Indian Tenders

Tender Notice

TDR 54773022
Tendering Authority Public Health Engineering Department
Tender No 2026D78701F5 5349 4794 BDEA 5350A94DB0FD574PUH
Tender ID 2026_HRY_510099_1
Tender Brief Corrigendum : Tender For Mate:- Providing Sewerage System In Village Bapoli Distt Panipatname Of Work:- Construction Of 2Mld Intermediate Pumping Station (Ips), Laying Of Di Rising Main From Proposed Ips To Stp, Construction Of Treated Effluent Sump And Laying Of
City Bapoli
State Haryana
Document Fees INR 5000 /-
EMD INR 528700.0 /-
Tender Value INR 2.64 Crore /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Mate:- Providing Sewerage System In Village Bapoli Distt Panipatname Of Work:- Construction Of 2Mld Intermediate Pumping Station (Ips), Laying Of Di Rising Main From Proposed Ips To Stp, Construction Of Treated Effluent Sump And Laying Of Di Rising Main From Stp To Drain No.2, Dismantling Of Existing Ohsr And Existing Pump Chamber Etc Operation And Maintenance During Defect Liability Period Of 12 Months After Successful Completion Of 3 Months Trial Run And Thereafter For 5 Years Complete In All Respect. At Village Bapoli And All Other Works Contingent Thereto

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 13-04-2026 Date Extension Date 17-04-2026

Key Dates

Publish Date 13-04-2026
Last Date of Bid Submission 17-04-2026
Tender Opening Date 17-04-2026

Contact Information

Company Name Public Health Engineering Department
Contact Person VIKAS LATHAR
Address Panipat PHED No. 2

