Indian Tenders

Tender Notice

TDR 54798284
Tendering Authority Road And Building Department
Tender No CCENC (R AND B) /23/ 2025-26
Tender ID 2026_EICCL_127541_5
Tender Brief Tender For Construction Of Proposed 01 No C Type Quarter For J.M.F.C At Barkote In The District Of Deogarh
City Deogarh
State Odisha
Document Fees INR 10000 /-
EMD INR 109500.0 /-
Tender Value INR 1.09 Crore /-
Tender Type Tender
Bidding Type National Competitive Bid
Competition Type Indian

Tender Details

Tender for Construction Of Proposed 01 No C Type Quarter For J.M.F.C At Barkote In The District Of Deogarh

Key Dates

Publish Date 24-03-2026
Last Date of Bid Submission 08-04-2026
Tender Opening Date 09-04-2026

Contact Information

Company Name Road And Building Department
Contact Person C.C.E, Northern R AND B Circle, SAMBALPUR
Address O/O THE C.C.E, Northern R AND B Circle, SAMBALPUR

BOQ Items

Name of Work:- Construction of proposed 01 no C Type Quarter for J.M.F.C at Barkote in the District of Deogarh
Sl. No. Item Description
1Providing jungle cutting uprooting buses below 1.00m girth with cost of all labour and T&P required for the work etc. complete.
2Earthwork in excavation of foundation trenches in All kinds of soil including dressing of sides and leveling the bed up to the required depth and depositing the excavated materials away from the work site with all leads and lifts, including shoring, shuttering and dewatering (if required) with cost of labour, hire & running charges of water pumps sundries & T&P required for the work complete as directed by the Engineer-in-charge.
3Ground Floor
4Servant Quarter
5Filling in foundation trenches and plinth, with excavated earth including laying the earth in layers not exceeding 23.5 cm thick ramming & watering with all leads & lifts including cost of all labour,T&P completed as directed by the Engineer-in-charge.
6Ground Floor
7Servant Quarter
8Supplying and filling in foundation trenches and plinth, ditches with sand well watered and rammed in layers not exceeding 23 cm. In depth with all lead and lift including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. (Measurement will be taken on finished compacted section only).
9Ground Floor
10Servant Quarter
11Diluting and injecting chemical emulsion (to be supplied free of cost at site of work) for PRE CONSTRUCTIONAL Anti-termite treatment and creating a continuous chemical barrier under and all-round the column pits, wall trenches, basement excavation, top perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes and conduits etc. complete as per specifications (plinth area of the building at ground floor only shall be measured for payment).(As per proceedings of S.E level committee meeting held on Dt. 29.06.2021 at 7.00P.M. (V.C.)
12Ground Floor
13Servant Quarter
14Providing and lying plain cement concrete of proportion (1:3:6) in foundation and floors using Portland slag cement (PSC) with 40 mm. Size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm thick in each layer including cost, conveyance, loading, unloading, royalties and taxes all materials and cost all labours, sundries, T & P required for the work including shoring, shuttering and dewatering if required including hire & running charges of water pump complete as per the instruction of the Engineer-in-Charge.
15Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position.
16a)Footing
17b)Column up to Pl Lvl :-
18c)Tie/Plinth Beam :-
19d)Column up to roof lvl :-
20e)Lintel :-
21f)Chajja :-
22g)Roof Beam :-
23h)Roof Slab :-
24i)Stair case :-
25First Floor
26a)Column up to roof lvl :-
27b)Lintel :-
28c)Chajja :-
29d)Roof Beam :-
30e)Roof Slab :-
31f)Stair case :-
32Terrace Floor
33a)Column up to roof lvl :-
34b)Lintel :-
35c)Chajja :-
36d)Roof Beam :-
37e)Roof Slab :-
38Servant Quarter
39a)Footing
40b)Column up to Pl Lvl :-
41c)Tie/Plinth Beam :-
42d)Column up to roof lvl :-
43e)Lintel :-
44f)Chajja :-
45g)Roof Beam :-
46h)Roof Slab :-
47Providing, lifting, hoisting and laying Reinforced cement concrete of M-20 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position.
