Indian Tenders

Tender Notice

TDR 54799876
Tendering Authority Rural Development Department
Tender No CD/DMN/VVP/NIT/2025 -26 /II
Tender ID 2026_DRDAP_3296_1
Tender Brief Corrigendum : Tender For Construction of Community Hall Under Vvp In Respect Of Cd-Block Damin
City Damin
State Arunachal Pradesh
Document Fees INR 5000 /-
EMD INR 265950.0 /-
Tender Value Refer document
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Construction of Community Hall Under Vvp In Respect Of Cd-Block Damin

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 30-03-2026 Corrigendum2 Date 31-03-2026
2 26-03-2026 Corrigendum2 Technical Bid 30-03-2026
3 26-03-2026 Corrigendum2 Technical Bid 31-03-2026

Key Dates

Publish Date 26-03-2026
Last Date of Bid Submission 30-03-2026

Contact Information

Company Name Rural Development Department
Contact Person Block Development Officer
Address O/o BDO, CD Block Damin, RD, Damin.

BOQ Items

Name of Work:- C/o Community Hall under VVP in respect of CD-Block Damin
Sl. No. Item Description
1SH-1: Community Hall at Rowiok:-
2Earth work in excavation over area i/c disposal of excavated earth lead up to 50m and lift up to 1.5m and disposed soil to be levelled and neatly. a) Hard Soil - 40 %
3b) Hard Soil - 60 %
4Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m.
5Providing and laying in foundations and plinth cement concrete 1 : 5 : 10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
6Reinforcement of RCC work including bending, binding and placing in position complete.a) Mild steel.
7Centring and shuttering including strutting proping etc. and removal of form work for: a) Foundations and plinth.
8c) Columns, pillars and piers.
9d) Lintels, beams, girders, bressumers and cantilevers etc.
10Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in :a) Foundations and plinth
11Reinforcement cement concrete work in columns, pillars,post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
12Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.
13Reinforced cement concrete in chajjas exceeding 15mm in thickness upto floor two level including centring and shuttering complete but xcluding the cost of reinforcement with M20( 1 cement: 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
14Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1cement : 4 fine sand).
15Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth.
16Extra for half brick masonry in superstructure above plinth level and up to floor two level.
17Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position.
18Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal size).
19Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete.
20Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
21Providing corrugated G.I.sheet roofing fixed with galvanised iron J or L hooks, bolts & nuts 8 mm dia with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete, excluding the cost of purlins, rafters and trusses.
22Providing ridges or hips 60 cm overall in plain G.I. sheet fixed with galvanised iron J or L hooks, bolts and nuts 8 mm dia. G.I. limpet and umen washers complete. (b) 0.63 mm thick GI sheet
23Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed olts and nuts or by screws. (b) Ornamental grill.
24Providing and laying in foundations and plinth cement concrete 1 : 5 : 10 (1 cement : coarse sand : 10 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
25Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and lerestory windows including aluminium butt nges with necessary screws.a) 38mm thick best available local wood class - B I
2615 mm cement plaster 1 : 4 (1 cement : 4 fine sand) on the rough side of single or half brick wall.
2712 mm cement plaster 1 : 4 (1 cement : 4 fine sand).
286 mm cement plaster to ceiling 1 : 3 (1 cement : 3 fine sand).
29Providing best available local wood (Class - B II) work in frames of false ceiling, partitions and trusses etc, sawn and put up in position.
30Providing and fixing 4.0 mm thick asbestors plain sheet ceiling of approved quality with necessary nails etc.complete (frame work for base to be paid separately).
31Providing and fixing plain, square edged wooden beading 38 mm x 12 mm section with screws of approved quality for ceiling.
32Extra for making chamfered edges of beading.
33Painting two coats with oil type wood preservative of approved brand and manufacture on new work.
34Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete.
35Applying priming coat with ready mixed primer of approved brand and manufacture on steel work.
36Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade.
37Applying one coat of cement primer of approved brand and manufacture on wall surface.
38Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement. b) 50 mm thick
39Making plinth protection with 2nd class bricks on edge in cement mortar 1 : 6 (1 cement : 6 fine sand) over 7.50 cm bed of dry bricks aggregate 40 mm nominal size rammed consolidated and grouted with fine sand and the top of bricks pointed with cement mortar 1 : 2 (1 cement : 2 fine sand).
40Construction of cement concrete drain 15 cm wide and 15 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips or aggrigate 40 mm and down gauge) 8 cm thick on sides and bottom and plastering and all exposed surfaces with 12 mm thick cement mortar 1 : 3 (1 cement : 3 coarse sand) including shuttering complete.
41Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade.
42Providing and fixing 2.50 cm thick approved local wood eaves boards 23 cm wide with necessary mouldings etc.
