| 1 | Earth work in hard soil or gravelly soil within 50m. Initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm laying in layers not exceeding 0.3m in depth and as per the direction of the Engineer-in-charge and as per direction of the Engineer-in-charge |
| 2 | Conveyance of excavated earth materials by mechanical means including 5km lead complete including all labour, materials & royality etc. complete as per direction of EIC. |
| 3 | Providing Antitermite treatments as per ISI specification including making holes 3'0\\" C/C both ways injecting chemical with water in propertion(1:20) or any approved propertion by the EIC & treatment to choukath sides & wall junction. Cost & conveyance of all materials, labours, T&P etc complete. as per direction of EIC. |
| 4 | Sand filling in foundation and plinth including cost of all material, labour, conveyance, loading and unloading, taxes, royalties, sundries, tools and plants etc. complete as per the driection of the Engineer in Charge. (linear measurement will be taken and quantity will be calculated on standard weight for all heights). |
| 5 | Filling area with excavated earth materials including labour, conveyance, loading and unloading, taxes, royalties, sundries, tools and plants etc. complete as per the driection of the Engineer in Charge. |
| 6 | Providing and laying of 80mm thick factory made cement concrete interlocking paver block of M35 grade and approved make variety colour and size made by Block making machin with strong vibratory compaction of approved design and shape, laid in required col |
| 7 | Providing and lying plain cement concrete of proportion (1:3:6) in foundation and floors using Portland slag cement (PSC) with 40 mm. Size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm thick in each layer including cost, conveyance, loading, unloading, royalties and taxes all materials and cost all labours, sundries, T & P required for the work including shoring, shuttering and dewatering if required including hire & running charges of water pump complete as per the instruction of the Engineer-in-Charge. |
| 8 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-20 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position. |
| 9 | (a)Base Footing |
| 10 | (b) Column in s/s |
| 11 | i)Ground Floor |
| 12 | II)First Floor |
| 13 | iii)Head Room |
| 14 | ii)C.wall |
| 15 | ii)Servent Room |
| 16 | (c) Plinth beam |
| 17 | (d) Lintel band |
| 18 | i)Ground Floor |
| 19 | II)First Floor |
| 20 | ii)C.wall |
| 21 | ii)Servent Room |
| 22 | (e) Chajja( at lintel level & window sill level ) |
| 23 | i)Ground Floor |
| 24 | II)First Floor |
| 25 | ii)Servent Room |
| 26 | g) Shelves |
| 27 | i)Ground Floor |
| 28 | II)First Floor |
| 29 | ii)Servent Room |
| 30 | (f) Stair case |
| 31 | i)Ground Floor |
| 32 | (g) Roof Beam |
| 33 | i)Ground Floor |
| 34 | II)First Floor |
| 35 | ii)Servent Room |
| 36 | (h) Roof slab |
| 37 | i)Ground Floor |
| 38 | II)First Floor |
| 39 | ii)Servent Room |
| 40 | Straightening bent up or coiled M.S. rod or HYSD steel (Fe-415 / Fe-500), cutting, bending, cranking, hooking, welding or jointing (if required), the M.S. rod or HYSD steel and binding, tying the grills, hoisting, lowering and placing in proper position as per drawing & design required for R.C.C. works including cost, conveyance and taxes of M.S. rod or HYSD steel and binding wires of 18 to 20 gauge and labour with all T&P required for the work etc. complete as per approved drawing and technical specification and as per clause-1600 of MoSRTH specification for road & bridge works (Latest Revision ) complete in all respect as directed by Engineer-in-Charge.(weight of binding wires will not be considered for payment and payment will be made on weight of M.S. rod or HYSD steel only. Steel bars of only MAJOR INTEGRATED STEEL PLANTS like SAIL, RINL, TATA, JINDAL & SHYAM STEEL, etc. of Fe-415 / Fe-500 grade are to be used in the work & if required original bill of . steel has to be produced by the contractor) |
| 41 | i)Ground Floor |
| 42 | II)First Floor |
| 43 | iii)Head Room |
| 44 | ii)C.wall |
| 45 | ii)Servent Room |
| 46 | First class Fly ash Brick masonry using bricks of size 23 cm. x 11 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix (1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge. |
| 47 | First class Fly ash Brick masonry using bricks of size 23 cm. x 11 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Super stracture including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge. |
| 48 | i)Ground Floor |
| 49 | II)First Floor |
| 50 | iii)Head Room |
| 51 | First class Fly ash Brick masonry using Fly Ash. bricks of size 23 cm. x 11 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix (1:4) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Superstructure including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge. |
| 52 | i)Ground Floor |
| 53 | II)First Floor |
