Indian Tenders

Tender Notice

TDR 54798286
Tendering Authority Road And Building Department
Tender No CCENC (R AND B) /23/ 2025-26
Tender ID 2026_EICCL_127541_12
Tender Brief Tender For Construction Of 01 No Of C Type Quarter For Civil Judge (Sr. Division) At Rairakhol.
City Rairakhol
State Odisha
Document Fees INR 10000 /-
EMD INR 115600.0 /-
Tender Value INR 1.15 Crore /-
Tender Type Tender
Bidding Type National Competitive Bid
Competition Type Indian

Tender Details

Tender for Construction Of 01 No Of C Type Quarter For Civil Judge (Sr. Division) At Rairakhol.

Key Dates

Publish Date 24-03-2026
Last Date of Bid Submission 08-04-2026
Tender Opening Date 09-04-2026

Contact Information

Company Name Road And Building Department
Contact Person C.C.E, Northern R AND B Circle, SAMBALPUR
Address O/O THE C.C.E, Northern R AND B Circle, SAMBALPUR

BOQ Items

Name of Work:- Construction of 01 no of C type Quarter for Civil Judge (Sr. Division) at Rairakhol.
Sl. No. Item Description
1Earth work in hard soil or gravelly soil within 50m. Initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm laying in layers not exceeding 0.3m in depth and as per the direction of the Engineer-in-charge and as per direction of the Engineer-in-charge
2Providing Antitermite treatments as per ISI specification including making holes 3'0\\" C/C both ways injecting chemical with water in propertion(1:20) or any approved propertion by the EIC & treatment to choukath sides & wall junction. Cost & conveyance of all materials, labours, T&P etc complete. as per direction of EIC.
3Sand filling in foundation and plinth including cost of all material, labour, conveyance, loading and unloading, taxes, royalties, sundries, tools and plants etc. complete as per the driection of the Engineer in Charge. (linear measurement will be taken and quantity will be calculated on standard weight for all heights).
4Filling area with excavated earth materials including labour, conveyance, loading and unloading, taxes, royalties, sundries, tools and plants etc. complete as per the driection of the Engineer in Charge.
5Providing and laying of 80mm thick factory made cement concrete interlocking paver block of M35 grade and approved make variety colour and size made by Block making machin with strong vibratory compaction of approved design and shape, laid in required col
6Providing and lying plain cement concrete of proportion (1:3:6) in foundation and floors using Portland slag cement (PSC) with 40 mm. Size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm thick in each layer including cost, conveyance, loading, unloading, royalties and taxes all materials and cost all labours, sundries, T & P required for the work including shoring, shuttering and dewatering if required including hire & running charges of water pump complete as per the instruction of the Engineer-in-Charge.
7Providing, lifting, hoisting and laying Reinforced cement concrete of M-20 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position.
8(a)Base Footing
9(b) Column in s/s
10i)Ground Floor
11II)First Floor
12iii)Head Room
13(c) Plinth beam
14(d) Lintel band
15i)Ground Floor
16II)First Floor
17(e) Chajja( at lintel level & window sill level )
18i)Ground Floor
19II)First Floor
20g) Shelves
21i)Ground Floor
22II)First Floor
23(f) Stair case
24i)Ground Floor
25(g) Roof Beam
26i)Ground Floor
27II)First Floor
28i)Ground Floor
29II)First Floor
30II)First Floor(Double Stageing)
31Straightening bent up or coiled M.S. rod or HYSD steel (Fe-415 / Fe-500), cutting, bending, cranking, hooking, welding or jointing (if required), the M.S. rod or HYSD steel and binding, tying the grills, hoisting, lowering and placing in proper position as per drawing & design required for R.C.C. works including cost, conveyance and taxes of M.S. rod or HYSD steel and binding wires of 18 to 20 gauge and labour with all T&P required for the work etc. complete as per approved drawing and technical specification and as per clause-1600 of MoSRTH specification for road & bridge works (Latest Revision ) complete in all respect as directed by Engineer-in-Charge.(weight of binding wires will not be considered for payment and payment will be made on weight of M.S. rod or HYSD steel only. Steel bars of only MAJOR INTEGRATED STEEL PLANTS like SAIL, RINL, TATA, JINDAL & SHYAM STEEL, etc. of Fe-415 / Fe-500 grade are to be used in the work & if required original bill of . steel has to be produced by the contractor)
32i)Ground Floor
33II)First Floor
34iii)Head Room
35First class Fly ash Brick masonry using bricks of size 23 cm. x 11 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix (1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge.
36First class Fly ash Brick masonry using bricks of size 23 cm. x 11 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Super stracture including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge.