43SEPTIC TANK:- Earthwork in excavation in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) including banking in 20 cm layer and breaking clods, ramming and dressing up for the purpose of making embankments or filling up ground depressions, lead upto 30 m and lift upto 1.50 m.
44Extra for every additional lift of 1.50 m or part thereof for earthwork in all soils including shingles, small size boulders upto 30 cm size but excluding saturated soil and rock.
45Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in : a) Foundations and plinth
46Reinforced cement concrete in retaining wall (any thickness) including attached pillasters, buttresses, plinth and string courses, fillets etc from top of foundation up to floor two level excluding cost of centring,shuttering and reinforcement in : b) 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size).
47Centring and shuttering including strutting, propping etc and removal of form work for : b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
48c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).
49Reinforcement of RCC work including bending, binding and placing in position complete. b) Cold twisted bars.
50Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size).
5112 mm cement plaster 1:3 (1 cement : 3 fine sand).
52Neat cement punning
53Providing and fixing of 75 mm S.C.I/CI vent pipe in position as per direction of Engineer-in-Charge.
54Providing and fixing of 75 mm Cowl (C.I.) in position as per direction of Engineer-in-Charge.
55Providing and fixing of 100 mm S.W./C.I. Tee in position as per direction of Engineer-in-Charge.
56Providing and laying jointly glazed stone ware pipe grade 'A' with stiff mixture of cement mortar 1:1 (1 cement : 1 fine sand) i/c testing of joints etc. complete. a) 100 mm dia S.W.pipes
57Providing and fixing C.I. cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) as per direction of Engineer in charge.
58Carriage of Building Materials from Banderdewa to Damin (376 Km)
59Carriages of Sand, Aggregate etc from river beds to worksite
60SH-2: Community Hall at Senamriang:-
61Earth work in excavation over area i/c disposal of excavated earth lead up to 50m and lift up to 1.5m and disposed soil to be levelled and neatly. a) Hard Soil - 40 %
62b) Hard Soil - 60 %
63Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m.
64Providing and laying in foundations and plinth cement concrete 1 : 5 : 10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
65Reinforcement of RCC work including bending, binding and placing in position complete.a) Mild steel.
66Centring and shuttering including strutting proping etc. and removal of form work for: a) Foundations and plinth.
67c) Columns, pillars and piers.
68d) Lintels, beams, girders, bressumers and cantilevers etc.
69Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in :a) Foundations and plinth
70Reinforcement cement concrete work in columns, pillars,post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
71Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.
72Reinforced cement concrete in chajjas exceeding 15mm in thickness upto floor two level including centring and shuttering complete but xcluding the cost of reinforcement with M20( 1 cement: 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
73Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1cement : 4 fine sand).
74Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth.
75Extra for half brick masonry in superstructure above plinth level and up to floor two level.
76Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position.
77Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal size).
78Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete
79Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
80Providing corrugated G.I.sheet roofing fixed with galvanised iron J or L hooks, bolts & nuts 8 mm dia with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete, excluding the cost of purlins, rafters and trusses.
81Providing ridges or hips 60 cm overall in plain G.I. sheet fixed with galvanised iron J or L hooks, bolts and nuts 8 mm dia. G.I. limpet and umen washers complete. (b) 0.63 mm thick GI sheet
82Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed olts and nuts or by screws. (b) Ornamental grill.
83Providing and laying in foundations and plinth cement concrete 1 : 5 : 10 (1 cement : coarse sand : 10 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
84Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and lerestory windows including aluminium butt nges with necessary screws.a) 38mm thick best available local wood class - B I
8515 mm cement plaster 1 : 4 (1 cement : 4 fine sand) on the rough side of single or half brick wall.
8612 mm cement plaster 1 : 4 (1 cement : 4 fine sand).
876 mm cement plaster to ceiling 1 : 3 (1 cement : 3 fine sand).
88Providing best available local wood (Class - B II) work in frames of false ceiling, partitions and trusses etc, sawn and put up in position.
89Providing and fixing 4.0 mm thick asbestors plain sheet ceiling of approved quality with necessary nails etc.complete (frame work for base to be paid separately).
90Providing and fixing plain, square edged wooden beading 38 mm x 12 mm section with screws of approved quality for ceiling.
91Extra for making chamfered edges of beading.
92Painting two coats with oil type wood preservative of approved brand and manufacture on new work.
93Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete.
94Applying priming coat with ready mixed primer of approved brand and manufacture on steel work.
95Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade.
