Tender for annual repair maintenance Ggsip University, Dwarka C Us, New Delhi. Sh: Comprehensive Maintenance Of Electrical Works In Dwarka C Us

Key Dates

Publish Date 24-03-2026
Last Date of Bid Submission 30-03-2026
Tender Opening Date 30-03-2026

Contact Information

Company Name Guru Gobind Singh Indraprastha University
Contact Person EE(E),UWD, GGSIPU, Sector 16C, Dwarka, New Delhi
Address EE(E),UWD, GGSIPU, Sector 16C, Dwarka, New Delhi

BOQ Items

Name of Work:- ARMO GGSIP University, Dwarka C us, New Delhi. SH: Comprehensive maintenance of Electrical works in Dwarka C us
Sl. No. Item Description
1Carrying out maintenance of internal and external electrical installation like plug points, fans, light fixtures, LT panels Street lights, Feeder pillars etc by deploying following manpower as per Staff Deployment schedule fixed by Engineer-in-charge including material required for maintenance all complete including incidental expenses, profit, overhead, taxes, uniform, shoes, consumables, tools/tackles etc as per direction of engineer-in-charge. [Material for maintenance to be paid separately, Statutory obligation like ESI, EPF, Gratuity, paid leave/holidays, Bonus (if applicable) to be reimbursed separately]. Skilled (Wireman)
2Carrying out maintenance of internal and external electrical installation like plug points, fans, light fixtures, LT panels Street lights, Feeder pillars etc by deploying following manpower as per Staff Deployment schedule fixed by Engineer-in-charge including material required for maintenance all complete including incidental expenses, profit, overhead, taxes, uniform, shoes, consumables, tools/tackles etc as per direction of engineer-in-charge. [Material for maintenance to be paid separately, Statutory obligation like ESI, EPF, Gratuity, paid leave/holidays, Bonus (if applicable) to be reimbursed separately]. Unskilled (Helper/Beldar)
3To Supervision of day to day record of complaints material consumed in day to day maintenance, to supervise the work allocated to workers, generating day summary and supervise the preventive maintenance and preparing the preventive maintenance records by deploying supervisor as per direction of Engineer-in-charge (1 job of 8 hrs. per day)
4Supply of 70 watt MHN/CDM open type compact size copper wound ballast as required.
5Supply of 400 watt MHN/CDM open type compact size copper wound ballast as required.
6Supply of 70watt double ended type metal halide lamp as required.
7Supply of 400 watt single ended type metal halide lamp E-40 cap base as required.
8Supply of Electronic lgnitor super imposed suitable for 70 to 400 watt HPSV/MHN-TD lamp as required.
9Supply of Electronic ballast suitable for 1 x TL36 Watts lamp as required.
10Supply of Electronic ballast suitable for 2 x TL36 Watts lamp as required.
11Supply of Electronic ballast suitable for 4 x TL18 Watts lamp as required.
12Supply of Electronic ballast suitable for 1 x PLC 18 (4pin) Watts lamp as required.
13Supply of Electronic ballast suitable for 1 x PLC 11 (4pin) Watts lamp as required.
14Supply of 11 watts, 4 pin compact fluorescent lamp suitable for 220v, 50 Hz as required
15Supply of 18 watts, 2 pin compact fluorescent lamp suitable for 220v, 50 Hz as required
16Supply of 18 watts, 4 pin compact fluorescent lamp suitable for 220v, 50 Hz as required
17Supply of 36 watts, 4 pin compact fluorescent lamp suitable for 220v, 50 Hz as required
18Supply of 36watts fluorescent tube suitable for 220V 50Hz as required.
19Supply of 18 Watt fluorescent tube suitable for 220V 50Hz as required.
20Supply of ISI mark heavy duty exhaust fan of 300 mm sweep 230 volt 50 HZ 1400 RPM complete with blade, leg guards, rubber pads, louver etc.
21Supply of 400mm sweep 230 volt 50 HZ. Wall bracket fan with oscillating arrangement etc
22Supply of 250 mm sweep, Fresh Air Ventilating fan in plastic body complete with blade, louver etc suitable for 230V A.C. supply etc
23Supply of ISI Marked FRLS PVC insulated single core copper conductor 1. 5 Sq mm
24Supply of ISI Marked FRLS PVC insulated single core copper conductor 4 Sq mm
25Supply of ISI Marked FRLS PVC insulated single core copper conductor 6 Sq mm
26Supply of ISI Marked FRLS PVC insulated single core copper conductor 10 sq mm
27Supply of modular switch/ socket 5/6 amp switch
28Supply of modular switch/ socket 5/6 amp socket
29Supply of modular switch/ socket 15/16 amp switch
30Supply of modular switch/ socket 15/16 amp socket
31Supply of modular switch/ socket Bell push
32Supply of Two module stepped type electronic fan regulator
33Supply of module base and cover plate 1 m/2m
