Indian Tenders

Tender Notice

TDR 54795575
Tendering Authority Urban Development Department
Tender No Jnac/Epro-54/2025-26
Tender ID 2026_UDD_111954_1
Tender Brief Corrigendum : Tender For Waste Water Management System Drains- Moharda, Bagunhathu, Bhijpur Ghat And Zilla School Drain Under Jamshedpur Notified Area Committee (Jnac)
City Jamshedpur
State Jharkhand
Document Fees INR 25000 /-
EMD INR 8661429.0 /-
Tender Value INR 86.61 Crore /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Waste Water Management System Drains- Moharda, Bagunhathu, Bhijpur Ghat And Zilla School Drain Under Jamshedpur Notified Area Committee (Jnac)

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 11-05-2026 DateCorrigendum Date 15-05-2026
2 24-04-2026 TOPOGRAPHICSERVEY Other 11-05-2026
3 24-04-2026 PreBidResponses Other 11-05-2026
4 24-04-2026 Corrigendum2 Date 11-05-2026
5 24-04-2026 TOPOGRAPHICSERVEY Other 15-05-2026
6 24-04-2026 PreBidResponses Other 15-05-2026
7 24-04-2026 Corrigendum2 Date 11-05-2026
8 21-04-2026 Technical Specification Other 11-05-2026
9 21-04-2026 Technical Specification Other 15-05-2026
10 15-04-2026 Corrigendum Date 28-04-2026
11 15-04-2026 Corrigendum Date 28-04-2026
12 15-04-2026 Corrigendum Date 28-04-2026

Key Dates

Publish Date 11-05-2026
Last Date of Bid Submission 15-05-2026
Tender Opening Date 16-05-2026

Contact Information

Company Name Urban Development Department
Contact Person Deputy Municipal Commissioner, JNAC, Sakchi
Address JNAC, SAKCHI, JAMSHEDPUR, EAST SINGHBHUM

