Indian Tenders

Tender Notice

TDR 54849170
Tendering Authority Greater Noida Industrial Development Authority
Tender No PROJECT/WC-EM-3/2026/03-04 DATED-20.03.2026
Tender ID 2026_GNIDA_1130147_1
Tender Brief Corrigendum : Tender For Supply, Installation, Testing, Commissioning, Operations And Maintenance (Sitcom) Of Integrated Security And Traffic Management System (Ismts) In, Greater Noida City
City Gautam Buddha Nagar
State Uttar Pradesh
Document Fees INR 6770 /-
EMD INR 23760000.0 /-
Tender Value INR 227.60 Crore /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender For Supply, Installation, Testing, Commissioning, Operations And Maintenance (Sitcom) Of Integrated Security And Traffic Management System (Ismts) In, Greater Noida City

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 22-04-2026 REVISED SCHEDULE Date 20-05-2026

Key Dates

Publish Date 22-04-2026
Last Date of Bid Submission 20-05-2026
Tender Opening Date 22-05-2026

Contact Information

Company Name Greater Noida Industrial Development Authority
Contact Person SM_EM-3
Address GNIDA OFFICE

BOQ Items

Name of Work:- Supply, Installation, Testing, Commissioning, Operations and Maintenance (SITCOM) of Intergrated Security and Traffic Management System (ISMTS) in, Greater Noida City
Sl. No. Item Description
1Hardware - Field Components
2IP Outdoor 2MP PTZ Camera, min 30X optical 10 X digital Zoom (IP 66 housing, 24VAC/POE+, 128 GB SD Card, Surge Protection Devices, all type of Cables mounting bracket with Bird spikes and all required accessories).
3IP Fixed 4MP HD Camera with IP 66 rated housing for outdoor use, 128 GB SD Card, Surge Protection devices, Mounting Bracket, Bird Spikes, all type of cables with all required accessories
4Galvanized Iron (GI) Standard Poles for Surveillance Cameras and PA system (minimum height of 6.5 Meters) as per industrial standards and government norms / guidelines, 160Kmph wind speed bearing capacity, load bearing capacity of minimum 15KG with foundation, fasteners / bolts, (complete in all respects including rust protection, Paint, civil work and earthing, structural design and material composition test certificate) as per Solution requirement
5IP Fixed BOX 2MP HD Box ANPR cameras with IP 66 rated housing, 128 GB SD Card, Surge Protection Devices, Mounting Brackets, Bird Spikes, all type of cables with all required accessories
6Galvanized Iron (GI) Cantilever poles at traffic junctions for ANPR cameras and IR Illuminators (minimum height of pole 6.5 Meters) as per industrial standards and government norms / guidelines, for ground clearance of 6 meters, 160Kmph wind speed bearing capacity, load bearing capacity of minimum 15KG with foundation, fasteners / bolts, (complete in all respects including rust protection, Paint, civil work and earthing, structural design and material composition test certificate) as per Solution requirement
7IP Fixed 2MP HD RLVD Camera with IP 66 rated housing for outdoor use, 128 GB SD Card, Surge Protection devices, Mounting Bracket, Bird Spikes, all type of cables with all required accessories
8External IR Illuminators for ANPR cameras with all type of cables and all required accessories. Min. 80 meters or better, adjustable angle to cover the complete field of view at specified locations for higher accuracy in performance. Power 70 – 100 W
9Industrial LPU with minimum Intel i7 Processor, 12th Generation or better for ANPR, RLVD, SVD & Traffic applications and Video Analytics (15 days SSD storage) with all type of cables and all required accessories