48B/Wall Column Base Footing
49Column in S/S
50Plinth Beam
51Straightening bent up or coiled M.S. rod or HYSD steel (Fe-415 / Fe-500), cutting, bending, cranking, hooking, welding or jointing (if required), the M.S. rod or HYSD steel and binding, tying the grills, hoisting, lowering and placing in proper position as per drawing & design required for R.C.C. works including cost, conveyance and taxes of M.S. rod or HYSD steel and binding wires of 18 to 20 gauge and labour with all T&P required for the work etc. complete as per approved drawing and technical specification and as per clause-1600 of MoSRTH specification for road & bridge works (Latest Revision ) complete in all respect as directed by Engineer-in-Charge.(weight of binding wires will not be considered for payment and payment will be made on weight of M.S. rod or HYSD steel only. Steel bars of only MAJOR INTEGRATED STEEL PLANTS like SAIL, RINL, TATA, JINDAL & SHYAM STEEL, etc. of Fe-415 / Fe-500 grade are to be used in the work & if required original bill of . steel has to be produced by the contractor)
52Ground Floor
53First Floor
54Terrace Floor
55Servant Quarter
56First class Fly ash Brick masonry using bricks of size 23 cm. x 11 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix (1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge.
57Ground Floor
58Servant Quarter
59First class Fly ash Brick masonry using bricks of size 23 cm. x 11 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Super stracture including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge.
60Ground Floor
61First Floor
62Terrace Floor
63Servant Quarter
64First class Fly ash Brick masonry using Fly Ash. bricks of size 23 cm. x 11 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix (1:4) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Superstructure including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge.
65Ground Floor
66First Floor
67Servant Quarter
68Providing 12mm thick cement plaster in all floors at all height with cement mortar of mix (1:6) with Portland slag cement (PSC) and with screened and washed sharp sand for mortar and finished smooth to the rough surface of brick masonry walls after racking out joints including watering and curing rounding of corners etc. complete with cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, T&P, sundries and scaffolding required for the work etc. with providing grooves as per specification and direction of Engineer-in-charge.
69Ground Floor
70First Floor
71Terrace Floor
72Servant Quarter
73Providing 16mm thick cement plaster in all floors at all height with cement mortar of mix (1:6) with Portland slag cement (PSC) and with screened and washed sharp sand for mortar and finished smooth to the rough surface of brick masonry walls after racking out joints including watering and curing rounding of corners etc. complete with cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, T&P, sundries and scaffolding required for the work etc. with providing grooves as per specification and direction of Engineer-in-charge.
74Ground Floor
75First Floor
76Terrace Floor
77Servant Quarter
78Providing 6 mm. thick cement plaster with cement mortar of mix (1:4) in all floors at all height with screened and washed sharp sand for mortar to ceiling plaster of roof slab, staircase, landings, chajja and shelves etc. including roughening, scraping, chiseling, cleaning closed deep chipping with slurry treatment and finished smooth to all R.C.C surface including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P , scaffolding, watering and curing etc. complete in all respect as per specification and direction of Engineer-in-charge.
79Ground Floor
80First Floor
81Terrace Floor
82Servant Quarter
83Supplying, fitting and fixing vitrified tile in floors of size 600mm x 600mm coloured / printed series of approved make of premium grade having thickness 8mm to 10mm conforming to IS-13756 on 20mm thick bed of cement mortar (1:4) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties and taxes of all materials complete in all respects.
84Ground Floor
85First Floor
86Servant Quarter
87Supplying, fitting and fixing vitrified wall tiles having dimension 600mm x 600mm coloured / printed series of approved make of premium grade having thickness 8mm to 10mm conforming to IS-13756 as directed by Engineer-in-charge in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties and taxes of all materials complete in all respects
88Ground Floor
89First Floor
90Servant Quarter
91Supplying, fitting and fixing for Granite Slab (upto 0.1 to 0.40 Sqm of approved make conformaing to IS 13755 laid on 20 mm thick cement mortar (1 :4) (1 cement course sand) and filling joints with white cement of approved for kitchen platforms, vanity counters, facias and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge, making gas pipe hole etc. high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights. In all floors and all heights.
92Ground Floor
93First Floor
94Supplying, fitting & fixing of Granite Up to Granite Slab (Above 0.40 Sqm of approved make conformaing to IS 13755 series tiles in dadoes, skirting and risers of steps of size 600mmx 600mm of approved make confirming to IS:13755 laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge
95Ground Floor
96First Floor
97Fixing of Chequered tiles of premium grade having thickness 7mm to 8mm confirming to IS 13755 of size 30cm x 30cm special plain / printed series in floors over 20mm thick bed of cement mortar 1:4 jointed with cement slurry mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance, taxes & royalties of all materials, labour with T&P complete in all respects as per direction of Engineer-in-Charge.
98Ground Floor
99Providing fitting fixing of inter locked paver block of size 80 mm thick and filling the joints with sand of approvedv quality including rubbing & polishing etc comleteincluding cost of all materials, labour with T&P etc. complete in all respect..(As per new SOR 2022 - Cahpter - 25, Sl. no - 25.17.2)
100Ground Floor
101Providing & Fixinng factory made 100% Solid WPC (Wood Polymer Composite) - Door Frame 125 mm x 65 mm Single Rebated Make : (Make : Alstone/ Amulya/ Rajashri plastiwood) made from Wood Polymer Composite (Single Extruded Process) material comparising of virgin PVC polymer of K Value 57-60 (Suspension Grade), Calcium Carbonate and Natural Fibers (Wood Powder/ Rice Husk/ Wheat Husk) and Non toxic additives fabricated with meter Joints after applying PVC solvent Cement & screwed with full body treaded star headed screws having minimum frame density of 780 kg/cbm & an ISO 9001-2015 Certified Company, having good screw holding capacity (Screw Withdrawal strength of (Min. 990 N), Minimum Compressive Strength of 58 N/mm2, Modulus of elasticity 900N/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof, water / Moisture Proof & Fire retardant & Fixed in position with SS Dash Fasteners / Hold Fast of reuired dia and lenght,, all as per specifications drawings as directed by the Engineer-In-Charge. Material test certificate and authentication should be compulsory provided by the manufacturing company. (As per Proceeding of C.C.E. Level committee meeting held on dt. 12.02.2024 at 11.30 A.M.)
102Ground Floor
103First Floor
104Servant Quarter
105Supplying , fitting & fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board (make - Century / Green / Sylvan) pasted with 1mm thk laminate (make - Merino / Century / Green) on both side of approved design and quality including cost of all door fittings and fixtures etc, complete. (As per new SOR 2022 - Cahpter - 25, Sl. no - 25.17.9)
106Ground Floor
107First Floor
108Servant Quarter
109Supply and installig UPVC - 3 tracks sliding windows and 2 sashes (shutter) with SS mesh sash dimension of 58mm x 32mmnand sash dimension of 61mm x 37mm for windows with corners fusions welded, fully reinforced with galvanised steel of 1.2mm to 2mm. The sash will be fitted with 5mm reflective toughened glass of make - saint gobain/ AIS/ Goldplus. The windows must be installed complete with all kinds of ironmonergy (including EPDM gaskets, bridging wedges and glass packers) and with suitable water draining system. Application of silicon sealant from inside / outside of dowcorning / GE or equivalent including cost of all materials, all labour, sundries, T & P etc. complete in all respects as per approved drawings and directions of Engineer in charge.(As per Proceeding of C.C.E. Level committee meeting held on dt. 12.02.2024 at 11.30 A.M.)
110Ground Floor
111First Floor
112Servant Quarter
113Supplying and fitting-fixing of Un-plasticised Poly Vinyl Chloride (UPVC) (FENESTA/ NCL VEKA LTD.). Ventilator/ Top Hung-60-Series duly manufactured using UPVC reinforced profiles of 60 mm x 55 mmx2.5 mm for outer frames, 75 mm x 60 mm x 2.25 mm for casement Window Sash Profile capable of mounting single glazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5 mm prefabricated & welded through fusion welding the window sash shall be fitted with 6 mm thick clear toughened glass of SAINT-GOBAIN make duly fixed with EPDM, weathering seal resistant accessories, like clipping Jocking system tone including cost and conveyance of all materials, accessories, labour charges, materials Nuotiosoite pine thermobninstalled at the nonaktsmeners, silicon rubber sealant, easy glazing/deglazing at site etc..and product conforming to ASTM D 638-14.EN-477-95 and other applicable codes and standards. (AS Per No. B-I (H.E)(WB)-01/2018 , Lt. No. 16100 Dt. 08 May 2023.)
114Ground Floor
115First Floor
116Servant Quarter
117Providing and fixing M.S grill of required patterns for windows/verandahs etc. with M.S flats, square or round bars etc. including applying a coat of approved steel primer and two or more coats of synthetic enamel paint of approved make & shade, all complete as per drawing & specification. (All steel sections contractor's own supply).