BOQ Items

Name of Work:- Waste Water management System Drains- Moharda, Bagunhathu, Bhijpur Ghat and Zilla School Drain under Jamshedpur Notified Area Committee (JNAC)
Sl. No. Item Description
1Earth work in excavation fpr laying of different types and sizes of R.C.C spun pipes with disposal of excavated earth within initial lead and lift as per specification and direction of E/I
2(i) For classification of soil item-A
3(ii) For classification of soil item-B
4Extra for earthwork in all kinds of soil for each additional lift of 1m or part there of over the initial lift of 1,5M as per specification and direction of E/I1.5m to 2.5m
52.5m to 3.5m
63.5m to 4.5m
74.5m to 5.5m
85.5m to 6.5m
96.5m to 7.5m
107.5m to 8.5m
118.5m to 9.5m
129.5m to 10.5m
13Filling in plinth and floors murum bedding itrenches with approved murum from excavated materials from foundation in 15 cm to 20 cm layers including watering and compaction, etc. complete. (Bd-A-10/263)
14Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars piers, abutments, posts and struts etc, above plinth level up to floor five level, excluding cost of centering, shuttering. finishing and reinforcement 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
15Providing Tor steel reinforcement of 10mm, 12mm, & 16mm dia bars as per approved design and drawing -do- -do- (C) 16mm (TMT coil Fe 500) {only valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}
16Centering and shuttering including strutting, propping etc. and removal of forms for Walls (any thickness) including attached pilasters, butteresses, plint abd string courses, etc.
17Earthwork in backfilling the trench after laying different types and sizes of R.C.C. spun pipes woth earth removed during excavation within initial head and lift as per secifications and direction of E/I
18Providing and laying damp-proof course 50mm thich with cement concrete 1:2:4 (1 cement : 2 coarse sand(Zone-III) : 4 graded stone affregate 20mm nominal size)
19Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification
20Supply, Installation, Testing and commissioning of CI Open Channel Sluice Gates, Manually operated, Rising Spindle type suitable for mounting in between two parallel walls of an Open Channel. Water sealing shall be provided at two vertical sides and bottom side of gate aperture by means of rubber seal, mounted on gate slide and having forced contact with gate aperture. The gate shall be designed in such a manner, so that it can be operated at 2 meter head. Gate frame & Shutter of CI Grade IS 210 FG 260, Head Stock IS 210 Grade FG 260, Hinge Pin SS ASTMA276, Yoke IS MS 2062, Flush Bottom Seal Support Bar of SS ASTM A276 , Stem Operating Nut ASTM A276., Duly tested for tensile strength, Chemical testing and tested Shop tested for over all dimensions as per approved GA drawing complete in all respect as per specification and direction of Engineer for following PEAK FLOW up to 3m channel depth.50.1 MLD to 55 MLD
21Supply, fabrication, fixing and Testing of stainless steel (SS-316) Manual Coarse Bar screen with flat bar 50mm X 10mm, spacing of bars 50mm suitable for mounting in channel of specified size with inclination not more than 45 degree and a movable covered containers of 1 cum capacity complete in all respect as per technical specification and the direction of the Engineer. Manually Raked Coarse Bar Screen with 50 mm clear opening for following PEAK FLOW and up to 3m channel depth.50.1 MLD to 55 MLD
22Supply, Installation, Testing and Commissioning of Grit Separator Mechanism including Classifier on one side in inclined position and Organic Return pump interconnection pipes, valves and accessories complete in all respect for following PEAK FLOW as per specification and direction of the of Engineer.50.1 MLD to 55 MLD
23(B) Providing double fiange sluice valve ( Size 50 mm to 1200 mm ) confirming for IS - 2906 / 14846 including worn gear arrangements as per test pressure stailess steel spindle , caps, transportation eto, all complete200MM
24Supply delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Non clog submersible pumping set of 2% Ni CI Cascading, Impeller CF 8M ,Shaft SS 410,mechanical seal with 10M Power & Control cable , 5M Galvanized Chain,,10M, 50mm MS galvanized Guide pipe, Duck Foot Bend, with Guide wire SS 304 etc. complete with all respect as per specification1 DWF (2W + 2S) Discharge 2350 cum/hr and head 21 TO 25 M
25Supplying, erecting, testing and commissioning of diesel generating set with alternator of 250 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 42.30 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 425 Ltr etc. on provided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG
26Providing D.I. pipes (push on joints pressure pipes of D. I. of following class and diameters confirming to the I. S. specification inclusive cost of jointing materials (Rubber gasket of EPDM Quality ) excluding GST levied by GOI & GOM in all respect including Third party inspection charges of TPI Agency approved by MJP including Transit insurance, Railway Freight, Unloading from railway wagon, Loading into Truck, Transportation to departmental store, unloading, stacking etc. completed as directed by Engineer in charges (IS 1536/2001 for pipes and IS 158/1969 and IS 12820/1989 or latest edition/ revision with amendments for Rubber Gaskets.1100MM DI K-9