37i)Ground Floor
38II)First Floor
39iii)Head Room
40First class Fly ash Brick masonry using Fly Ash. bricks of size 23 cm. x 11 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix (1:4) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Superstructure including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge.
41i)Ground Floor
42II)First Floor
43Supplying of M.S. Grill made out of structural steel, flats, plates, bars confirming to IS for windows, ventilators etc. as per drawing and design, fixed to walls with clamps including priming 1 coat with all kdamages in walls and floors etc. including cost of all materials, labour, conveyance, taxes, royalties, scaffolding, watering, curing, sundries, tools and plants etc.as per the direction of the Engineer in Charge.
44Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately) Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made : Frame size- 65*125 mm(DAR Cl. 26.86.6)
45Providing and fitting, fixing of 32 mm thick flush door shutters conforming to IS 2002 (Part-1) decorative type, core block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both face of shutters inclussive of 4 nos of stainless steel Butt Hinges (100mm x 60mm x 2.5mm) 40mm stainless steel screws. Cylindrical Look(Godrej-9843), Tower Bolts SS 10mm X 300mm (Bathroom)(Godrej 3264), PVC Door Buffer with SS Screw, teak wood lipping around the edges & paste with 1.5mm thick lam8inate on both side of the flush door, etc., including the cost of all materials, hardware fittings, cost of all labour, convence, loading, unloading, T&P, etc , complete as per the direction of Engineer-in charge.
46Supplying fitting fixing of Un-plasticcide Poly Vinyl Chloride(UPVC) (FENESTA/NCL VEKA LTD.) Three Track-Three Panel slidind window-60 Series duly Manufactured using UPVC reinforced profiles of 108mm x 45mm x 2.5mm for outer frames and window sash of 39mm x 58mm 2.5mm capable of mounting single galazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5mm perfabricated & welded through fusion welding the window frame shall be with 6mm thick clear thougherned glass of SAINT-GOBAIN make duly fixed with EPDM weathering seal resistance and the system is to be installed using Reinforced Large Coupler at the site using anchor fasteners, silicon rubber sealant, easy glazing/deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges, materials and product conforming to ASTMD 638-14, EN-477-95 and other applicable codes and standards.
47Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.
48Providing 6 mm thick cement plaster in cm (1:4) to RCC surfaces finished smooth including closed deep chipping and slurry treatment including cost of all materials, labour, conveyance, loading and unloading, taxes, royalties, sundries, tols and plants etc. complete as per the driection of the Engineer in Charge.
49i)Ground Floor
50II)First Floor
51iii)Head Room
52Providing 12mm thick cement plaster in cm (1:6) on the rough surface/ plumbed surface of masonry racking out of joints, scrapping and cleaning the surface and finishing the plastered surface smooth to proper plumbs and level and providing grooves as shown in the drawning including cost of all material, labour, conveyance, loading and unloading, taxes, royalties, sundries, tools and plants etc. complete as per the driection of the Engineer in Charge.
53i)Ground Floor
54II)First Floor
55iii)Head Room
56Providing 16mm thick cement plaster in cm (1:6) on the rough surface of masonry walls for all floors including racking and joints, scrapping and cleaning the surface and finishing the plastered surface smooth to proper plumbs and level and providing grooves as shown in the drawning including cost of all material, labour, conveyance, loading and unloading, taxes, royalties, sundries, tools and plants etc. complete as per the driection of the Engineer in Charge.
57i)Ground Floor
58II)First Floor
59Providing 12mm thick cement plaster in cm (1:4) on the rough surface/ plumbed surface of masonry racking out of joints, scrapping and cleaning the surface and finishing the plastered surface smooth to proper plumbs and level and providing grooves as shown in the drawning including cost of all material, labour, conveyance, loading and unloading, taxes, royalties, sundries, tools and plants etc. complete as per the driection of the Engineer in Charge.
60i)Ground Floor
61II)First Floor
62Supplying, fitting & fixing of Granite Tiles of minimum Above 0.40 sqm. (20mm thick) of approved make in floors laid on 20 mm thick cement mortar (1:4)(1 cement : 4 course sand) and filling joints with slurry for kitchen platforms, vanity counters, facias and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge, making gas pipe hole etc. including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights. In all floors and all heights.
63Supplying & fixing of industrial vitrified tiles on 20 mm thick bed of cement mortar (1:4) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights. In all floors and all heights.
