| 1 | elefn |
| 2 | 2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 3 | 90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm |
| 4 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 5 | OD446578/2024-2025:Supply and fixing L&T make MR-Gi Single phase starter controller ( manual type) with capacitor dry run preventor and digital indication etc suitable for 2 HP single phase 230 V 50 Hz Submersible motor pumpset on existing board and giving connection as required |
| 6 | 90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm |
| 7 | OD446574/2024-2025:Supply ,laying and jointing of 42 mm or nearest size column pipe of approved make conforming to relevant standards using leack proof materials as required |
| 8 | OD446576/2024-2025:Supply and providing stainless steel adaptor suitable for 42mm/nearest size column pipe as required |
| 9 | OD446577/2024-2025:Supply and providing 20mmor nearest size nylon rope |
| 10 | OD446575/2024-2025:Supply installation testing and commissioning of new 2 HP Submersible motor pumpset suitable for 150mm bore well with 2 HP,1 phase ,50Hz,220V, 58/114/138 MT head, 5000/3250/2000 LPH Discharge HRF 09/25 TEXMO or equivalent make of CRI/DECCAN/KIRLOSKER/V-GUARD delivery size of32/40mm or nearest size using chain pully block and leack proof materials as required and suspended on existing rope including fixing to existing GI/Column pipe as delivery pipe, lowering upto bottom of well at required water level with necessary supports at both ends of motor pumpset, giving all electrical connections and conducting trial run at full load satisfactorily. |
| 11 | OD446572/2024-2025:Supply and providing 40 mm gate valve (brass) on delivery pipe as required |
| 12 | OD446573/2024-2025:Supply and providing40mm non return valve (brass) on delivery pipe as required |
| 13 | OD446579/2024-2025:Supply and providing suitable iron clamp with nut and bolt at top of the well |
| 14 | 1.10.2:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group B |
| 15 | 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 16 | 1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 17 | 1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm |
| 18 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 19 | 1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 20 | 1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 21 | 1.56:Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 22 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 23 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 24 | 1.34:Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 25 | OD492421/2025-2026:Supplying and fixing 9 W LED Bulb including connection etc. as required |
| 26 | 50.18.7.4.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall Please Enable Macros to View BoQ information |