96Applying one coat of cement primer of approved brand and manufacture on wall surface.
97Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement. b) 50 mm thick
98Making plinth protection with 2nd class bricks on edge in cement mortar 1 : 6 (1 cement : 6 fine sand) over 7.50 cm bed of dry bricks aggregate 40 mm nominal size rammed consolidated and grouted with fine sand and the top of bricks pointed with cement mortar 1 : 2 (1 cement : 2 fine sand).
99Construction of cement concrete drain 15 cm wide and 15 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips or aggrigate 40 mm and down gauge) 8 cm thick on sides and bottom and plastering and all exposed surfaces with 12 mm thick cement mortar 1 : 3 (1 cement : 3 coarse sand) including shuttering complete.
100Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade.
101Providing and fixing 2.50 cm thick approved local wood eaves boards 23 cm wide with necessary mouldings etc.
102Septic Tanks:- Earthwork in excavation in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) including banking in 20 cm layer and breaking clods, ramming and dressing up for the purpose of making embankments or filling up ground depressions, lead upto 30 m and lift upto 1.50 m.
103Extra for every additional lift of 1.50 m or part thereof for earthwork in all soils including shingles, small size boulders upto 30 cm size but excluding saturated soil and rock.
104Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in : a) Foundations and plinth
105Reinforced cement concrete in retaining wall (any thickness) including attached pillasters, buttresses, plinth and string courses, fillets etc from top of foundation up to floor two level excluding cost of centring,shuttering and reinforcement in : b) 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size).
106Centring and shuttering including strutting, propping etc and removal of form work for : b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
107c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).
108Reinforcement of RCC work including bending, binding and placing in position complete. b) Cold twisted bars.
109Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size).
11012 mm cement plaster 1:3 (1 cement : 3 fine sand).
111Neat cement punning
112Providing and fixing of 75 mm S.C.I/CI vent pipe in position as per direction of Engineer-in-Charge.
113Providing and fixing of 75 mm Cowl (C.I.) in position as per direction of Engineer-in-Charge.
114Providing and fixing of 100 mm S.W./C.I. Tee in position as per direction of Engineer-in-Charge.
115Providing and laying jointly glazed stone ware pipe grade 'A' with stiff mixture of cement mortar 1:1 (1 cement : 1 fine sand) i/c testing of joints etc. complete. a) 100 mm dia S.W.pipes
116Providing and fixing C.I. cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) as per direction of Engineer in charge.
117CARRIAGE:- Cost of Cements, Steel & CGI Sheet. (Itanagar to Site) 372 Km
118Carriages of Sand, Aggregate etc from river beds to worksite
119SH-3: Community Hall at Sibia:-
120Earth work in excavation over area i/c disposal of excavated earth lead up to 50m and lift up to 1.5m and disposed soil to be levelled and neatly. a) Hard Soil - 40 %
121b) Hard Soil - 60 %
122Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m.
123Providing and laying in foundations and plinth cement concrete 1 : 5 : 10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
124Reinforcement of RCC work including bending, binding and placing in position complete.a) Mild steel.
125Centring and shuttering including strutting proping etc. and removal of form work for: a) Foundations and plinth.
126c) Columns, pillars and piers.
127d) Lintels, beams, girders, bressumers and cantilevers etc.
128Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in :a) Foundations and plinth
129Reinforcement cement concrete work in columns, pillars,post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
130Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.
131Reinforced cement concrete in chajjas exceeding 15mm in thickness upto floor two level including centring and shuttering complete but xcluding the cost of reinforcement with M20( 1 cement: 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
132Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1cement : 4 fine sand).
133Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth.
134Extra for half brick masonry in superstructure above plinth level and up to floor two level.
135Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position.
136Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal size).
137Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete
138Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
139Providing corrugated G.I.sheet roofing fixed with galvanised iron J or L hooks, bolts & nuts 8 mm dia with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete, excluding the cost of purlins, rafters and trusses.
140Providing ridges or hips 60 cm overall in plain G.I. sheet fixed with galvanised iron J or L hooks, bolts and nuts 8 mm dia. G.I. limpet and umen washers complete. (b) 0.63 mm thick GI sheet
141Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed olts and nuts or by screws. (b) Ornamental grill.
142Providing and laying in foundations and plinth cement concrete 1 : 5 : 10 (1 cement : coarse sand : 10 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
143Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and lerestory windows including aluminium butt nges with necessary screws.a) 38mm thick best available local wood class - B I