10Speed Detection Device 4 lane including both LHS and RHS capable to detect speed more than 200 kmph, complete in all aspect including 4D Radar, ANPR (Global Shutter) camera, 128 GB SD Card, Surge Protection Devices, MCB, Earthing, Speed & ANPR Licenses, Mounting Structure (Gantry/Cantilever), Field Switch, LPU, IR illuminator, all type of cables etc. and all required accessories) as per solution requirement (As per FRS and TRS, Volume II B)
11Speed Detection Device 6 lane including both LHS and RHS capable to detect speed more than 200 kmph, complete in all aspect including 4D Radar, ANPR (Global Shutter) camera, 128 GB SD Card, Surge Protection Devices, MCB, Earthing, Speed & ANPR Licenses, Mounting Structure (Gantry), Field Switch, LPU, IR illuminator, all type of all type of cables and all required accessories) as per solution requirement (As per FRS and TRS, Volume II B)
12Adaptive Traffic Control System (ATCS) Traffic light Controllers with 32 cycle plan , minimum 20 cycle switch per day Junction Box and all Controller modules and accessories. All type of all type of Cables, and all required accessories as per Solution Requirement (As per FRS and TRS, Volume II B)
13Optical / Thermal video-based Vehicle Detector devices for general surveillance and evidence/RLVD image capturing. The VTDS System at any point of time, shall provide different classification levels viz. 2-wheeler, 3-Wheeler/ Autorickshaws, e-rikshaw, SCV, LMV, HMV at any given point in time. All type of all type of Cables, and all required accessories as per Solution Requirement (As per FRS and TRS, Volume II B)
14Traffic Light Aspects - Operating voltage voltage of ‐ 12 / 24 DC / 230VAC, high power SMD LEDs in ceramic package with silicone lens, IP65, Fresnel & Coloured Distribution Lens, Fuse and Transients shall be available, Turn Off/Turn On Time: 100 milli seconds max, Minimum Luminous Intensity (measured at intensity point)(cd): Red 400, Amber 400, Green 400, Protection for current voltages spikes for all the below mentioned colours of traffic light aspects, with all required accessories as per solution requirement (A15 to A19) (As per FRS and TRS, Volume II B)
15Traffic Signal Aspects - Red
16Traffic Signal Aspects - Amber
17Traffic Signal Aspects - Green Arrow
18Traffic Signal Aspects - Pedestrian Red
19Traffic Signal Aspects - Pedestrian Green
20Galvanized Iron (GI) single arm cantilever poles for (minimum height of 6.5 Meters) as per industrial standards and government norms / guidelines, for ground clearance of 6.5 meters, 160Kmph wind speed bearing capacity, load bearing capacity of minimum 25KG for traffic light aspects, Speed Detection Devices (4D Radar), ANPR cameras and IR Illuminators with foundation, fasteners / bolts, (complete in all respects including rust protection, Paint, civil work and earthing, structural design and material composition test certificate) as per Solution requirement
21Galvanized Iron (GI) standard poles (minimum height of 4 meters) as per industrial standards and government norms / guidelines, 160Kmph wind speed bearing capacity, load bearing capacity of minimum 25KG for traffic light aspects with foundation, fasteners / bolts, (complete in all respects including rust protection, Paint, civil work and earthing, structural design and material composition test certificate) as per Solution requirement
22Vehicular Adaptive Countdown Timer (ACDT) for ATCS Junctions, 320 x 320 mm (min), RGB panel to display Red, Green & Amber perfectly, 12/24V DC or 230V AC ~ 50Hz, viewing angle minimum Horizontal >160° Vertical >140°, IP 65, Shall be able to dynamically show timings by direct interfacing from the controller, with all required accessories as per solution requirement (As per FRS and TRS, Volume II B)
23Pedestrian Count Down Timer for ATCS Junctions, 300mm (min), Dual Colored (Red & Green), 12/24V DC or 230V AC ~ 50Hz, viewing angle minimum 23° to 30° , IP 65, Shall be able to dynamically show timings by direct interfacing from the controller, with all required accessories as per solution requirement