34Supply of module base and cover plate 3 m
35Supply of module base and cover plate 4 m
36Supply of module base and cover plate 6 m
37Supply of module base and cover plate 8 m
38Supply of module base and cover plate 12 m
39Supply of Call bell/buzzer suitable for single phase 230 volt
40Supply of 25AMP modular SP MCB \\"C\\" Curve
41Supply of 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker Single pole
42Supply of 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker Double pole
43Supply of 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker Triple pole
44Supply of 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker Triple pole & neutral
45Supply of 40/63 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker Triple pole & neutral
46Supply of 40/63 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker Four pole
47Supply of 2.5 mfd capacitor
48Supply of following sizes of Aluminium/copper conductor, XLPE insulated, PVC sheathed, armoured cable of 1.1 Kv grade confirming to IS: 7098(Part-I) 1988 with up to date amendments complete as required. 3½x 240 Sq.mm aluminium conductor
49Supply of following sizes of Aluminium/copper conductor, XLPE insulated, PVC sheathed, armoured cable of 1.1 Kv grade confirming to IS: 7098(Part-I) 1988 with up to date amendments complete as required. 3½x 185 Sq.mm aluminium conductor
50Supply of following sizes of Aluminium/copper conductor, XLPE insulated, PVC sheathed, armoured cable of 1.1 Kv grade confirming to IS: 7098(Part-I) 1988 with up to date amendments complete as required. 3½x 150 Sq.mm aluminium conductor
51Supply of following sizes of Aluminium/copper conductor, XLPE insulated, PVC sheathed, armoured cable of 1.1 Kv grade confirming to IS: 7098(Part-I) 1988 with up to date amendments complete as required. 3½x 120 Sq.mm aluminium conductor
52Supply of following sizes of Aluminium/copper conductor, XLPE insulated, PVC sheathed, armoured cable of 1.1 Kv grade confirming to IS: 7098(Part-I) 1988 with up to date amendments complete as required. 3½x 95 Sq.mm aluminium conductor
53Supply of following sizes of Aluminium/copper conductor, XLPE insulated, PVC sheathed, armoured cable of 1.1 Kv grade confirming to IS: 7098(Part-I) 1988 with up to date amendments complete as required. 3½x 50 Sq.mm aluminium conductor
54Supply of following sizes of Aluminium/copper conductor, XLPE insulated, PVC sheathed, armoured cable of 1.1 Kv grade confirming to IS: 7098(Part-I) 1988 with up to date amendments complete as required. 3½x 35 Sq.mm aluminium conductor
55Supply of following sizes of Aluminium/copper conductor, XLPE insulated, PVC sheathed, armoured cable of 1.1 Kv grade confirming to IS: 7098(Part-I) 1988 with up to date amendments complete as required. 3½x 25 Sq.mm aluminium conductor
56Supply of following sizes of Aluminium/copper conductor, XLPE insulated, PVC sheathed, armoured cable of 1.1 Kv grade confirming to IS: 7098(Part-I) 1988 with up to date amendments complete as required.4 X 16 sq. mm aluminium conductor
57Supply of following sizes of Aluminium/copper conductor, XLPE insulated, PVC sheathed, armoured cable of 1.1 Kv grade confirming to IS: 7098(Part-I) 1988 with up to date amendments complete as required. 4 X 25 sq. mm aluminium conductor
58Supply of following sizes of Aluminium/copper conductor, XLPE insulated, PVC sheathed, armoured cable of 1.1 Kv grade confirming to IS: 7098(Part-I) 1988 with up to date amendments complete as required. 4 X 10 sq. mm copper conductor
59Supply of following sizes of Aluminium/copper conductor, XLPE insulated, PVC sheathed, armoured cable of 1.1 Kv grade confirming to IS: 7098(Part-I) 1988 with up to date amendments complete as required. 4 X 16 sq. mm copper conductor
60Supply of following sizes of Aluminium/copper conductor, XLPE insulated, PVC sheathed, armoured cable of 1.1 Kv grade confirming to IS: 7098(Part-I) 1988 with up to date amendments complete as required. 4 X 25 sq. mm copper conductor
61Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3½ X 35 sq. mm
62Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3½ X 50 sq. mm
63Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3½ X 95 sq. mm
64Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3½ X 120 sq. mm
65Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3½ X 150 sq. mm
66Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3½ X 185 sq. mm
67Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3½ X 240 sq. mm
68Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 4 X 16 sq. mm
69Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 4 X 25 sq. mm
70Supplying and making straight through joint with cast resin compound including copper ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required 4x 10 Sq.mm
71Supplying and making straight through joint with cast resin compound including copper ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required 4x 16 Sq.mm
72Supplying and making straight through joint with cast resin compound including copper ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required 4 X 25 sq. mm
73Locating cable fault of under ground L.T. cables of sizes upto 630 Sq.mm with the help of fault locating machine including pin pointing the location of cable fault complete as required as per direction of Engineer in Charge.
74Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required Upto 35 sq. mm
75Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required Above 35 sq. mm and upto 95 sq. mm
76Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required Above 95 sq. mm and upto 185 sq. mm
77Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required Above 185 sq. mm and upto 400 sq. mm
78Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc. in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres.
79Demolishing cement concrete manually/by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-Charge, Nominal concrete 1:3:6 or richer mix ( i/c equivalent design mix)
80Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:2:4 ( 1 Cement: 2 Coarse sand : 4 graded stone aggregate 20 mm nominal size)
81Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meters lead.
82Kota stone slab flooring over 20mm (average)thick base laide over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with basee of cement mortar 1:4 (1 cement : coarse sand) : 25 mm thick
83Rewinding of following fans with suitable size copper wire including dismantling, cleaning, assembling, baking, testing and commissioning etc. and taking away the dismantled material as credit item on buy back basis as reqd. Ceiling fan 48\\"size
84'Rewinding of following fans with suitable size copper wire including dismantling, cleaning, assembling, baking, testing and commissioning etc. and taking away the dismantled material as credit item on buy back basis as reqd. Ceiling fan 56\\"size
85Rewinding of following fans with suitable size copper wire including dismantling, cleaning, assembling, baking, testing and commissioning etc. and taking away the dismantled material as credit item on buy back basis as reqd. Wall fan 16\\" size
86'Rewinding of following fans with suitable size copper wire including dismantling, cleaning, assembling, baking, testing and commissioning etc. and taking away the dismantled material as credit item on buy back basis as reqd. Fresh Air fan (9\\"/10\\" size)
87'Rewinding of following fans with suitable size copper wire including dismantling, cleaning, assembling, baking, testing and commissioning etc. and taking away the dismantled material as credit item on buy back basis as reqd. Exhaust fan 12\\" size
88'Rewinding of following fans with suitable size copper wire including dismantling, cleaning, assembling, baking, testing and commissioning etc. and taking away the dismantled material as credit item on buy back basis as reqd. Exhaust fan 18\\" size
89Replacement of ball bearings of the exhaust fan/ceiling fan of following sizes as indicated below including greasing & testing of fans and taking away dismantled material as credit item on buy back basis as reqd. 6201
90Replacement of ball bearings of the exhaust fan/ceiling fan of following sizes as indicated below including greasing & testing of fans and taking away dismantled material as credit item on buy back basis as reqd. 6202
91Replacement of G.M. Bush of various sizes in fresh air fan/wall fan etc. including testing and taking away the dismantled material as credit item on buy back basis as required.
92Replacement of M.S. Shaft of various size of fresh air fan etc. including testing and taking away the dismantled material as credit item on buy back basis as reqd.
93Replacement of M.S. Shaft of various size of ceiling/exhaust fan/Wall etc. including testing and taking away the dismantled material as credit item on buy back basis as reqd. Please Enable Macros to View BoQ information

Other Detail

Information Source https://govtprocurement.delhi.gov.in
Download FileName File Description File Size
Download b9cdba8a-0cd3-4a6e-9f1d-13c3ee8de160.html Tender Documents 0 KB
Download BOQ_384021.xls Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB