Indian Tenders

Tender Notice

TDR 54760623
Tendering Authority Irrigation And Public Health Department
Tender No NIT NO. 10773-10810 dated 19.03.2026
Tender ID 2026_HPIPH_132017_1
Tender Brief Corrigendum : Tender For Restoration Of Rain Damages Lwss Palli Kut Lohara In Tehsil Fatehpur Distt Kangra Hp (Sh- Water Proof Treatment Of Existing Collection Tank Of 20 Kl And 10 Kl O/H Tank At Kut ,Making Connection Providing & Fixing Sluice Valve And Repair Of
City Tehsil
State Himachal Pradesh
Document Fees INR 350 /-
EMD INR 8699.0 /-
Tender Value INR 4.34 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Restoration Of Rain Damages Lwss Palli Kut Lohara In Tehsil Fatehpur Distt Kangra Hp (Sh- Water Proof Treatment Of Existing Collection Tank Of 20 Kl And 10 Kl O/H Tank At Kut ,Making Connection Providing & Fixing Sluice Valve And Repair Of Pump House Repair Of Boundary Wall Providing And Fixing Horizontal Centrifugal Monoblock Pump.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 28-03-2026 date of extension Date 04-04-2026

Key Dates

Publish Date 28-03-2026
Last Date of Bid Submission 04-04-2026
Tender Opening Date 04-04-2026

Contact Information

Company Name Irrigation And Public Health Department
Contact Person Executive Engineer
Address EE Jal Shakti Division Fatehpur