24Outdoor Variable Message Signboards / Displays Minimum size 2.8 m x 1.9m , Pixel Pitch 7 mm or better, Min 22000 pixels per sqm or higher, brightness- 5500 cd/m² or better, power consumption - 850 w/sqm or lower, 100 ~ 240 VAC power input, Front and rear IP65 Complete in all respects, including MCB, 6 KVA UPS for 30 mins backup, Surge Protection Devices, all type of Cables, Earthing, etc. with all required accessories as per solution requirement as per Solution Requirement. (As per FRS and TRS, Volume II B)
25Mounting Structure for Variable Message Signboard / Display, Considering height clearance as per Government Guidelines, 160Km/hour wind speed bearing capacity, with foundation, fasteners / bolts (complete in all respects including paint, civil work and earthing, structural design and material composition test certificate) as per Solution Requirement Suitable for above mentioned Variable Messaging Signboard (Size 2.8 x 1.9 Mtrs)
26Outdoor Variable Message Signboards / Displays Minimum size 3.8 m x 1.9m , Pixel Pitch 7 mm or better, Min 22000 pixels per sqm or higher, brightness- 5500 cd/m² or better, power consumption - 850 w/sqm or lower, 100 ~ 240 VAC power input, Front and rear IP65 Complete in all respects, including MCB, 8 KVA UPS for 30 min.s backup, Surge Protection Devices, Cables, Earthing, Field Switch, Junction box etc. as per Solution Requirement (As per FRS and TRS, Volume II B)
27Mounting Structure for Variable Message Signboards / Displays, Considering height clearance as per Government Guidelines, 160Km/hour wind speed bearing capacity, with foundation, fasteners / bolts (complete in all respects including paint, civil work and earthing, structural design and material composition test certificate) as per Solution Requirement Suitable for above mentioned Variable Messaging Signboard (Size 3.8 x 1.9 Mtrs)
28PA System for Public announcement system for outdoor use, Minimum 4 Speakers at each location with 30 W capacity each, 50Hz to 15000 Hz for Amplifier, IP amplifier with minimum 250 Watts, Class D. Redundant power supply provision inbuilt in Amplifier, Main power supply: 100 – 240 VAC, with Central Software based server application capable of working with 100% redundancy
29Emergency call box (ECB), ethernet connectivity, IP66 / IP65, IK09 Protection, Speaking Distance minimum 5 ft, Inbuilt Amplifier, Minimum 3 Inputs ad 2 Output relay contacts, Call Button: Watertight, Push Button, Visual Feedback for button press and call indication with acoustic hood to filter background noise with its Application-Two way communication
30Galvanized Iron (GI) Standard Pole for ECB (minimum height of 2.5 Meters) as per industrial standards and government norms / guidelines, 160Kmph wind speed bearing capacity, load bearing capacity of minimum 25KG with foundation, fasteners / bolts, (complete in all respects including rust protection, Paint, civil work and earthing, structural design and material composition test certificate) as per Solution requirement
31Ground mountable Main Junction Box IP 55 Outdoor. Thickness ranges minimum 1.5mm, 15U rack or more as per site requirement with load bearing capacity of 40KG or more and one-fold door type. 3 point high quality locking system with compression manual Lock to accommodate Power Supply, UPS, Network Switch other field equipment with Earthing. (As per FRS and TRS, Volume II B)
32Pole mountable Distribution Junction Box IP 55 Outdoor, Thickness ranges minimum 1.2mm, one-fold door type. 3 point high quality locking system with compression manual Lock to accommodate LPU, Switches etc. with Earthing.