| 54 | Supplying of M.S. Grill made out of structural steel, flats, plates, bars confirming to IS for windows, ventilators etc. as per drawing and design, fixed to walls with clamps including priming 1 coat with all kdamages in walls and floors etc. including cost of all materials, labour, conveyance, taxes, royalties, scaffolding, watering, curing, sundries, tools and plants etc.as per the direction of the Engineer in Charge. |
| 55 | Providing fitting and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Clerestory windows & other Frames/Chowkhat of size 125X65mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade) , calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 grms) fabricated with miter joints after applying PVC solvent cement cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawl strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 300 N/mm2 and resistance to spred of flame of Class A catagory with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length including Fixing chowkhat (Anchor Bolt) in existing opening in brick/ RCC wall with dash fasteners/Chemical fasteners of appropriate size (3 nos on each vertical member of door chowkhat and 2 nos on each vertical member of window chowkhats), including Cost of dash fasteners/ chemical fastener etc complete as per direction of Engineer-in-charge. |
| 56 | Providing and fitting, fixing of 32 mm thick flush door shutters conforming to IS 2002 (Part-1) decorative type, core block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both face of shutters inclussive of 4 nos of stainless steel Butt Hinges (100mm x 60mm x 2.5mm) 40mm stainless steel screws. Cylindrical Look(Godrej-9843), Tower Bolts SS 10mm X 300mm (Bathroom)(Godrej 3264), PVC Door Buffer with SS Screw, teak wood lipping around the edges & paste with 1.5mm thick lam8inate on both side of the flush door, etc., including the cost of all materials, hardware fittings, cost of all labour, convence, loading, unloading, T&P, etc , complete as per the direction of Engineer-in charge. |
| 57 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. (DAR 2021 vol-I Clause No-9.147.D, pg no.516 ) |
| 58 | Providing and fixing factory made uPVC white colour fixed glazed windows/ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in- Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. |
| 59 | Providing 6 mm thick cement plaster in cm (1:4) to RCC surfaces finished smooth including closed deep chipping and slurry treatment including cost of all materials, labour, conveyance, loading and unloading, taxes, royalties, sundries, tols and plants etc. complete as per the driection of the Engineer in Charge. |
| 60 | i)Ground Floor |
| 61 | II)First Floor |
| 62 | iii)Head Room |
| 63 | ii) C.wall |
| 64 | Providing 12mm thick cement plaster in cm (1:6) on the rough surface/ plumbed surface of masonry racking out of joints, scrapping and cleaning the surface and finishing the plastered surface smooth to proper plumbs and level and providing grooves as shown in the drawning including cost of all material, labour, conveyance, loading and unloading, taxes, royalties, sundries, tools and plants etc. complete as per the driection of the Engineer in Charge. |
| 65 | i)Ground Floor |
| 66 | II)First Floor |
| 67 | iii)Head Room |
| 68 | ii) C.wall |
| 69 | Providing 16mm thick cement plaster in cm (1:6) on the rough surface of masonry walls for all floors including racking and joints, scrapping and cleaning the surface and finishing the plastered surface smooth to proper plumbs and level and providing grooves as shown in the drawning including cost of all material, labour, conveyance, loading and unloading, taxes, royalties, sundries, tools and plants etc. complete as per the driection of the Engineer in Charge. |
| 70 | i)Ground Floor |
| 71 | II)First Floor |
| 72 | ii) C.wall |
| 73 | Providing 12mm thick cement plaster in cm (1:4) on the rough surface/ plumbed surface of masonry racking out of joints, scrapping and cleaning the surface and finishing the plastered surface smooth to proper plumbs and level and providing grooves as shown in the drawning including cost of all material, labour, conveyance, loading and unloading, taxes, royalties, sundries, tools and plants etc. complete as per the driection of the Engineer in Charge. |
| 74 | i)Ground Floor |
| 75 | II)First Floor |
| 76 | Supplying, fitting & fixing of Granite Tiles of minimum Above 0.40 sqm. (20mm thick) of approved make in floors laid on 20 mm thick cement mortar (1:4)(1 cement : 4 course sand) and filling joints with slurry for kitchen platforms, vanity counters, facias and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge, making gas pipe hole etc. including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights. In all floors and all heights. |
| 77 | Supplying & fixing of industrial vitrified tiles on 20 mm thick bed of cement mortar (1:4) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights. In all floors and all heights. |
| 78 | Supplying, fitting and fixing vitrified tile in floors of size 600mm x 600mm coloured / printed series of approved make of premium grade having thickness 8mm to 10mm conforming to IS-13756 on 20mm thick bed of cement mortar (1:4) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties and taxes of all materials complete in all respects. |
