| 1 | Taking down cement plaster on bricks or stone wall / ceiling decayed surfaces of concrete , roof projections or chajjas etc upto triple storey including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 2 | M&L Rendering 15 mm thick on fair faces as per manufacture instruction of brick/concrete surfaces in cement plaster 1:4, by using liquid water proofing compound , finished even and smooth without using extra cement, complete, all as specified and as directed. |
| 3 | M&L Rendering 5 mm thick on concrete surfaces in CM 1:3 finished on even and smooth without using extra cement as in ceiling, Chajja etc.complete all as specified and as directed |
| 4 | Supply only liquid water proofing compound, all as specified and as directed. |
| 5 | M&L Rendering 15mm thick in cement plaster 1:6 on fair faces of brick/concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 6 | Demolition of brick work masonry built in cement mortar including all quoins, pillars etc but excluding ashlars facing, dressed stone work and precast concrete articles complete all as specified and as directed. |
| 7 | M&L Brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 complete all as specified and as directed. |
| 8 | Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness complete all as specified and as directed. |
| 9 | M&L 75 mm thick PCC 1:3:6 type C-2, (using 40mm graded crushed stone aggregate) as in plinth protection finished even and smooth without using extra cement complete all as specified and directed. |
| 10 | M&L 25 mm thick PCC 1:2:4 type B-1, (using 20mm graded crushed stone aggregate) as in sub-base finished fair complete all as specified and directed. |
| 11 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises |
| 12 | M&L Non - skid ceramic coloured jointless tile 400mm x 400mm x 7mm thick as in floors laid over and including 15 mm thick screed bed or bedding layer of cement mortar 1:4, set and jointed in neat cement slurry and pointed in coloured cement to match the colour of tiles complete, all as specified and directed. |
| 13 | M&L Non - skid ceramic coloured jointless tiles 400mm x 400mm x 7 mm thick on vertical surfaces such as skirting /dado etc bedded & jointed in neat cement slurry over and including 10 mm thick backing coat of cement mortar 1:4 and pointed in white or coloured cement to match the colour of tiles complete, all as specified and directed. |
| 14 | Taking down chowkats or frames with shutters (without taking off shutter from the frames) exceeding 1.5 sqm & not exceeding 4 sqm each complete all as specified and directed |
| 15 | M&L Aluminium anodised frame for door of size 124.6x44.45 mm made out of 1.60 mm thick aluminium section, poweder coated minimum thickness 50 micron fixed to floor/wall with plugs and screws, complete all as specified and directed. |
| 16 | M&L Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc, complete all as specified and directed. |
| 17 | S & F 5.5 mm thick Sheet glass tinted and glazing with glazing clip, rubber packing etc complete in squares not exceeding 0.5 Sqm in each pane complete all as specified and directed. |
| 18 | Dismantling of plain or Corrugated steel sheeting any gauge, thickness includsing Nanital or similar patten roof coverings complete all as specified and directed. |
| 19 | S&F prepainted galvalume aluminium zinc coating G.I based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 MPa as in roof covering /cladding to wall, fixed with self taping screws complete all as specified and directed. |
| 20 | S&F 0.80 mm thick plain , galvanised , mild steel sheeting , in ridges, hips, valley gutters, drip and straight flashing ( length and girth as fixed ) of class -3, all as specified. |
| 21 | Dismantling and brecking up drain pipes, internal dia of pipe 100 mm (Salt glazed ware,AC or reinforced concrete) set in cement mortar complete all as specified and directed. |
| 22 | S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes duble socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 23 | S&F PVC (SWR) bends any radius 110mm bore with access door complete all as specified and directed. |
| 24 | Dismantling structural steel work as in gate, door, rolling shutter etc complete all as specified and directed. |
| 25 | S & F Steel rolling shutters of 1.25 mm thickness laths without ball bearing as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer erected in position as indicated complete gear operated type with bevel gear box and crank handle complete all as specified and directed. |
| 26 | M&L for 150 mm thick Cement concrete type B 2, 1:2:4 (using 40 mm graded granite stone aggregate) in hard standing finishing the surface even and smooth without using extra cement. |
| 27 | M&L for plain Cement Concrete Type C2 1:3:6 (using 40 mm graded stone aggregate) in surface channels and drains complete all as specified and directed. |
| 28 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads. |
| 29 | S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 Sqm in each pane complete all as specified and as directed. |
| 30 | M&L for 18/19mm thick Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with nails to timber frame work and in moudular kitchen etc all as specified and directed. |
| 31 | S &F 40 mm wide flaps Continuous (piano) hinges , mild steel bright finish or electrogalvanised as in cup boards, kitchen cabinat , etc all as directed. |
| 32 | S&F ball catches with 8mm dia steel ball, and brass body and stricking plate inccluding letting complete all as specified and directed. |
| 33 | S&F hasp and staple 75mm safety type aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws all as specified and directed. |
| 34 | Dismantling wrought iron or mild steel as chanel work of any description not otherwise complete all as specified and directed. |
| 35 | S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe 410 W (gde E-250) complete all as specified and directed. |
| 36 | Dismantling wall and ceiling boards (fiber, pulp, insulation etc) or insulation boards/slabs/blankets any thickness complete all as specified and directed. |
| 37 | M&L for 5mm thick plain colour PVC sheet (wall Panelling) in strips & channel feathered at the edges for fixing on Solid PVC Wall Lining,Insulated PVC Wall Lining, and Solid PVC Partitions inclusive of Solvent Cement and fixing at site complete all as specified and directed. |
| 38 | M&L suspended false ceiling system using E grid suspended ceiling grid system Grid size 600mm x 600mm with and including G.I frame work of main runners 38mm x 24 mm , cross tee 28mm x 24mm and wall angle 24mm x 24mm hot diped galvanised steel with zinc coating not less than 120 gm/ sqm using 4mm thick high pressure steam cured fibre cement pre primed textured variant E board classic ISI marked IS-14862-2000 to be placed in grid of E grid suspended ceiling grid system duly suspended by 6 mm dia gi bar hangers from existing purlins to roof with butterfly clips complete allas specified and directed. |
| 39 | Demolition of reinforced cement concrete, shelves, chajjas, slabs and similar work carefully and matching to adjoining disturbed surfaces complete all as specified and directed. |
| 40 | M&L for RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in slabs supported on walls, beams and colums, in floors, roofs, landing balconies, canopies, deck slabs, chajja and in shelves and the like, complete all as specified and directed. |
| 41 | M&L for complete removal of existing treatment from internal wall/ceiling surfaes and applying two coat of oil bound distemper over 1mm thick of wall care putty complete all as specified and directed. |
| 42 | M&L for preparation of newly plastered surface of walls including corners and applying two coats of distemper oil emulsion over applying of 1 mm thick wall care putty finish wall surface even & smooth all as specified and directed. |
| 43 | M&L preparation of old painted steel surface of any description, over 10 cm in width or girth not other wise described, and applying one coat of synthetic enamel paint all as specified and directed. |
| 44 | M&L Preparation of new painted steel surface of any description, over 10 cm in width or girth not other wise described, and applying one coat of synthetic enamel paint over one coat of red oxide primer all as specified and directed. Please Enable Macros to View BoQ information |
| 45 | M&L Preparation of new painted steel surface of any description, over 10 cm in width or girth not other wise described, and applying one coat of synthetic enamel paint over one coat of red oxide primer all as specified and directed. Please Enable Macros to View BoQ information |