| 1 | Earth work in excavation in foundation trench in ordinary soil (vide classification of soil item - A ) and disposal of excavated earth as obtained to a distance up to 50 M including all lift , leveling ramming the foundation trenches removing roots of tree shrubs all complete as per approved design building specification and direction of E/I |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soil |
| 3 | Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials. |
| 4 | All kinds of soil |
| 5 | Extra for earth work in hard soil as per specification & direction of engineer in charge ( vide classification of soil item B) |
| 6 | Earth filling in foundation trenches and plinth in layer not exceeding 150 mm thick wall watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trencheed with a lead of 50mm and lift of 1.5 m all complete as per building specification and direction of E/I ( mode of measurement compacted volume ) |
| 7 | Disposal of earth by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. |
| 8 | Providing coarse clean local sand in filling in foundation trench or in pinth including ramming and watering in layer not exceeding 150mm thick with all lead and 1.5 m lift including cost of all material , labous , royality and taxes all complete as per building specification and direction of engineer in charge ( mode of measurement compacted volume) |
| 9 | Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l |
| 10 | Clearing grass and removal of rubbish up to a distance of 50 meters outside the periphery of the area |
| 11 | Treatment of soil under existing floors using chemical emul sion @ one litre per hole, 300 mm apart including drilling12 mm diameter holes and plugging with cement mortar 1 :2(1 cement : 2 Coarse sand) to match the existing floor: |
| 12 | With Chlorpyriphos E.C. 20% with 1% concentration |
| 13 | Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 14 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration |
| 15 | CONCRETE WORK |
| 16 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 17 | RCC WORK |
| 18 | Providing and laying in position machine batched and machine mixed design mix -25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix including pumping of concrete to site of laying but excluding the cost of centering shuttering,finishing and reinforcement, including admixtures in recommended proportion as per IS : 9103 to accelerate retard setting of concrete improve workability without impairing strength and durability as per direction of engineer in charge (note :- cement content considerd in this item is @ 330kg/cum excess /less cement used as per design mix is payable/recoverable separately). |
| 19 | All work upto plinth Level |
| 20 | RCC All work above plinth |
| 21 | Extra for RCC/BMC/RMC/ work above floor v level for each four floor levels |
| 22 | Add for using extra cement in the items of design mix over and above the specified cement content therein. |
| 23 | Concrete of M30 grade with minimum cement content of 350 kg /cum |
| 24 | Providing Tor steel reinforcement of 8mm. dia.TMT rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL)) |
| 25 | Providing Tor steel reinforcement of 10mm,28/32mm dia. TMT rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL)) |
| 26 | Providing Tor steel reinforcement of 12/16mm. & 20/25mm. dia. TMT rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL)) |
| 27 | Centering and shutteing including struting, propping etc and removal of form for |
| 28 | Foundations, footings, bases for columns, etc for mass concrete |
| 29 | Walls ( any thickness) including attached pilasters, butteresses, plinth and string course etc |
| 30 | Suspended floors,roofs,lancing,balcones and access platform |
| 31 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 32 | Columns, Pillars, Piers, abutments, Posts and struts |
| 33 | Stair , ( excluding landings), except spiral staircase |
| 34 | Extra for shuttering in circular work in Suspended floors,roofs,lancing,balcones and access platform ( 20% of respective centering and shuttering items) |
| 35 | Extra for shuttering in circular work in Lintels, beams, plinth beams, girders, bressumers and cantilevers( 20% of respective centering and shuttering items) |
| 36 | Extra for shuttering in circular work in Columns, Pillars, Piers, abutments, Posts and struts( 20% of respective centering and shuttering items) |
| 37 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). uspended floors, roofs, landing, beams and balconies (Plan area to be measured) |
| 38 | BRICKWORK |
| 39 | Providing designation 75 A brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l. |
| 40 | Providing designation 75 B brickwork in C M ('1 :6 ) in foundation and Plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing. taxes and royalty all complete as per building specification and direction of E/l. |
| 41 | Providing Designation 100A B/W with Fly Ash Lime Brick (FALB) conforming to IS 12894-1990 (9\\"x4.5\\"x3\\") in cement mortar (1:6) in Superstructure with clean coarse sand of F.M. 2 to 2.5 including 10mm thick mortar joints,cost of screening, raking out joints to 15 mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l. |