| 79 | i)Ground Floor |
| 80 | II)First Floor |
| 81 | Supplying, fitting and fixing vitrified wall tiles having dimension 600mm x 600mm coloured / printed series of approved make of premium grade having thickness 8mm to 10mm conforming to IS-13756 as directed by Engineer-in-charge in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties and taxes of all materials complete in all respects |
| 82 | i)Ground Floor |
| 83 | II)First Floor |
| 84 | Supplying, fitting and fixing Chequered tile flooring in floors of approved make laid on 20mm thick C.M (1:4) & filling joints with white cement of approved quality including cost of all materials, takes labour T&P etc required for the work. per 1 sqm (Data for 10 sq.mt.) |
| 85 | Supplying fitting fixing of false ceiling made out of 12.5mm thick P.O.P. Gypsum board fixed with frame made out of G.I. Perimeter channel runners (Gyp steel make or equivalent branded company) etc. and hanged from roof on prepared grid including cost, conveyance and taxes of all materials with cost of labour and T & P required for the work completeas per direction of EIC. |
| 86 | II)First Floor |
| 87 | Supplying fitting fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balstrade of size 32mmx32mmx2mm @0.90mtr C/C and stainless square pipe bracing of size 32mmx32mmx2mm in 3 rows in stair case as per approved design and specification, buffing, pollishing etc with cost, conveyance taxex of all materials, labour, T&P etc. required for the complete in all respect. |
| 88 | i)Ground Floor |
| 89 | II)First Floor |
| 90 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall on interior surfaces to prepare the surface even and smooth as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete. |
| 91 | i)Ground Floor |
| 92 | II)First Floor |
| 93 | Preparing surface and painting at all height with two or more coats of interior Plastic Emulsion \\"Royale Shyne\\" of Asian Paints or equivalent of approved shade as per the instructions of the manufacturers; giving uniform shade etc in all heights of walls etc. including interior wall primer & providing scaffolding, cleaning, curing and supply of all materials and labour complete as per drawing, design and direction of Architect/Engineer-In-Charge. |
| 94 | i)Ground Floor |
| 95 | II)First Floor |
| 96 | Providing and applying to outside walls with two or more coats of Anti-Fungal Weather coat paint over a coat of primer including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-Charge at all elevations including all material labour complete. |
| 97 | i)Ground Floor |
| 98 | II)First Floor |
| 99 | iii)Head Room |
| 100 | ii) C.wall |
| 101 | Painting two coats with any approved synthetic enamel paint of approved quality shade and make over a coat of Red Oxide priming to new wood work / iron work including cost of the primer and paint, sand papering polishing the surface with cost, conveyance and taxes of all materials and labour with T&P required for the work etc. complete in all respect. |
| 102 | i)Ground Floor |
| 103 | II)First Floor |
| 104 | ii) C.wall |
| 105 | 2.5cm (1”) av. thick grading concrete (1:2:2) using 6mm size black hard crusher broken granite chips over roof slab after chipping and chiseling the same and cleaning the surface by brushing laid to proper slope finished smooth to receive tarfelt treatment watering and curing including cost, conveyance, royalties and taxes of all materials with all labour and T&P etc. required for the work complete in all respect in all floors. |
| 106 | i)Ground Floor |
| 107 | I)First Floor |
| 108 | ii)Head Room |
| 109 | Supplying,fitting & fixing of rain water spout using 100mm dia PVC pipe as per technical specifications (Including cutting hole in brick massonary & fixing the pipe with CM (1:4) including all cost, conveyance, taxes, cess,royalties of all materials, cost of all labour, T&P required for the work etc. complete as per specification & direction of Engineer-in-charge. |
| 110 | Providing G.S.B. Gr-VI stone screaning materials, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC and compacting with vibratory roller to achieve the desired density, as per approved Drawing & Technical Specifications and as per Clause - 401 of MoRT&H Specifications for Road & Bridge works (5th Revision) including cost, conveyance, royality & other taxes of materials, cost of labour, machinery, T&P etc complete. |
| 111 | Supplying and fixing of Pre cast kerb stone of size 600mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984. |
| 112 | Filling F&P with excavated materials including all cost, conveyance,royalty & taxes etc.compete of all materials to work site as per specification approved by the department & direction of Engg-in-charge. |
| 113 | Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as g (AR, P-158/37) |
