| 1 | R.C.C. work of proportion M-25 grade having minimum compressive strength in work test of 250 Kg/Cm2 at 28 days using 20 mm and down graded size black hard crusher broken granite stone chips of approved quality and from approved quarry including hoisting lowering and laying concrete and compacting by using vibrators watering, curing for 28 days, centring & shuttering and finishing the exposed surface smooth providing grooves or beads where necessary in all floors including cost, conveyance, royalties and taxes of all materials , cost of all labour with cost of all T&P required for the work etc. complete in all respect but excluding cost and conveyance of M.S. rods or steel & binding wires and labour charges for strengthening, cutting, bending grills and placing in proper position etc complete as per direction of Engineer-in-Charge. Column F.F |
| 2 | Column Head Room |
| 3 | Lintel F.F |
| 4 | Lintel Head Room |
| 5 | Roof Beam F.F |
| 6 | Roof Beam Head Room |
| 7 | Roof Slab F.F |
| 8 | Roof Slab Head Room |
| 9 | Stair caseF.F |
| 10 | Chajja F.F |
| 11 | Chajja Head Room |
| 12 | Cutting, straightening coiled or bent up M.S. Rod or tor steel of SAIL/ TATA / RINL (VIZAG) make including bending, binding, welding and joining if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances, taxes of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors (Linear measurement will be taken and quantity will be calculated basing on the standard weight of B.I.S. for M.S. Rods or tor steel only. Wastage if any, including weight of binding wire will not be considered for measurement) etc. complete as per specification & direction of Engineer-in-charge. F.F |
| 13 | Cutting, straightening coiled or bent up M.S. Rod or tor steel of SAIL/ TATA / RINL (VIZAG) make including bending, binding, welding and joining if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances, taxes of M.S. Rod or tor steel and binding wires of 18 to 21 gauge and labour required for the work for bending, binding and tying the grills in all floors (Linear measurement will be taken and quantity will be calculated basing on the standard weight of B.I.S. for M.S. Rods or tor steel only. Wastage if any, including weight of binding wire will not be considered for measurement) etc. complete as per specification & direction of Engineer-in-charge. Head Room |
| 14 | Fly Ash Brick masonry in C.M. (1:6) using 9\\" size in Super structure using of 23cmx11cmx8cm size brick having a crushing strength of not less than 75 kg per Sq.cm including splays, cuttings, circular moldings, watering & curing for 8 days, cost, conveyance, royalties of all materials, labour with T&P etc. complete in all respect as directed by the Engineer-in-charge. F.F |
| 15 | Fly Ash Brick masonry in C.M. (1:6) using 9\\" size in Super structure using of 23cmx11cmx8cm size brick having a crushing strength of not less than 75 kg per Sq.cm including splays, cuttings, circular moldings, watering & curing for 9 days, cost, conveyance, royalties of all materials, labour with T&P etc. complete in all respect as directed by the Engineer-in-charge. Head Room |
| 16 | Supplying, fitting and fixing of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar of 10mm as per approved drawing and design with cost of all materials & T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-Charge. F.F |
| 17 | Supplying, fitting and fixing of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar of 11mm as per approved drawing and design with cost of all materials & T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-Charge. Head Room |
| 18 | Painting two (2) coats with any approved Enamel paint over a primer to new wood work and iron work including sand papering,polishing the surface smooth with cost,conveyance,taxes of all materials and labour with T&P required for the work etc.complete in all respects F.F |
| 19 | Painting two (2) coats with any approved Enamel paint over a primer to new wood work and iron work including sand papering,polishing the surface smooth with cost,conveyance,taxes of all materials and labour with T&P required for the work etc.complete in all respects Head Room |
| 20 | Supply and fixing of openable UPVC doors with door frame of approved make with 6mm thick glass of approved quality complite with frame, shutters and all fitting and fixtures. F.F |
| 21 | Supplying fitting of two track UPVC Sliding window of approved make with 6 mm thick glass of approved quality complete with frame,shutters and all fitting fixtures. First flooor |
| 22 | Supplying fitting of UPVC ventilator of approved make with 6 mm thick glass of approved quality complete with frame,shutters and all fitting fixtures. first flooor |
| 23 | Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. First Floor |