118Ground Floor
119First Floor
120Servant Quarter
121Providing & Applying priming coat with Cement primer of approved brand and manufacture on plaster surface as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete.
122Ground Floor
123First Floor
124Terrace Floor
125Servant Quarter
126Providing and applying to outside walls with two or more coats of Anti-Fungal Weather coat paint including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-Charge at all elevations including all material labour complete.
127Ground Floor
128First Floor
129Terrace Floor
130Servant Quarter
131Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall on interior surfaces to prepare the surface even and smooth as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete.
132Ground Floor
133First Floor
134Terrace Floor
135Servant Quarter
136Preparing surface and painting at all height with two or more coats of interior Plastic Emulsion \\"Royale Shyne\\" of Asian Paints or equivalent of approved shade as per the instructions of the manufacturers; giving uniform shade etc in all heights of walls etc. including interior wall primer & providing scaffolding, cleaning, curing and supply of all materials and labour complete as per drawing, design and direction of Architect/Engineer-In-Charge.
137Ground Floor
138First Floor
139Terrace Floor
140Servant Quarter
141Providing & Painting with synthetic enamel paint of approved brand and manufacture to give an even shade as per the instruction of Engineer-In-Charge at all floors and all heights including all material & labour complete.
142Ground Floor
143First Floor
144Servant Quarter
145Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, labour, T&P etc. required for the complete in all respect.
146Ground Floor
147First Floor
1482.5cm (1”) av. thick grading concrete (1:2:2) using 6mm size black hard crusher broken granite chips over roof slab after chipping and chiseling the same and cleaning the surface by brushing laid to proper slope finished smooth to receive tarfelt treatment watering and curing including cost, conveyance, royalties and taxes of all materials with all labour and T&P etc. required for the work complete in all respect in all floors.
149ELECTRICAL WORKRecessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type (anti bactorial & flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (anti bactorial & flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
150GROUP-A
151GROUP-B
152GROUP-C
153Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (anti bactorial & flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
154Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (anti bactorial & flame retradant type)) with suitable size modular box & cover(anti bactorial & falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
155Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A socket(modular type)((anti bactorial & flame retradant type)) with suitable size modular box & cover(anti bactorial & flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
156Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((anti bactorial & flame retradant type)) with suitable size modular box & cover(anti bactorial & flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
157Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6A switch & socket(modular type) ( (anti bactorial & flame retradant type) with suitable size modular box & metallic cover plate (both side)(anti bactorial & flame retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN)/Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
158Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5)
159Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5)
160Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5)
161Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 nos of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit.(LFDB TO LBDB/Medical equipement) (2X6+1X2.5)
162Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 2.5 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB/Medical equipement) (4X6+2X2.5)
163Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make- Havells/Anchor , A catagory ISI marked as approved .as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
164S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
165Supplying and installation of 25A AC starter Modular type, Schneider/Siemens/Legrand coil voltage-230 Volt A.C. on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
166Sub-Head II (Light fitting Fixture & Fan)
167Supplying, installation, of exhaust fan of heavy duty 300 mm sweep (Make-Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.
168Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.(With fan Regulator)
169Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years
170SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years .
171SITC Of Bright 9 Watt LED Bulb with 900 lumens of light output,BEE 3 star rating. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years
172S/F of Street light- 60W,120 lm/w efficacy ,IP PC Lens new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) (5Years Warranty)
173S/f of 15 Ltr capacity of Gyser WITH TEMPERATURE SENSING COLOR CHANGING INDICATOR , Glass coated Anti rust tank with 5 year warrant on tank (Havells/V-Guard/ Bajaj/ Crompton make)
174Supplying, Erection, Fixing, connection & testing of 20W LED GATE Light of Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) maintenance free having 5 years warranty G.I P ipe with braket including MCB box & including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge.
175Supply and Fixing of 2250 VA Inverter, 180 AH battery-2 Nos, & Trolly(Make of V-Guard/Exid/Microtek/Exide/Luminous) with minimum battery warranty of 5 Years.
176Wiring to sub-main with 1x1.5 sqmm single core multi-strand copper wire for inverter wiring
177BDBS,DB,AC DB,FLOOR PANELS,MCBS
178Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9 as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years.
179Supply and fixing of 16 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years .
180Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9. the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 3 years.
181Supplying and fixing 40 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year.
