Tendering Authority Public Works Department
Tender No 04/CE/PWD(DWS)/2025-26
Tender ID 2026_CEDWS_71778_1
Tender Brief Tender For Water Supply Scheme At Jamjuri Under Kakraban R.D. Block Of Gomati District, Tripura / Design,Supply And Construction Of 1.20 Mgd (Sixteen Hours Pumping) Capacity Water Treatment Plant Including Civil, Mechanical, Electrical Works, Supply
City Kakraban
State Tripura
Document Fees INR 8000 /-
EMD INR 911344.0 /-
Tender Value INR 4.55 Crore /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Water Supply Scheme At Jamjuri Under Kakraban R.D. Block Of Gomati District, Tripura / Design,Supply And Construction Of 1.20 Mgd (Sixteen Hours Pumping) Capacity Water Treatment Plant Including Civil, Mechanical, Electrical Works, Supply Of All Necessary Equipments, Testing And Successful Commissioning Of The Plant Etc. Complete In All Respect At Jamjuri Under Jal Jeevan Mission (Jjm) (Left Out Work).

Key Dates

Publish Date 24-03-2026
Last Date of Bid Submission 14-04-2026
Tender Opening Date 14-04-2026

Contact Information

Company Name Public Works Department
Contact Person Executive Engineer
Address O/o the Executive Engineer DWS Division Udaipur

BOQ Items

Name of Work:- Water Supply Scheme at Jamjuri under Kakraban R.D. Block of Gomati District, Tripura / Design,supply and construction of 1.20 MGD (Sixteen hours pumping) capacity Water Treatment Plant including Civil, Mechanical, Electrical works, supply of all necessary equipments, testing and successful commissioning of the plant etc. complete in all respect at Jamjuri under Jal Jeevan Mission (JJM) (Left out work).
Sl. No. Item Description
1Site Development including Approach Road of different Treatment plant units.
2Earthwork in excavation by mechanical means(Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including disposal of excavated earth, lead upto 50 m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soil
3Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidationg each deposited layer by ramming and watering, lead upto 50m and lift upto 1.5 m.-All kinds of soil
4Brick soling II) Flat Brick soling:-Providing and laying flat brick soling layer on prepared subgrade according to lines, grades and cross-section shown on the drawing, filling joints with Earth, free from clay with a Plasticity Index not exceeding 6, watering and rolling the same with three wheeled road roller 80-100 kN as per MoRD Technical Specification Clause 412. (Haulage of materials by tipper / truck with a lead upto another 12000 m including cost of loading, unloading and stacking .)
5I) Brick on edge soling:- Providing and laying brick on edge soling layer on prepared subgrade according to lines, grades and cross-section shown on the drawing, filling joints with sand, watering and rolling the same with three wheeled road roller 80-100 kN as per MoRD Technical Specification Clause 412 (Haulage of materials by tipper / truck with a lead upto another 12000 m including cost of loading, unloading and stacking )
6III) Brick edging laid in full brick widthProviding and laying brick edging on prepared subgrade according to lines, grades and cross-section shown on the drawing, filling joints with Earth, free from clay with a Plasticity Index not exceeding 6, watering and rolling the same with three wheeled road roller 80-100 kN as per MoRD Technical Specification Clause 412 (Haulage of materials by tipper / truck with a lead upto another 12000 m including cost of loading, unloading and stacking)
7Detailed Estimate for Construction of RCC Intake well for 1.2 MGD Water Treatment Plant
8Providing structural steel work riveted, bolted or welded in built up sections, trusses and framed work including cutting, hoisting and fixing in position and applying a priming coat of approved steel primer all complete as required.
9Detailed Estimate for Raw Water Pump House for 1.20 MGD capacity Water Treatment Plant
10Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 275mm long wire springs grade No.2 and M.S. top cover of required thickness for rolling shutters & with handles, hold fast including embedding in cement concrete of required grade required for fixing in position, all necessary fittings, including applying of approved steel primer etc. complete as required:.i) 80 x 1.25mm M.S. laths with 1.25 mm thick top cover
11Providing and laying cement concrete 1:2:4 ( 1 cement : 2 fine sand : 4 graded stone aggregate 20 mm nominal size ) flooring finished with a floating coat of neat cement including cement slurry, rounding of edges and strips and cost of glass strips etc. complete.i) 40 mm thick with 20 mm stone aggregate
12Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 grams/ litre, of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :New work ( two or more coats) over and including water thinnable priming coat with cement primer.
13Applying one coat of water thinnable cement primer of approved brand and manufacturer on wall surface complete.Water thinnable cement primer
14Finishing walls with acrylic smooth exterior paint of required shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer] : New work ( two or more coats applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
15Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]: Two or more coats on new work over an under coat of suitable shade with ordinary paint (primer) of approved brand and manufacture
16Providing and laying cement concrete 1:2:4 ( 1 cement : 2 fine sand : 4 graded stone aggregate 20 mm nominal size ) flooring finished with a floating coat of neat cement including cement slurry, rounding of edges and strips and cost of glass strips etc. complete.i) 40 mm thick with 20 mm stone aggregate
17Grading roof for water proofing treatment complete as required as per direction of the Engineer-in-charge with :Cement concrete 1:2:4 (1 cement : 2 fine sand : 4 graded stone aggregate 20 mm nominal size)
18Providing structural steel work riveted, bolted or welded in built up sections, trusses and framed work including cutting, hoisting and fixing in position and applying a priming coat of approved steel primer all complete as required.
19Fabrication, Supply and erection for (30.0 + 25.0) mtr Steel Foot Bridges along with RCC Abutment & Pier.
20Providing structural steel work riveted, bolted or welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete as required.
21Providing and fixing hand rail using structural steel etc. of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer complete as required. G.I pipes
22Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an evenshade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]: Two or more coats on new work over an under coat of suitable shade with ordinary paint (primer) of approvedbrand and manufacture
23Steel work welded in built up section/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. complete as required:- i) In grating, frames, guard bar, railing, brackets, gates and similar works, all complete
24Construction of RCC Abutment for (30.0+25.0) mtr steel foot bridge along with pier
25Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporay casing of appropriate length for setting out and removal of same and the length of pile to be embedded in the pile cap etc. by percussion drilling using Direct Mud Circulation (DMC) or Bailer and Chisel Technique by Tripod and Mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads.( Length of pile for payment shall be measured upto the bottom of pile cap ). Note:Truck Mounted rotary/ TMR/Tubewell Boring Machine shall not be used. a. 450 mm Dia
26Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level:i) 1 : 3 : 6 ( 1 cement : 3 fine sand : 6 graded well burnt brick aggregate of 40 mm nominal size)
27Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level.i) 1 : 1 : 2 ( 1 cement : 1 fine sand : 2 graded stone aggregate of 20 mm nominal size)
28Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses,plinth and skirting courses, fillets, columns, pillars,piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement-1:1:2 ( 1 Cement: 1 fine sand : 2 graded stone aggregate 20 mm nominal size)
29Reinforcement for RCC works including straightening, cutting, bending, placing in position and binding all complete upto plinth leveli) Thermo-mechanically treated bars of grade FE-500D or more.