| 24 | Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. Head Room |
| 25 | Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. F.F |
| 26 | Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. Head Room |
| 27 | Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. First Floor |
| 28 | Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. Head Room |
| 29 | Supplying, fitting and fixing vertified tile in floors of size 600mm x 600mm of approved make confirming to IS 13755 laid on 20 mm thick cement mortar (1:4) (1 cement:5 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-Charge.First Floor |
| 30 | Supplying fitting, fixing of Vetfified tile in Dado of approved make on 12 mm of thick bed of cement mortar (1:3) jointed with neat cement slurry to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties and taxes of all materials with all labour, T&P etc complete in all respects and as per direction of Engineer-in-Charge.First Floor |
| 31 | Supplying, fitting, fixing of Granite tile of size above 0.4 sqm (10mm thick) laid on 10mm to20mm thick of approved quality and shed in floors treads or steps and landing on 25 mm thick Cement mortar (1:1) with jointed with neat cement slury mixed with pigment to match the shades of tiles including rubbing and polishing etc complete including cost, conveyance of all materials, cost of all labour, T&P etc. complete as per the direction of the Engineer-in-charge. F.F |
| 32 | Finishing plastered surfaces with Acrylic wall putty (water based) of approved make and finishing the surface smooth and even by sand papering to receive paint in walls, at all heights with staging wherever necessary with cost, conveyance, taxes of all materials, cost of all labour, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge. F.F |
| 33 | Finishing plastered surfaces with Acrylic wall putty (water based) of approved make and finishing the surface smooth and even by sand papering to receive paint in walls, at all heights with staging wherever necessary with cost, conveyance, taxes of all materials, cost of all labour, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge. Head Room |
| 34 | Painting 2 (two) coats with any approved weather coat over a coat of primer with brush to out wall surface after scraping & cleaning the surface including cost of paint, with cost, conveyance and cess, taxes of all materials and labour with T&P required for the work etc. complete in as per specification and direction of Engineer-in-Charge. F.F |
| 35 | Painting 2 (two) coats with any approved weather coat over a coat of primer with brush to out wall surface after scraping & cleaning the surface including cost of paint, with cost, conveyance and cess, taxes of all materials and labour with T&P required for the work etc. complete in as per specification and direction of Engineer-in-Charge. Head Room |
| 36 | Painting two coats with plastic emulsion paint over a coat of primer to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, taxes of all materials, cost of all labour, T&P etc. complete as per the direction of the Engineer-in-charge First Floor. |
| 37 | Painting two coats with plastic emulsion paint over a coat of primer to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, taxes of all materials, cost of all labour, T&P etc. complete as per the direction of the Engineer-in-charge Head Room |
| 38 | Supplying, fitting, fixing of Stainless steel of 304 grade in hand railing using 50mm dia. of 2mm thick circular pipe with balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. c/c and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in staircase as per approved design and specification, buffing, polishing etc. with cost, conveyance, taxes of all materials, labour, T&P etc. complete as per direction of Engineer in Charge. FF |
| 39 | Providing 2.5cm thick Grading Concrete over roof slab with cement concrete (1:2:2) using 6mm size black hard granite crusher broken chips and screened & washed sharp sand for mortar and finished smooth to the rough surface of slab including watering and curing with cost, conveyance, royalties of all materials with cost of all labour, labour cess and T&P required for the work etc. complete in all respect as directed by the Engineer in charge. Head Room |
| 40 | E.I:-Recessed wiring to light point/Fan point/ Exhaust fan point/Call bell point with 1.5sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal with 6Amp ,250V Modular switch ISI marked and ceiling rose ISI marked mounted on Metal box having front Modular cover of suitable size, Metal box with 1.5sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection (Make of wire-Polycab/Finolex/L&T/Anchor/Havells/V-Guard) (Panasonic Akina/Roma Plus), legrand( Myrius-NEXT GEN),Havells-Crabtree Group-A -L.P- 13 F.P- 3 C.B.P- |
| 41 | Group-B L.P- 9 F.P- 3 C.B.P- |