| 42 | Extra for brick work for each consecutive floor above first floor including watering and scaffolding, all complete as per direction of ElC. |
| 43 | Extra for brick work / AAC block masonry / Tile brick masonry in superstructure above floor V level, for each four floors or part thereof by mechanical means |
| 44 | Providing designation 112 mm thick reinforced designation 100 A brick work vuith fly ash lirne brick (FLAG)confirming to lS 12894-1990 (9\\"x4'5\\"x3\\" ) in C.M. ( 1 . 4 ) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carriage of materials,n caffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specificationand direction of E/|. |
| 45 | Extra for providing and placing 2 no 6mm dia MS bar every 3rd coarse of half brick masonary |
| 46 | Extra for half brick masonry in superstructure, above floor V level for every four floors or part thereof by mechanical means . |
| 47 | WOOD WORK |
| 48 | Supplying, fitting and fixing good quality, well dressed and well seasoned sal wood work in chaukhat in doors, windows skylights, fanlights and C/W celetial windows openings, including wedge over all clamps complete including application of two coats of wood preservative of approved quality on the surface butting walls and lintels all completeas per building specification and direction of E/I. |
| 49 | iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii |
| 50 | Supplying fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with both side decorative veneered with black board core bended with high quality phenol formal clehydes synihetic resin of standard make with Aluminium fittings :such as hinges, tower bolts, hendle, cleats and sand blocks and laxes all conrplete as pe building specrfication and direction of E/l. |
| 51 | Supplying fitting and fixing 35mm thick soltd core type decorative double leaf flush door sltutter with both side decorative veneered with black board core bended with high quality phenol formal clehydes synihetic resin of standard make with Aluminium fittings :such as hinges, tower bolts, hendle, cleats and sand blocks and laxes all conrplete as pe building specrfication and direction of E/l. |
| 52 | Providing & Fixing decorative high pressure laminated sheet of plain /wood grain in gloss / matt/ suede finish with high density protectivesurface layer and reverse side of adhesive bonding quality conformingto IS : 2046 Type S, including cost of adhesive of approved quality.9.127.2 1.0 mm thick |
| 53 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (over all area of door shutter to be measured). |
| 54 | Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) :Rectangular or square. |
| 55 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. |
| 56 | Pre-laminated particle board with decorative lamination on both sides. |
| 57 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : |
| 58 | 50x12 mm |
| 59 | Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc.complete. |
| 60 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 61 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 62 | Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/sqm) suitable for mounting 120 minutes Fire Rated Glazed Door Shutters. The frame shall be filled with mineral wool Insulation having density minimum 96Kg/cum. The frame will have a provision of G.I. anchorfastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with factory made template for SS ball bearing hinges of Size 100x89x3mm for fixing offire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- Charge . (Cost of SS ball bearing hinges is excluded). |
| 63 | Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/ m³ and fixing with necessary stainless steel ball bearing hinges of size100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (paneling to be paid for separately). |
| 64 | Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete. |
| 65 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. |
| 66 | With stainless steel cover plate minimum 1.25 mm thickness |
| 67 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). |
| 68 | 12 mm thick frameless toughened glass door |
| 69 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.Upto 5mm depth and 5 mm width |
| 70 | Providing and fixing S.S. sliding door bolts (aldrop) with nuts and screws etc. complete: |
| 71 | 250x16mm |
| 72 | 300 x 16mm |
| 73 | Providing and fixing SS sliding tower bolt with required fastners (Screws) complete: |
| 74 | 250x10 mm |
| 75 | 600 mm |
| 76 | Providing and fixing SS handles \\"D\\" type with required fastners (Screws) complete: |
| 77 | 250x19 mm (Pipe dia) |
| 78 | 200x19 mm (Pipe dia) |
| 79 | Providing and fixing SS hanging floor door stopper with necessary screws etc.complete: |
| 80 | 150 mm Rubber Stopper |
| 81 | Providing and fixing SS door latch with necessary screws etc. complete. |
| 82 | 250x12 mm |
| 83 | Providing and fixing SS sliding baby latch with required fastners (Screws) complete: |
| 84 | 100 x 10 mm |
| 85 | Providing & Fixing Wall mounted door Buffer |
| 86 | Providing & Fixing dormakaba floor spring BTS 75V EN 1-4 with std. spindle and cover plate. The floor spring with backcheck and adjustable closing speed from 175°. . With 90°. hold open. As per EN 1154. (not suitable for fire doors) Finish: Satin stainless steel. Application - Aluminum Doors |