30Reinforcement for RCC works including straightening, cutting, bending, placing in position and binding all complete above plinth leveli) Thermo-mechanically treated bars of grade FE-500D or more.
31Centering shuttering including struttings, propping etc. and removal of form work for :i) Foundations, footings, bases for columns etc. for mass concrete with steel formwork
32ii) Columns, Pillars, Piers, Abutments, Posts and Struts with M.S. shutters
33Extra for additional height in centring, shuttering where ever required with adequate bracing, propping etc including cost of de-shuttering and decentring at all levels, over a hright of 3.5m, for every additional height of 1 metre or part thereof: Suspended floors, roofs, roof, landing, beams and balconies (Plan area to be measured). Columns,Pillars,Piers, Abutments, Posts and Struts with M.S. shutters3.5m to 4.5m
344.5m to 5.5m
356 mm cement plaster of mix:i) Cement mortar 1:4 (1 cement:4 fine sand)
36Neat Cement punning
37Cost of Vertical Turbine pump with motor for Raw Water
38Installation and commissioning of VT pump with suitable motor operating at synchronous speed of 1470 RPM, in/c. 10.50 mtr of 200 mm double flanged column pipe and shaft assembly with basket stainer suitable for lifting of raw water from intake well complete in all respect as per direction of Engineer-in-charge.
39Charges for fixing C.I. sluice valves with cap complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge 200 mm Dia A) P.N-1.6
40Charges for fixing C.I. non-return valve of approved quality as per CPWD specification and direction of the Engineer-in-charge. i) 200 mm dia
41Charges for fitting & fixing of steel sheet enclosed switch fuse unit (suitable for DIN fuses), triple pole with Neutral Link (TPN), current range 200 Amps, 415/500 Volt, L & T / Havell's/ HPL make etc. complete as per specification and direction of the Engineer-in-charge. 200 amps
42Charges for fitting, fixing of Fully Automatic Star Delta type Motor starter ( 3 ph. 50 Hz, 415V, 125 HP/ 90 kw Relay range within66-110 + 10% ) in Steel Sheet Enclosures with Contractors and Timer etc. complete suitable for submersible Pump L & T, BCH, ABB make as per specification and direction of the Engineer-in-charge. I) 75 HP/ 55 kw Relay range within 45-75 + 10%
43Charges for fitting fixing of moving iron type, Range 0-500 V, 96 mm x 96 mm size AC Volt meter ( L & T / AE make) with selector switch as a electrical instrument of the pannel board as per specification and direction of the Engineer-in-charge.
44Charges for fitting fixing of moving iron type, Range 0-100/0-200 amps, 96 mm x 96 mm size AC Amps meter direct reading type ( L & T / AE make) with selector switch and CT coil as a electrical instrument of the pannel board as per specification and direction of the Engineer-in-charge. i) 0-200 amps
45Charges for fitting fixing of Moulded Case Circuit Breaker (MCCB) of different Thermal release range , 415 + V, 50Hz (L & T, BCH, ABB make) as per specification and direction of the Engineer-in-charge. i) 80-100 Amps
46Charges for fitting fixing with PVC insulated single core multistrand Copper cable conforming to IS : 694 for inter connection with all electrical equipments of the pannel board as per specification and direction of the Engineer-in-charge. i) 50 Sqmm
47Charges for fitting fixing of 6 feet x 4 feet x 1 inch (thickness) Gamair wood / plywood pannel board for fitting fixing of electrical items, in/c 2 nos MS angle post ( size 2 inch x 2 inch x 9 feet ), nuts & bolts etc. for irrection of the same by 1:1.5:3 cement concrete casting ( 1 feet x 1 feet x 2 feet) below the ground level and painting two or more coats & plastic paint as per specification and direction of the Engineer-in-charge.
48Charges for fitting fixing heavy duty box type (Resin filled) power factor correction capacitor L & T make etc. complete as per specification and direction of the Engineer-in-charge. 20-50 kVAr
49Charges for fitting fixing 3 phase indicating lamp fiited with panel board with three different colour lamps with batten holder complete as per specification and direction of the Engineer-in-charge.
50Charges for earthing with perforated 40 mm dia G.I. pipe (Medium class) ( 12 mm dia perforation), laying of 4 mm dia GI wire from earth electrode to panel, including excavating hole of 600 mm dia and refilling with Salt and Charcoal / coke in alternate layers of 300 mm , as per standard specification and direction of the Engineer-in-charge. i) for 3-phase connection with 4.00 mtr. Long G.I. Pipe
513 ton capacity Chain pully with chain & Mechanical arrangement
52Charges for laying Double Flanged ( screwed / welded ) centrifugually ( Spun ) cast iron, class B ( IS : 1536 ) as per CPWD specification and direction of the Engineer - in - charge. i) 300 mm dia C.I. Double Flanged Pipe
53ii) 200 mm dia C.I. Double Flanged Pipe
54Providing and laying flanged C.I. standard specials such as tees, bends, collars, tapers, caps etc. suitable for flanged jointing as per IS : 1538 as per CPWD specification and direction of the Engineer - in - charge i) Upto 300 mm dia.
55Providing & laying of raw water rising main line from Intake Well to water treatment plant
56Excavating trenches of required width for pipes, cable etc. in/c excavating for sockets & dressing of sides, where required, ramming of bottoms, depth up to 1500mm in/c getting out the excavated soil and backfilling of soil as required after laying of pipe line, in layers not exceeding 200mm in depth in/c consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil with all required leads as per chapter-2 of CPWD specification and direction of the Engineer-in-charge. B) For GI/CI/DI pipes in new work. a) In all kinds of soil. i) For pipes exceeding 90 mm dia. but not exceeding 300mm dia.
57ii)For pipes exceeding 300 mm dia. but not exceeding 600 mm dia.
58Providing and laying S&S centrifugally cast (SPUN) ductile iron class K-9 pipes conforming to IS: 8329 as per CPWD specification and direction of the Engineer-in Charge.i)300 mm dia Ductile Iron Class K-9
59ii) 350 mm dia Ductile Iron Class K-9 pipes
60Providing and laying DI Special of class K-12 for suitable for push-on jointing as per IS-9523 as per CPWD Specification and direction of Engineer-in Chargei)Upto 300 mm dia
61ii) Above 300mm dia.
62Charges for fixing C.I. non-return valve of approved quality as per CPWD specification and direction of the Engineer-in-charge. i) 300 mm nominal bore
63ii) 350 mm nominal bore
64Charges for fixing C.I. double action air valve of approved quality with bolts, nuts, rubber insertions etc. complete as per CPWD specification and direction of the Engineer-in charge. (The tail pieces, tapers etc if required will be paid separately), (air valve to be issued by the department).i) 300 mm dia
65ii) 350 mm dia
66Providing and Supplying of pig lead conforming to IS: 27 at site of work as per CPWD specification and direction of the Engineer- in -charge
67RCC Supporting blocks (1:1½:3, 1 cement:1½ fine sand :3 graded stone aggregate 20 mm nominal size having size of block of 500 mm X 500 mm X 750 mm depth, atleast 450 mm should be below GL and 75 mm thick sand filling and 75 mm thick 1:3:6 PCC)
68Detailed Estimate for PST cum Cascade Aerator of 1.2 MGD Capacity SWTP
696 mm cement plaster of mix:i) cement mortar 1:4 ( 1 cement : 4 fine sand )
70Neat cement punning.