| 114 | ELECTRICAL WORKRecessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor (Make-Havells/Polycab/Finolex/RR Kable ) of ISI marked with 20 mm dia PVC heavy class FRLS non metallic conduit(Make-AKG/Polycab/precision/norpack/sudhakar) with 6A modular type switch(Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) ) ISI marked , and ceiling rose ISI marked of modular type G.I box with cover , of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection .Raw power supply switch board shall be separate from emergency power supply switchboard as per direction of Engineer -in -Charge.Each light point should have provision for ceiling rose & angle holder point. |
| 115 | GROUP-A |
| 116 | GROUP-B |
| 117 | GROUP-C |
| 118 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6Aswitch&socket(modulartype)(Makegrand(Myrius),Schneider(Zencelo),Panasonic(Vision) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. |
| 119 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)(Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. |
| 120 | Supplying,fixing of 16A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type) (Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. |
| 121 | Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6A switch & socket(modular type) ( (anti bactorial & flame retradant type) with suitable size modular box & metallic cover plate (both side)(anti bactorial & falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN)/Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 122 | Supplying,fixing of 3x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+3 nos 6A switch & socket(modular type) ( (anti bactorial & flame retradant type) with suitable size modular box & metallic cover plate (both side)(anti bactorial & falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ legrand( ( Myrius-NEXT GEN)) /Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 123 | Supplying and fixing AC point consisting of 16A socket outlet Modular type along with 25A starter with all connections and accessories as required as per direction of Engg.-in-Charge.(Make-Schneider/Siemens/Legrand) |
| 124 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover. as required as per direction of Engg.-in-Charge. (Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) |
| 125 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (2X1.5+1X1.5) |
| 126 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 127 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 128 | 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic FRLS heavy duty PVC conduit .(PANEL TO BDB EACH QTR) (2X6+1X2.5) |
| 129 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit. (4X6+2X2.5) |
| 130 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 1 nos single core 1.5 sq. mm copper wire for phase in existing conduit (invertor point) |
| 131 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge . |
| 132 | Sub-Head II (Light fitting Fixture & Fan) |
| 133 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep with louvers any other equivalent reputed make star rated as approved) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement warranty shall be 2 years. Make-Havells/Bajaj/Usha/Crompton /Orient |
| 134 | S/F. Of 400mm High Speed Wall fans including all connections and accessories of Usha/Orient/Havells/Equivalent make |
| 135 | Supplying, installation, testing and commssioning of 1200 mm sweep BLDC ceiling fan with aluminium blades having wattage not more than 28W and Air delivery ≥ 215(m3/min) Make-USHA(Technix)/Crompton(Energion Groove)/Havells(Efficiencia Neo ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years . |
| 136 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) |
| 137 | Supplying and fixing extra conduit down rod of 40 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge . |
| 138 | SITC of energy efficient LED tube light fittings with decorative alumunium LED batten along with LED tube light having power rating 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser i/c connection etc as required.The luminaire should be Replacement Warranty will be 2 years panasonic/havells/LT/Bajaj/Phillips/Crompton/Wipro |
| 139 | SITC of Sleek LED 10 watt mirror light fitting with decorative aluminium LED batten having extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.The luminaire should be Replacement Warranty will be 2 yearshavells/Bajaj/Phillips/Crompton/Wipro |
| 140 | SITC of Sleek LED 15 watt LED Lamp complete with all accessories etc. directly on angle holder as required.The luminaire should be Replacement Warranty will be 2 yearshavells/LT/Bajaj/Phillips/Crompton/Wipro |
| 141 | Supply and fixing of 10 Watt LED BH Fitting.The luminaire should be Replacement Warranty will be 2 years (havells/Bajaj/Phillips/Crompton/Wipro) |
| 142 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 143 | Supply and Installation of 2000 VA, 12 V UPS ISI marked in cluding all connections and accessories.(Make-Luminous/Microtek/Livguard/Equivalent) |
| 144 | Supply and Installation of 150 AH tall tubular battery ISI marked.(Make-Luminous/Microtek/Livguard/Equivalent) |
| 145 | Supply and Fixing of Trolley for Double Battery |
| 146 | S/F of Street light- 45W,120 lm/w efficacy , new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) (5Years Warranty). |