64Supplying, Fitting & Fixing of full body Vitrified Tile (SUPER PREMIUM QUALITY) on floors of size 600mm x 1200mm x 10 mm with self-embossed grooves, Bull nose finished, antiskid properly laid on 20 MM THICK cement mortar ( I :4) and Spacer Bar of 3mm and filling joints with epoxy grout of approved quality including cost of all materials, labour T & P etc required for the works all complete. The surface quality must have free from visible defects(IS-13630-1 ), class-I stain resistance, no expansion on moisture, acid & alkali resistace, resistance to house hold chemicals, thermal shock resistance, less than 0.08% water resistance, frost free, coefficient of friction greater than 0.34. Make: (JOHNSON I SOMA NY I KAJARJA I NITCO)Tile Epoxy Grout make: ASIAN PAINTS(code9660)/ BERGER(HS Tile grout)/ DULUX (epoxy grout)
65i)Ground Floor
66II)First Floor
67Supplying, fitting and fixing vitrified tile in floors of size 600mm x 600mm coloured / printed series of approved make of premium grade having thickness 8mm to 10mm conforming to IS-13756 on 20mm thick bed of cement mortar (1:4) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties and taxes of all materials complete in all respects.
68Supplying, Fitting & Fixing of full body Vitrified Tile (SUPER PREMIUM QUALITY) on Dados of size 600mm x 1200mm x JO mm with self-embossed grooves, Bull nose finished, antiskid properly laid on 12 MM THICK cement mortar (I :3) and Spacer Bar of 3mm and filling joints with epoxy grout of approved qualityincluding cost of all materials, labour T & P etc required for theworks all complete. The surface quality must have free from visibledef ects(IS-13630-1 ), class- I stain resistance, no expansion onmoisture, acid & alkali resistace,resistance to house holdchemicals, thermal shock resistance, less than 0.08% waterresistance, frost free, coefficient of friction greater than 0.34. Make:(JOHNSON I SO MANY I KAJARIA I NITCO)Tile Epoxy Groutmake: ASIAN PAINTS(code9660)/ BERGER(HS Tile grout)/DULUX (epoxy grout)
69i)Ground Floor
70II)First Floor
71Supplying, fitting and fixing vitrified wall tiles having dimension 600mm x 600mm coloured / printed series of approved make of premium grade having thickness 8mm to 10mm conforming to IS-13756 as directed by Engineer-in-charge in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties and taxes of all materials complete in all respects
72Providing fitting fixing of false ceiling with Aluminium anodised T section No.3215 with 2'0\\" center to center, L section No.1705 on 4 walls to be fixed by means of steel screw and P.V.C. plug and the Aluminium grid 2'0\\"x2'0\\" with12.5 mm thick Gypsum board suspended from ceiling including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-charge
73II)First Floor
74Supplying fitting fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balstrade of size 32mmx32mmx2mm @0.90mtr C/C and stainless square pipe bracing of size 32mmx32mmx2mm in 3 rows in stair case as per approved design and specification, buffing, pollishing etc with cost, conveyance taxex of all materials, labour, T&P etc. required for the complete in all respect.
75Finishing wall surface of walls with Acrylic wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials taxes, labour T&P etc complete.
76i)Ground Floor
77II)First Floor
78Preparing surface and painting at all height with two or more coats of interior Plastic Emulsion \\"Royale Shyne\\" of Asian Paints or equivalent of over a coat of primer approved shade as per the instructions of the manufacturers; giving uniform shade etc in all heights of walls etc. including interior wall primer & providing scaffolding, cleaning, curing and supply of all materials and labour complete as per drawing, design and direction of Architect/Engineer-In-Charge.
79i)Ground Floor
80II)First Floor
81Providing and applying to outside walls with two or more coats of Anti-Fungal Weather coat paint over a coat of primer including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-Charge at all elevations including all material labour complete.
82i)Ground Floor
83II)First Floor
84iii)Head Room
85Painting two coats with any approved synthetic enamel paint of approved quality shade and make over a coat of Red Oxide priming to new wood work / iron work including cost of the primer and paint, sand papering polishing the surface with cost, conveyance and taxes of all materials and labour with T&P required for the work etc. complete in all respect.
86i)Ground Floor
87II)First Floor
88Providing and installing two component acrylic modified cementitious water proofing coating with Nerolac Perma Guard 2k/sikatop seal 109 or equvalent with Nerolac perma fibre mesh 45Gsm over roof slab after carring out pond test on roof slab filling all defects,saturating the suface mixing the products and then application in 1mm thickness (1.8 kg/sqm coverage rate for 1mm thickness) in suitable layers complete in all respect all material, tools,plants & labour complete in all respect.Density 1850kg/m3,mix ratio (Powder to liquid) 2:1 by weight water.