27Providing and making lead caulked joint with molten lead to Cast Iron pipes and / or specials of all classes and fitting of following dia including cost of lead and all jointing material, labour, hydraulic testing etc. complete.1100MM DI K-9
28Lowering laying and jointing with SBR ruber gaskets C.I. S/S pipes of various classes with CI / MS specials of following diameter in proper position, grade and alignment as directed by Engineer-in-charge including conveyance of material from stores to site of work, including cost of jointing materials and rubber rings labour etc. complete.1100MM DI K-9
29Hydraulic testing of C.I./D.I. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position using water supplied by the contractor.1100MM DI K-9
30Providing and fixing in position air valve shaft including providing and fixing GI Medium Class or 6 mm thick M.S. pipe shaft 2.70 M long over branch flange of air valve tee, providing PCC block of M-150 concrete, 150 mm thick around the air valve tee including encasing of vertical shaft in PCC M- 150 as shown in type design together with providing and making flanged joints wherever required and fixing of air valve tee, etc. complete as per type design and as directed by Engineer -in- charge for following diameters of pipe lines (type design200 to 400 mm
31Providing and supplying Air Valves as per IS- 14845-2000 and MJP’s standard specifications double orifice type combined with isolating sluice valve, mounted in horizontal position and operated by wheel gearing, small orifice elastic ball resting on a gun metal orifice nipple, large orifice vulcanite ball seating on molded seat ring, inlet face and drilled, including insurance, third party inspection charges, loading, unloading, transportation upto departmental store, excluding GST levied by GOI & GOM in all respect etc. complete.200 mm
32Providing double flange sluice valve ( Size 50 mm to 1200 mm ) confirming for IS - 2906 / 14846 including worn gear arrangements as per test pressure stainless steel spindle , caps, transportation etc, all complete1100MM DI K-9
33Supply, Installation, Testing and commissioning of CI Open Channel Sluice Gates, manually operated, Rising Spindle type suitable for mounting in between two parallel walls of an Open Channel. Water sealing shall be provided at two vertical sides and bottom side of gate aperture by means of rubber seal, mounted on gate slide and having forced contact with gate aperture. The gate shall be designed in such a manner, so that it can be operated at 2-meter head. Gate frame & Shutter of CI Grade IS 210 FG 260, Head Stock IS 210 Grade FG 260, Hinge Pin SS ASTMA276, Yoke IS MS 2062, Flush Bottom Seal Support Bar of SS ASTM A276, Stem Operating Nut ASTM A276., Duly tested for tensile strength, Chemical testing and tested Shop tested for overall dimensions as per approved GA drawing complete in all respect as per specification and direction of Engineer for following PEAK FLOW up to 3m channel depth.up to 5 MLD
34Supply, fabrication, fixing and Testing of stainless steel (SS-316) Manual Coarse Bar screen with flat bar 50mm X 10mm, spacing of bars 50mm suitable for mounting in channel of specified size with inclination not more than 45 degree and a movable covered containers of 1 cum capacity complete in all respect as per technical specification and the direction of the Engineer. Manually Raked Coarse Bar Screen with 50 mm clear opening for following PEAK FLOW and up to 3m channel depth.Up to 3 MLD
35Supply, Installation, Testing and Commissioning of Grit Separator Mechanism including Classifier on one side in inclined position and Organic Return pump interconnection pipes, valves and accessories complete in all respect for following PEAK FLOW as per specification and direction of the of Engineer.up to 5 MLD
36Supply delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Non clog submersible pumping set of 2% Ni CI Cascading, Impeller CF 8M, Shaft SS 410, mechanical seal with 10M Power & Control cable, 5M Galvanized Chain,,10M, 50mm MS galvanized Guide pipe, Duck Foot Bend, with Guide wire SS 304 etc. complete with all respect as per specification3 DWF (1W + 1S), Discharge 220 cum/hr and head 21 TO25 M
372 DWF (1W), Discharge 160 cum/hr and head 21 to 25 M
381 DWF (1W), Discharge 110 cum/hr and head 21 to 25 M
39Supplying, erecting, testing and commissioning of diesel generating set with alternator of 25 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 5.0 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 65 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG
40Providing D.I. pipes (push on joints pressure pipes of D. I. of following class and diameters confirming to the I. S. specification inclusive cost of jointing materials (Rubber gasket of EPDM Quality ) excluding GST levied by GOI & GOM in all respect including Third party inspection charges of TPI Agency approved by MJP including Transit insurance, Railway Freight, Unloading from railway wagon, Loading into Truck, Transportation to departmental store, unloading, stacking etc. completed as directed by Engineer in charges (IS 1536/2001 for pipes and IS 158/1969 and IS 12820/1989 or latest edition/ revision with amendments for Rubber Gaskets.250 MM DI K9