| 147 | S/F of Street light- 90W,120 lm/w efficacy , new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover(Make: Havells /Philips/Wipro /Crompton/Bajaj) (5Years Warranty). |
| 148 | BDBS,DB,AC DB,FLOOR PANELS,MCBS |
| 149 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB Itus as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years |
| 150 | 4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years. |
| 151 | Supply and fixing of 8 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years. |
| 152 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 Model of ABB/LK/Hager/C&S/Havells/Panasonic. the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 153 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, DOUBLE POLE MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 Model in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 154 | Supplying and fixing 63 amps rating, 240 volts, C series,10KA breaking capacity, DOUBLE POLE MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 155 | Supplying and fixing 63 Amps rating, 4P, 415 volts, MCB . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 3 years |
| 156 | Supplying and fixing 40 Amps rating, 4P, 415 volts, RCCB 30mA . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .(4W TPN BDB IC). The MCB should be Replacement Warranty will be 3 years |
| 157 | (Earthing) INSTALLATION |
| 158 | Earthing with G.I earth pipe 3 meter long 40 mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangment and watering pipe etc with charcoal and salt as required. |
| 159 | Providing and fixing 8 SWG (4 mm) dia copper wire on surface or in recess for loop earthing as required. |
| 160 | CABLING AND END TERMINATION MAIN AREA |
| 161 | Supplying of one number PVC insulated armoured and PVC sheathed AL. conductor power cable of 1.1 KV grade of following size cables as per direction of Engg.-in-Charge. make-polycab/finolex/Havells/KEI |
| 162 | 4core x 16 sq mm |
| 163 | LAYING OF CABLE |
| 164 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 165 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 166 | Supplying and making end termination with brass comprecision gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 167 | 4core x 16 sq mm |
| 168 | S/F of 63A ICDP Main Switch of Havells/Anchor/HPL/L&T/Equivalent make. Including all coneections and accessories as required. |
| 169 | PANELS |
| 170 | MAIN METERING PANEL |
| 171 | S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit Metering panel) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) BUILDING MAIN)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.3P+N Type 2 SPD 40 kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed.. |
| 172 | Metering-Space for 1 no 10-60A 3PH KWH Meter . |
| 173 | In commer- 01 number of 63 Amps 4P MCCB Icu=100%Ics,,16KA LSIG MCCB with TMR based releaseMake-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula ) with 63A 4P changeover switch (Make-HPL/LK/Siemens/Schneider). |
| 174 | Busbar- 04 numbers of 100Amps Electrolytic al. busbar with 1A/SQ.MM current carring capacity.Busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) |
| 175 | Out going- (i) 63A 2P MCB rating,10 KA breaking capacity,C series, MCB Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) 2 nos |
| 176 | Out going- (iii) 32A 2P MCB rating,10 KA breaking capacity,C series, MCB Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) 2 nos |
| 177 | Instrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse. |
| 178 | (ii) 01 set of digital type multifunction meter with CT for voltage,current,frequency indication . |
| 179 | CABLE TRAY |
| 180 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 181 | 1.5 TR high wall 5 star inverter type split A.C machine (BTU/Hr-18000)with copper condensor & evaporator having ambient temperature 52 degree celcius with comprehensive 1 year warranty,5 years warranty on PCB, 5 years warranty on compressor (Make:O-General/Diakin/Mitsubishi/Hitachi/Carrier) |
| 182 | REFRIGRANT PIPING |
| 183 | Supply,installation of hard/soft copper refregrant piping of size 5/8 inch and 1/4 inch for suction and liquid line with 3 corex4 sqmm FRLS Copper control cable alongwith 25 mm weather proof closed cell nitrile insulation ,complete with fitting of bends and other nesessary material to complete the job. |
| 184 | 1 TR to 3 TR high wall split A.C |
| 185 | FRAME WORK |
| 186 | Supply,installation & fabrication of MS base frame for both indoor and outdoor unit and other nesessary material to complete the job. |
| 187 | 1 TR to 3 TR high wall split A.C |
| 188 | DRAIN PIPING |
| 189 | Supply,installation & fabrication of Insulated drain water piping from indoor to nearestdrain point separate to all and other nesessary material to complete the job. |
| 190 | 25mm nom. Dia pipe |
| 191 | Supply and fixing of 4kVA Voltage stabilizer (Make-V-Guard/Microtek |
| 192 | P.H WORKSupplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge.In Ground Floor (Make - Supreme, Astral ) |
| 193 | 40mm dia CPVC ASTM pipe (sch-80) |
| 194 | 50mm dia CPVC ASTM pipe (sch-80) |