182Supply of A,C with indoor and outdoor unit
1831.5 TR high wall 5 star inverter type split A.C machine (BTU/Hr-18000)with copper condensor & evaporator having ambient temperature 52 degree celcius with comprehensive 1 year warranty,5 years warranty on PCB, 10 years warranty on compressor (Make:O-General/Diakin/Mitsubishi)
184FRAME WORK
185Supply,installation & fabrication of MS base frame for both indoor and outdoor unit and other nesessary material to complete the job.
1861 TR to 3 TR high wall split A.C
187DRAIN PIPING
188Supply,installation & fabrication of Insulated drain water piping from indoor to nearestdrain point separate to all and other nesessary material to complete the job.
18925mm nom. Dia pipe,B1
190Stabilizer
191Supply and fixing of 4kVA Voltage stabilizer (Make-V-Guard/Microtek/Shakti
192Installation Charges of AC Machine
193(Earthing) INSTALLATION
194Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.
195Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
196Providing and fixing 50mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
197PANELS
198MAIN CONTROL PANEL AT GF
199S/I/T&Commissioning of CPRI tested LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by siemens gray powder cote paint fallowed by 9 tank acid treatment is designed as G.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list.80X10MM Separate Aluminium Earth bus bar should be installed.
200In commer-1-01 Nos of 100A,4 Pole MCCB with thermal release range (100-125A) and having breaking capacity of 36 KA ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/L&T etc.(1 FROM TRANSFORMER)
201In commer-2- 01 no of 100A 4P onload changeover switch (Make-HPL/L&T/Siemens/Schneider)
202Busbar- 04 numbers of 200Amps copper busbar with 1.6A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing)
203Outgoing- 03 Nos of 63Amps 4P 415 volts RCCB 30 mA Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The MCB should be Replacement Warranty will be 3 years.
204Outgoing- 03 Nos of 20 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 3 years.
205Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.
206(ii) 01 set of digital type 3 phase voltmeter and ammeter with LED display having accuracy class 0.5
207(iii) All Protection Accessories OV,UV,EF
208CABLING AND END TERMINATION MAIN AREA
209Supplying of one number XLPE Armoured AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge.
2103.5core x 35 sq mm (2 run from TRF to Main LT Panel)
211LAYING OF CABLE
212Laying of one number of PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm direct in ground including excavation, sand cushing, protective covering and refilling the trench etc. as required.
213Supplying and making end termination with double brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.
2143.5 core x 35 sq mm
215P.H workSupplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor GI/PVC pipes, class-IV (10 k.g. F/cm) on firming I.S.4985 of the following nominal bore, tube fittings and clamps including making good the wall, ceiling and floor, testing all complete as per specification and direction of the Engineer in charge.
21632mm dia PVC ASTM pipe (sch-80)
217Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge
218Ground Floor
21920mm dia C - PVC pipe
22025mm dia C - PVC pipe
221First Floor
22220mm dia C - PVC pipe
22325mm dia C - PVC pipe
224Supplying all materials , labour, T&P and fixing rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr width KB brickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 3.40m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips and required steel reinforcement including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxes etc.all complete as per approved drawing , P.H. specification and direction of Engineer-in-charge
2252000 liters capacity PVC water storage tank
2261000 liters capacity PVC water storage tank
227Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.
22815mm dia CP angle stop cock (Con-CHR-053KN Jaquar make)
22915mm dia CP two in one bib cock (Con-CHR-041KN Jaquar make)
23015mm dia CP Long Body Bib cock (Con-CHR-107KN Jaquar make)
23115mm dia CP Bib cock (Con-CHR-047KN Jaquar make)
23225mm dia brass full way valve (Shakti make)
23332mm dia brass full way valve (Shakti make)
23415mm dia CP Health faucet (Con-ALD-MCH-573 Jaquar make)
235CP Extension Piece
236125mm CP grating
23715mm size C.P. flange
23820mm dia CP consealed stop cock (Con-CHR-083KN Jaquar Make)
239WALL MIXER WITH PROVISION FOR OVERHEAD Shower (FLR-ABR-5273UPR)
240supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per direction of Engineer-in-charge.
241Supplying all materials , labour, T&P and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proof as per P.H. specification and direction of Engineer-in-charge
242Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages including watering , curing , cost & conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer-in-charge.
243Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.
