Indian Tenders

Tender Notice

TDR 54665122
Tendering Authority Public Works Department
Tender No WBPWD/EE/CED/eNIT-52/2025-2026
Tender ID 2026_WBPWD_1023123_1
Tender Brief Corrigendum : Tender For Urgent Electrical Repairing Works Of Main Incoming Sytem And Compound Lights At Pundibari Rural Hospital,Cooch Behar.
City Coochbehar
State West Bengal
Document Fees Refer document
EMD INR 8816.0 /-
Tender Value INR 4.40 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Urgent Electrical Repairing Works Of Main Incoming Sytem And Compound Lights At Pundibari Rural Hospital,Cooch Behar.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 25-03-2026 DATE CORRIGENDUM Date 04-04-2026

Key Dates

Publish Date 25-03-2026
Last Date of Bid Submission 04-04-2026
Tender Opening Date 06-04-2026

Contact Information

Company Name Public Works Department
Contact Person Executive Engineer Cooch Behar Electrical Division
Address Sunity Road, Circuit House Campus, Cooch Behar

BOQ Items

Name of Work:- Urgent Electrical Repairing Works of Main Incoming Sytem and Compound Lights at Pundibari Rural Hospital,Cooch Behar.
Sl. No. Item Description
1Dismantling of exixting Panel,Checking of old lines & rectification ,necessary connections by engaging Manpower [1(One)No Semi Skilled Electrician + 2 (Two)Nos Helper Electrician] and Co's own tools & tackles with proper care of electrical equipments and appliances as per direction of EIC
2DBs,MCCB,MCBs,Isolator etc. Supplying and fixing double door Vertical TPN MCB Distribution board for Up to 160A MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachmen [ Make - Legrand Enclosure(607914 )/Schneider/L&T/ABB ]
312 Way
4Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachmen[ Make - LegrandEnclosure Enclosure (607716)/Schneider/Siemens /ABB ]
56 Way
6Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for HorizontalVertical TPN DB enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment
76 Way
812 Way
9Supplying and fixing 415 V,MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection (Make :- LEGRAND/SCHNEIDER/L&T /ABB)
10100A Four Pole
11Supplying and fixing 240/415 V , MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Make: Legrand/Schneider / ABB Equivalent Model of other approved brand as per direction of EIC]
126-32A SP MCB
1363A TP
1463A TP
15Supplying and fixing 240/415V MCB Isolatoror din rail of existing DBs and necessary connection.(Make: Legrand/Schneider / ABB Equivalent Model of other approved brand as per direction of EIC]
1663A FP
17Supply & Laying of AL. Ar. Cable Supplying and delivery of following size Armoured cables XLPE/PVC insulated are designed for 1.1 kV Stranded Aluminium conductor, high tensile galvanized steel wire/strip armour for mechanical protection, and PVC/FR PVC outer sheathing power cable of following size. (Make:Polycab/Havells/KEI / Gloster)
182 core 6 sqmm
194 Core 25 Sq mm
204 Core 50 Sq mm
21Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
22Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
23Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting
24Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below
25For 2 core 6 sqmm
26For 4 core 25 Sq mm
27For 4 core 50 Sq mm
28Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
29For 2 core 6 sqmm
30For 4 core 25 Sq mm
31For 4 core 50 Sq mm
32Supply & Fixing of perforated GI cable tray bend with perforation not more than17.5% suspended from ceiling with two nos.s uspender & 25x25x3 mm angle iron for supporting the cross member incl.S&F GI connector,6 mm dia MS suspender,bolts&nuts,steel fastener etc. as required of the following size. Incl. Al painting of MS support.
33150x50x1.25mm (18SWG)
34Laying of cable as below, on existing Cable Tray and binding withsuitable size GI wire.
35Up to 50 sqmm
36Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
3750 mm dia
3865 mm dia
39Straigh throughJointingof cableof different size by compound jointing kit including S&F ferrul, tapes and jointing materials (Brand approved by EIC)
404 core 25-35 sqmm cable
41Compound Light Supplying, Installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminum body finish with corrosion resistance fasteners (SS hardware) & silicon gasket for proper sealing with driver as per the requirement with Driver efficiency >80%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range 0o to 50o C and working RH 10%- 90%, internal surge protection of 5 KV internal and external SPD min. 10 KV, L,N,E as per IEC 61000-4-5. The driver rated output wattage should be 10% to 15% higher than lamp rating and at least 2 driver for 200W & above and Driver efficiency >85%, THD < 10% as per IEC 61000-3-2 , P. F.≥0.9, IP- 66, IK-08 specified below, CRI >70, under voltage and over voltage protection, high efficiency lens with type II/III distribution as required with UV stabilized optical lens, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends. CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect and LED Chips of SMD mid to high-power (2.5 to 4 watt for 200 watt and above, as per required (LM 80 tested) and necessary inter-connections with 1.5 sq mm FR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. System lumen efficacy shall be as below: System lumen efficacy ≥135 lm/Watt (Make: Crompton / Philips/ Wipro)