| 195 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor CPVC pipes conforming to IS:15778 having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00. spacing. This includes Jointing of pipes & fittings with one step CPVC solvent cement and testing of Joints all complete as per specification and direction of the Engineer in charge. (Make - Supreme, Astral ) |
| 196 | In ground floor |
| 197 | 20mm dia CPVC pipe |
| 198 | 25mm dia CPVC pipe |
| 199 | 32mm dia CPVC pipe |
| 200 | Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.250mm thick wall |
| 201 | In Ground Floor |
| 202 | GI pipes and fittings/ PVC pipes and fittings etc |
| 203 | GI pipes and fittings/ PVC pipes and fittings etc |
| 204 | Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thick for passing GI pipes / PVC pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4) including finishing complete so as to make it leak proof as per direction of the Engineer in charge. |
| 205 | In Ground Floor |
| 206 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/ PVC pipes and making good the damages as per the direction of the Engineer in charge. |
| 207 | Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge.(C.P.fittings are Jaquar make) |
| 208 | 15 mm dia CP two way Bib cock (Jaquar) FLR-CHR-5041N |
| 209 | 15mm dia CP Health foucet (Hindware- F160059CP) |
| 210 | 15 mm dia CP Long body Bib cock(Jaquar)CON-CHR-049NKN |
| 211 | 15mm dia CP angle stop cock(Hindware - F320006CP) |
| 212 | 20mm dia CP concealed stop cock(Jaquar)CON-CHR-083FTK |
| 213 | 25mm dia brass or gun metal fullway valve(Leader / Kriti Make) |
| 214 | 40mm dia brass or gun metal fullway valve(Leader / KritiMake) |
| 215 | 32mm dia brass or gun metal fullway valve(Leader / Kriti Make) |
| 216 | 50mm dia brass or gun metal fullway valve(Leader / Kriti Make) |
| 217 | 15mm dia CP flange |
| 218 | 15mm dia CP extension piece |
| 219 | Sink cock(Jaquar)FLR-CHR-5015 |
| 220 | Grab Bar (Jaquar - WAC-SAP-BAI090CS ) |
| 221 | Urinal Flush Valve(Jaquar)PRS-CHR-077 |
| 222 | Supplying all materials, labour, T&P and fitting and fixing CP shower with 15mm or 20mm inlet with CP shower arm including polishing all complete as per specification and direction of the Engineer in charge.15mm dia CP revolving shower With shower arm(Jaquar)OHS-CHR-1661+SHA-CHR-083 |
| 223 | Supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level Single flushing cistern (Hindware) with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge. 10 litres capacity pvc low level cistern with 32mm dia CP long flush bend Slimline white (Make - Jaquar , Hindware & Parryware) |
| 224 | Supplying all materials, labour, T&P and fitting and fixing PVC soil waste ventilating pipes and fittings of the following with suitable clamps as per specification and direction of the Engineer in charge (Make - Supreme ,Ori Plast & Ajaya )100mm PVC Pipe |
| 225 | 110mm PVC D/Jn door(Ori Plast/Ajaya /Supreme Make) |
| 226 | 110mm PVC Plain tee(Ori Plast/Ajaya /Supreme Make) |
| 227 | 110mm PVC door bend(Ori Plast/Ajaya /Supreme Make) |
| 228 | 110mm PVC Plain bend(Ori Plast/Ajaya /Supreme Make) |
| 229 | 110mm PVC ‘P’ Trap(Ori Plast/Ajaya /Supreme Make) |
| 230 | 110mm PVC offset without ear(Ori Plast/Ajaya /Supreme Make) |
| 231 | 100mm dia Cowl |
| 232 | 125mm dia grating |
| 233 | 110mm PVC Socket(Ori Plast/Ajaya /Supreme Make) |
| 234 | 75mm dia Pipe |
| 235 | 75mm PVC Plain tee(Ori Plast/Ajaya /Supreme Make) |
| 236 | 75mm dia Plain Bend |
| 237 | 75mm PVC Socket(Ori Plast/Ajaya /Supreme Make) |
| 238 | Clamp |
| 239 | Supplying all materials, labour, T&P and fitting and 2000 liters capacity PVC water storage tank complete as per specification and direction of the Engineer in charge. |
| 240 | Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) (Hindware - 20042) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x 30mm footrest, fixing 100mm dia HCI ‘P’ or ‘S’ trap (with/without 50mm dia horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc all complete as per specification and direction of the Engineer in charge. 580mm size Orissa pan (Parryware / Hindware make ) |
| 241 | Supplying all materials, labour, T&P and fixing vitreous china water closet, European water closet (Hindware 20044) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal, fixing 100mm dia HCI ‘P’ or ‘S’ trap (with/without 50mm dia horn) for water closet European pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc all complete as per specification and direction of the Engineer in charge. European pan (Parryware / Hindware make ) |
| 242 | Supplying all materials, labour, T&P and fixing wash Laboratory sink , fixing 50mm/40mm dia CP brass waste, fixing 50mm/40mm dia PVC waste pipe 910mm long with supply of wooden plugs, screws and cement etc including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in charge. 600mmx450mmx250mm size Laboratory sink |
| 243 | Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps (Hindware 10049) with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of the Engineer in charge. 490x400mm size under counter top wash hand basin |