71Applying one coat of cement primer of approved brand and manufacture on wall surface complete.i)Water thinnable cement primer
72Finishing walls with acrylic smooth exterior paint of required shade of approved brand and manufacture (payment shall be made after submission of Test Certificate issued by the Manufacturer) New work (two or more coats applied @1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)New work (two or more coats applied @1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
73Detailed Estimate for Flash Mixer with Raw water Channel of 1.2 MGD Capacity SWTP
74Earthwork in excavation by mechanical means (Hydraulic Excavator)/manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms,lift up to 1.5m, including getting out the excavated and disposal of surplus excavated soil as directed, within a lead of 50m. i) All kinds of soil.
75Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidationg each deposited layer by ramming and watering, lead upto 50m and lift upto 1.5 m.All kinds of soil
76Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete.
77Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level:i) 1 : 3 : 6 ( 1 cement : 3 fine sand : 6 graded well burnt brick aggregate of 40 mm nominal size)
78Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring and shuttering- All work upto plinth level:i) 1 : 1 : 2 ( 1 cement : 1 fine sand : 2 graded stone aggregate of 20 mm nominal size)
79Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, coloumns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement.1 : 1 : 2 ( 1 cement : 1 fine sand : 2 graded stone aggregate of 20 mm nominal size)
80Reinforced cement concrete work in beams, suspended floors, roofs having slope 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement-1 : 1 : 2 ( 1 cement : 1 fine sand : 2 graded stone aggregate of 20 mm nominal size)
81Providing, hoisting and fixing above plinth level up to floor five level pre-cast reinforced cement concrete in string courses, bands, copings, bed plates, anchor blocks, plain window sills & the like including the cost of required centeing ,shuttering,but excluding the cost of reinforcement,with 1:1.5:3 ( 1 cement : 1.5 fine sand: 3 graded stone aggregate 20 mm nominal size).
82Reinforcement for RCC works including straightening,cutting,bending placing in position and binding all complete above plinth level
83Reinforcement for RCC works including straightening,cutting,bending placing in position and binding all complete upto plinth level i) Thermo-mechanically treated bars of grade Fe-500 D or more
84Steel work welded in built up section/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. complete as required :-I) In grating, frames, guard bar, railing, brackets, gates and similar works, all complete.
85Providing and fixing hand rail using structural steel etc.of approved size by welding etc. to steel ladder railing,balcony railing and staircase railing etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer complete as required:-GI pipes
866 mm cement plaster of mix Cement mortar 1:4(1cement :4 fine sand )
87Neat cement punning.
88Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface complete. Water thinnable cement primer
89Finishing walls with water proofing cement paint of required shade of approved brand and manufacture[Payment shall be made after submission of Test Certificate issued by the Manufacturer] :New work ( two or more coats applied @ 3.84 kg/10 sqm)
90Centering shuttering including strutting, propping etc. and removal of form work fori)Foundations, footings, bases for column s etc. for mass concrete with steel formwork.
91iii)Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply.
92iv)Suspended floors ,roofs, landings, balconies and access platform with MS plates & props
93) Columns, Pillars,Piers, Abutments, Posts and Struts with M.S. shutters
94vi)Spiral staircases (including landing) cast in situ with ply
95Extra for additional height in centring, shuttering where ever required with adequate bracing, propping etc including cost of de-shuttering and decentring at all levels, over a hright of 3.5m, for every additional height of 1 metre or part thereof: Suspended floors, roofs, roof, landing, beams and balconies (Plan area to be measured).
96Detailed Estimate for Clariflocculator of 1.2 MGD Capacity Surface Water Treatment plant
97Steel work in welded built up sections / framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc.complete as required i) In grating, frames, guard bar, railing ,brackets, gates & similar works all complete..
98Providing and fixing hand rail using structural steel etc. of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer complete as required. i. GI pipes
996 mm cement plaster of mix Cement mortar 1:4 ( 1 cement : 4 fine sand )
100Neat cement punning.
101Applying one coat of water thinnable cement primer of approved brand and manufacturer on wall surface complete. Water thinnable cement primer
102Finishing walls with water proofing cement paint of required shade of approved brand and manufacture[Payment shall be made after submission of TestCertificate issued by the Manufacturer] : New work ( two or more coats applied @ 3.84 kg/10 sqm)
103Detailed Estimate for Filter cum chemical house of 1.2 MGD Capacity Surface Water Treatment plant
104Earthwork in excavation by mechanical means (Hydraulic Excavator)/manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms,lift up to 1.5m, including getting out the excavated and disposal of surplus excavated soil as directed, within a lead of 50m. i) All kinds of soil
105Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidationg each deposited layer by ramming and watering, lead upto 50m and lift upto 1.5 m.All kinds of soil
106Supplying and filling in plinth, under floor, foundations etc.with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitablemethod complete.
107Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering -All work upto plinth level:i) 1 : 3 : 6 ( 1 cement : 3 fine sand : 6 graded well burnt brick aggregate of 40 mm nominal size)
108Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars,piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement-1:1:2 ( 1 Cement: 1 fine sand : 2 graded stone aggregate 20 mm nominal size)
109Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies,shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement-1:1:2 ( 1 Cement: 1 fine sand : 2 graded stone aggregate 20 mm nominal size)
110Reinforcement for R.C.C. work including straightening,cutting, bending, placing in position and binding all complete below plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more
111Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. complete as required:-i) In grating, frames, guard bar, railing ,brackets, gates & similar works, all complete.
112Providing and fixing hand rail using structural steel etc.of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer complete as required:-:i) G.I. pipes
113Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and joined together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 275mm long wire springs grade No.2 and M.S. top cover of required thickness for rolling shutters and with handles, hold fast including embedding in cement concrete of required grade required for fixing in position, all necessary fitting, including applying of approved steel primer etc. complete as required.I) 80 x 1.25 mm MS laths with 1.25 mm thick top cover
114Providing and fixing aluminium work for doors,windows, ventilators and partitions with extruded builtup standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up of gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling,C.P. brass / stainless steel screws, all complete as per architectural drawing and the direction of Engineer in charge.(Glazing and paneling and dash fasteners to be paid for separately) :-For fixed portion of approved quality:-Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15).