33Online UPS, Pure Sine wave IGBT based PWM Technology, output voltage 208 /200/ 220VAC /230VAC. BIS standard, CE Certified, ROHS Certified, Govt. of India EPR (E-Waste) certification. There shall be min 6 AMP x 3 Nos./ 5 AMP x 2 Nos./ Terminals as per OEM STD with 1 KVA load rating to provide 1 hour power backup to all the connected devices with Surge Protection, Earthing and required accessories. (As per FRS and TRS, Volume II B)
34Online UPS, Pure Sine wave IGBT based PWM Technology, output voltage 208 /200/ 220VAC /230VAC. BIS standard, CE Certified, ROHS Certified, Govt. of India EPR (E-Waste) certification. There shall be min 6 AMP x 3 Nos./ 5 AMP x 2 Nos./ Terminals as per OEM STD with 1.5 KVA load rating to provide 1 hour power backup to all the connected devices with Surge Protection, Earthing and required accessories. (As per FRS and TRS, Volume II B)
35Online UPS, Pure Sine wave IGBT based PWM Technology, output voltage 208 /200/ 220VAC /230VAC. BIS standard, CE Certified, ROHS Certified, Govt. of India EPR (E-Waste) certification. There shall be min 6 AMP x 3 Nos./ 5 AMP x 2 Nos./ Terminals as per OEM STD with 2.0 KVA load rating to provide 1 hour power backup to all the connected devices with Surge Protection, Earthing and required accessories. (As per FRS and TRS, Volume II B)
36Edge level (Field) 24 Port (PoE) Industrial Grade Managed network switch with Power Supply, 24 X 10M/100M/1G RJ45 POE Port ,4 X 1G SFP Port , 1 X RJ45 console port, SFP and other accessories at each main junction Box as per Solution Requirement
37Edge level (Field) 16 Port (PoE) Industrial Grade Managed network switch with Power Supply, 16 X 10M/100M/1G RJ45 POE Port , 2 X 1G SFP , 1 X RJ45 console port, SFP and other accessories at each main junction Box as per Solution Requirement
38Edge level (Field) 8 Port (PoE) Industrial Grade Managed network switch with Power Supply, 8 x 10/100/1000Base‐T Ports POE + 2 x 1G SFP slot + 1 Console Ports, SFP and other accessories at each main junction Box as per Solution Requirement (As per FRS and TRS, Volume II B)
39Edge level (Field) 4 Port (PoE) Industrial Grade Managed network switch with Power Supply, 4 x 10/100/1000Base‐T Ports POE + 2 SFP Slots + 1 Console Port, SFP and other accessories at each main junction Box as per Solution Requirement (As per FRS and TRS, Volume II B)
40Cautionary, Warning and Informatory Road signages (Like U-turn Prohibited, Roundabout, Speed limit, No parking, traffic signal ahead, Pedestrian Crossing, under surveillance etc.) - Shape: Circular/ Triangular / Square, Background: White, Border: Red Symbol/Letter: As per government guidelines, Complete with Civil work with 3 mtrs of GI standard pole, wind bearing capacity of 160Kmph, Load bearing Capacity of 5Kg, Complete with rust protection, paint, fixtures in all respects
41Workstation Desktop with 1 monitor, intel i7, min. 16 GB RAM, 8 GB Graphic Card including minimum 20 Meter HDMI/ DVI/ DP cables
42Workstation Desktop with 4 monitor, intel i7, min. 16 GB RAM, 8 GB Graphic Card including minimum 20 Meter HDMI/ DVI/ DP cables (9 for SSP office, 3 for HO )
4365\\" Smart LED Display / TV, Full HD with WiFi and Bluetooth for SSP office and HO)
4440\\" Smart LED Display / TV, Full HD with WiFi and Bluetooth for SSP office and HO)
45UAVs, rotorcraft / VTOL fixed-wing drones for ariel surveillance (As per technical specification mentioned in Volume IIB)
46Pink booth with civil work including following components1 no. 2 KVA Invertor with minimum 1 hour backup1 no. RO Water Filter with disposable glasses1 set of Medical First Aid Kit1 no. Discussion Table2 no. Discussion chair2 no.s. Storage / Wardrobe1 no. Notice Board1 no. White Board1 no. Work station with 1 monitor2 CCTV dome cameras with recording2 KVA UPS with 30 mins backup10 ltrs Room Cooler (water)2 no. Emergency Rechargeable Light for the booth with charger1. no. Handheld public Announcement System1 no. WiFi router1 Set Utensils (Plates, Glass, Cups, etc)Note: Clean closed space will be provided by Greater Noida with attached washroom
47Mobile Command and Control Vehicle. (MCCV) including all the below components (2.01 to 2.27) - Please don't mention separate rates for below components
48Mini Bus with Chassis: Wheel Base 3050 mm (approx.) from reputed OEM like TATA, Eicher, Ashok Leyland, Force motors etc.