| 87 | Providing & Fixing dormakaba rack and pinion door closer TS 68 EN size 2/3/4, with std. arm and with two independent closing valves and latching speed adjustable by arm. Silver finish. As per EN 1154. |
| 88 | Providing & Fixing dormakaba rack and pinion door closer TS 71 EN size 3/4, with std. arm and with two independent closing valves and latching speed adjustable by arm. Full plastic cover. Silver finish. As per EN 1154. |
| 89 | Providing & Fixing dormakaba Pure Lever handle 8100 lever with roses, 7122 WC Indicator and spindle 8mm x 8mm x 110mm in satin stainless steel. Complete set including the fixing accessories for 50 mm thick door. |
| 90 | Providing & Fixing Mortice dead lock 388a with 55mm backset, 20mm square forend prepared for europrofile cylinder including strike plate. deadbolt, Forend Material: SS 316. as per EN 12209, CE Marked, Fire Rated, Grade 3 Robust, Durability - 200,000 Cycles, Grade 6 High-Security Deadbolt with Anti-Saw Pins,8mm Square hole Clamp Follower, Corrosive resistance - Very High |
| 91 | Providing & Fixing dormakaba 4014 Wall mounted door stop with coat hook in SSS finish |
| 92 | Providing & Fixing dormakaba pull Handle TGDI-D 300 back to back with adjustable fixing for glass, wood and metal doors in satin stainless steel. The pull handles should have supporting washer with raised bevelling on the outer surface. Length =300mm, 22mm dia, -SS304 |
| 93 | Providing & Fixing TGDI D type Offset Pull Handle 350 x 25 mm, CTC - 350 mm, D - 25 mm,Back to back fixing with suitable fixing accessories , SS 304, Finish : Satin |
| 94 | Providing & Fixing Male /Female sign plate 3020-M /3030-F , for WC application with fixing screws size 125 x 125mm, rounded corners in SS 304 satin stainless steel finish. Marking in black |
| 95 | Providing & Fixing dormakaba lever action flush bolt with 19mm projecting bolt L=300mm for Metal door in satin chrome |
| 96 | Providing & Fixing dormakaba 4012 wall mounted door stop dome with 60mm length with fixing accessories |
| 97 | Providing & Fixing dormakaba floor stop half dome with 45mm dia with fixing accessories, in satin Chrome |
| 98 | Providing & Fixing dormakaba DEC 6Plus 6 Pin Euro Profile Single Cylinder with Single side key operation Under Master Key system.Total Length = 43mm.Change Keys - 3 Nos.Finish - Nickel Plated |
| 99 | Providing & Fixing dormakaba lever action flush bolt with 19mm projecting bolt L=300 mm for wood door in satin chrome |
| 100 | Providing & Fixing Disable sign plate 3040-D for WC application with fixing screws size 125 x 125mm, rounded corners in SS 304 satin stainless steel finish. Marking in black |
| 101 | Providing & Fixing dormakaba Pure Lever handle 8100 lever with roses, escutcheons prepared for Euro profile cylinder and spindle 8mm x 8mm x 110mm in satin stainless steel. Complete set including the fixing accessories for 50 mm thick door. |
| 102 | Supply and placing of stainless steel centrifugal air curtain having following specification. The product should be made up stainless steel 304Grade having 4 Blowers(in M. Steel), 2 Motors operating on three phase , Power =2200 Watt having RPM (Max/Min = 2700) and having CFM of 3680. Overall Dimension of 1523X345X351(mm) with Noise level < 68 db. Air Curtain should be provided with velocity control switch and a Door sensor. The product should carry manufacturers warranty of one year from the Date of Supply alongwith Tin Sheet as cover, Bracked and screws*Variations acceptable in parameters above - 5-10%The Product should be complete in all aspect as per Engineer incharge instructions. |
| 103 | Supplying of Queue Manager madeup up of stainless steel material.The pole measures 1130 mm in height and 350 mm in diameter at the base. The belt measures 2 metres in length between the poles and weighs 9.1 kg with the queue manager.Blue, Black, and Red are the available belt colours. |
| 104 | Supply of Fully Automated Shoe Cover Dispenser Machine with Automatic Shoe Counting Function. The machine needs a voltage of 220/50Hz and a rated power of 20W. The machine should have the following dimensions: 750 x 300 x 630 mm.The product will have a one-year general warranty. |
| 105 | Supplying of INTERCONNECTED ROLLING - ALUMINIUM MATTING -5 YEARS WARRANTYProfile Colors : Silver or Black, Position of Matting : Inside/Foyer Area, Material : Aluminium Profile with Carpet, Area : High Traffic,Trolley Crossings : Heavy Trolley, Maintenance : Easy to clean, Application : Recessed / Surface, Warranty : 36 Months |
| 106 | Supply of Powder Coated Galvanized Steel Fire hose cabinet doors. Door frames to be Single rebate profile of 90 x 45 mm manufactured from 1.6mm galvanized steel sheet, profile to have bending radius of 1.4 mm supplied in assembled form ready to install at site. Door Shutter manufactured from single sheet thickness 1.6mm galvanized steel sheet complete with 4mm thick glass with rubber gasket and beading with screw, locking arrangements with Allen key, hinges and flush handle etc. The door frames and shutter should be finished with powder coating with 50- 80micron in desired shade as per direction of Engineer- incharge.Door size: 1500mm x 750mm |