115For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing fittings wherever required including the cost of EPDM rubber/ neoprene gasket required ( Fittings shall be paid for separately ):a. Anodised aluminium (anodised transparent or dyed to required shade according to IS : 1868 , minimum anodic coating of grade AC 15 )
116Providing and fixing glazing of approved quality in aluminium doors, windows, ventilator, shutters and partition etc. with EPDM rubber / neoprene gasket etc.complete as per architectural drawing and the direction of Engineer-in-charge (Cost of snap beading shall be paidin basic item) :-a. With glass/float panes of 4.0 m thickness ( weight not less than 10.0 kg / sqm )
117Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc.complete as per direction of Engineer-in-charge: i(Anodised aluminium of grade AC 15 )
118Providing and fixing 100 mm brass locks ( best make of approved quality ) with 6 levers without pair of handles for aluminium doors including necessary cutting and making good etc. complete as per direction of Engineer-in-charge:
119Providing and fixing aluminium tower bolts anodised ISI marked (anodised anodic coating not less than grade AC 10 as per IS 1868) transparent or dyed to required colour or shade with necessary screws etc. complete .i) 300x10 mm
120Providing and fixing aluminium hanging floor door stopper anodised ISI marked (anodised coating not less than grade AC 10 as per IS 1868) transparent or dyed to required colour or shade with necessary screws etc. complete .i) Twine rubber stopper
12120 mm cement plaster of mixCement mortar 1:6 ( 1 cement : 6 fine sand )
12215 mm cement plaster on the rough side of single or half brick wall of mix:Cement mortar 1:6 ( 1 cement : 6 fine sand
1236 mm cement plaster of mix :Cement mortar 1:4 ( 1 cement : 4 fine sand )
124Neat cement punning.
125Applying one coat of water thinnable cement primer of approved brand and manufacturer on wall surfacecomplete.Water thinnable cement primer
126Finishing walls with water proofing cement paint of required shade of approved brand and manufacture[Payment shall be made after submission of Test Certificate issued by the Manufacturer] :New work ( two or more coats applied @ 3.84 kg/10 sqm)
127Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 grams/ litre, of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :
128New work ( two or more coats) over and including water thinnable priming coat with cement primer..Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:Two or more coats on new work over an under coat of suitable shade with ordinary paint (primer) of approved brand and manufacture
129Providing and laying cement concrete 1:2:4 (1 cement: 2 fine sand : 4 graded well burnt brick aggregate) flooring finished with a floating coat of neat cement including cement slurry, rounding of edges and strips and cost of glass strips etc. complete.i) 40 mm thick
130Providing and fixing 1st quality ceramic glazed wall tiles(minimum 200 x 300) conforming to IS : 15622 - 2017 (thickness to be specified by the manufacturer) of approved make in all colours, shades of any size as approved by Engineer-in-charge in skirting, risers of steps and dados, laid over 12 mm thick bed of cement mortar 1 : 3 (1 cement : 3 fine sand) jointed with ordinary cement slurry including pointing with white cement mixed with pigment of matching shade complete.
131Providing and laying 1st class quality ceramic floor tiles in different sizes (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 -2017 of approved make in colours such as White, Ivory,Grey, Fume Red Brown, laid over 20 mm thick cement mortar 1:4 (1 cement : 4 fine sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc. all complete as per direction of the Engineer in-charge. Mat Finish Tiles/ Anti-skid Tiles/ Glossy Tiles300 mm x 300 mm in all shades and designs
132Providing and laying dry flat brick flooring in required pattern complete.
133Providing and laying cement plaster skirting upto 300mm height with cement mortar 1 : 3 ( 1 cement : 3 fine sand ) finished with a floating coat of neat cement including rounding of junctions etc. complete.18 mm thick
134Grading roof for water proofing treatment complete as required as per direction of the Engineer-in-charge with :Cement concrete 1:2:4 (1 cement : 2 fine sand : 4 graded stone aggregate 20 mm nominal size)
135Providing and laying APP(Atatic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with nn-woven plyster matt consisting of a coat of bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25C , 0.87-0.89 kg/litre and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing teh surface complete. The vital physical and chemical parameters of the membrane shall be as under: Joint strength in longitudinal and transverse direction at 23C as 650/450N/5cm. tear strength in longitudinal and transverse direction as 300/250 N.Softening point of menbrane not less than 150 C.Cold flexibility shall be upto -2C when tested in accordance with ASTM, D-5147 as per direction of the Engineer-in-Charge. The laying of menbrane shall be got done through the authorised applicator of the manufacturer of membrane as required as per direction of the Engineer-in-Charge:3mm thick
136Centering shuttering including strutting, propping etc. and removal of form work for :i) Columns, Pillars,Piers, Abutments, Posts and Struts with M.S. shutters
137iii)Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply.
138v)Walls (any thickness) including attached pilasters, buttresses, plinth and string coures etc. using shutering ply
139Providing and fixing factory made UPVC door frame made of UPVC extruded, section having an overall dimension, as below (tolerance +/- 1mm) with wall thickness 2.0mm+/- 02mm. corners of the door frame to be jointed with galvanized brackets and stainless screws, joint mitred and plastic wilded. The hinge side vertical of the frames reinforced by galvanized MS tube of size 19 × 19 mm and 1 mm +/-0.1 mm wall thickness and 3 nos stainless steel hinges fixed to the frame complete as per manufacturers specification and direction of Engineer-In-Charge.Extruded section Profile size 42x50 mm.
140Providing and fixing to existing door frames. 24 mm thick factory made PVC door shutters made of styles and rails of a UPVC hollow section of size 59x24 mm and wall thickness 2 mm ± 0.2 mm with inbuilt edging on both sides. The styles and rails mitred and joined at the corners by means of M.S. galvanised/plastic brackets of size 75×220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserying galvanised MS tube of size 20×20 mm and 1 mm ± 0.1 mm wall thickness. The lock rail made up of \\"H\\" Section, a UPVC hollow section of size 100×24 mm and 2 mm ±0.2 mm wall thickness fixed to the shutter styles by means of plastic /galvanised MS \\"U\\" cleats. The shutter frame filled with a UPVC multi-chambered single panel of size not less than 620 mm, having overall thickness of 20 mm and 1 mm ± 0.1 mm wall thickness. The panels filled vertically and tie bar at two places by inserting horizontaly 6 mm galvanised MS rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-In-Charge. (for W.C. and Bathroom door shutter).
141Providing and placing rapid gravity filter sand having effective size of 0.50 mm to 1.00 mm & uniformity co-efficient of not more than 1.70 and or less than 1.30 obtained from Barakar river West Bengal as per specification and the direction of the Engineer - in - charge.
142Providing and placing filter gravel having effective size of 3.00 mm to 25 mm & uniformity co-efficient of not more than 1.70 and or less than 1.30 obtained from Barakar river, West Bengal as per specification and the direction of the Engineer -in-charge.
143Providing and fixing water closet squatting pan ( Indian type W.C. pan ) with 100 mm sand cast iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device ( handle lever ) conforming to IS: 7231, with all fittings and fixtures complete including cutting and making good the wall and floors wherever required, as per CPWD specification and direction of the Engineer - in - charge.White Vitreous china Orissa pattern W.C. pan of size 580 x 440 mm with integral type foot rests.
144Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430 x 260 x 350 mm and 340 x 410 x 265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required, as per CPWD specification and direction of the Engineer - in - charge.One urinal basin with 5 litre white P.V.C. automatic flushing cistern.
145Providing and fixing white vitreous china flat back half stall urinal of size 580 x 380 x 350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps ( all in C.P. brass ) with waste fitting as per IS: 2556, C.I. trap with outlet gratingand other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever required, as per CPWD specification and direction of the Engineer - in - charge.Single half stall urinal with 5 litre PVC automatic flushing cistern.
146Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required, as per CPWD specification and direction of the Engineer - in - charge.White Vitreous China Wash basin size 630 x 450 mm with a single of 15 mm C.P.brass pillar tap.
147Providing and fixing soil, waste and vent pipes as per CPWD specification and direction of the Engineer - in - charge.100 mm dia.Sand cast iron S&S pipe as per IS: 1729
148Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete as per CPWD specification and direction of the Engineer-in-charge.
149Providing and fixing 600x120x5mm glass shelf with edges round of supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
150Providing and fixing plain bend of required degree as per CPWD specification and direction of the Engineer - in -charge.100 mm dia.Sand cast iron S & S as per IS - 1729
151Providing and fixing G.I. pipes medim class as per IS : 1239 with latest amendment complete with G.I. fittings including trenching and refilling, cutting and making good the walls etc.complete as per CPWD specification and direction of theEngineer - in - charge. External work. 32 mm dia. nominal bore
15250 mm dia. nominal bore
153Providing and fixing G.I. Bend /elbow in the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.32 mm dia.
15450 mm dia.
155Providing and fixing G.I. socket as per CPWD specification and direction of the Engineer - in - charge.32 mm dia.
15650 mm dia.
157Providing and fitting fixing PVC / plastic bib cock conforming to IS : 9763 in hydrant points at different location as per specification & direction of the Engineer-in-charge.20 mm dia PVC /plastic bib cock
158Detailed Estimate for 1.5 Lakh Gallon Clear Water Resevior of 1.2 MGD capacity Surface Water Treatment Plant
1596 mm cement plaster of mix: Cement mortar 1:4 ( 1 cement : 4 fine sand )
160Neat cement punning.
161Detailed Estimate for CWR pump House of 1.2 MGD capacity Surface Water Treatment Plant
162Providing and laying cement concrete 1:2:4 ( 1 cement : 2 fine sand : 4 graded stone aggregate 20 mm nominal size ) flooring finished with a floating coat of neat cement including cement slurry, rounding of edges and strips and cost of glass strips etc. complete. i) 40 mm thick with 20 mm stone aggregate
1636 mm cement plaster of mix: Cement mortar 1:4 ( 1 cement : 4 fine sand )
16415 mm cement plaster on the rough side of single or half brick wall of mix: Cement mortar 1:6 ( 1 cement : 6 fine sand)
165Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade.[Payment shall be made after submission of Test Certificate issued by the manufacture]
166Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface complete. Water thinnable cement primer
167Finishing walls with water proofing cement paint of required shade of approved brand and manufacture[Payment shall be made after submission of Test Certificate issued by the Manufacturer] : New work ( two or more coats applied @ 3.84 kg/10 sqm)
168Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:Two or more coats on new work over an under coat of suitable shade with ordinary paint (primer) of approved brand and manufacture.
169Detailed Estimate for Chlorinator room of 1.2 MGD capacity SWTP
170Providing and laying cement concrete 1:2:4 ( 1 cement : 2 fine sand : 4 graded stone aggregate ) flooring finished with a floating coat of neat cement including cement slurry, rounding of edges and strips and cost of glass strips etc. complete. i) 40 mm thick with 20 mm stone aggregate
1716 mm cement plaster of mix : i) cement mortar 1:4 ( 1 cement : 4 fine sand )
17220 mm cement plaster of mix i) cement mortar 1:6 ( 1 cement : 6 fine sand )
173Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade.[Payment shall bemade after submission of Test Certificate issued by the manufacture]
174Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface complete. Water thinnable cement primer
175Finishing walls with water proofing cement paint of required shade of approved brand and manufacture[Payment shall be made after submission of Test Certificate issued by the Manufacturer] : New work ( two or more coats applied @ 3.84 kg/10 sqm)
176Detailed Estimate for Surface Drain & Plinth Protection of 1.2 MGD Capacity Surface Water Treatment plant
177Earthwork in excavation by mechanical means (Hydraulic Excavator)/manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms,lift up to 1.5m, including getting out the excavated and disposal of surplus excavated soil as directed, within a lead of 50m. i) All kinds of soil
178Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidationg each deposited layer by ramming and watering, lead upto 50m and lift upto 1.5 m.All kinds of soil
179Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete.
180Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level:i) 1 : 4 : 8 ( 1 cement :4 fine sand : 8 graded well burnt brick aggregate of 40 mm nominal size)
18112 mm cement plaster of mix
182Neat cement punning.
183Making plinth protection 50 mm thick of cement concrete 1:3:6(1 cement:3 fine sand: 6 graded well burnt brick aggregate 20 mm nominal size) over 75 mm bed of dry brick ballast 40 mm nominal size well rammed & consolidated & grouted with fine sand including finishing the top smooth.
184Detailed Estimate for Providing all internal sludge lines, complete with pits etc and connection to the central sludge well.
185Providing & laying non-pressure NP2 class (light duty) R.C.C pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. complete. i) 300 mm dia R.C.C Pipe
186Excavating trenches of required width for pipes, cables etc. including exacavation for sockets, dressing of sides where required, ramming of bottoms, depth upto 1500 mm (slope-1) including getting out the excavated soil and backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil with all required leads as per Chapter - 2 of CPWD specification and direction of the Engineer - in - charge. i) For G.I/C.I/D.I pipes in new work a. In all kinds of soil a) For pipes exceeding 90 mm dia but not exceeding 300 mm dia
187Providing and laying Double flanged (screwed/ welded) centrifugally (Spun) cast iron , class B (IS:1536) as per CPWD specification and direction of the Engineer-in -Charge.150 mm dia Ductile Iron Doubled flanged
188Earthwork in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan ) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil, and disposal of surplus excavated soil as directed, within a lead of 50 m. i) All kinds of soil
189Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidationg each deposited layer by ramming and watering, lead upto 50m and lift upto 1.5 m.
190Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level:i) 1 : 3 : 6 ( 1 cement : 3 fine sand : 6 graded well burnt brick aggregate of 40 mm nominal size)
191Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level.i) 1 : 1 : 2 ( 1 cement : 1 fine sand : 2 graded stone aggregate of 20 mm nominal size)
192Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete upto plinth leveli) Thermo-mechanically treated bars of Grade 500-D or above
1936 mm cement plaster of mixi) cement mortar 1:4 ( 1 cement : 4 fine sand )
194Neat cement punning.
195Centering shuttering including struttings, propping etc. and removal of form work for :i)Foundations, footings, bases for columns etc.for mass concrete with timber plank
196Cost of Vertical Turbine pump with motor for Clear Water
197Charges for fixing C.I. non-return valve of approved quality as per CPWD specification and direction of the Engineer-in-charge. i) 200 mm dia nominal bore
198Charges for fixing C.I. sluice valves with cap complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge i)200 mm Dia A) P.N-1.6
199Charges for fitting & fixing of steel sheet enclosed switch fuse unit (suitable for DIN fuses), triple pole with Neutral Link (TPN), current range 200 Amps, 415/500 Volt, L & T / Havell's/ HPL make etc. complete as per specification and direction of the Engineer-in-charge. 200 amps
200Charges for fitting, fixing of Fully Automatic Star Delta type Motor starter ( 3 ph. 50 Hz, 415V, 125 HP/ 90 kw Relay range within66-110 + 10% ) in Steel Sheet Enclosures with Contractors and Timer etc. complete suitable for submersible Pump L & T, BCH, ABB make as per specification and direction of the Engineer-in-charge. I) 75 HP/ 55 kw Relay range within 45-75 + 10%
201Charges for fitting fixing of moving iron type, Range 0-500 V, 96 mm x 96 mm size AC Volt meter ( L & T / AE make) with selector switch as a electrical instrument of the pannel board as per specification and direction of the Engineer-in-charge.