49Split Air Conditioner (1Ton)
50Interiors design (as per the requirement)- for 1 Vehicle with external branding
51Mobile Command and Control Vehicle. (MCCV) including all the below components (2.01 to 2.27) - Please don't mention separate rates for below components
52Mini Bus with Chassis: Wheel Base 3050 mm (approx.) from reputed OEM like TATA, Eicher, Ashok Leyland, Force motors etc.
53Split Air Conditioner (1Ton)
54Interiors design (as per the requirement)- for 1 Vehicle with external branding
55Seating Arrangement Tables and chairs for two Operator and small couch with shock & vibration isolators for stability and safety
56Console with provision for monitor / display
57Inter- communication Service Console
5819\\" Rack with shock & vibration isolators for electronic
59Hydraulic Mast to mount PTZ Camera and Light (Min 4 Mtrs extended height from ground)
60Vehicle mount IP Outdoor 2 MP PTZ Camera, minimum 30X optical 10 X digital Zoom (IP 66 housing, 24VAC/POE+, 128 GB SD Card, Surge Protection Devices, all type of Cables mounting bracket with Bird spikes and all required accessories) with keyboard and joystick
61IP Fixed 4MP HD Bullet Camera with IP 66 rated housing for outdoor use, 128 GB SD Card, Surge Protection devices, Mounting Bracket, Bird Spikes, all type of cables with all required accessories
62Medium Storage (Wooden Cupboard)
63Industrial grade PC with 1 monitor support, intel i7, min. 16 GB RAM, 8 GB Graphic Card including minimum 3 Meter HDMI/ DVI/ DP cables and all accessories. With storage of 4 TB for camear recording.
6432 ”LED Full HD TV with fire stick for live TV footage
65Modular true online UPS with adequate capacity 3KVA with 30 minutes backup 30 meter raw power inlet cable.
66Min. 4.5 or above KVA Portable Inverter Generator set, Fuel type: Unleaded Petrol, salient design and Higher efficiency. Monitor equipped engine control panel display with Self-start feature.
67Video Management Software with licenses for min. 3 cameras
685G based 4 SIM Aggregator Device with SIM with recurring charges to be provided by GNIDA
69Network Hardware Management GigE Switch
70LED Flood Lights with 120-degree coverage (Mast Mounted)
71Top Bar Light with Siren
72Public Address System (PAS) with 2 vehicle mount outdoor Speakers
73Min. 5Kg ABC powder Fire Extinguishers
74Medical First-Aid Box
75Mini drinking water dispenser for 20 litre bottle
76Integration, Testing, Installation, Commissioning & Training
77Interoperable Communication System with Operator Display, Pedal PTT, Speakers, PTT Desk Mic & Record-Replay features. 2 Base Station Radios and 2 SIM cards for this will be provided by GNIDA
784G Aggregator/ Bonding Receiver with Unlimited bonding License
79Hardware - ICCC Components
80Workstation Desktop with 3 monitor, intel i7, min. 16 GB RAM, 8 GB Graphic Card including minimum 3 Meter HDMI/ DVI/ DP cables and all accessories
81Workstation Desktop with 1 monitor, intel i7, min. 16 GB RAM, 8 GB Graphic Card including minimum 3 Meter HDMI/ DVI/ DP cables
82LASER DLP based Rear Projection Video wall DLP Cubes of minimum 70” diagonal in a configuration. Resolution minimum full HD or better with controller, software and all accessories
83Joystick to control PTZ Cameras with all all accessories
8448 Port Gigabit Switch for ICCC (As per FRS and TRS, Volume II B)
85Minimum 2 ton Air conditioner for ICCC (Approx 5000 Sq. Ft. area)