892.5cm (1”) av. thick grading concrete (1:2:2) using 6mm size black hard crusher broken granite chips over roof slab after chipping and chiseling the same and cleaning the surface by brushing laid to proper slope finished smooth to receive tarfelt treatment watering and curing including cost, conveyance, royalties and taxes of all materials with all labour and T&P etc. required for the work complete in all respect in all floors.
90II)First Floor
91Supplying,fitting & fixing of rain water spout using 100mm dia PVC pipe as per technical specifications (Including cutting hole in brick massonary & fixing the pipe with CM (1:4) including all cost, conveyance, taxes, cess,royalties of all materials, cost of all labour, T&P required for the work etc. complete as per specification & direction of Engineer-in-charge.
92Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as g
93Providing G.S.B. Gr-VI stone screaning materials, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC and compacting with vibratory roller to achieve the desired density, as per approved Drawing & Technical Specifications and as per Clause - 401 of MoRT&H Specifications for Road & Bridge works (5th Revision) including cost, conveyance, royality & other taxes of materials, cost of labour, machinery, T&P etc complete.
94Supplying and fixing of Pre cast kerb stone of size 600mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984.
95Conveyance of excavated earth materials by mechanical means including 5km lead complete including all labour, materials & royality etc. complete as per direction of EIC.
96Electrical workRecessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor (Make-Havells/Polycab/Finolex/RR Kable ) of ISI marked with 20 mm dia PVC heavy class FRLS non metallic conduit(Make-AKG/Polycab/precision/norpack/sudhakar) with 6A modular type switch(Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) ) ISI marked , and ceiling rose ISI marked of modular type G.I box with cover , of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection .Raw power supply switch board shall be separate from emergency power supply switchboard as per direction of Engineer -in -Charge.Each light point should have provision for ceiling rose & angle holder point.
97GROUP-A
98GROUP-B
99GROUP-C
100Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6Aswitch&socket(modulartype)(Makegrand(Myrius),Schneider(Zencelo),Panasonic(Vision) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge.
101Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)(Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.
102Supplying,fixing of 16A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type) (Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.
103Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6A switch & socket(modular type) ( (anti bactorial & flame retradant type) with suitable size modular box & metallic cover plate (both side)(anti bactorial & falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN)/Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
104Supplying,fixing of 3x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+3 nos 6A switch & socket(modular type) ( (anti bactorial & flame retradant type) with suitable size modular box & metallic cover plate (both side)(anti bactorial & falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ legrand( ( Myrius-NEXT GEN)) /Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
105Supplying and fixing AC point consisting of 16A socket outlet Modular type along with 25A starter with all connections and accessories as required as per direction of Engg.-in-Charge.(Make-Schneider/Siemens/Legrand)
106Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover. as required as per direction of Engg.-in-Charge. (Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision)
107Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (2X1.5+1X1.5)
108Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5)
109Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5)
1102 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic FRLS heavy duty PVC conduit .(PANEL TO BDB EACH QTR) (2X6+1X2.5)
111Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit. (4X6+2X2.5)
112Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 1 nos single core 1.5 sq. mm copper wire for phase in existing conduit (invertor point)
113S/F of Bakelite angle holder/batten holder (make-Anchor/Havells of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .
114Sub-Head II (Light fitting Fixture & Fan)
115Supplying, installation, of exhaust fan of heavy duty 300 mm sweep with louvers any other equivalent reputed make star rated as approved) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement warranty shall be 2 years. Make-Havells/Bajaj/Usha/Crompton /Orient
116S/F. Of 400mm High Speed Wall fans including all connections and accessories of Usha/Orient/Havells/Equivalent make
117Supplying, installation, testing and commssioning of 1200 mm sweep BLDC ceiling fan with aluminium blades having wattage not more than 28W and Air delivery ≥ 215(m3/min) Make-USHA(Technix)/Crompton(Energion Groove)/Havells(Efficiencia Neo ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years .
118S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision)
119Supplying and fixing extra conduit down rod of 40 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .
120SITC of energy efficient LED tube light fittings with decorative alumunium LED batten along with LED tube light having power rating 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser i/c connection etc as required.The luminaire should be Replacement Warranty will be 2 years panasonic/havells/LT/Bajaj/Phillips/Crompton/Wipro
121SITC of Sleek LED 10 watt mirror light fitting with decorative aluminium LED batten having extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.The luminaire should be Replacement Warranty will be 2 yearshavells/Bajaj/Phillips/Crompton/Wipro
122SITC of Sleek LED 15 watt LED Lamp complete with all accessories etc. directly on angle holder as required.The luminaire should be Replacement Warranty will be 2 yearshavells/LT/Bajaj/Phillips/Crompton/Wipro
123Supply and fixing of 10 Watt LED BH Fitting.The luminaire should be Replacement Warranty will be 2 years (havells/Bajaj/Phillips/Crompton/Wipro)
124Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years
125Supply and Installation of 2000 VA, 12 V UPS ISI marked in cluding all connections and accessories.(Make-Luminous/Microtek/Livguard/Equivalent)
126Supply and Installation of 150 AH tall tubular battery ISI marked.(Make-Luminous/Microtek/Livguard/Equivalent)
127Supply and Fixing of Trolley for Double Battery
128S/F of Street light- 45W,120 lm/w efficacy , new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) (5Years Warranty).