41Providing and making lead caulked joint with molten lead to Cast Iron pipes and / or specials of all classes and fitting of following dia including cost of lead and all jointing material, labor, hydraulic testing etc. complete.250 MM DI K9
42Laying of G.I. pipes of approved make in trenches with red lead and yarn with socket and screw joints and cutting pipes to sizes and threading ends where necessary etc. all complete as per specification and direction or Engineer-in-Charge. (Pipes to be supplied departmentally free of cost).250 MM DI K9
43Hydraulic testing of C.I./D.I. pipe line to specified pressure including cost of all materials and labor and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labor, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position using water supplied by the contractor.250 MM DI K9
44Providing and fixing in position air valve shaft including providing and fixing GI Medium Class or 6 mm thick M.S. pipe shaft 2.70 M long over branch flange of air valve tee, providing PCC block of M-150 concrete, 150 mm thick around the air valve tee including encasing of vertical shaft in PCC M- 150 as shown in type design together with providing and making flanged joints wherever required and fixing of air valve tee, etc. complete as per type design and as directed by Engineer -in- charge for following diameters of pipe lines (type designup to 150mm
45Providing and supplying Air Valves as per IS- 14845-2000 and MJP’s standard specifications of approved make and quality of following diameters including railway freight, inspection charges, unloading from railway wagons, loading into truck, transportation up to departmental stores, unloading and stacking excluding GST levied by GOI & GOM in all respect etc. complete.40 mm
46Providing double flange sluice valve (Size 50 mm to 1200 mm) confirming for IS - 2906 / 14846 including worn gear arrangements as per test pressure stainless steel spindle, caps, transportation etc., all complete250MM
47Providing ISI standard R.C.C. pipes in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints, excluding GST lev-ied by GOI & GOM in all respect including inspection charges, transport to departmental stores, unloading and stacking etc. complete as per IS-458/1988.200mm
48250mm
49450mm
50600mm
51Lowering, laying and jointing in proper grade and alignment R.C.C. pipes with collar joints in C.M.1:1 proportion or socketed R.C.C. pipes with rubber joints (excluding cost of rubber ring or R.C.C. collar,) including cost of conveyance from stores to site of work, cost of jointing material, labour, etc. complete as directed by Engineering in-charge (For all class of pipes.) as per IS- 783-1985.200mm
52250mm
53450mm
54600mm
55Hydraulic testing of RCC pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position.200mm
56250mm
57450mm
58600mm
59Providing and constructing on sewer, B. B. masonry circular manhole with concentric cone 1.2 M dia. at bottom and 0.5 M dia. at top and up to a depth of 2.00 M with 23 cm brick work in CM 1:4 proportion excluding excavation including foundation concrete 250 mm thick and haunches and channels in C. C. 1:2:4 proportion, finishing channels in smooth rendering, providing C.I. dapuri type steps each weighing 5.5 kg., 1:2:4 coping and providing and fixing approved make and quality S.F.R.C. frame and cover of 56 cm dia. etc. complete as directed by Engineering in-charge.a) Rebate for every decrease in depth of 50 cm (Rebate to be taken in proportionate to decrease in depth)1.5 to 2.0 m depth
60Providing and constructing on sewer, B. B. masonry circular manhole concentric cone 1.5 M dia. at bottom and 0.5 M dia. at top and up to a depth of 5.00 M with 23 cm brick work, up to depth of 2 M from top and 35 cm thick brick work for balance depth in CM 1:4 proportion with 20 mm thick smooth plaster on both sides in CM 1:2 proportion excluding excavation including foundation concrete 250 mm thick and haunches and channels in C. C. 1:2:4 proportion, finishing channels in smooth rendering, providing C.I. dapuri type steps each weighing 5.5 kg., 1:2:4 coping and providing and fixing approved make and quality S.F.R.C. frame and cover of 56 cm dia. etc. complete as directed by Engineering in-charge.a) Rebate for every decrease in depth of 50 cm (Rebate to be taken in proportionate to decrease in depth)2.0 to 2.5 m depth
612.5 to 3.0 m depth
623.0 to 3.5 m depth
633.5 to 4.0 m depth