244110mm U-PVC SWR Pipe (Ori Plast/Finolex/Supreme Make Type-B)
245110mm U-PVC ‘P’ Trap(Ori Plast/Finolex/Supreme Make)
246110mm U-PVC door bend(Ori Plast/Finolex/Supreme Make)
247110mm U-PVC Plain bend(Ori Plast/Finolex/Supreme Make)
248110mm U-PVC offset without ear(Ori Plast/Finolex/Supreme Make)
249110mm U-PVC Cowl(Ori Plast/Finolex/Supreme Make)
250110mm U-PVC S/Jn door(Ori Plast/Finolex/Supreme Make)
251110mm U-PVC D/Jn door(Ori Plast/Finolex/Supreme Make)
252110mm U-PVC Socket(Ori Plast/Finolex/Supreme Make)
253Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest, fixing 100mm dia HCI 'p' or 's' trap (with/without 50mm dia horn) for water colset squatting pan including jointing the trap with pan in cement mortar (1:1) cutting the floor and mending good the damages , cost & conveyance of all materials to worksite, payment of royality , taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.
254Fixing 580mmx440mm Orissa pan (Hindware/Parryware/Neycer make)
255Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge
25610 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend ( Slimline-white-Parryware make )
257Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C. pan)with integral 'p' or 's' trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing , cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge
258One piece commod (Hindware) ELEMENT Cat No.92084
259Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered 'Hot' and 'Cold' with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost & conveyance of all materials to worksite, payment of taxes etc. all complete as perP.H specification and direction of the Engineer-in-charge
260Halfpedestal basin (560x450) Hindware No. 91049+91115
261Supplying all materials, labour, T&P for fitting & fixing plain edge kitchen sink of all standard sizes with a pair of bracket, C.P. waste, trap, PVC waste pipe and painting brackets including supply of cement concrete, mortar etc all complete as per instruction of Engineer-in-charge. 24\\" x 18\\" x 10\\" Sink with Sink Cock/Bib Cock jayna make
262Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge
26325mmx600mm long CP towel rail (Jaquar ) CAN-ACR-1111N
264CP towel Ring ( Jaquar) CAN-ACR-1121N
265Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rail complete fixed to wooden plugs with CP screws as per specification and direction of Engineer in charge.
266600mmx125mm plate glass shelf with CP guard rails ( Jaquar) AKP-CHR-35771P
267Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm.thick A.C. sheet or ply wood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of Engineer in charge.
268600mmx450mm size B.E mirror (swivelled type)
269Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge
270CP soap holder (Jaquar) CAN-ACR-1131N
271Supplying all materials labor T&P & Fitting & fixing CP shower with rim with supply of red lead and yarn nail complete as per direction of Engineer in charge.
27215mm CP revolving shower ( Jaquar) CON-CHR-209KN
273Supplying all materials , labour, T&P and cutting holes through existing brick or laterite masonry wall for taking U-PVC pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge
274Supplying all materials , labour, T&P and cutting of RCC chajja for taking HCI or U-PVC pipe and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge
275Supplying all materials labour T&P filling sand in lavatories well watered and rammed including lead of materials to work site.
276Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge
277Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge
278Supplying all materials, labour, T&P and providing and fixing Vitrified tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) ( 1 cement : 1 sand ) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge ( Vitrified floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of size Kajaria/Somany/Johnson tile 60cmx60cm special printed series to be pre-approved by the Engineer-in-charge )
279Kajaria/Somany/Johnson tile 60cmx60cm Ground Floor
280Kajaria/Somany/Johnson tile 60cmx60cm First Floor
281Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.
282Supplying all materials, labour, T&P and providing and fixing porcelain glazed tiles in dado skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge( Vitrified mat finish wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of size Kajaria/Somany/Johnson tile 60cmx30cm special plain / printed series to be pre-approved by the Engineer-in-charge )
283Kajaria/Somany/Johnson tile 60cmx30cm Ground Floor
284Kajaria/Somany/Johnson tile 60cmx30cm First Floor
285Granite
286Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 650kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. of make Rajshri Plastiwood/ Alstone/Aramstrong or euivalant as per direction of Engineer-in-charge.
287Factory made Solid WPC door frame of size 90mmx45mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification. of make Rajshri Plastiwood/ Alstone/ Aramstrong or euivalant as per direction of Engineer-in-charge.
288Ext. S/D Portion
289Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufacture's specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge
290110mm dia P.V.C. pipe
291Supplying all materials labour T&P and constructing 1.40m dia x 2.00 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site.