129S/F of Street light- 90W,120 lm/w efficacy , new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover(Make: Havells /Philips/Wipro /Crompton/Bajaj) (5Years Warranty).
130BDBS,DB,AC DB,FLOOR PANELS,MCBS
131Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB Itus as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years
1324 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years.
133Supply and fixing of 8 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years.
134Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 Model of ABB/LK/Hager/C&S/Havells/Panasonic. the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year.
135Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, DOUBLE POLE MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 Model in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year.
136Supplying and fixing 63 amps rating, 240 volts, C series,10KA breaking capacity, DOUBLE POLE MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year.
137Supplying and fixing 63 Amps rating, 4P, 415 volts, MCB . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 3 years
138Supplying and fixing 40 Amps rating, 4P, 415 volts, RCCB 30mA . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .(4W TPN BDB IC). The MCB should be Replacement Warranty will be 3 years
139(Earthing) INSTALLATION
140Earthing with G.I earth pipe 3 meter long 40 mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangment and watering pipe etc with charcoal and salt as required.
141Providing and fixing 8 SWG (4 mm) dia copper wire on surface or in recess for loop earthing as required.
142CABLING AND END TERMINATION MAIN AREA
143Supplying of one number PVC insulated armoured and PVC sheathed AL. conductor power cable of 1.1 KV grade of following size cables as per direction of Engg.-in-Charge. make-polycab/finolex/Havells/KEI
1444core x 16 sq mm
145LAYING OF CABLE
146Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
147Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.
148Supplying and making end termination with brass comprecision gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.
1494core x 16 sq mm
150S/F of 63A ICDP Main Switch of Havells/Anchor/HPL/L&T/Equivalent make. Including all coneections and accessories as required.
151PANELS
152MAIN METERING PANEL
153S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit Metering panel) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) BUILDING MAIN)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.3P+N Type 2 SPD 40 kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed..
154Metering-Space for 1 no 10-60A 3PH KWH Meter .
155In commer- 01 number of 63 Amps 4P MCCB Icu=100%Ics,,16KA LSIG MCCB with TMR based releaseMake-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula ) with 63A 4P changeover switch (Make-HPL/LK/Siemens/Schneider).
156Busbar- 04 numbers of 100Amps Electrolytic al. busbar with 1A/SQ.MM current carring capacity.Busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing)
157Out going- (i) 63A 2P MCB rating,10 KA breaking capacity,C series, MCB Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) 2 nos
158Out going- (iii) 32A 2P MCB rating,10 KA breaking capacity,C series, MCB Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) 2 nos
159Instrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse.
160(ii) 01 set of digital type multifunction meter with CT for voltage,current,frequency indication .
161CABLE TRAY
162Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.
163AIR CONDITIONER
164Supply of A,C with indoor and outdoor unit
1651.5 TR high wall 5 star inverter type split A.C machine (BTU/Hr-18000)with copper condensor & evaporator having ambient temperature 52 degree celcius with comprehensive 1 year warranty,5 years warranty on PCB, 5 years warranty on compressor (Make:O-General/Diakin/Mitsubishi/Hitachi/Carrier)
166REFRIGRANT PIPING
167Supply,installation of hard/soft copper refregrant piping of size 5/8 inch and 1/4 inch for suction and liquid line with 3 corex4 sqmm FRLS Copper control cable alongwith 25 mm weather proof closed cell nitrile insulation ,complete with fitting of bends and other nesessary material to complete the job.
1681 TR to 3 TR high wall split A.C
169FRAME WORK
170Supply,installation & fabrication of MS base frame for both indoor and outdoor unit and other nesessary material to complete the job.
1711 TR to 3 TR high wall split A.C
172DRAIN PIPING
173Supply,installation & fabrication of Insulated drain water piping from indoor to nearestdrain point separate to all and other nesessary material to complete the job.