64Cyclic Activated Sludge Process1. Designing, providing, constructing, hydraulic testing, commissioning and giving satisfactory trials of 44 MLD Sewage Treatment Plant (STP) based on SBR technology with SCADA & Automation and consisting of Inlet Chamber, Screen Chamber, Detritus Tanks, Distribution Chamber and Biological CASP Basins, Sludge Sump, Chlorine Contact Tank, Chlorinator Room/Shed, Sludge Centrifuge necessary piping work with required valves, gates, drains, pathways Administration Block cum Laboratory, Laboratory Equipment, Tools and Plants, Spare Parts, etc. complete as turnkey job with all involved civil, electrical and mechanical works including HT Substation, Transformers, DG Sets ,Metering cubical, Instrumentation works etc. as per specification inclusive of following items, units as per detailed specification for civil, electrical and mechanical components with all duties and taxes, etc. complete to achieve BOD < 5 ppm, COD < 100 ppm, TSS < 10 ppm, to get recyclable quality of water for industrial / agricultural purposes. (In Case Cyclic activated sludge plant is designed for N, P outlet parameters shall also include TN < 10 ppm, Nh3N < 2 ppm and TP < 1 ppm).* Note: According to MJP SSR 2023-34 Cost per MLD for 40 MLD STP is 98.07 Lacs and Cost per MLD for 50 MLD is 95.76 Lacs by extrapolating these costs the Cost per MLD for 44 MLD STP will be 97.146 Lacs per MLD)2. Designing, providing, constructing, hydraulic testing, commissioning and giving satisfactory trials of STP for inlet Sewage parameters BOD=250, COD=425, TSS=375, TKN 45, pH= 6.5 to 7.5 based on SBR technology consisting of Stilling Chamber, Fine Screen, Grit Detritus Tanks, SBR Basins, Chlorine Contact Tank, Chlorinator with Chlorinator shed & tonner Shed, Chemical Storage & Dosing shed with dosing Equipments, Sludge Sump, Sludge dewatering system equipment and building and sludge storage shed, necessary piping work with required valves, gates, storm water drains and bypass drains, roads & pathways, landscaping, Compound wall with gates, Administration Block cum Laboratory, Laboratory Equipments, staff quarters, Tools and Plants, Spare Parts, Transformer Yard, HT Substation and Metering Room, Security Cabin etc. complete as turnkey job with all involved civil, electrical, instrumentation and mechanical works inclusive of following items, units as per detailed specification for civil, electrical, instrumentation and mechanical components etc. complete to achieve BOD < 5 ppm, COD < 50 ppm, TSS < 10 ppm, to get reusable quality of water for industrial / agricultural purposes. (In Case Cyclic activated sludge plant is designed for N, P outlet parameters shall also include TN < 10 ppm, Nh3N < 2 ppm and TP < 1 ppm) with full automation including PLC-SCADA and Instrumentation and treated effluent disposal line for treated water 1 KM as per specifications.* Note: According to RUIDP SOR, 2022-23 Cost per MLD for 40 MLD STP is 225 Lacs and Cost per MLD for 50 MLD is 200 Lacs by extrapolating these costs the Cost per MLD for 44 MLD STP will be 9,400 Lacs per MLD) Including,i. Site clearance, backfilling up to 2m considering compaction factor, rubble soling, PCC, compaction work to allocated 5.5-6 Acre area for MPS and STP.ii. Development of retaining wall up to 3m height (up to 250m length)iii. Structural strengthening of drain - stone pitching with required vegetation (up to 150m), box culvert with pipes at 2 locationsiv. Miscellaneous work such construction diversion network for the pipe culvert on drain, sluice gate at the outfall and dewatering work etc.
65Operation and maintenance for the entire system for First year including cost of water, electricity, fuel, repair, renewal, consumables, cost of machinaries, maintenance cost civil/mechanical/electrical works, manpower, material cost, safety tools, power, energy cost etc all complete as per direction of engineer in charge.
66Operation and maintenance for the entire system for Second year including cost of water, electricity, fuel, repair, renewal, consumables, cost of machinaries, maintenance cost civil/mechanical/electrical works, manpower, material cost, safety tools, power, energy cost etc all complete as per direction of engineer in charge.
67Operation and maintenance for the entire system for third year including cost of water, electricity, fuel, repair, renewal, consumables, cost of machinaries, maintenance cost civil/mechanical/electrical works, manpower, material cost, safety tools, power, energy cost etc all complete as per direction of engineer in charge.
68Operation and maintenance for the entire system for fourth year including cost of water, electricity, fuel, repair, renewal, consumables, cost of machinaries, maintenance cost civil/mechanical/electrical works, manpower, material cost, safety tools, power, energy cost etc all complete as per direction of engineer in charge.
69Operation and maintenance for the entire system for Fifth year including cost of water, electricity, fuel, repair, renewal, consumables, cost of machinaries, maintenance cost civil/mechanical/electrical works, manpower, material cost, safety tools, power, energy cost etc all complete as per direction of engineer in charge. Please Enable Macros to View BoQ information

Other Detail

Information Source https://jharkhandtenders.gov.in
Download FileName File Description File Size
Download 53c59c27-7b9c-455e-9fb9-0c65feed77cd.html Tender Documents 0 KB
Download BOQ_151161.xls Tender Documents 0 KB
Download SBD44mld.pdf Tender Documents 0 KB
Download Tendernotice_1 (5).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.