292Supplying all materials ,labour ,T&P and constructing Inspection Chamber of inside size 760mmx760mmx460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-charge
293Inside size 76cmx76cmx46cm with 18” dia RCC MH cover
2942 Nos 20 Users septic tank of size 2.30m x 1.10m x 2.10m Internal size
295Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge.2 x 3.40 x 2.30 x 1.50 =
296Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge with 1st extra lift of 1.50 m over initial laft. 2 x 3.40 x 2.30 x 0.60 =
297Supplying all labor T&P & filling foundation and plinth with excavated materials well watered & rammed etc. all complete as per direction of EIC.
298Supplying all materials, labor T&P providing CC (1:3:6) with 4 cm HG metal including watering curing lead of all materials to site etc. complete.
299Supplying all labor T&P &Providing C.C. (1:2:4) with 12mm size broken hard granite chips including watering curing & lead of all materials to site etc. all complete.
3002 x 3.40 x 2.30 x 0.10 =
3012 x 2.30 x 1.10 x 0.05 =
302Total
303Providing C.C. (1:1½:3) with 12mm size hard granite chips of RCC work including hoisting and laying and curing with lead of all materials to site. 2 x 2.80 x 1.60 x 0.10 =
304Supplying all materials, T&P and providing MS reinforcement for RCC work including cutting, bending, binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauges. 0.90cum x 2.50x 35.32 = 79.47 kg say rs
305Rigid & smooth centering & sheltering for RCC work including falls work & dismantling than after casting including cost of materials in ground floor.
306RCC floor, roof slab chhaja up to 4.430 m height
3071 x 2.30 x 1.10 =
3082(2.80+1.60) x 0.20 =
309Total
310Supplying all materials labour T&P and providing 1st class KB brick work in CM (1:3) in foundation and plinth including watering and curing and lead of materials to site.
3111st footing
3122 x3.10 x 0.40 x 1.40 =
3132 x 1.10 x 0.40 x 1.40 =
3142nd footing
3152 x 2.80 x 0.25 x 0.70 =
3162 x 1.10 x 0.25 x 0.70 =
317Total
318Supplying all materials labour T&P and providing 12mm thick C.P (1:3) including watering curing and conveyance of all materials to site.
3191 x 2.30 x 1.10 =
3202(2.30+1.10) x 2.10 =
3212(2.80+1.60) x 0.60 =
322Total
323Supplying all materials labour T&P and providing cement punning including watering curing and conveyance of all materials to site. Same as plastering
324Supplying all materials labour T&P and fitting and fixing 12mm dia MS/CI step iron including supply of necessary CC(1:2:4) for fixing etc. complete as per PH specification.
325Supplying all materials, labour T&P for providing fitting & fixing 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:2:4) with 12mm size HG chips all complete including watering curing conveyance of all materials to work site payment of royalty all complete as per specification and direction of Engineer in charge.
326Supplying all materials labor T&P filling sand in foundation and plinth with well watered and rammed etc all complete as per direction of Engineer-in-charge. 2 x 3.40 x 2.30 x 0.15 =
3271 No 30 USERS SEPTIC TANK
328Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge. 1 x 4.70 x 2.30m x 1.5
329Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge with 1st extra lift of 1.50 m over initial laft. 1 x 4.70 x 2.30m x 0.73 =
330Supplying all labor T&P & filling foundation and plinth with excavated materials well watered & rammed etc. all complete as per direction of EIC.
331Supplying all materials, labor T&P providing CC (1:3:6) with 4 cm HG metal including watering curing lead of all materials to site etc. complete.
332Supplying all labor T&P &Providing C.C. (1:2:4) with 12mm size broken hard granite chips including watering curing & lead of all materials to site etc. all complete.
3331 x 4.70 x 2.30 x 0.10 =
334providing Bloffal wall 1 x 4.20 x 1.10 x 0.05=
335at adosterace 1/3rd 1 x 1.20 x 1.10 x 0.05 =
336Baffle wall 1 x 1.10 x 1.50 x 0.08 =
337Total
338Providing C.C. (1:1½:3) with 12mm size hard granite chips of RCC work including hoisting and laying and curing with lead of all materials to site.
3391 x 4.10 x 1.60 x 0.10=
3401 x 1.10 x 1.50 x 0.08 =
341Total
342Supplying all materials, T&P and providing MS reinforcement for RCC work including cutting, bending, binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauges. 1.013cum x 2,5 x 35.32 =89.44 say Rs-
343Rigid & smooth centering & sheltering for RCC work including falls work & dismantling than after casting including cost of materials in ground floor.