17425mm nom. Dia pipe
175Supply and fixing of 4kVA Voltage stabilizer (Make-V-Guard/Microtek
176P.H WORKSupplying all materials , labour, T&P and fixing rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr width KB brickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 3.40m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips and required steel reinforcement including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxes etc.all complete as per approved drawing , P.H. specification and direction of Engineer-in-charge
1772000 liters capacity PVC water storage tank (3 Layer)(Spreme/Sintex/Finolex)
17832mm dia brass full way valve (Shakti make)
17940mm dia brass full way valve (Shakti make)
18050mm dia BFW Valve (Shakti make)
181supplying all materials, labour, T&P and Cutting holes in brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per direction of Engineer-in-charge.
182Supplying all materials , labour, T&P and Cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proof as per P.H. specification and direction of Engineer-in-charge
183Supplying all materials, labour, T&P and Cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages including watering , curing , cost & conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer-in-charge.
184Supplying the waterproofing material Cementetious base Water proofing Pidifin 2K of Dr.fixit or equivalent water proofing material and appling in two coat over the concrete floor and dado upto 1\\"-6\\" in wall including cleaning,applying and mending as per specification including all labour charges as per direction of Engineer-in-charge.
185Bore Packing (4\\"-8\\")Providing necessary formwork for packing the bore using suitable arrangement (depending upon site conditions). Applying a coat of styrene- butadiene based polymer coating using Latex. Packing the gap using non-shrink cement polymer based grout up to the surface of the bore whilst the Latex is in tacky state seal the Bore with polyurethane Sealant, ,including cost of all material, Labour, T&P etc all complete as per the direction of Engineer in charge. (Latex :- Fosroc -Nitobond SBR/ Myk -AquaArm latex 45/ Sika- Sika Latex power , Polymer based grout::- Fosroc- Renderoc RGL / Myk- Laticrete 3DCP-M30 / Sika- Sika ceram-500TG)
186Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.
187110mm U-PVC SWR Pipe (Ori Plast/Finolex/Supreme Make Type-B)
188110mm U-PVC Nahani Trap(Ori Plast/Finolex/Supreme Make)
189110mm U-PVC door bend(Ori Plast/Finolex/Supreme Make)
190110mm U-PVC Plain bend(Ori Plast/Finolex/Supreme Make)
191110mm U-PVC offset without ear(Ori Plast/Finolex/Supreme Make)
192110mm U-PVC Cowl(Ori Plast/Finolex/Supreme Make)
193110mm U-PVC HR Bend(Ori Plast/Finolex/Supreme Make)
194110mm U-PVC S/Jn door(Ori Plast/Finolex/Supreme Make)
195110mm U-PVC Plain tee(Ori Plast/Finolex/Supreme Make)
196110mm U-PVC D/Jn door(Ori Plast/Finolex/Supreme Make)
197110mm U-PVC Door tee(Ori Plast/Finolex/Supreme Make)
198110mm U-PVC Plain shoe bend(Ori Plast/Finolex/Supreme Make)
199110mm U-PVC Socket(Ori Plast/Finolex/Supreme Make)
200Supplying all materials , labour, T&P and providing and fixing to wall or ceiling and floor GI/PVC pipes conforming to IS: 15778 and G.I pipe fittings of the following nominal bore with clamps including making good the wall,ceiling and floor ,testing all complete as per P.H. specification and direction of Engineer-in-charge
20125mm dia PVC ASTM pipe (sch-80)
20232mm dia PVC ASTM pipe (sch-80)
20340mm dia PVC ASTM pipe (sch-80)
20450mm dia PVC ASTM pipe (sch-80)
205Supply and installation of single lever exposed part kit of highflow Diverter constisting of operating lever, cartridge sleeve, wall flange ( with seal), Button Assembly Sleeve & Button (compatible with ALD-079) ARI-39079NK, ARIA-JAQUAR
206Supply and installation of Concealed Body for single lever high flow Diverter without exposed parts ALD-079
207Supply and installation of Maze Overhead Shower 300X300mm Square Shape Single Flow (Body & Face Plate Stainless Steel) with Rubit Cleaning System (OHS-CHR-1639) JAQUAR MAKE
208Supply and installation of Corner Glass Shelf (with Bracket) ACN-CHR-1173 JAQUAR MAKE
209Supply and installation of 15mm dia CP angle stop cock with wall Flange (QQP-7053PM Jaquar make)
210Supply and installation of Wall Hung Bidet, Size: 420X560X370 mm, QPS-WHT-7153PM, JAQUAR MAKE
211Supply and installation of Single Piece Slim Concealed Cistern Body with Installation Kit & “S-Type” drain pipe connection set for Wall Hung WC (without Flush Control Plate) JCS-WHT-2400S,JAQUAR MAKE
212Supply and installation of Control Flush Plate Aria JCP-CHR-392415,JAQUAR MAKE
213Supply and installation of Two Way Bib Cock with Wall Flange, QQP-CHR-7041PM, JAQUAR MAKE
214Supply and installation of Hand Shower (Health Faucet) with 8mm Dia, 1 Meter Long Flexible Tube & Wall Hook. (ALD-CHR-573) JAQUAR MAKE
215Supply and installation of Table Top Basin, Size: 600x460x195 mm QPS-WHT-7901PM JAQUAR MAKE
216Supply and installation of Flash touch-free infrared Hand dryer with 1150W rated power & carbon brush motor HDR-SSF-AK2807-Jaquar Make
217Supply and installation of Soap Dispenser with Glass Bottle (ACN-CHR-1135N)-Jaquar Make
218Supply and installation of Towel Ring Square (AKP-CHR-35721P) -Jaquar Make
219Supply and installation of Swivel Mirror 630 X 445mm Rectangular Shape (AKP-CHR-35795)-Jaquar Make
220Supply and installation of Double Arm Wall Mounted Reversible Plain/ Magnifying (3X) Pivotal Mirror (ACN-CHR-1193N)-Jaquar Make
221Supply and installation of FLOOR GRATING DRAINER WITH BOWL SIZE 150X150 SS304 GRADE Model 2
222Supplying all materials labour T&P filling sand in lavatories well watered and rammed including lead of materials to work site.
223Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge
224Supplying all materials, labour, T&P and providing and fixing ceramic tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) ( 1 cement : 1 sand ) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge ( ceramic floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of size 40cmx40cm special printed series to be pre-approved by the Engineer-in-charge )
225Kajaria/Somany/NITCO/Johnson (120cm x 60cm)
226Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.
227Supplying all materials, labour, T&P and providing and fixing porcelain glazed tiles in dado skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge( ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of size 25cmx33cm special plain / printed series to be pre-approved by the Engineer-in-charge )
228Kajaria/Somany/NITCO/Johnson (120cm x 60cm)
229Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter.
230Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge
231Ext. S/D Portion
232Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufacture's specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge
233100mm dia P.V.C. pipe
234150mm dia P.V.C. pipe
235Supplying all materials labor T&P and constructing MH chamber of sizes earth work in excavation in all kinds of soil CC(1:1:8) with black granite chips size 46mm brick work with K.B. brick having crossing strength not less than 75 Kg /CM2 to 90 Kg/CM2s in CM(1:6)12mm C.P(1:8) inside MH chamber over benching with cement slush pointing (1:3)outside the MH chamber providing painting MS or CI step iron RCC(roof of slab with CC(1:2:4)with black granite chips size 12mm bending binding tying the grills placing of the reinforcement providing RCC color of required size refilling the cavity around the MH chamber with excavated earth including channeling the bed of MH etc all complete as per PH specification.
236MH size 0.91m x 0.91 m with 0.45 m (18” dia RCC Cover )
237Supplying all materials ,labour ,T&P and constructing Inspection Chamber of inside size 760mmx760mmx460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-charge
238Inside size 76cmx76cmx46cm with 18” dia RCC MH cover
239Supplying all materials labour T&P and constructing 1.40m dia x 2.00 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site.
240Supplying all materials ,labour ,T&P and constructing gully trap chamber of inside size 250mmx250mm with 8cm thick RCC precast cover slab in cement concrete (1:2:4) mix using 12mm size crusher broken HG chips, foundation concrete (1:4:8) using 40mm size crusher broken HG metal on bed and around trap, KB brick work in cement mortar (1:6) in foundation and plinth and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap, 150mmX150mm size CI grating etc.all complete as per drawing, specification and direction of Engineer-in-charge
24130 USERS SEPTIC TANK
242Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge. 1 x 4.70 x 3.30m x 0. 70
243Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge with 1st extra lift of 1.50 m over initial laft. 1 x 4.70 x 2.30m x 0.15 =
244Supplying all labor T&P & filling foundation and plinth with excavated materials well watered & rammed etc. all complete as per direction of EIC.
245Supplying all materials, labor T&P providing CC (1:3:6) with 4 cm HG metal including watering curing lead of all materials to site etc. complete.
246Supplying all labor T&P &Providing C.C. (1:2:4) with 12mm size broken hard granite chips including watering curing & lead of all materials to site etc. all complete.
2471 x 4.70 x 2.30 x 0.10 =
248providing Bloffal wall 1 x 4.20 x 1.10 x 0.05=
249at adosterace 1/3rd 1 x 1.20 x 1.10 x 0.05 =
250Baffle wall 1 x 1.10 x 1.50 x 0.08 =
251Total
252Providing C.C. (1:1½:3) with 12mm size hard granite chips of RCC work including hoisting and laying and curing with lead of all materials to site.