202Charges for fitting fixing of moving iron type, Range 0-100/0-200 amps, 96 mm x 96 mm size AC Amps meter direct reading type ( L & T / AE make) with selector switch and CT coil as a electrical instrument of the pannel board as per specification and direction of the Engineer-in-charge. i) 0-200 amps
203Charges for fitting fixing of Moulded Case Circuit Breaker (MCCB) of different Thermal release range , 415 + V, 50Hz (L & T, BCH, ABB make) as per specification and direction of the Engineer-in-charge. i) 80-100 Amps
204Charges for fitting fixing with PVC insulated single core multistrand Copper cable conforming to IS : 694 for inter connection with all electrical equipments of the pannel board as per specification and direction of the Engineer-in-charge. i) 50 Sqmm
205Charges for fitting fixing of 6 feet x 4 feet x 1 inch (thickness) Gamair wood / plywood pannel board for fitting fixing of electrical items, in/c 2 nos MS angle post ( size 2 inch x 2 inch x 9 feet ), nuts & bolts etc. for irrection of the same by 1:1.5:3 cement concrete casting ( 1 feet x 1 feet x 2 feet) below the ground level and painting two or more coats & plastic paint as per specification and direction of the Engineer-in-charge.
206Charges for fitting fixing heavy duty box type (Resin filled) power factor correction capacitor L & T make etc. complete as per specification and direction of the Engineer-in-charge. 20-50 kVAr
207Charges for fitting fixing 3 phase indicating lamp fiited with panel board with three different colour lamps with batten holder complete as per specification and direction of the Engineer-in-charge.
208Charges for earthing with perforated 40 mm dia G.I. pipe (Medium class) ( 12 mm dia perforation), laying of 4 mm dia GI wire from earth electrode to panel, including excavating hole of 600 mm dia and refilling with Salt and Charcoal / coke in alternate layers of 300 mm , as per standard specification and direction of the Engineer-in-charge. i) for 3-phase connection with 4.00 mtr. Long G.I. Pipe
2093 ton capacity Chain pully with chain & Mechanical arrangement
210Labour Charge for fitting fixing of 1(one) set pump motor & all other related arrangement etc complete.{ANNEXURE-AIX(i)}
211Charges for laying Double Flanged ( screwed / welded ) centrifugually ( Spun ) cast iron, class B ( IS : 1536 ) as per CPWD specification and direction of the Engineer - in - charge. i) 300 mm dia C.I. Double Flanged Pipe
212ii) 200 mm dia C.I. Double Flanged Pipe
213Providing and laying flanged C.I. standard specials such as tees, bends, collars, tapers, caps etc. suitable for flanged jointing as per IS : 1538 as per chapter 20 of CPWD specification and direction of the Engineer - in - charge. i) Upto 300 mm dia.
214Providing and installation of mechanical equipment for flash mixer such as mild steel mixer (stirrer type) mounted on MS shaft driven by suitable motor coupled with necessary gear arrangement, by pass valve etc complete.
215Providing and installation of mechanical equipment for rapid gravity Filters such as under drainage system complete with manifolds, AC laterals, CI flanged pipes and specials, penstock gates for waste water, inlet and outlet valves, sluice valves, rate of flow controllers, air wash lines including connection to the air blowers & back wash water lines etc. complete.
216Installation of mechanical equipment for Chemical house such as flow recorder of integrating and recording type, agitators for alum solution tanks, spriklers, alum feeding arrangement complete with diaphram valves, lime bin ,lime mill, reduction gears including motors, internal water supply line to different units of the plant etc. complete with electrical pannel boards, and installation of laboratory equipment etc complete.
217Providing and installation of 2 (two) Nos, Chlorinators, one of bleaching powder solution fed type and another electro- chlorinator for on site generation of sodium hypochlorite solution capable of discharging 350 gm per hour active chlorine including arrangement for dosing of solution to filter effluent etc complete.
218Providing & installation of turbo air blower
219Supplying of tarbo air blower (1 nos) of 385 cfm capacity & with required capacity (5 HP) horizontal motor along with allied electrical equipments etc. complete
220Providing and fitting fixing of 6 feet x 4 feet x1 inch (thickness) Gamair wood / plywood pannel board for fitting fixing of electrical items, in/c 2 nos MS angle post ( size 2 inch x 2 inch x 9 feet ), nuts & bolts etc. for irrection of the same by 1:1.5:3 cement concrete casting ( 1 feet x 1 feet x 2 feet) below the ground level and painting two or more coats & plastic paint as per specification and direction of the Engineer-in-charge.
221Bus bar distribution box
222Providing and fitting fixing steel sheet enclosed switch fuse unit (suitable for DIN fuses), triple pole with Neutral Link (TPN), 415/500 Volt, L & T / Havells / BCH make etc.complete as per specification and direction of the Engineer-in-charge. i) 32 amps
223Providing , fitting & fixing of Direct on line (Motor starter of L&T / BCH make ( 3 ph, 50 Hz, 415 V , 10 HP/ 7.5 kw Relay range within 13-21 + 10%) in Steel Sheet Enclosure with Contactor complete suitable for submersible Pump as per direction of Engineer in Charge
224Providing and fitting fixing of Moulded Case Circuit Breaker (MCCB) of different Thermal release range , 415 + V, 50Hz (L & T, BCH, ABB make) as per specification and direction of the Engineer-in-charge. 32-40 Amps
225Providing and fitting fixing of moving iron type, Range 0-100/0-200 amps, 96 mm x 96 mm size AC Amps meter direct reading type ( L & T / AE make) with selector switch and CT coil as a electrical instrument of the pannel board as per specification and direction of the Engineer-in-charge.
226Providing and fitting fixing of moving iron type, Range 0-500V, 96 mm x 96 mm size AC Volt meter ( L & T / AE make) with selector switch as a electrical instrument of the pannel board as per specification and direction of the Engineer-in-charge.
227Providing and fitting, fixing of 3 phase indicating lamps fitted with panel board with three different colour lamps with batten holder complete as per specification and direction of the Engineer-in-Charge.
228Providing and fitting fixing with PVC insulated single core multistrand Copper cable conforming to IS : 694 for inter connection with all electrical equipments of the pannel board as per specification and direction of the Engineer-in-charge. i) 10 sqm
229Installation Charge of Air Blower in/c motor etc.
