Indian Tenders

Tender Notice

TDR 54854599
Tendering Authority Public Works Department
Tender No PWD/2025-26/IND0217
Tender ID PWD/2025-26/IND0217
Tender Brief Tender for Providing a 2000 Ltr capacity backup hot-water system for Harapanahalli Town Government Hospital Block B building 2000 Ltr capacity 3000 Ltr capacity hot-water system for the Community Health Centre CHC of villages under Harapanahalli Talu
City Hosapete
State Karnataka
Document Fees INR 5000 /-
EMD INR 300000.0 /-
Tender Value INR 2 Crore /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Providing A 2000 Ltr Capacity Backup Hot-Water System For Harapanahalli Town Government Hospital Block B Building 2000 Ltr Capacity 3000 Ltr Capacity Hot-Water System For The Community Health Centre Chc Of Villages Under Harapanahalli Taluk 3000 Ltr Capacity And Providing A 3000 Ltr Capacity Hot Water Systemfor The Primary Health Centre Phc 3000Ltrcapacity Along With A 24X7 Hot Water Supply System.Work Includes Supply, Installation And Commissioning Of Integrated Air Source Heat Pump & Hot Water Storage Tank Turnkey Basis - Misscelaneous And Rounding Off200,Heatpump 3000 Ltr 2000 Ltr Gst 18 Percent,Heatpump 3000 Ltr 2000 Ltr Add Third Party Inspection Charges,Supply Of Soften Water Softener Triple Cylinder 3000 Ltr Hr It Is Designed To Provide Consistent Soft Water Output The System Comprises A 13 70 Water Softener Vessel Mpv Manual Head Filter Mpv Manual Head Softener Filter Bottom Strainer And Top Strainer For Efficient Filtration It Is Equipped With A 1Pvc Pipe Pressure Gauge And A 200 Ltr Storage Tank To Support Smooth Operation The Media Package Consists Of 150 Kg Of 8 Mm Sand 150 Kg Of 4Mm Sand 175 Kg Of Activated Carbon And 200 L,Supply Of Mounting Bracket Structure For Heat Pumps Circulation Pumps And Control Panel Made Out Of Mild Steel Structure Finishing With 1 Coat Of Zinccromate Oxide And 2 Coat Of Enamel Paint For Corrosion Resistant And Anti Vibration Bushes And Ss Fasteners For Air Source Heat Pump Water Heater Circulation Pump And Control Panel High Strength Heavy Often Used For Industrial/Heavy-Duty Applications,Supply Of Integrated Electrical Control Panel (Outdoor) With Energy Meter For Air Source Heat Pump Water Heaters And Circulation Pumps. Outdoor Control Panel ( Ip 65 ) Incomer Power Supply Control High / Low Voltage And Current Protection Voltage / Power 380V/3N/50Hz 3000Ltr,Supply Of Circulation Pump Between Air Source Heat Pump Water Heater & Hot Water Mixing Tank (1W + 1S) Make Grundfos/Cnp Power (V/Ph/Hz) 380V/3N/50Hz 3000Ltr,Hot Water Inner Storage Tank Thickness Of 4 Mm Shell & 5 Mm Dish, Made Out Of Mild Steel, Inner Tank Coating Finished With 150 -200 Microns Pure Glassy Epoxy Based Enamel Coat For Corrission Resistance Withstanding Temperature Up To 120°C. Tank Tare Weight Approx. 650 Kgs, Tank Height 1500 Mm, Tank Length 3000 Mm Purpose Of Hot Water Usage Bathing Purpose 3000Ltr,Rated Heating Input Power 3.5 Kw Rated Heating Output Power 15 Kw Rated Input Current Max 9A Rated Heated Water Output 350 -400 Ltr/Hr Voltage / Power 380 415V/3Ph/50Hz Rated Output Water Temperature 55 C Max Output Water Temperature 60 C,Transportation Two Boom Hydraulic Drill Jumbo 3000Ltr,Lifting Heat Pumps, Tank, Circulation Pumps, Shelter Work Materials And Other Accessories Crane With Grab 0.75 M3 Capacity 3000Ltr,Internal & External Electrical Led Bulb 3000Ltr,Electrical Insulatioin Tape 3000Ltr,Internal & External Electrical Cable With Material Between Air Source Heat Pump Water Heater, Circulation Pump And Control Panel Including Cable Tray And Supporting Lamp Holder 3000Ltr,Internal & External Electrical Cable With Material Between Air Source Heat Pump Water Heater, Circulation Pump And Control Panel Including Cable Tray And Supporting 16A Switch 3000Ltr,Internal & External Electrical Cable With Material Between Air Source Heat Pump Water Heater, Circulation Pump And Control Panel Including Cable Tray And Supporting 16A Socket 3000Ltr,Internal & External Electrical Cable With Material Between Air Source Heat Pump Water Heater, Circulation Pump And Control Panel Including Cable Tray And Supporting 25 Mm 4 Junction Box 3000Ltr,Internal & External Electrical Cable With Material Between Air Source Heat Pump Water Heater, Circulation Pump And Control Panel Including Cable Tray And Supporting 19 Mm Junction Box 19 Mm Junction Box,Internal & External Electrical Cable With Material Between Air Source Heat Pump Water Heater, Circulation Pump And Control Panel Including Cable Tray And Supporting 19 Mm Rcc Pipe 3000Ltr,Internal & External Electrical Cable With Material Between Air Source Heat Pump Water Heater, Circulation Pump And Control Panel Including Cable Tray And Supporting 25 Mm Rcc Pipemtr,Internal & External Electrical Cable With Material Between Air Source Heat Pump Water Heater, Circulation Pump And Control Panel Including Cable Tray And Supporting.1 Sq Mm Copper Wire Black 32 A, 3/4 Pole 3000Ltr,Internal & External Electrical Cable With Material Between Air Source Heat Pump Water Heater, Circulation Pump And Control Panel Including Cable Tray And Supporting.1 Sq Mm Copper Wire Black 1Sqmm,Internal & External Electrical Cable With Material Between Air Source Heat Pump Water Heater, Circulation Pump And Control Panel Including Cable Tray And Supporting.1 Sq Mm Copper Wire Red 1 Sq Mm,Internal & External Electrical Cable With Material Between Air Source Heat Pump Water Heater, Circulation Pump And Control Panel Including Cable Tray And Supporting.1.5 Sq Mm Copper Wire 1.5Sqmm,Internal & External Electrical Cable With Material Between Air Source Heat Pump Water Heater, Circulation Pump And Control Panel Including Cable Tray And Supporting.2.5 Sq Mm Copper Wire 2.5Sqmm,Internal & External Electrical Cable With Material Between Air Source Heat Pump Water Heater, Circulation Pump And Control Panel Including Cable Tray And Supporting.4 Sq Mm Copper Wire 4Sqmm,Internal & External Electrical Cable With Material Between Air Source Heat Pump Water Heater, Circulation Pump And Control Panel Including Cable Tray And Supporting(3000Ltr) 6Sqmm,Internal & External Electrical Cable With Material Between Air Source Heat Pump Water Heater, Circulation Pump And Control Panel Including Cable Tray And Supporting(3000Ltr),Providing And Placing On Terrace At All Floor Levels Polyethylene Water Storage Tank, Is 12701 Marked, With Cover And Suitable Locking(3000Ltr),Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge (3000Ltr)40Mm,Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge (3000Ltr),Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. Internal Work (3000 Ltr),Internal & External Plumbing Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. Internal Work - Exposed On Wall (3000Ltr),Position Plain Cement Concrete For Levellingcourse For All Works In Foundation Mix 1 3 6(M10) Using 20Mm Nominal Size Graded Crushed Coarse Aggregate. The Granite/Trap/Basalt Crushedgraded Coarse Aggregates And Fine Aggregates As Per Relevant Iscodes Machine Mixed, Laid In Layers Not Exceeding 150 Mm Thickness And All The Other Appurtenances Required To Complete The Work As Per Technical Specifications. (The Cost Of Steel Reinforcement & Formwork Shall Be Paid Separately For Column,Providing And Fixing Precoated Galvanised Iron Profile Sheetssheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 M Or As Desired By Engineerin- Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trussesand Including,Providing And Fixing Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. Hot Finished Seamless Type Tubes Including Cost Of Materials Labour Usage Charges Of Machinery Complete As Per Specifications And As Per Directions Of The Engineer In Charge,Supply Of Soften Water Softener Double Cylinder 2000 Ltr/Hr It Is Designed To Provide Consistent Soft Water Output. The System Comprises A 13/60 Water Softener Vessel, Mpv Manual Head Filter, Mpv Manual Head Softener Filter, Bottom Strainer, And Top Strainer For Efficient Filtration.,Supply Of Mounting Bracket Structure For Heat Pumps, Circulation Pumps And Control Panel Made Out Of Mild Steel Structure Finishing With 1 Coat Of Zinccromate Oxide And 2 Coat Of Enamel Paint For Corrosion Resistant And Anti Vibration Bushes And Ss Fasteners For Air Source Heat Pump Water Heater, Circulation Pump And Control Panel. High Strength, Heavy, Often Used For Industrial/Heavy-Duty Applications.,Supply Of Integrated Electrical Control Panel (Outdoor) With Energy Meter For Air Source Heat Pump Water Heaters And Circulation Pumps. Outdoor Control Panel ( Ip 65 ), Incomer Power Supply Control, High / Low Voltage And Current Protection. Voltage / Power 380V/3N/50Hz,Supply Of Circulation Pump Between Air Source Heat Pump Water Heater Hot Water Mixing Tank (1W 1S Make Grundfos/Cnp Power (V/Ph/Hz) 380V/3N/50Hz.,Hot Water Inner Storage Tank Thickness Of 4 Mm Shell & 4 Mm Dish, Made Out Of Mild Steel, Inner Tank Coating Finished With 150 -200 Microns Pure Glassy Epoxy Based Enamel Coat For Corrission Resistance Withstanding Temperature Up To 120°C. Tank Tare Weight Approx. 