BOQ Items

Name of Work:- Restoration of rain Damages LWSS Palli Kut Lohara in Tehsil Fatehpur distt Kangra HP (SH- Water proof treatment of existing collection tank of 20 KL and 10 KL O/H Tank at Kut ,Making Connection providing & Fixing sluice valve and Repair of pump house Repair of Boundary wall providing and fixing horizontal centrifugal Monoblock pump.
Sl. No. Item Description
1Cleaning of all type of concrete /masonary surface by throughly brooming with wire brush & surface grinder to remove the plaster peeling, algae ,dust,dirt and all foreingn material consolidated on surface complete in all respect
2Water proofing treatment on water tank on specified or marked area where heavy leakages are noticed such as bottom of tank and horizontal joints of RCC pannels of walls including cost of cutting holes in the concrete with chieseling hammering and fixing nozzles for injection grouting of water proof compound of reputed and and approved brand such as Perma-Grout or equivalent make at one foot interval to block voids or cappilaries to arrest complete leakages of RCC water retaining structures as per direction and satisfaction engineer-in-charge.
3Providing and laying water proofing treatment on inner wall surface of RCC water storage tank by applying cement slurry mixed with polymer water-proofing compound of approved brand such as Perma Hypercrete or equivalent make in ration 1:1 or as recommended by the company including cost of providing fibre mesh in first layer (over lap of joint of fabric mesh shall not be less then 10cm., final layer of well stirred slurry of cement polymeric water proofing compound such as Perma Hypercrete or equivalent make applied with brush in perpendicular direction complete with cost of cement and sand as per direction and satisfaction engineer-in-charge
4Making connection of G.I. pipe i.e. cutting welding confirming to ISI specifications i.e. commissioning complete in all respects of following dia in gravity main (Earth work in trenches shall be measured and paid for seprately all leads and lifts and as per satisfaction of engineer in charge.
5Repair of pump house
6Demolition of cement concrete in flooring in 1:2:4 (1 cement :2 sand :4 aggregate) including disposal of the waste material complete in all respect as per entire satisfactionn of Engineer in charge.(Pump house Slab)
7Demolition of old 15 mm thick plaster in C.M. 1:6 ( 1 cement : 6 sand ) including disposal of the waste material with in all leads and lifts complete in all respect as per entire satisfaction of Engineer in charge.
8Demolition of old 6 mm thick plaster in ceiling in C.M. 1:3 ( 1 cement : 3 sand ) including disposal of the waste material with in all leads and lifts complete in all respect as per entire satisfaction of Engineer in charge.
9Cement concrete in flooring in 1:2:4(1 cement :2 sand :4 aggregate) complete in all respect as per entire satisfactionn of Engineer in charge.
1015 mm thick plaster in C.M. 1:3 ( 1 cement : 3 sand ) including disposal of the waste material with in all leads and lifts complete in all respect as per entire satisfaction of Engineer in charge.
116 mm thick plaster in ceiling in C.M. 1:4 ( 1 cement : 4 sand ) including disposal of the waste material with in all leads and lifts complete in all respect as per entire satisfaction of Engineer in charge.
12Providing and fixing wood paneled glazed or paneled and glazed shutters for doors, windows and clear story 40mm thick windows including bright finished black enameled iron with necessary screws with second class deodar wood 40mm thick.
13White washing with lime on undercoated wall surface (Two coats) to give an even shade including thoroughly brooming the surface to remove all dirt dust and other foreign matter.
14Finishing wall with water proofing cement paint of approved brand & manufacture & of required shade on undecorated wall surfaces (two coats) to give an even shade after thotoughly brushing the surface to remove all dirt & remains of loose powdered materials.
15Painting two coats(excluding priming coat) on new wood and wood based surface with ready mixed paint brushing the give and even shade including cleaning of all dirt dust and other foreign matter and sand papering and stopping with ready mixed paint other than white.
16Painting two coats (Excluding priming coat on new steel and other metal surface with enemal paint brushing into give an even shade including cleaning the surface of all dirt, dust and other foreign matter enemal paint other than white.
17P/F 20mm PVC Electrical Pipe (HEAVY) ISI approved as per IS:9537 for surface wiring and internl wiring complete in all respecta as per entire satisfaction of Engineer in charge.
18Wiring for sub main wiring with following sizes of PVC insulated conductor single core cable in surface /recessed PVC conduit as required (1.00 sqmm) of finolex /plaza or some ISI make approved make by HPSEB Department complete in all respects within all leads and lifts as per direction and satisfaction of engineer in charge.
19Providing and fixing holder for bulbs Anchor/Havells/Syska make complete in all respect as per entire satisfaction of Engineer in charge.
20Providing and fixing round electrical fan sheet complete in all respect as per entire satisfaction of Engineer in charge.
21Providing and fixing round electrical holder sheet complete in all respect as per entire satisfaction of Engineer in charge.
22Providing installation and commissioning and testing of of LED bulbs 20 watts fittings including 90 degree GI bend choke reflector of Bajaj /crompton /Greaves make complete in all respects within all leads and lifts as per direction and satisfaction of engineer in charge.
23Providing fixing testing and comissioning of ceiling fan 1200 mm(category - A ) and regulator including wiring of the down rod of standard length (up to 30 cm) with 1.5 sqmm PVC insulated copper conductor single core cable etc. as required complete in all respects as per direction and satisfaction of engineer in charge complete in all respects.
24Providing & fixing 3 pin socketoutlet on the existing switch box/cover including connection etc. as required complete in all respects as per direction and satisfaction of engineer in charge complete in all respects.
25Providing and Fixing 2000 ltr Plastic Water tank i/c all fitting of 15 mm like nipple, union, socket complete in all respect as per entire satisfaction of Engineer in chaarge.
26Providing and installing circular stand for resting the water tank(Platic) of 1kl capacity made of iron angles 40x40mm including painting to prevent the rusting of iron and all fitting of 15 mm like nipple, union, socket complete in all respect as per entire satisfaction of Engineer in chaarge.
27Brick work using common brunt clay building bricks in foundation and plinth in cement mortar 1 : 6 ( 1cemnt :6 sand) with in all leads and lifts as per direction and satisfaction of Engineer-in-charge.
2815mm cement plaster in single coat of brick/ concrete/ stone wall in C.M 1:4
29water proofing cement paint of approved brand & manufacture & of required shade on undecorated wall surfaces (two coats) to give an even shade after thotoughly brushing the surface to remove all dirt & remains of loose powdered materials. Please Enable Macros to View BoQ information

Other Detail

Information Source https://hptenders.gov.in
Download FileName File Description File Size
Download b5a4b871-2518-428b-a2b8-e82b6e8ed636.html Tender Documents 0 KB
Download BOQ_195237.xls Tender Documents 0 KB
Download form6.pdf Tender Documents 0 KB
Download form8.pdf Tender Documents 0 KB
Download tc.pdf Tender Documents 0 KB
Download Tendernotice_1 (4).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.