230Providing and fitting fixing of internal electrification and external illumination of Plant building etc. complete
231Supplying and fixing of following luminaries complete with necessary accessories and connection etc. as required (Commercial lighting fixtures with 50,000 burning hours):-a) Box type single FTL fittings of CRCA steel sheet housing complete with 36/40 W FTL, electronic ballast and high quality reflector cover : -
232Supplying & installation of 380 mm sweep 900 rpm metalic body exhaust fan including connection etc as required (ISI marked) :-
233Supplying & installation of 450 mm sweep 1400 rpm metalic body exhaust fan including connection etc as required (ISI marked) :-
234Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required:-
235Supplying & installation of shutter for 380/450 mm sweep metalic body exhaust fan in the existing hole as required:-
236Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W) : -
237Installation, testing and commissioning of ceiling fan including wiring the down rod of standard length (up to 30 cm) by 2 x 1.5 Sq.mm PVC insulated copper conductor cable(FR) etc as required.
238Supplying and fixing of 20 mm dia extra down rod (GI Pipe Medium Guage) with necessary hole for installation of ceiling fan as required.
239Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:-(a) 25 mm dia
240Supplying and fixing of the following Lamps & accessories including connection etc. as required. 400 watt HPSV lamp:-
241Supplying and fixing of the following electrical accessories including necessary connection etc. as required. 32 amps DP kit kat switch:-
242Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):-6 watt/10 watt LED Bulkhead light with high quality polycarbonate diffuser (IP 65):-
243Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required:-a)63 amps 415 volts TPN main switch (rewireable):-
244Supplying and installation of Bus bar chamber of the following ratings and sizes made of steel sheet enclosure with all accessories including necessary connection etc. as required:-a) 63 amps 415 volts four strip Copper busbar chamber 6 ways of size (455mmx330mmx120mm):-
245Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required.a)(2+6) / 8 way SPN MCB DB (single door):-
246b) (2+4) / 6 way SPN MCB DB (single door):-
247Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as required:-a) 6 to 32 amp SP MCB : -
248b) 40 amps DP MCB
249Supplying of ‘U’ clamp made with 40mm x 6 mm MS flat and fixing with necessary fasten nuts including painting etc as required.
250Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with wooden switch board with bakelite cover and piano type switch including connection etc as required:-a) Short point: -
251b) Medium point: -
252c) Long point: -
253Providing and fixing of 3 pin 5/6 amps plug point with piano type 5/6 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on switch board, earthing the 3rd pin etc. as required:-
254Providing and fixing of 3/6 pin15/16 amps plug point with piano type 15/16 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable (FR) on switch board, earthing the 3rd pin etc. as required:-
255Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required.a) 2 x 1.5 sq.mm: -
256b) 2 x 2.5 sq.mm : -
257c) 2 x 4 sq.mm: -
258d) 4 x 4 sq.mm: -
259Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12\\"x 12\\" having locking arrangement including CC work, holes on earth pipe etc. as required.
260Supplying and drawing 4 sq. mm Copper conductor wire along with other wire for loop earthing including connection etc. as required.
261Proving and fixing / drawing of 4.06 mm dia (8 SWG) G.I. wire on surface or in existing G.I/ PVC/ Polythene pipe for loop earthing as required.
262Providing and fitting fixing of internal electrification and external illumination of Plant building etc. complete
263Charges for non-pressure NP2 class(light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 sand:cement: 2 fine) including testing of joints etc. complete. a) 450 mm dia
264Excavating trenches of required width for pipes, cables etc. including exacavation for sockets, dressing of sides where required, ramming of bottoms, depth upto 1500 mm including getting out the excavated soil and backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil with all required leads as per Chapter - 2 of CPWD specification and direction of the Engineer - in - charge. a. In all kinds of soil a) For pipes exceeding 300 mm dia but not exceeding 600 mm dia
265Supporting Block (20 nos)Earthwork in excavation by mechanical means(Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including disposal of excavated earth, lead upto 50 m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soil
266Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete.All kinds of soil
267Providing and laying in position cement of concrete specified grade excluding the cost of centring and shuttering- All work upto plinth level:ii) 1 : 1.5: 3 ( 1 cement : 1.5 fine sand : 3 graded well burnt brick aggregate of 20 mm nominal size)
268Inspection chamber(6 nos)Earthwork in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan ) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil, and disposal of surplus excavated soil as directed, within a lead of 50 m. i) All kinds of soil
269Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidationg each deposited layer by ramming and watering, lead upto 50m and lift upto 1.5 m. i) All kinds of soil
270Providing and laying in position cement of concrete specified grade excluding the cost of centring and shuttering- All work upto plinth level:i) 1 : 3 : 6 ( 1 cement : 3 fine sand : 6 graded well burnt brick aggregate of 40 mm nominal size)
271Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level.i) 1 : 1 : 2 ( 1 cement : 1 fine sand : 2 graded stone aggregate of 20 mm nominal size)
272Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete upto plinth leveli) Thermo-mechanically treated bars of Grade 500-D or above
273Reinforcement for RCC works including straightening, cutting, bending placing in position and binding all complete above plinth leveli) Thermo-mechanically treated bars of Grade 500-D or above
2746 mm cement plaster of mixi) cement mortar 1:4 ( 1 cement : 4 fine sand )
275Neat cement punning.
276Centering shuttering including struttings, propping etc. and removal of form work for :i)Foundations, footings, bases for columns etc.for mass concrete with timber plank
277Testing, trial run and commissioning
278Providing and applying of different chemicals for production of quality treated water as per guideline of WHO/BIS parameters.i) Alum (garde -I) m/c 15-16% alumina contect
279ii) Hydrated Lime (Grade-I)Dose 12 mg/litre
280Providing and mixing bleaching powder grade-I, active chlorine should be minimum 33% (16 hours operation) X 30 days in/c applying, loading and stacking etc. complete in all respect as per direction of the Engineer in Charrge .
281Providing salt for generation of chlorine solution (hypo) as per direction of the Engineer in Charge
282Operation of VT pump at Intake well by deploying pump operator to ensure daily supply of raw water to Plant in two shift operation in/c. operation of s/valves etc.
283Operation of plant by deploying pump operator and helper for chlorination, alum dosing, clari-floculator, back washing & cleaning of total plant as per requirement in/c operation of s/valves as per direction of the Engineer-in-charge.i) Pump Operator
284ii)Helper
285iii) Electrician
286iv) Helper
287Items as per approved Drawing
288For construction of RCC Abutment for (30.0+25.0) mtr steel foot bridge along with pier.Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
289Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete.
290Backfilling behind abutment, wing wall & return wall complete as per drawings, clause 710.1.4 of IRC:78 & MoRT&H technical specification Clause 2200.Sandy material
291Providing weep holes in brickmasonry/ stonemasonry, plain/ reinforced concrete abutment, wingwall, returnwall with 100 mm dia AC pipe or UPVC pipe (110 mm OD of 6.0 kg/cm2 pressure) extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and MoRD technical specification clauses 614, 709, 1204.3.7.
292Providing & laying filter media with jhama brick aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil & bigger size towards the wall & providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and MoRT & H technical specification clause 2504.2.2
293For PST cum Cascade Aerator of 1.2 MGD Capacity SWTPSteel work welded in built up section/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. complete as required :-I) In grating, frames, guard bar, railing, brackets, gates and similar works, all complete.
