supporting structure fully compartmentalized, with sloping canopy, suitable for outdoor use with bottom cable entry with suitable cable glands, made out of CRCA sheet 3.15mm thick with angle iron frame works with suitable legs of ISA 50x50x5mm with four legs grouted PCC (1:2:4) type B1 foundation block pedestal of 30cm height from ground level with suitable nuts, bolts and washers etc. detachable plate shall be provided at the bottom of the panel with necessary holes suitable for termination of various sizes of cables with glands, with suitable mounting arrangement for aluminium bus bars 300 Amps capacity, suitable size copper wire for internal power and control wiring, hinged door at front with suitable locking arrangement, provision of air vent at both sides, double door, both side openable, CPRI approved, dust and vermin proof, powder coated for accommodating the following accessories and as incoming/outgoing switchgears complete all as specified and directed :-(a) MCCB 200 Amp, 4 Pole, 415 V, 50 Hz with rupturing capacity 25 KA- 1 Nos (Incoming)(b) MCCB 100 Amp, 4 Pole, 415 V, 50 Hz with rupturing capacity 25 KA- 1 Nos (Outgoing)(c) MCCB 63 Amp, 4 Pole, 415 V, 50 Hz with rupturing capacity 16 KA- 1 Nos (Outgoing)(d) Digital Volt meter with selector switch (0-500 V)-01 No(e) Digital Ammeter with selector switch-01 No(f) CT's 400/5- set of 3 No(g) LED Indication lamps (RYB)-one set
16Design, fabricate, supply ,install, testing and commissioning of LT panel outdoor type 415 Volts, 50 Hz, 3 phase, 4 wire totally enclosed self supporting structure fully compartmentalized, with sloping canopy, suitable for outdoor use with bottom cable entry with suitable cable glands, made out of CRCA sheet 3.15mm thick with angle iron frame works with suitable legs of ISA 50x50x5mm with four legs grouted PCC (1:2:4) type B1 foundation block pedestal of 30cm height from ground level with suitable nuts, bolts and washers etc. detachable plate shall be provided at the bottom of the panel with necessary holes suitable for termination of various sizes of cables with glands, with suitable mounting arrangement for aluminium bus bars 150 Amps capacity, suitable size copper wire for internal power and control wiring, hinged door at front with suitable locking arrangement, provision of air vent at both sides, double door, both side openable, CPRI approved, dust and vermin proof, powder coated for accommodating the following accessories and as incoming/outgoing switchgears including dismantling old complete all as specified and directed :-(a) MCCB 100 Amp, 4 Pole, 415 V, 50 Hz with rupturing capacity 25 KA,- 1 Nos (b) MCCB 63 Amp, 4 Pole, 415 V, 50 Hz with rupturing capacity 16 KA- 2 Nos (Outgoing)(c) Digital Volt meter with selector switch (0-500 V)-01 No(d) Digital Ammeter with selector switch-01 No(e) CT's 400/5- set of 3 No(f) LED Indication lamps (RYB)-one set
17M&L for earthing complete with galvanized steel earth plate electrode 600x600x6.0 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) normal with top edge of plate not less than 1.5 m below normal ground level, earth plate connected to galvanized earth strip 32 x 6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES SSR part I connected to earth test point all as specified or indicated including testing on completion with and including 15mm bore light grade GI protector pipe 7.5 meter long for earth wire including PCC (1:2:4) pit with precast RCC (1:2:4) type B-1 cover, 40mm thick reinforced with 6 mm dia MS bars @ 100 mm both ways with lifting hooks made out of 6mm dia MS bars, watering arrangement with funnel, wire common slat charcoal filling, necessary excavating and earth work in any type of soil complete all as specified.
18Material and labour, plain cement concrete (1:3:6) type C-2 using 40mm graded crushed stone aggregate, for foundation of poles, etc., complete all as specified and directed.
19Note : Amount of credit for retrieved materials is mentioned in Sch 'A' Section-II of tender documents in pdf form which will be deducted while acceptance of tender offline. Please Enable Macros to View BoQ information

Other Detail

Information Source https://defproc.gov.in/nicgep/app
Download FileName File Description File Size
Download BOQ_849072.xls Tender Documents 0 KB
Download eff8e423-fd39-44ee-8e04-97ff0ff0dfe7.html Tender Documents 0 KB
Download tender.pdf Tender Documents 0 KB
Download Tendernotice_1 (2).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.