86ICCC interior, Furniture & fixtures including 1 reception, 1 visitor room, 2 meeting rooms,1 viewing gallery construction, complete civil, interior work and furniture (tables, chairs, cubicle, storage racks, separator etc), Electrical Lightning and Fitting (Approx. 3000 Sq. Ft area) considering 30 staff for monitoring, 10 person meeting / war rooms, 6 person visiting room, 10 Person Viewing gallery and single person reception area with all other utilities and fixtures like Signages (Fire, Entry - Exit, Utilities etc)
87Hardware - Data Center Components
8848 Port Core Switch in High Availability (HA) Mode (As per FRS and TRS, Volume II B)
89Internet Router in High Availability (HA) Mode (As per FRS and TRS, Volume II B)
9048 Port Aggregation Switch in High Availability (HA) Mode (As per FRS and TRS, Volume II B)
91Networking Racks (42U) as per Solution Requirement (As per FRS and TRS, Volume II B)
92Networking Racks (12U) as per Solution Requirement (As per FRS and TRS, Volume II B)
93KVM Switch with Display/ Manageable 24 Port Switch
94Network and Cyber Security Audit (Every year) for 5 years
95Servers Required for all the Applications and software including but not limited to Database, Video Management System, Video Analytics, ISTMS System (ANPR, RLVD, SVD, Traffic Video Analytics), RLVD, ATCS, ISTMS, Speed Detection, e-Challan, Variable Message Signboard, Database Server, FRS server with GPU, EMS Server, Web Server, Virtualisation Server
9648 port Gigabit, Layer 3 Switch in HA Mode (As per FRS and TRS, Volume II B)
9724 Port L2 TOR Switch in HA Mode (As per FRS and TRS, Volume II B)
9848 Port L2 TOR Switch in HA Mode (As per FRS and TRS, Volume II B)
9924 port Gigabit, Layer 2 Switch (As per FRS and TRS, Volume II B)
10048 port Gigabit, Layer 2 Switch (As per FRS and TRS, Volume II B)
101Antivirus, Syslog & EMS Server (As per FRS and TRS, Volume II B)
102SAN RAID 5 for Virtualisation and database
103NAS for Video and log Storage, RAID 5 or better for 90 days of video and alarm data for 1300 Cameras at 25FPS, 1080p resolution
104Backup Appliance (D2D) along with Backup solution for 90 days and Logged / Flagged data for 180 days for 1300 Cameras at 25FPS, 1080p resolution
105Precision Air Conditioning for minimum 9 racks in Data Centre
106Miscellaneous Components (Common for ICCC and Data Center)
1072MP day and night Dome cameras with 128 GB SD Card for internal surveillance in ICCC and Data Center
108Network Video Recorder (NVR) with storage for 30 days, rack mount with all accessories for 10 dome cameras
109Biometric (Finger print based) + Smart Card based for time and attendance, Access control system minimum 200 users for ICCC and DC Area for all the doors (50 no.s Smart Cards, Controller, readers, locks with software and all accessories)
11055\\" Smart LED Display / TV, Full HD with WiFi and Bluetooth for 2 war room, reception, cafeteria, visitor gallery, 2 meeting rooms
111IP based Unified Communication Solution with 20. no.s of High-End IP Phones (desktop type) for ICCC helpdesk, receptionist, office administrators, operators and other staff. With intuitive 4 inch or bigger color-screen LCD notification display, modern design, with rich functionalities, integrated PoE, complete with all accessories
112PA System dialling console with licenses with integration for ICCC area
113Modular true online UPS with adequate capacity minimum 250 KVA with 30 minutes backup (1+1 Redundancy) for ICCC and Data Center equipment.
114Water proofing and Water Leak detection(WLD) system for Data Centre (400 Sq. Ft.), UPS Room (100 Sq. Ft.) and ICCC (3000 Sq. Ft.)