| 244 | Supplying all materials, labour, T&P and fixing mirror (Parryware Cat. no - C862099) of superior glass mounted minimum 5mm thick on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge. |
| 245 | 600mmx450mm size B.E mirror (Jaquar make) |
| 246 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail (Jaquar Cat. no - ACN-ACR-1111SM) complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge.25mmx600mm long CP towel rail |
| 247 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf (Jaquar Cat. no - ACN-CHR-1171N) with CP brass brackets and guard rails complete fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge. |
| 248 | 600x125mm plate glass shelf with CP guard rails |
| 249 | Supplying and fixing urinal of hindware make having cat no 60001 or equivalent type of approved make with division plate of hindware make having cat no 60011 or equivalent including all fittings like 450mm long connection pipe of Jaquar make having cat no ALD 803B, waste pipe etc of approved make etc complete as per PH specification and direction of the Engineer-in-charge. |
| 250 | Supplying and fixing squatting urinal of hindware make having cat no 60003 or equivalent type of approved make with division plate of hindware make having cat no 61001 or equivalent including all fittings like 450mm long connection pipe of Jaquar make having cat no ALD 803B, waste pipe etc of approved make etc complete as per PH specification and direction of the Engineer-in-charge. |
| 251 | C.P. Ring towel ring (Jaquar Cat. no - ACN-1121N) |
| 252 | Supplying all materials, labour, T&P and fixing CP soap holder (Jaquar Cat. no - ACN-ACR-1131N) complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge. CP soap holder |
| 253 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In Ground Floor |
| 254 | Ground Floor |
| 255 | First Floor |
| 256 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.In Ground Floor |
| 257 | Ground Floor |
| 258 | First Floor |
| 259 | Supplying the waterproofing material Pidifin 2K of Dr.fixit on equivalent water proofing material and appling in two coat over the concrete floor and dado upto 1\\"-6\\" in wall including cleaning,applying and mending as per specification including all labour charges as per direction of Engineer-in-charge. |
| 260 | Ground Floor |
| 261 | First Floor |
| 262 | Supplying all materials, labour, T&P and providing ceramic tiles in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. size 30 x 30 cm Kajaria / equvalent to be pree approved .In Ground Floor |
| 263 | Ground Floor |
| 264 | First Floor |
| 265 | Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in chargeKajaria / Somany of size 30 cm x 45 cm In Ground Floor |
| 266 | Ground Floor |
| 267 | First Floor |
| 268 | Factory made single leaf rigid FRP(alternately called GRP) sandwich composite door shutter of 32mm thick laminated with two GRP skins with wood grain finish fabricated using UV-stabilised Isopthalic Gelcoat and one layer of 450 gsm E-glass Chopped Strand Mat (CSM) impregnated with orthopthalic palyester resin. The thickness of the skins shall not be less than 3.00mm Expanded Polystyrone(EPS) structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material. Wooden reinforcements made of seasoned sal wood block of cross section not less than 28mmx32mm and also necessary sal wood reinforcements for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, the sal wood reiforcements and the skins. The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters tested in conformation to IS: 4020-1998. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter with FRP frame of size 45x90mm.(Darwaja /Exon Door make) |
| 269 | 4x0.75x2.10= |
| 270 | 4x0.75x0.60= |
| 271 | EXTERNAL P.H. WORK.Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge.160mm all round concrete |
| 272 | Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, KB brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge.Inside size 250mmx250mm |
| 273 | Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, Ground class fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 600mmx600mmx450mm |
| 274 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge 1.20m dia x 2.00m deep soakway pit |
| 275 | Construction 1 nos 50 users RCC Septic tank |
| 276 | Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge. |
| 277 | Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -charge |
| 278 | Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge. |
| 279 | Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge |
| 280 | Supplying all materials, labour, T&P and providing cement concrete (1:1:5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 281 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 282 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 283 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 284 | Supplying all materials,labour,T&P and providing 12mm CP (1:4) with cement punning on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 285 | Supplying all materials, labour, T&P and providing,fitting and fixing 100mm x 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification and direction of the Engineer in charge |