BOQ Items

Name of Work:- mate:- Providing Sewerage System in village Bapoli Distt PanipatName of Work:- Construction of 2MLD Intermediate Pumping Station (IPS), Laying of DI Rising Main from Proposed IPS to STP, Construction of Treated Effluent Sump and Laying of DI Rising Main from STP to Drain No.2, Dismantling of Existing OHSR and Existing Pump Chamber etc operation and maintenance during defect liability period of 12 months after successful completion of 3 months trial run and thereafter for 5 years complete in all respect. At village Bapoli and all other works contingent thereto
Sl. No. Item Description
1Credit for Steel, GI pipe and MS Angles etc.
2operation and maintenance for 1st year after defect liability period (12 months).
3operation and maintenance for 2nd year after defect liability period (12 months).
4operation and maintenance for 3rd year after defect liability period (12 months).
5operation and maintenance for 4th year after defect liability period (12 months).
6operation and maintenance for 5th year after defect liability period (12 months).
7operation and maintenance for complete scope of work mentioned in DNIT as per schedule iv for a period of 5 year after 12 month of defect liability period and 3 month trial run period will be charged to annual maintenance estimate complete in all respect.i) operation and maintenance during defect liability period after 3 month trial period (12 Months) ( operaion and Maintainece).
8Providing, supplying, and fixing Manual Coarse Bar screen Channel Width: 900 mm, Channel Depth: 1500mm, Water Depth : 1000 mm, Bar Spacing : 20 mm, Bar Thickness: 10x50mm, Angle of Inclination: 60 Degree MOC : SS-304.
9Providing, supplying, erecting, installing, testing, and commissioning of a multi-compartment LT Indoor panel with A/M change over switch for DG and EB power source, independent feeders for pumps, PLC Control panel , field instruments, Including Pump Monitoring Unit (PMU), UPS, for Pump operation VFD panel with a bypass switch and emergency Star/Delta starter, A/Mswitch for Auto control from PLC, Push buttons for manual operation, status indicating lamps, with reputed make contactors, Volt and Amp meters, cables, MCBs etc. Motor control Panel - having required front surface area, fabricated in fully compartmentalized design from CRCAsheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning and finishing complete with 10 tank spray based tricationic phosphating treatment process for powder coating in approved shade, PU Foam Gasket without manual pasting, joint less (temperature withstand capacity - 40degC to plus 120degC) for maintaining IP protection, power capacitors etc., integrated and synchronized with SCADA master control system of inVillage Bapoli. ensuring the panel complete in all respects to the satisfaction of the Engineer-in-Charge. (designed for a 60HP,40HP,20HP HP non-clog submersible sewage pumps set with an additional 15% loading margin for safety)
10Providing, supplying, erecting, installing, testing, and commissioning of a multi-compartment LT Indoor/outdoor panel with A/M (Auto Manual) change over switch for DG and EB power source, independent feeders for pumps, PLC Control panel , field instruments, including Pump Monitoring Unit (PMU), UPS, for Pump operation VFD panel with a bypass switch and emergency Star/Delta starter, A/M switch for Auto control from PLC, Push buttons for manual operation, status indicating lamps, with reputed make contactors, Volt and Amp meters, Digital Multifunction/Energy Meter, Hour Meter, Surge Protection device, cables, MCBs etc. Motor control Panel - having required front surface area, fabricated in fully compartmentalized design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning and finishing complete with 10 tank spray based tricationic phosphating treatment process for powder coating in approved shade, PU Foam Gasket without manual pasting, joint less (temperature withstand capacity - 40degC to plus 120degC) for maintaining IP protection, power capacitors etc., integrated with SCADA master control system ensuring the panel complete in all respects to the satisfaction of the Engineer-in-Charge.(designed for 200 cum/hr and 35 m head. non clog submersible sewage pumps with an additional 25% loading margin for safety) For Pumps (2W plus 1S)
11Providing, Supplying, erection, testing and commissioning of NON CLOG SUBMERSIBLE SEWAGE PUMPSET(Power Driven Submersible pumps primarily designed for handling waste water with End Suction Enclosed Impeller and Volute Casing) sets fitted with effective motor, mechanical seal, thermal and moisture sensor, suspension device, anti coupling bracket, 10 mguide pipe and Cable From Sump Well to pump Chamber including LT PMU auto coupling with integral bend (with auto coupling Pin SS Foundation Bolt Complete with base frame and RCC Foundation) complete in all respects as per scope of work and specification of Non Clog submersible pumpset of discharge 252 cum/hr, and 35 m head.(60HP)
12Providing, Supplying, erection, testing and commissioning of NON CLOG SUBMERSIBLE SEWAGE PUMPSET(Power Driven Submersible pumps primarily designed for handling waste water with End Suction Enclosed Impeller and Volute Casing) sets fitted with effective motor, mechanical seal, thermal and moisture sensor, suspension device, anti coupling bracket, 10 mguide pipe and Cable From Sump Well to pump Chamber including LT PMU autocoupling with integral bend (with autocoupling Pin SS Foundation Bolt Complete with base frame and RCC Foundation) complete in all respects as per scope of work and specification of Non Clog submersible pumpset of discharge 168 cum/hr, and 35 m head.(40HP)
13Providing, Supplying, erection, testing and commissioning of NON CLOG SUBMERSIBLE SEWAGE PUMPSET(Power Driven Submersible pumps primarily designed for handling waste water with End Suction Enclosed Impeller and Volute Casing) sets fitted with effective motor, mechanical seal, thermal and moisture sensor, suspension device, anti coupling bracket, 10 mguide pipe and Cable From Sump Well to pump Chamber including LT PMU autocoupling with integral bend (with autocoupling Pin SS Foundation Bolt Complete with base frame and RCC Foundation) complete in all respects as per scope of work and specification of Non Clog submersible pumpset of discharge 84 cum/hr, and 35 m head.(20HP)
14Providing, supplying, erection, testing and commissioning Supply and installation of cast iron manually operated sluice gates of size 400 mm (W) × 400 mm (D) to be provided at the receiving chamber, complete in all respects as per IS 13349:1992. The sluice gate shall be suitable for open channel installation, including all necessary components suchas frame, gate leaf, spindle, operating mechanism and anchor bolts. The gate shall be pressure-tight and suitable for sewage application, coated with anticorrosive epoxy paint.
15Providing, Supplying, Installation, testing and commissioning of NON CLOG SUBMERSIBLE SEWAGEPUMPSET(Power Driven Submersible pumps primarily designed for handling waste water with End Suction Enclosed Impeller and Volute Casing) sets fitted with effective motor, mechanical seal, thermal and moisture sensor, suspension device, anti coupling bracket, guide pipe and Cable From Sump Well to pump Chamber and Panel including LT PMU autocoupling with integral bend (with autocoupling Pin SS Foundation Bolt Complete with base frame and RCC Foundation) complete in all respects as per scope of work and specification of Non Clog submersible pumpset of discharge 200 cum/hr and 35m head.
16Providing, Supplying, lowering, stringing, laying and fixing in position Expansion joint as per IS 1538 amended upto date complete in all respect of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications. (150 mm i/d)
17Providing, Supplying, lowering, stringing, laying and fixing in position Expansion joint as per IS 1538 amended upto date complete in all respect of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications. (200 mm i/d)
18Civil Work
19HSR Items Please Enable Macros to View BoQ information

Other Detail

Information Source https://etenders.hry.nic.in
Download FileName File Description File Size
Download 182049ad-d354-4d79-874e-5feb527360c7.html Tender Documents 0 KB
Download 3D3QK7Z154915.pdf Tender Documents 0 KB
Download BOQ_588905.xls Tender Documents 0 KB
Download Tendernotice_1 (4).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.