344RCC floor, roof slab chhaja up to 4.430 m height
3451 x 3.60 x 1.10 =
3462(4.10+1.60)x 0.20 =
347Total
348Supplying all materials labour T&P and providing 1st class KB brick work in CM (1:3) in foundation and plinth including watering and curing and lead of materials to site.
3491st footing
3502 x 4.60 x 0.50 x 0.74 =
3512 x 1.10 x 0.50 x 0.74 =
3522nd footing
3532 x 4.40 x 0.40 x 0.74 =
3542 x 1.10 x 0.40 x 0.74 =
3553rd footing
3562 x 4.10 x 0.25 x 0.74 =
3572 x 1.10 x 0.25 x 0.74 =
358Total
359Supplying all materials labour T&P and providing 12mm thick C.P (1:3) including watering curing and conveyance of all materials to site.
3601 x 3.60 x 1.10 =
3612(3.60+1.10) x2.23 =
362Baffle wall 2(1.10+0.10) x 1.50 =
363out side 2 (4.10+1.60)x0.74 =
364Total
365Supplying all materials labour T&P and providing cement punning including watering curing and conveyance of all materials to site.same as plastering
366Supplying all materials labour T&P and fitting and fixing 12mm dia MS/CI step iron including supply of necessary CC(1:2:4) for fixing etc. complete as per PH specification.
367Supplying all materials, labour T&P for providing fitting & fixing 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:2:4) with 12mm size HG chips all complete including watering curing conveyance of all materials to work site payment of royalty all complete as per specification and direction of Engineer in charge.
368Supplying all materials labor T&P filling sand in foundation and plinth with well watered and rammed etc all complete as per direction of Engineer-in-charge.
369Construction of 1nos production wells including scientific source finding through consolidated and unconsolidated rock with down the hammer drilling rig or combination rig with PVC pipe and installation of submersible pump set with all acessories
370Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only
371Drilling of 200mm dia bore
37200 mtr to 30mtr
37330 mtr to 45mtr
374Drilling of 150mm dia bore
37546 mtr to 213
376Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials.
377200mm dia PVC pipe
37800 mtr to 45 mtrs
379Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance with DIN 2999 part-1/DIN-42225 part-II specification length of pipe (laying length) will be 3 mtrs. The pipes shall be supplied with both external and threaded with free socket. The pipe having external thread at one end i.e female and or belled end. The female end having internal thread is to be belled in order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC/Rubber 'O' ring to make the joint water tight colour of the pipe shall be blue. The name of the manufacture along with batch No class of pipe shall be stranded legibly of each pipe length.
380200mm dia PVC (sch-80) pipe
381Supplying all materials, labour, T&P and providing and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m below ground level (as per drawing) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock at the bottom to ensure sanitary sealing (excluding cost of cement which will be supplied directly by the department)
382Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge
383By DTH Rig
384Supplying all materials, equipment, labour & conducting reconnaissance survey, integrated Hydrological and Geophysical (Electrical Resistivity Method) survey & selection of potential source for exploration of Ground Water including selection and recommendation of site for drilling wells in selected locations in any part of Orissa under the following Geological formation:
385Rocky terrain with boulder formation for 300m depth
386Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge (Texmo/Crompton Greaves/Kirloskar make)
3871 H.P. Single phase/ three phase 3 stage head renge of 20 to 35 mtr with discharge capasity 145 to 110 L.P.M With outlet dia 25 mm
388DOL Control panel
38940mm dia steel short piece
390Well cap
39150mm size CI bracket
3922.50sqmm flat cable
39320mm dia rigid UPVC pipes
394Steel rope with cover
395Labour charges for lowering including transportation
396Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor HDPE pipes and pipe fittings conforming to IS: 4984/2000 (10kgf/sqcm) of the following nominal bore with clamps and jointing by Fusion welding method including testing, making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge
39732mm HDPE pipes (Finolex/Supreme make) Please Enable Macros to View BoQ information

Other Detail

Information Source http://tendersodisha.gov.in/nicgep/app
Download FileName File Description File Size
Download 2f2a0d90-4dce-416d-8b70-d7211cacd8ff.html Tender Documents 0 KB
Download 5CQRDGH.pdf Tender Documents 0 KB
Download BOQ_586040.xls Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.