115Rodent Prevention and control for ICCC and Data Centre
116Heavy duty Color Laser Printer (All in one Printer , scanner, copier) compatible with WiFi, PC, Desktop and mobile devices with all accessories
117Software and applications
118ICCC Software
119ITMS Application Software
120Video Management Software
121Video Management Licenses with failover
122Facial Recognition Software with Base License and Channel License
123Mobile app. (Android and iOS platform) for citizens and Staff in the single app.
124VA (Video Analytics) licenses - Citizen Safety
125Video Analytics Software- Citizen Safety Use cases
126Crowd Detection and estimation
127Person Collapse detection
128Object abandoned detection
129Person Fighting detection
130Animal / Person detection
131Vandalism detection
132Loitering detection
133Fire Detection
134VA (Video Analytics) licenses - Traffic Management
135ANPR per camera licenses
136Red light violation software
137Red light violation License
138eChallan software (integrated with Vahan database of NIC)
139Accident and Incident Reporting system (AIRS) for 15 mobile client licences
140Video Summarization Software for video synopsis for 50 online and 50 off line licenses with 5 concurrent users
141No Parking violation detection License
142Triple riding violation detection License
143No Helmet violation detection License
144No Seat belt detection
145Wrong Direction Driving violation detection License
146Variable message signboard software
147Public announcement system Software
148ATCS Software including Simulation Model
149ATCS controller License
150VTDS / ATCC Software Central Application (As per BoQ)
151Integration with RTO DB and other interfaces
152Other Software
153Server Virtualization Software (As per BoQ)
154Server OS (As per BoQ)
155Application/ Appliance for Anti-Virus, Internet firewall, SIEM , WAF, DDoS etc as per cyber security section, mentioned in RFP.(VAPT should be done at the time of UAT)
156DB Software (As per BoQ)
157Enterprise Management System (EMS / NMS) with Helpdesk, SLA, Asset, Report Management
158Unified platform for database integration with customized business Intelligence (BI)
159GIS MAP base software with required licenses for Geo Spatial application
160Manpower - Operations and maintenance phase (60 Months) This is minimum Manpower, however MSI shall provide the adequate manpower for Project O&M support
161Project Director No. of man months and availability at site as per RFP requirement and project completion time lines.
162Project Director No. of man months and availability at site as per RFP requirement and project completion time lines.
163System and NW Administrator for Data Centre No. of man months and availability at site as per RFP requirement and project completion time lines.
164System and NW Administrator for Data Centre No. of man months and availability at site as per RFP requirement and project completion time lines.
165System and NW Administrator for Data Centre No. of man months and availability at site as per RFP requirement and project completion time lines.
166Field and data center Networking / Bandwidth
167Dedicated optical fiber networking for all field devices at all locations and datacentre with required bandwidth (including supply, digging, trenching, laying and maintenance for 5 years) as per above mentioned device quantities in all respects to make the solution complete including PoP locations for network distributionNote: Closed rooms for PoP will be provided by GNIDA however interiors, and IT equipment shall be provided by the bidder with required hardware, software, other passive components, power backup and HVAC), Measurement will be based on digging length. Pre laying of OFC, IA to ensure physical survey using GPR (Ground Penetration Radar) to ensure non-destructive detection of utilities to identify underlying features or buried services and detailed report to be submitted in both soft and hardcopy to the Authority)
168Labour Cess and GST will be paid extra as per govt. orders Please Enable Macros to View BoQ information

Other Detail

Information Source https://etender.up.nic.in
Download FileName File Description File Size
Download R19_Vol_III.pdf Tender Documents 0 KB
Download R19_Vol_I_GNIDA.pdf Tender Documents 0 KB
Download Tendernotice_1 (10).pdf Tender Documents 0 KB
Download 33ba1595-70cd-4372-a379-834aedae0d0f.html Tender Documents 0 KB
Download BOQ_2108436.xls Tender Documents 0 KB
Download R19_Vol_IIA_GNIDA.pdf Tender Documents 0 KB
Download R19_Vol_IIB.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.