14415 mm cement plaster 1 : 4 (1 cement : 4 fine sand) on the rough side of single or half brick wall.
14512 mm cement plaster 1 : 4 (1 cement : 4 fine sand).
1466 mm cement plaster to ceiling 1 : 3 (1 cement : 3 fine sand).
147Providing best available local wood (Class - B II) work in frames of false ceiling, partitions and trusses etc, sawn and put up in position.
148Providing and fixing 4.0 mm thick asbestors plain sheet ceiling of approved quality with necessary nails etc.complete (frame work for base to be paid separately).
149Providing and fixing plain, square edged wooden beading 38 mm x 12 mm section with screws of approved quality for ceiling.
150Extra for making chamfered edges of beading.
151Painting two coats with oil type wood preservative of approved brand and manufacture on new work.
152Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete.
153Applying priming coat with ready mixed primer of approved brand and manufacture on steel work.
154Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade.
155Applying one coat of cement primer of approved brand and manufacture on wall surface.
156Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement. b) 50 mm thick
157Making plinth protection with 2nd class bricks on edge in cement mortar 1 : 6 (1 cement : 6 fine sand) over 7.50 cm bed of dry bricks aggregate 40 mm nominal size rammed consolidated and grouted with fine sand and the top of bricks pointed with cement mortar 1 : 2 (1 cement : 2 fine sand).
158Construction of cement concrete drain 15 cm wide and 15 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips or aggrigate 40 mm and down gauge) 8 cm thick on sides and bottom and plastering and all exposed surfaces with 12 mm thick cement mortar 1 : 3 (1 cement : 3 coarse sand) including shuttering complete.
159Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade.
160Providing and fixing 2.50 cm thick approved local wood eaves boards 23 cm wide with necessary mouldings etc.
161Septic Tanks:- Earthwork in excavation in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) including banking in 20 cm layer and breaking clods, ramming and dressing up for the purpose of making embankments or filling up ground depressions, lead upto 30 m and lift upto 1.50 m.
162Extra for every additional lift of 1.50 m or part thereof for earthwork in all soils including shingles, small size boulders upto 30 cm size but excluding saturated soil and rock.
163Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in : a) Foundations and plinth
164Reinforced cement concrete in retaining wall (any thickness) including attached pillasters, buttresses, plinth and string courses, fillets etc from top of foundation up to floor two level excluding cost of centring,shuttering and reinforcement in : b) 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size).
165Centring and shuttering including strutting, propping etc and removal of form work for : b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
166c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).
167Reinforcement of RCC work including bending, binding and placing in position complete. b) Cold twisted bars.
168Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size).
16912 mm cement plaster 1:3 (1 cement : 3 fine sand).
170Neat cement punning
171Providing and fixing of 75 mm S.C.I/CI vent pipe in position as per direction of Engineer-in-Charge.
172Providing and fixing of 75 mm Cowl (C.I.) in position as per direction of Engineer-in-Charge.
173Providing and fixing of 100 mm S.W./C.I. Tee in position as per direction of Engineer-in-Charge.
174Providing and laying jointly glazed stone ware pipe grade 'A' with stiff mixture of cement mortar 1:1 (1 cement : 1 fine sand) i/c testing of joints etc. complete. a) 100 mm dia S.W.pipes
175Providing and fixing C.I. cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) as per direction of Engineer in charge.
176Carriage of Building Materials from Banderdewa to Damin (376 Km)
177Carriages of Sand, Aggregate etc from river beds to worksite
178SH-4: Community Hall at Katuk:-
179Earth work in excavation over area i/c disposal of excavated earth lead up to 50m and lift up to 1.5m and disposed soil to be levelled and neatly. a) Hard Soil - 40 %
180b) Hard Soil - 60 %
181Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m.
182Providing and laying in foundations and plinth cement concrete 1 : 5 : 10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
183Reinforcement of RCC work including bending, binding and placing in position complete.a) Mild steel.
184Centring and shuttering including strutting proping etc. and removal of form work for: a) Foundations and plinth.
185c) Columns, pillars and piers.
186d) Lintels, beams, girders, bressumers and cantilevers etc.
187Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in :a) Foundations and plinth
188Reinforcement cement concrete work in columns, pillars,post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
189Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.
190Reinforced cement concrete in chajjas exceeding 15mm in thickness upto floor two level including centring and shuttering complete but xcluding the cost of reinforcement with M20( 1 cement: 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
191Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1cement : 4 fine sand).
192Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth.
193Extra for half brick masonry in superstructure above plinth level and up to floor two level.
194Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position.
195Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal size).
196Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete
197Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
198Providing corrugated G.I.sheet roofing fixed with galvanised iron J or L hooks, bolts & nuts 8 mm dia with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete, excluding the cost of purlins, rafters and trusses.
199Providing ridges or hips 60 cm overall in plain G.I. sheet fixed with galvanised iron J or L hooks, bolts and nuts 8 mm dia. G.I. limpet and umen washers complete. (b) 0.63 mm thick GI sheet
200Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed olts and nuts or by screws. (b) Ornamental grill.
201Providing and laying in foundations and plinth cement concrete 1 : 5 : 10 (1 cement : coarse sand : 10 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
202Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and lerestory windows including aluminium butt nges with necessary screws.a) 38mm thick best available local wood class - B I
20315 mm cement plaster 1 : 4 (1 cement : 4 fine sand) on the rough side of single or half brick wall.
20412 mm cement plaster 1 : 4 (1 cement : 4 fine sand).
2056 mm cement plaster to ceiling 1 : 3 (1 cement : 3 fine sand).
206Providing best available local wood (Class - B II) work in frames of false ceiling, partitions and trusses etc, sawn and put up in position.
207Providing and fixing 4.0 mm thick asbestors plain sheet ceiling of approved quality with necessary nails etc.complete (frame work for base to be paid separately).
208Providing and fixing plain, square edged wooden beading 38 mm x 12 mm section with screws of approved quality for ceiling.
209Extra for making chamfered edges of beading.
210Painting two coats with oil type wood preservative of approved brand and manufacture on new work.
211Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete.
212Applying priming coat with ready mixed primer of approved brand and manufacture on steel work.
213Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade.
214Applying one coat of cement primer of approved brand and manufacture on wall surface.
215Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement. b) 50 mm thick
216Making plinth protection with 2nd class bricks on edge in cement mortar 1 : 6 (1 cement : 6 fine sand) over 7.50 cm bed of dry bricks aggregate 40 mm nominal size rammed consolidated and grouted with fine sand and the top of bricks pointed with cement mortar 1 : 2 (1 cement : 2 fine sand).
217Construction of cement concrete drain 15 cm wide and 15 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips or aggrigate 40 mm and down gauge) 8 cm thick on sides and bottom and plastering and all exposed surfaces with 12 mm thick cement mortar 1 : 3 (1 cement : 3 coarse sand) including shuttering complete.
218Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade.
219Providing and fixing 2.50 cm thick approved local wood eaves boards 23 cm wide with necessary mouldings etc.
220Septic Tanks:- Earthwork in excavation in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) including banking in 20 cm layer and breaking clods, ramming and dressing up for the purpose of making embankments or filling up ground depressions, lead upto 30 m and lift upto 1.50 m.
221Extra for every additional lift of 1.50 m or part thereof for earthwork in all soils including shingles, small size boulders upto 30 cm size but excluding saturated soil and rock.
222Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in : a) Foundations and plinth
223Reinforced cement concrete in retaining wall (any thickness) including attached pillasters, buttresses, plinth and string courses, fillets etc from top of foundation up to floor two level excluding cost of centring,shuttering and reinforcement in : b) 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size).
224Centring and shuttering including strutting, propping etc and removal of form work for : b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
225c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).
226Reinforcement of RCC work including bending, binding and placing in position complete. b) Cold twisted bars.
227Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size).
22812 mm cement plaster 1:3 (1 cement : 3 fine sand).
229Neat cement punning
230Providing and fixing of 75 mm S.C.I/CI vent pipe in position as per direction of Engineer-in-Charge.
231Providing and fixing of 75 mm Cowl (C.I.) in position as per direction of Engineer-in-Charge.
232Providing and fixing of 100 mm S.W./C.I. Tee in position as per direction of Engineer-in-Charge.
233Providing and laying jointly glazed stone ware pipe grade 'A' with stiff mixture of cement mortar 1:1 (1 cement : 1 fine sand) i/c testing of joints etc. complete. a) 100 mm dia S.W.pipes
234Providing and fixing C.I. cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) as per direction of Engineer in charge.
235Carriage of Building Materials from Banderdewa to Damin (376 Km)
236Carriages of Sand, Aggregate etc from river beds to worksite Please Enable Macros to View BoQ information

Other Detail

Information Source https://arunachaltenders.gov.in
Download FileName File Description File Size
Download Tender_Documents.pdf Tender Documents 0 KB
Download BOQ_3491.xls Tender Documents 0 KB
Download f3901461-6580-4cbf-9a6c-bbff2af14623.html Tender Documents 0 KB
Download Tendernotice_1 (2).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.