2531 x 4.10 x 1.60 x 0.10=
2541 x 1.10 x 1.50 x 0.08 =
255Total
256Supplying all materials, T&P and providing MS reinforcement for RCC work including cutting, bending, binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauges. 1.013cum x 2,5 x 35.32 =89.44 say Rs-
257Rigid & smooth centering & sheltering for RCC work including falls work & dismantling than after casting including cost of materials in ground floor.
258RCC floor, roof slab chhaja up to 4.430 m height
2591 x 3.60 x 1.10 =
2602(4.10+1.60)x 0.20 =
261Total
262Supplying all materials labour T&P and providing 1st class KB brick work in CM (1:3) in foundation and plinth including watering and curing and lead of materials to site.
2631st footing
2642 x 4.60 x 0.50 x 0.74 =
2652 x 1.10 x 0.50 x 0.74 =
2662nd footing
2672 x 4.40 x 0.40 x 0.74 =
2682 x 1.10 x 0.40 x 0.74 =
2693rd footing
2702 x 4.10 x 0.25 x 0.74 =
2712 x 1.10 x 0.25 x 0.74 =
272Total
273Supplying all materials labour T&P and providing 12mm thick C.P (1:3) including watering curing and conveyance of all materials to site.
2741 x 3.60 x 1.10 =
2752(3.60+1.10) x2.23 =
276Baffle wall 2(1.10+0.10) x 1.50 =
277out side 2 (4.10+1.60)x0.74 =
278Total
279Supplying all materials labour T&P and providing cement punning including watering curing and conveyance of all materials to site.same as plastering
280Supplying all materials labour T&P and fitting and fixing 12mm dia MS/CI step iron including supply of necessary CC(1:2:4) for fixing etc. complete as per PH specification.
281Supplying all materials, labour T&P for providing fitting & fixing 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:2:4) with 12mm size HG chips all complete including watering curing conveyance of all materials to work site payment of royalty all complete as per specification and direction of Engineer in charge.
282Supplying all materials labor T&P filling sand in foundation and plinth with well watered and rammed etc all complete as per direction of Engineer-in-charge.
283Construction of 1nos production wells including scientific source finding through consolidated and unconsolidated rock with down the hammer drilling rig or combination rig with PVC pipe and installation of submersible pump set with all acessories
284Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only
285Drilling of 200mm dia bore
28600 mtr to 30mtr
28730 mtr to 45mtr
288Drilling of 150mm dia bore
28945 mtr to 213
290Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials.
291200mm dia PVC pipe
29200 mtr to 45 mtrs
293Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance with DIN 2999 part-1/DIN-42225 part-II specification length of pipe (laying length) will be 3 mtrs. The pipes shall be supplied with both external and threaded with free socket. The pipe having external thread at one end i.e female and or belled end. The female end having internal thread is to be belled in order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC/Rubber 'O' ring to make the joint water tight colour of the pipe shall be blue. The name of the manufacture along with batch No class of pipe shall be stranded legibly of each pipe length.
294200mm dia PVC (sch-80) pipe
295Supplying all materials, labour, T&P and providing and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m below ground level (as per drawing) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock at the bottom to ensure sanitary sealing (excluding cost of cement which will be supplied directly by the department)
296Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge
297By DTH Rig
298Supplying all materials, equipment, labour & conducting reconnaissance survey, integrated Hydrological and Geophysical (Electrical Resistivity Method) survey & selection of potential source for exploration of Ground Water including selection and recommendation of site for drilling wells in selected locations in any part of Orissa under the following Geological formation:
299Rocky terrain with boulder formation for 300m depth
300Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge (Texmo/Crompton Greaves/Kirloskar make)
3012 H.P. Single phase/ three phase 3 stage head renge of 20 to 35 mtr with discharge capasity 145 to 110 L.P.M With outlet dia 25 mm
302DOL Control panel
30340mm dia steel short piece
304Well cap
30550mm size CI bracket
3062.50sqmm flat cable
307Steel rope with cover
308Labour charges for lowering including transportation
309Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor HDPE pipes and pipe fittings conforming to IS: 4984/2000 (10kgf/sqcm) of the following nominal bore with clamps and jointing by Fusion welding method including testing, making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge
31032mm HDPE pipes (Finolex/Supreme make) Please Enable Macros to View BoQ information

Other Detail

Information Source http://tendersodisha.gov.in/nicgep/app
Download FileName File Description File Size
Download 12CQRRAIR.pdf Tender Documents 0 KB
Download 3f590446-0669-425e-9fd7-fe30dca7f2fc.html Tender Documents 0 KB
Download BOQ_586048.xls Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.