42Supplying, installation, Testing & Commissioning of Flood light LED fixture powder coated pressure die cast aluminum body finish with corrosion resistance fasteners (SS hardware) & silicon gasket for proper sealing with driver as per the requirement with Driver efficiency >80%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range 0o to 50o C and working RH 10%- 90%, internal surge protection of 5 KV internal and external SPD min. 10 KV, L,N,E as per IEC 61000-4-5. The driver rated output wattage should be 10% to 15% higher than lamp rating and at least 2 driver for 200W & above and Driver efficiency >85%, THD < 10% as per IEC 61000-3-2 , P. F.≥0.9, IP- 66, IK-08 specified below, CRI >70, under voltage and over voltage protection, high efficiency lens with type II/ III distribution as required with UV stabilized optical lens, life time LED,Driver & electrical circuitry) of minimum 50000 Burning Hours (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends. CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect and LED Chips of SMD mid to high-power (2.5 to 4 watt for 200 watt and above, as per required (LM 80 tested) and necessary inter-connections with 1.5 sq mm FR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. System lumen efficacy shall be as below: System lumen efficacy ≥135 <135 lm/Wat (Make: Crompton / Philips/ Wipro)
43150 W
44Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.
45Fixing only Floodlight Fitting with suitable tie clamps and MS plate for mounting on Pole/Tower or similar structure.
46S&F of 250V, 25A timer controlled single starter for controlling compound lights/ Single Air Conditioning Machines in SS double door 2+10 way DB enclosure (L&T/ABB/ Legrand make) with S&F following electrical accessories & front door locking arrangement with allconnections by finishing the ends of 2 x 4 & 1 x 2.5 mm copper wire with dowells solderless socket by crimping method as to GS, earthing attachment on wall incl.necessary connections as per direction of EIC:-
4725A DP MCB (L&T / ABB / Legrand make) - 1 no.
4824Hr x 7 days programmable Digital timer (L&T make Cat no 67DDTO) - 1 no.
493-pole power contactor (L&T make Cat no MNX22 / 250V)-1 no.
502-Modular AC motor starter (Legrand / Myrius Cat no 673031) -1 no.
511-Module 10A Modular switch (Make Legrand / Myrius) - 1 no.
523-module plate with cover (Make Legrand / Myrius) - 1 no.
5325A Auto-Off-Bipass SPDT toggle switch (approved reputed make) - 1 no.
54LED indication lamp (approved reputed make) - 1 no.
55Outgoing bakelite connector 32A (Reputed make as approved by EIC) - 2 nos.
56Earthing Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire, with an average depth of 3.65 Mts. below the ground level (For soft Soil: By TATA-Medium GI pipe)
57Earthing with 65 mm dia GI pipe (TATA-Medium)x3.0Mts. long and 1No. 50mm x6mm galvanized (Hot Dip) steel strip (4Mts. long), 20mmdia x 125mm long galvanized bolt, double nuts,double washers including finishing both ends by making holes etc.and S& F 65mm dia GI pipe (ISI-Medium) protection(3Mts. long) to b efilled wit hbitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts
58Excavation of soil for installation of Earth Electrode and filling & ramming. (Soft Soil)
59Supplying & fixing earth busbar of galvanized(HotDip)MS flat 40mm x 6mmo nwall having clearance of 6mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
60Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
61Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
62Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages No. 6 SWG
63Note: 1) All the above rates should be quoted inclusive of all taxes, duties and all ancilery charges with cost of maintenance, servicing, supply & replacement of spares for 1 (One) year from the date of commissioning. 2) Total is rounded off to the nearest rupees. Please Enable Macros to View BoQ information

Other Detail

Information Source https://wbtenders.gov.in/nicgep/app
Download FileName File Description File Size
Download 34de514d-0f39-4e11-80ef-1d678384a450.html Tender Documents 0 KB
Download BOQ_2514667.xls Tender Documents 0 KB
Download Tendernotice_1 (6).pdf Tender Documents 0 KB
Download Tendernotice_2.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.