Indian Tenders

Tender Notice

TDR 54645485
Tendering Authority Public Works Department
Tender No PWD/BLDG/TR/1792/2024_6_1_1/1
Tender ID 2026_PWD_847519_1
Tender Brief Tender For General-Re-Allocation Of Diesel Generator Sets (5 Kva - 2 Nos) From District Court Kasaragod To Jfcm-1 & Pocso Court Hosdurg. -Electrification-General Electrical Work
City Kanhangad
State Kerala
Document Fees INR 555 /-
EMD INR 1562.0 /-
Tender Value INR 62477.0 /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for General-Re-Allocation Of Diesel Generator Sets (5 Kva - 2 Nos) From District Court Kasaragod To Jfcm-1 & Pocso Court Hosdurg. -Electrification-General Electrical Work

Key Dates

Publish Date 13-03-2026
Last Date of Bid Submission 19-03-2026
Tender Opening Date 23-03-2026

Contact Information

Company Name Public Works Department
Contact Person Assistant Executive Engineer
Address Assistant Executive Engineer, PWD Electrical Subdivision, Kasaragod

BOQ Items

Name of Work:- GENERAL-Re-allocation of Diesel Generator Sets (5 kVA - 2 Nos) From District court Kasaragod to JFCM-1 & Pocso court Hosdurg. -Electrification-General Electrical Work
Sl. No. Item Description
1Re-allocation of Diesel Generator
21.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
31.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
42.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
52.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
62.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
71.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
81.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
91.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
101.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
111.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
121.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
131.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
141.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
151.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1690.10.3.23:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )16A 3 pin plug top
1790.10.3.32:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator
181.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
1990.10.1.6:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )8 module moulded plastic box on surface
201.28.5:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
21OD234145/2023-2024:Supply and fixing of following sizes of corrugated PVC Flexible conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
2290.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
23OD230210/2023-2024:Labour & Transportation charges for Re-allocation of Diesel Generator sets (5 KVA - 2 No's) from District Court Kasaragod to Hosdurg court Kanhangad.
24OD236846/2023-2024:Supply and fixing Single phase 32A 240V DP Sheet metal Change over switch,and giving Connections etc. Please Enable Macros to View BoQ information

Other Detail

Information Source https://etenders.kerala.gov.in
Download FileName File Description File Size
Download BOQ_1432304.xls Tender Documents 0 KB
Download d955bca5-da78-480c-967d-f2358d26b51c.html Tender Documents 0 KB
Download Tendernotice_1 (1).pdf Tender Documents 0 KB
Download viewsbd.pdf Tender Documents 0 KB
Disclaimer :