| 107 | Providing and fixing ISI marked 35mm thick flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction : 35 mm thick including Stainless Steel butt hinges with necessary screws. |
| 108 | Supply and Installation of Vertical Louvers, CS- 200 Vertical Fin system components has to be in Aluminum extrusion Alloy 6063-T5/T6/1100/3000 Series, with minimum thickness of the extruded minimum 1.5 mm, with Blades Multi tube tapered from 27” down to 10” projection, extruded aluminum rectangular tube design. Tubes shall be factory assembled to outriggers using stainless steel, type F, thread cutting screws through internal screw slots in blades. Welding is not acceptable. Blades to be mechanically secured to allow for replacement in case of damage. Fasteners to be hex head. All the fasteners used shall be of Stainless steel for the construction of the louvers and should be mechanically fastened. Louver must be factory fabricated and finish so that only assembly/ installation will be done at the site. Finish will as per the approved RAL color in Super durable Powder Coat System, Complying with AAMA-2604 standards. Finish thickness to be minimum 2 mils. |
| 109 | Providing and fixing lead lined door 1200mm x 2100mm , the frame for the door is second class teak wood (ivory cost ) properly seasoned wood of section 100*60mm with a coat of viper make primer and paint. 44mm thick doors shutter are made out of 34mm thick BWP grade board door shutter sandwiching 2mm thick lead sheet of radiation control, 6 mm thick commercial ply and 1mm thick laminate in shuede finish on both the faces of shutter lead lining to be done for frame and shutter both with 2mm thick lead sheet of radiation control. The frames are fitted in masonary opening with the help of anchor fastners of Hilti/Ficher make of size 10*100/10*120mm. 8mm thick Lead lined glass Hardware for the doors are inclusive and includes - stainless steel SS ball bearing hinges 100*75*3 mm of beaker of equivalent make, Dead lock with both side key opration of Becker or equivalent make back to back D handels of size 19*300 mm stainless steel grade of Becker or equivalent make, Face mounted Tower bolt 300 mm long of Becker or equivalent make, face mounted door closer of Becker or equivalent make, all work is being carried out under the direction of Engineer in charge. |
| 110 | roviding and fixing of Clean room doors - 1200mm x 2100mm of Navair/Godrej/Kutty make. The Door is made out of GPSP sheet of Zinc coating not less than 90 GSM. The frame is made out of 1.2 mm thick GPSP sheet having section 10057 mm. Doors shutters are made out of 0.8 mm thick GPSP sheet and having insulation of resin bonded honey comb craft paper. All frames and shutters are finished with Polyester coating of thickness 60-80 micron. The rates also includes the provision of Door hardware like Stainless steel SS ball bearing hinges 100753 mm of Becker of equivalent make, Dead lock with both side key operation of Becker or equivalent make, Back to Back D handles of size 19300 mm stainless steel grade of Becker or equivalent make, concealed flush bolt 300 mm long of Becker or equivalent make, Face mounted door closer of Becker or equivalent make,Both side flush type Vision panel Fitted with 5 mm thick Toughened glass with 20 mm black border, P type seal on perimeter of frame, Door bottom Drop seal of Enviro/Raven make all work is being carried out under the directions of engineer incharge. |
| 111 | STEEL WORK |
| 112 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 113 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 114 | Providing and fixing pressed steel door frames conforming to IS: 4351,manufactured from commercial mild steel sheet of 1.60 mm thickness,including hinges, jamb, lock jamb, bead and if required angle thresholdof mild steel angle of section 50x25 mm, or base ties of 1.60 mm,pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge profile B |
| 115 | Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) |
| 116 | Supplying,frtting and fixing M.S. grill made of 20x6cmm M.S. flat as per approved design and drawing, properly fabrlcated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/1 |
| 117 | Supplying, fitting and fixing M.S. grill gate with M.S. grill made of 20X6mm M.S. flats or 16mm M.S. square bars fitted on 25X25X6mm M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction ofE/I. |
| 118 | FLOORING WORK |
| 119 | providing and laying, Doublecharge vitrified floor tiles in different sizes (thickness to be specified by lhe manufacturer) with water absorption less than 0.08% and conforming to lS 15622/ISO 13009 of approved make in all cotours and shades, laid on 20mm thick cement mortar 1 4 (1 cement:4 coarse sand) jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete Size of tile 600x600 mm |
| 120 | Providing and fixing granite 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for flooring, kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade Area of slab over 0.50 SQM |
| 121 | Providing edge moulding to 18 mm thick marble/granite stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 122 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishingof cut edges etc. complete. |