| 286 | Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge. |
| 287 | Back Filling the foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge |
| 288 | Sinking of 125mm x 50mm dia tubewell through hand boring (water jet ) method .Supplying all materials, labour, T&P and setting up boring equipments including erection of suitable staging for installation of the required size of tube well, dismantling and removing the same after complection of the work, including transportation of the boring equipments, cleaning and levelling the site, excavation of mud pit, channels etc, levelling of site all complete as per direction of Engineer in charge |
| 289 | Supplying all labour, T&P and transporting the boring pipes, top casing , grouting pipes, P.V.C pipes and fittings, P.V.C well screens, cement, bentonite and gravels etc to the worksite including loading and unloading etc all complete as per direction of Engineer in charge |
| 290 | Supplying all labour, T&P and drilling pilot bore not less than 102mm dia, without casing pipes in all kinds of soils and rocks for the following depths excluding supply of necessary boring pipes including supply of necessary cutting equipments, extra sockets (whenever required) etc and withdrawing the boring pipes, washing and keeping the bore clear for logging if required all complete as per direction of Engineer in charge. Drilling pilot bore from 0 to 360 metres |
| 291 | Supplying all labour, T&P and reaming the pilot bore to the following sizes and depths without casing pipes including withdrawing the boring pipes, washing the bore by means of pipe cylinder etc all complete as per direction of Engineer in charge Reaming 100mm to 150mm dia from 0 to 360 metres |
| 292 | Reaming 150mm to 200mm dia from 0 to 360 metres |
| 293 | Supplying all labour, T&P and jointing materials and lowering the 300mm dia top casing pipes into the position and removing the same after use all complete as per direction of Engineer in charge from 0 to 360 metres |
| 294 | Supplying all labour T&P and grouting with cement slurry for saline sealing in the bore around the 150 mm dia PVC casing pipe etc all complete as per the direction of the Engineer in charge. |
| 295 | Supplying all labour, T&P and jointing materials and lowering the pvc casing pipes, fittings and well screens in position, including fitting and fixing of centraliser, cutter plug and washing the bore all complete as per direction of Engineer in charge 160mm dia PVC casing pipe from 0 to 360 metres |
| 296 | Cost of 125mm dia PVC ASTM pipe (sch-80) |
| 297 | 63mm dia PVC casing pipe from 0 to 360 metres |
| 298 | Cost of 50mm dia PVC ASTM pipe (sch-80) |
| 299 | Cost of 50mm dia PVC well screen |
| 300 | Cost of 50 mm dia C.I. cutter plug |
| 301 | Cost of bentonite powder |
| 302 | Supplying all materials, labour, T&P and packing the bore with washed gravel of river shingles of required size and specification around the well screen and pipe etc all complete as per the direction of the Engineer in charge |
| 303 | Cost and Conveyance of Gravel |
| 304 | Supplying all materials, labour, T&P and packing the bore with river sand over the gravel pack etc all complete as per the direction of the Engineer in charge |
| 305 | Cost and Conveyance of sand |
| 306 | Supplying all labour T&P and grouting with cement slurry for sanitary sealingin the bore around the upper most 3 metres of 150mm dia PVC casing pipe etc all complete as per the direction of the Engineer in charge. |
| 307 | Cost of Cement |
| 308 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge By Compressor |
| 309 | Supplying all materials, labour, T&P and constructing Bore well protection chamber of the inside size 650x650x1000hight with cement concrete (1:3:6) using 40mm size hard granite metal on foundation, 1st class Fly ash brickwork in cement mortar (1:3), with base cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:4) inside and outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. |
| 310 | Supplying all materials, labour, T&P and providing, fitting and fixing verical submersible pump to run on 3 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, etc all complete as per direction of the Engineer in charge (Texmo/ KSB/Kirloskar make) |
| 311 | 3 H.P. three phase 3 stage head -60 M, with discharge capasity 145 to 110 L.P.M With outlet dia 25 mm (keeping 100% standby) |
| 312 | DOL Control panel |
| 313 | 40mm dia steel short piece |
| 314 | Well cap |
| 315 | 50mm size CI bracket |
| 316 | 2.50sqmm flat cable |
| 317 | 20mm dia rigid UPVC pipes |
| 318 | Torchain rope with cover 5 mm ARK |
| 319 | Labour charges for lowering including transportation |
| 320 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor HDPE pipes and pipe fittings conforming to IS: 4984/2000 (10kgf/sqcm) of the following nominal bore with clamps and jointing by Fusion welding method including testing, making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge |
| 321 | 32mm HDPE pipes (Finolex/Supreme make) wih 10 kg/cm2 Please Enable Macros to View BoQ information |