450 Kgs, Tank Height 1300 Mm, Tank Length 2250 Mm Purpose Of Hot Water Usage Bathing Purpose. Quotation Rate Approved By,Rated Heating Input Power 2.7 Kw Rated Heating Output Power 11.4 Kw Rated Input Current Max 7A Rated Heated Water Output 250 -300 Ltr/Hr Voltage / Power 380 415V 3Ph 50Hz Rated Output Water Temperature 55 C Max Output Water Temperature 60 C,Transportation Two Boom Hydraulic Drill Jumbo,Lifting Heat Pumps, Tank, Circulation Pumps, Shelter Work Materials And Other Accessories Crane With Grab 0.75 M3 Capacity,Internal & External Electrical Led Bulb,Electrical Insulatioin Tape,Internal & External Electrical Cable With Material Between Air Source Heat Pump Water Heater, Circulation Pump And Control Panel Including Cable Tray And Supporting Lamp Holder,Internal & External Electrical Cable With Material Between Air Source Heat Pump Water Heater, Circulation Pump And Control Panel Including Cable Tray And Supporting 16A Switch,Internal & External Electrical Cable With Material Between Air Source Heat Pump Water Heater, Circulation Pump And Control Panel Including Cable Tray And Supporting 16A Socket,Internal & External Electrical Cable With Material Between Air Source Heat Pump Water Heater, Circulation Pump And Control Panel Including Cable Tray And Supporting 25 Mm 4 Junction Box,Internal & External Electrical Cable With Material Between Air Source Heat Pump Water Heater, Circulation Pump And Control Panel Including Cable Tray And Supporting 19 Mm Junction Box,Internal & External Electrical Cable With Material Between Air Source Heat Pump Water Heater, Circulation Pump And Control Panel Including Cable Tray And Supporting 19 Mm Rcc Pipe,Internal & External Electrical Cable With Material Between Air Source Heat Pump Water Heater, Circulation Pump And Control Panel Including Cable Tray And Supporting 25 Mm Rcc Pipe,Internal & External Electrical Cable With Material Between Air Source Heat Pump Water Heater, Circulation Pump And Control Panel Including Cable Tray And Supporting.1 Sq Mm Copper Wire Black 32 A, 3/4 Pole,Internal & External Electrical Cable With Material Between Air Source Heat Pump Water Heater, Circulation Pump And Control Panel Including Cable Tray And Supporting.1 Sq Mm Copper Wire Black,Internal & External Electrical Cable With Material Between Air Source Heat Pump Water Heater, Circulation Pump And Control Panel Including Cable Tray And Supporting.1 Sq Mm Copper Wire Red,Internal & External Electrical Cable With Material Between Air Source Heat Pump Water Heater, Circulation Pump And Control Panel Including Cable Tray And Supporting.1.5 Sq Mm Copper Wire,Internal & External Electrical Cable With Material Between Air Source Heat Pump Water Heater, Circulation Pump And Control Panel Including Cable Tray And Supporting.2.5 Sq Mm Copper Wire,Internal & External Electrical Cable With Material Between Air Source Heat Pump Water Heater, Circulation Pump And Control Panel Including Cable Tray And Supporting.4 Sq Mm Copper Wire,Internal & External Electrical Cable With Material Between Air Source Heat Pump Water Heater, Circulation Pump And Control Panel Including Cable Tray And Supporting,Internal & External Electrical Cable With Material Between Air Source Heat Pump Water Heater, Circulation Pump And Control Panel Including Cable Tray And Supporting Structures,Providing And Placing On Terrace At All Floor Levels Polyethylene Water Storage Tank, Is 12701 Marked, With Cover And Suitable Locking.,Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge.,Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. Internal Work,Internal & External Plumbing Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. Internal Work - Exposed On Wall,Position Plain Cement Concrete For Levellingcourse For All Works In Foundation Mix 1 3 6(M10) Using 20Mm Nominal Size Graded Crushed Coarse Aggregate. The Granite/Trap/Basalt Crushedgraded Coarse Aggregates And Fine Aggregates As Per Relevant Iscodes Machine Mixed, Laid In Layers Not Exceeding 150 Mm Thickness And All The Other Appurtenances Required To Complete The Work As Per Technical Specifications. (The Cost Of Steel Reinforcement & Formwork Shall Be Paid Separately,Providing And Fixing Precoated Galvanised Iron Profile Sheetssheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 M Or As Desired By Engineerin- Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trussesand Including Cutting,Providing And Fixing Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. Hot Finished Seamless Type Tubes Including Cost Of Materials, Labour, Usage Charges Of Machinery Complete As Per Specifications And As Per Directions Of The Engineer-In-Charge

Key Dates

Publish Date 18-03-2026
Last Date of Bid Submission 27-03-2026
Tender Opening Date 30-03-2026

Contact Information

Company Name Public Works Department
Contact Person Executive Engineer
Address Office Of the Executive Engineer, PWD Division, Behind S.P Office,Dam Road, Hosapete

Other Detail

Information Source https://kppp.karnataka.gov.in
Download FileName File Description File Size
Download 7637720c-8f38-49ea-9735-9f8cbce6a5d7.html Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.