294For Clear water reservoir & pump house including pump sets, gentry girder, chain pully block, etc.Grading roof for water proofing treatment complete as required as per direction of the Engineer-in-charge with : Cement concrete 1:2:4 (1 cement : 2 fine sand : 4 graded stone aggregate 20 mm nominal size)
295For Surface Drain & Plinth Protection of 1.2 MGD Capacity Surface Water Treatment plantFirst class brick work in foundation and plinth including cost of materials as required complete:- i)In Cement mortar 1:6 ( 1 cement : 6 fine sand )
296For providing all internal sludge lines, complete with pits etc and connection to the central sludge well. Providing and laying Double flanged (screwed/ welded) centrifugally (Spun) cast iron , class B (IS:1536) as per CPWD specification and direction of the Engineer-in -Charge.i) 300 mm dia Ductile Iron Doubled flanged
297iii) 125 mm dia Ductile Iron Doubled flanged
298Lighting of Plant Units and Outdoor Yard Lighting etc.Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:-12 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :-
299Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):- 36 watt LED street light fixture with integral driver and secondary lens (IP66)
30090 watt LED street light fixture with integral driver and secondary lens (IP66)
301120 watt LED street light fixture with integral driver and secondary lens (IP66)
302Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required.
303Retaining Wall of 4.0 m heightEarthwork in excavation for structures as per drawing and MoRD technical specifications Clause 305.1 including setting out, construction of shoring & bracing, removal of stumps & other deleterious material and disposal upto a lead of 50 m, dressing of sides & bottom and backfilling in trenches with excavated suitable material.I Ordinary Soil(i) Upto 3 m depth
304Filling in foundation trenches as per drawing & MoRD technical specification Clause 305.3.9, 1200.
305Providing concrete for plain/reinforced concrete in open foundations complete including formwork as per drawings & MoRD technical specifications Clauses 802, 803, 900,1202 and 1203. (including centering, shuttering, staging etc. but excluding reinforcement).P.C.C grade M 10(i) Nominal mix 1:3:6
306Supplying, fitting & placing Thermo-Mechanically treated bar/ Cold twisted deformed steel bar reinforcement infoundation complete as per drawings & MoRD technical specifications Clauses 1000 & 1202.
307Supplying, fitting & placing Thermo-Mechanically treated bar/ Cold twisted deformed steel bar in substructure complete as per drawings & MoRD technical specification Clauses 1002, 1005, 1010 and 1202.
308Providing concrete for plain/reinforced concrete in open foundations complete including formwork as per drawings & MoRD technical specifications Clauses 802, 803, 900, specifications 802, 803, 900, 1202 and 1203. (including centering, shuttering, staging etc. but excluding reinforcement).R.C.C grade M 25
309Plain/reinforced cement concrete in substructure complete including formwork as per drawings & MoRD technical specification Clauses 802, 804, 805, 806, 807, 900, 1202 & 1204. (including centering, shuttering, staging etc. but excluding reinforcement)R.C.C grade M 25
310Upto 5m heightProviding weep holes in brick masonry/ stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe or uPVC pipe (110 mm OD of 6.0 kg/cm2 pressure) extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and MoRD technical specification clauses 614, 709, 1204.3.7.
311Providing & laying filter media with jhama brick aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil & bigger size towards the wall & providing over the entire surface behind abutment, wing wall, over the entire return wall to surface the full height, compacted to firm condition complete as per drawing and compacted firm condition complete MoRD technical specification clause 1204.3.8.
312Backfilling behind abutment, wing wall & return wall complete as per drawings & MoRD technical specification Clause 1204.3.8.Sandy material
313Boundary Wall
314Earthwork in excavation by mechanical means (Hydraulic Excavator)/manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms,lift up to 1.5m, including getting out the excavated and disposal of surplus excavated soil as directed, within a lead of 50m. i) All kinds of soil
315Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidationg each deposited layer by ramming and watering, lead upto 50m and lift upto 1.5 m.All kinds of soil
316Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete.
317Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level: i) 1 : 3 : 6 ( 1 cement : 3 fine sand : 6 graded well burnt brick aggregate of 40 mm nominal size)
318Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level. i) 1 : 1 : 2 ( 1 cement : 1 fine sand : 2 graded stone aggregate of 20 mm nominal size)
319Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcementi) 1:1:2 ( 1 Cement: 1 fine sand : 2 graded stone aggregate 20 mm nominal size)
320Reinforced cement concrete work in beams, suspended floors, roofs having slope 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement- i) 1 : 1 : 2 ( 1 cement : 1 fine sand : 2 graded stone aggregate of 20 mm nominal size)
321Reinforcement for RCC works including straightening,cutting,bending placing in position and binding all complete above plinth level i) Thermo-mechanically treated bars of grade Fe-500 D or more
322Reinforcement for RCC works including straightening,cutting,bending placing in position and binding all complete upto plinth level i) Thermo-mechanically treated bars of grade Fe-500 D or more
323First class brick work in foundation and plinth including cost of all materials as required complete i) In cement mortar 1:4 ( 1 cement : 4 fine sand ).
324Half brick masonry work with first class bricks in foundation and plinth including cost of all materials as required complete: In cement mortar 1:4 ( 1 cement : 4 fine sand ).
3256 mm cement plaster of mix Cement mortar 1:4 ( 1 cement : 4 fine sand )
32612 mm cement plaster of mix i) Cement mortar 1:4 (1 cement : 4 fine sand
32715mm cement plaster on the rough side of single or half brick wall of mix: i) Cement mortar 1:4 (1 cement : 4 fine sand
328Neat cement punning.
329Finishing walls with water proofing cement paint of required shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :New work ( two or more coats applied @ 3.84 kg/10 sqm)
330Centering shuttering including strutting, propping etc. and removal of form work for : i)Foundations, footings, bases for columns etc. for mass concrete with steel formwork.
331ii) Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply.
332iii) Columns, Pillars, Piers, Abutments, Posts and Struts with shuttering ply
333Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete. Ii) Fixed to openings /wooden frames with rawl plugs screws etc
334Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. complete as required:-In grating, frames, guard bar, railing. brackets, gates and similar works, all complete
335Dismantling of Brick soling Dismantling of brick soling, stacking serviceable materials and unserviceable materials separately with all lifts and upto a lead of 500 m by manual means as per MoRD Technical Specification Clause 202.
336Charges for Brick solingLaying flat brick soling on prepared subgrade (excluding the cost of bricks but including the cost of binding materials) according to lines, grades and cross-section shown on the drawing, filling joints with Earth, free from clay with a Plasticity Index not exceeding 6, watering and rolling the same with three wheeled road roller 80-100 kN as per MoRD Technical Specification Clause 412. Please Enable Macros to View BoQ information

Other Detail

Information Source http://tripuratenders.gov.in
Download FileName File Description File Size
Download 43c6e1e5-6fe4-4ca1-a1ef-9bb9d1269517.html Tender Documents 0 KB
Download Annx.pdf Tender Documents 0 KB
Download BOQ_73048.xls Tender Documents 0 KB
Download DNIeT_04_CE_Const_WTP_JAM_1.pdf Tender Documents 0 KB
Download Tendernotice_1 (5).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.