| 123 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with whitecement and matching pigment etc., complete. |
| 124 | Providing and laying 1st quality Ceramic glazed wall tiles thickness to be specified by the manufacturer) in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointed with white cement including rubbing polishing and cost of curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 125 | Kota stone slab flooring over 25 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1cement : 4 coarse sand) :600x600 |
| 126 | Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, includingrubbing and polishing complete. |
| 127 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge |
| 128 | Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent |
| 129 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slabover 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade includingrubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :11.55.1 Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 130 | Providing & Fixing flexible Conductive PVC sheet flooring of Armstrong/ Forbo/ Polyflor having a total thickness of 2mm and weight of 3kg/m².Colors and pattern detail shall be dispersed throughout the thickness of the wear layer. It shall conform to Group P of Wear Resistance as per EN 649, Flammability of class Bfl-s1 as per EN 13501-1, Slip resistance as per DIN 51130 group of R9 , having REACH Registration No, 1907/2006 contains no substance mentioned in SVHC list. Impact sound reduction of 3 dB as per ISO 140-8, Residual indentation of 0.05 mm as per EN 433, Color fastness rating ≥6 as per ISO 105-B02, Vertical resistance(R1) less than 1 x 10⁶- 1x 10⁸Ω as per EN 1081, and surface resistance less than 1 x 10⁶- 1x 10⁸ Electrical insulation to ground greater than 50 kΩ as per VDE 0100, Static electrical charge of ≤2.0kV as per EN 1815, Thermal resistance of 0.04m²K/W as per EN 12667, Thermal conductivity of 0.25 W/mK. Equivalent to Armstrong PASTELL. Installation:It is important to ensure the sub floor on which the sheet is being laid issmooth, flat & hard & free from moisture, grease, etc. In case of uneven sub floor the |
| 131 | The moisture level present in the subfloor should be less than 8% before installation of the floor. The sheet should be laid using adhesive recommended by company.Each row of tiles/strip of floor covering must be linked crosswise with a continuous copper strip. Individual rows/strips must be at least 3 m² in size and linked to the rest of the area with a copper tape. In rooms of up to 40 m², connection points for equipotential bonding should be provided in at least one point in the room. |
| 132 | Supply and installation of PVC sheet flooring 2 metre wide and overall thickness of 2mm of Armstrong/ Forbo/ Polyflor. The product should be homogeneous and single layered. The wear surface shall consist of impregnated polyurethane homogeneous mixture of PVCwith DIAMOND 10 technology, Plasticizers without DOP, Urethane, color pigments and filler calendered to form a sheet. Product shall conform to group \\"T\\" wear resistance as per EN 649, Flammability resistance of class Bfl-s1 as per EN13501-1, Dynamic coefficient of friction of class DS as per EN 13893, Impact sound reduction of 3dB as per ISO 10140, Slip Resistance of class R9 as per DIN 51130, Color fastness rating of ≥6 as per ISO 105-B02, total weight being 3.3 kg/m2 as per EN430. The product shall be suitable for applications in class 23/34/43 areas as per EN685. Product shall exhibit antistatic behaviour, resistance to bacteria,resistance to chemical, resistance to staining,suitability to castor chair. |
| 133 | Installation- It is important to ensure the subfloor on which the sheet is being laid is smooth, flat, hard and free from moisture, grease etc. In case of uneven subfloor the same should be levelled using self leveling compound which will charged extra. The moisture present in the subfloor should be less than 8% before installation of the floor. dhesive. The installation shall be undertaken as per manufacturers installation instructions. |
| 134 | Providing and laying of 2 - 3 mm average thick layer of cementations smoothening compound of UZIN NC 149 sh or equivalent as recommended by the Vinyl sheet flooring manufacturer over and including a priming compound of UZIN PE 360 sh or equivalent as recommended by the Vinyl sheet flooring manufacturer and installation team on concrete surface to provide a smooth & homogenous surface for laying of vinyl sheet flooring complete to the entire satisfaction of Engineer-in-charge. |
| 135 | Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. |
| 136 | In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) |
| 137 | Acid and alkali resistant tile |
| 138 | Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete. |
| 139 | 8.mm thick Granite of any colour and shade |
| 140 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Dark shade pigment using ordinary cement Please Enable Macros to View BoQ information |
| 141 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Dark shade pigment using ordinary cement Please Enable Macros to View BoQ information |