Indian Tenders

Tender Notice

TDR 54645180
Tendering Authority Municipality
Tender No TN/05/25-26
Tender ID 2026_LSGD_845889_62
Tender Brief Tender For Annual Plan-Koolikaavu Ponkunnu Kudivella Padhathu Electrification(Electification @Koolikaavu)_Manathavadi Muncipality-Proj No:S0991/26-General Electrical Work
City Mananthavady
State Kerala
Document Fees INR 335 /-
EMD INR 717.0 /-
Tender Value INR 28691.0 /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Annual Plan-Koolikaavu Ponkunnu Kudivella Padhathu Electrification(Electification @Koolikaavu)_Manathavadi Muncipality-Proj No:S0991/26-General Electrical Work

Key Dates

Publish Date 13-03-2026
Last Date of Bid Submission 19-03-2026
Tender Opening Date 20-03-2026

Contact Information

Company Name Municipality
Contact Person ASSISTANT ENGINEER
Address ASSISTANT ENGINEER MANANTHAVADY MUNICIPALITY

BOQ Items

Name of Work:- Annual Plan-KOOLIKAAVU PONKUNNU KUDIVELLA PADHATHU ELECTRIFICATION(ELECTIFICATION @KOOLIKAAVU)_MANATHAVADI MUNCIPALITY-PROJ NO:S0991/26-General Electrical Work
Sl. No. Item Description
1ELECTRICAL
21.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C
31.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
4OD533397/2025-2026:Supply and fixing of 9W LED Bulb, as required
590.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
61.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
790.14.28.12:S & F Motor starters of the following ratingsSubmersible pump controllers with ammeter,DPMCB for single phase 1.5 HP submersible motor pumps (DOL)
82.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door
92.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
102.10.2:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole and netural
112.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
122.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
132.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required.
14OD529476/2025-2026:Supply and installation of dust and vermin proof Three-phase Sintex Meter Board (GS MB6535) 650*350*250 and to fix kseb meters, fuse unit, CTs, etc. as required including fixing iton the wall, making good the damages, color washing, etc. as required
15OD529417/2025-2026:Supplying and fixing 32A, Bakelite HRC fuse with HRC fuse link with connection, in the existing meter board
16OD529416/2025-2026:Supplying and fixing 32A, 2 way Neutral link mounted on DMC/SMC base with connection, in the existing meter board
175.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
185.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
19OD529488/2025-2026:Supply, providing and fixing 25 x 3mm GI Strip earth lead from the test joint to earth plate
20OD529489/2025-2026:Supply, providing and fixing 2 x 25 x 3mm GI strip test joint and providing 25x6mm brass nut and bolt etc. and connection as required for earthing system Please Enable Macros to View BoQ information

Other Detail

Information Source https://etenders.kerala.gov.in
Download FileName File Description File Size
Download 7df9d38f-5bee-400b-a370-a65bf737740e.html Tender Documents 0 KB
Download BOQ_1432378.xls Tender Documents 0 KB
Download TD991JJJ.pdf Tender Documents 0 KB
Download Tendernotice_1 (1).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.