| 42 | Group-C L.P- 5 F.P- 2 C.B.P- 2 |
| 43 | Supply and fixing of 3 no.sof 3pin 5/6 amp modular socket and 3 Nos.5/6 amp modular switch in recess with suitable size of (3 nos x5A S-S)Modular cover in front including providing and fixing (make-Havells/ Anchor/ Legrand /Roma/panasonic) |
| 44 | Recessed submain wiring alongwith earth wire with the following sizes of PVC insulated single core multistrand copper conductor ISI marked conforming to IS-694/1990 in 20mm dia non metallic heavy duty flexible conduit 1.6 mm in surface /recessed PVC conduit as required (make of wire -Polycab/Finolex/L&T/Anchor/Havells/V-Guard/) 2 X 1.5sq.mm +1 X 1.5sqmm |
| 45 | 2 X 2.5sq.mm +1 X 1.5sqmm |
| 46 | 2 X 4sq.mm +1 X 1.5sqmm. |
| 47 | 2 X 6sq.mm +1 X 2.5sqmm. |
| 48 | Supply and drawing of following size PVC insulated single core multistrand copper conductor in existing surface/recessed/ steel /pvc conduit as required. 2 X 1.5sqmm(Inverter) |
| 49 | Supply and fixing of superior type call bell of ISI marked, on 6\\" X 4\\"conforming to IS-2268/1994 and bell push of ISI marked , conforming to IS-1293/ 1988 (make-Cona/ Anchor) Musical Call bell with battery |
| 50 | Supply and fixing of copper plate earthing( 600 X 600 X 3.15mm )with running copper flat 25 X 5mm from copper plate to funnel of 40mm dia G.I pipe including all accessories |
| 51 | Providing and fixing 8 SWG (4 mm) dia copper wire on surface or in recess for loop earthing as required |
| 52 | Supply and fixing of following way single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) make-Hager/Havells/Legrand/Anchor/schnider 8way, Double door |
| 53 | Supply and fixing of 5Amp to 32A rating 240V \\"B\\" series MCB suitable for lighting and other loads of the following poles in the exiting MCB DB ISI marked complete with connections testing and commissioning etc. as required. (make-Hager/Havells/Legrand/Anchor/schnider single poles MCB LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 Single pole (SP) |
| 54 | Single pole and Neutral (SP&N) |
| 55 | Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, 2P, 240 volts, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 3 years. |
| 56 | Supply and fixing of 4pole MCCB in cubicle pannel board S/F of 100AMP 25KA MCCB of Hager/Havells/Legrand/Anchor/schnider Make with MS box including both side connections with all complete |
| 57 | Supply and fixing of 9Watt LED lamp , Lumens Efficacy minimum rating should meet :105 lumen per watt 6500k (Philips/ Havells/ AnchorBajaj) |
| 58 | Supply and fixing of 10 Watt LED BH Fitting ( Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years |
| 59 | Supply and fixing of 10 watt Mirrior light with all connections. , Lumens Efficacy minimum rating should meet :105 lumen per watt 6500k(Make-Havels/Panasonic/ Philips/Bajaj/Crompton) |
| 60 | S/F of 20W 4' LED fitting Surface LED Light fitting , Lumens Efficacy minimum rating should meet :105 lumen per watt 6500k (Make-Havels/Panasonic/ Philips/Bajaj/Crompton |
| 61 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: PANASONIC/Havells/WIPRO ,PHILIPS Eq.,)The luminaire should be Replacement Warranty will be 2 years |
| 62 | Supply and fixing of fan (make-Usha/Orient/V-Guard/Khaitan/Havells/Crompton/Almonard/V-Guard) S/F of 1200mm Brush Less Direct Current BLDC Ceiling fan with Low wattage consumption fan , Heavy Duty,durable, copper winding,Aluminium blade(ISI mark)Crompton Grave/Khaitan/Havells/Orient/Polycab/V-Guard |
| 63 | Exhaust fan 9\\" size |
| 64 | Supply of PVC/XLPE Aluminium armored cables ISI marked.(Make- GLOSTER/Havells/Anchor. 50sqmm 3 1/2 core |
| 65 | Cable laying on wall surface with steel shaddle 25sqmm to 120sqmm |
| 66 | Supply & Fixing of 1.5 ton Ac Machine /units must have a minimum BEE (Bureau of Energy Efficiency) 3-star being Specific ISEER (4.39). values as of 2025 year ,(Not acceptable of sub branding name of parent company make) Make -Daikin/Carrier/Bluestar/ Hitachi/ Mitusubish) with warranty of 2 years. capacity- 1.5 Ton Split |
| 67 | S/F of 4KVA voltage stabiliser (CG/Shakti/V-guard/Autotac)(I/p-130V to 270V, O/P-200V to 240V) |
| 68 | S/F of Metal Clad Industrial Type Plug, Socket, Interlocked Switch Socket Unit & Distribution Board. Industrial Socket with 20Amp SP MCB for AC point. make- Havells/ polycab/legrand/schneide |
| 69 | Installation charges of AC machine ( indoor &Outdoor Unit ) |
| 70 | S/F of Copper Pipe 5/8\\" to 1/4\\" |
| 71 | S/F of 3 core wire for AC machine |
| 72 | S/F of Drain Pipe |
| 73 | Supply of Invertor,UPS 1650VA Pure Shine wave (Make Microtech/Su-kam/Luminous/Crompton) |
| 74 | Supply of Invertor Battery 12V 150AH(Make Exide/Amrom/Su-kam/Luminous/Crompton with 48 Month warranty) |
| 75 | Supply of Invertor Stand(Make Microtech/Su-kam/Luminous/) Please Enable Macros to View BoQ information |