Indian Tenders

Tender Notice

TDR 54645028
Tendering Authority Public Works Department
Tender No PWD/BLDG/TR/23466/2024_6_1_1/1
Tender ID 2025_PWD_776313_2
Tender Brief Tender For Deposit-Family Health Centr Kurumathur- Supply Installation Testing and Commissioning of Ac And Ups At Laboratory - Supply Installation Testing and Commissioning of Ac And Ups At Laboratory Of Family Health Centr Kurumathur-General Electri
City Kannur
State Kerala
Document Fees INR 555 /-
EMD INR 3848.0 /-
Tender Value INR 1.53 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Deposit-Family Health Centr Kurumathur- Supply Installation Testing and Commissioning of Ac And Ups At Laboratory - Supply Installation Testing and Commissioning of Ac And Ups At Laboratory Of Family Health Centr Kurumathur-General Electrical Work

Key Dates

Publish Date 13-03-2026
Last Date of Bid Submission 18-03-2026
Tender Opening Date 21-03-2026

Contact Information

Company Name Public Works Department
Contact Person Assisstant Executive Engineer
Address Office of the Assisstant Executive Engineer PWD Electrical Subdivision Thalassery

BOQ Items

Name of Work:- DEPOSIT-Family Health Centr Kurumathur- SITC of AC and UPS at Laboratory - SITC of AC and UPS at Laboratory of Family Health Centr Kurumathur-General Electrical Work
Sl. No. Item Description
1UPS and AC installation
2OD241883/2024-2025:SITC of Inverter type wall mounting split Air conditioner unit of the following ratings conforming to relevant IS suitable for operating on 230V, 50Hz single phase AC supply ,filled with R-410 A/R32 refrigerant gas, full copper condenser ,high energy efficient, RoHS complaint, capable of performing functions like cooling, dehumidifying ,air circulating ,filtering etc of following capacity including refrigerant copper piping 3m with insulation, control cable up to 5m,3m drain pipe, Condenser stant, microprocessor control with cordless remote control ,base frame etc. with comprehensive maintenance contract upto the end of 36 months from date commissioning including periodical services, gas topping etc. complete . 1.5 Tr single phase 3 Star rated inverter type Split Ac unit .Make Thosiba/Daikin/Carrier/LIOYD/mitsubishi.
3OD228511/2024-2025:Supply, Installation, Testing and Commissioning of BIS certified 2.0KVA On-line UPS with 3 Year onsite warranty with following specification a. Input Voltage range : Single Phase 3 Wire, 230V/45-55Hz AC,voltage range 160-260V b. Output capacity :2 KVA c. Output Waveform : True Sine wave d.Isolation Transformer : Built-in e.output volatage : Single Phase 230V AC ,Voltage Regulation +/-1% f. Switching Device : IGBT Technology (IGBT power modules with 100A or above) g.Metering : "Digital meter with LCD display,AC input voltage, AC output voltage, Frequency, Battery DC " h. Power factor : 0.8 to Unity i. Over load capacity : 100%-125%, j. Indicators : "Mains ON, UPS ON, Battery ON, charging, overload etc l. Battery :6 NOS 40AH "C10 Tubular Battery Prefrably:Exide /Amaron, (12V each of same rating) m.Warranty : 4 year replacement for battery and 3 year for UPS n. Efficiency : 90% or above o. Battery rack : Painted MS angle iron rack Suitable for the battery supplied. p.Certification : For UPS Manufacturer ISO 9001,ISO:14001 q. Certification For Battery Manufacturer ISO 9001, ISO:14001
41.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
51.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
62.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
72.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
82.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
91.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
101.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1190.10.3.23:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )16A 3 pin plug top
1290.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
1390.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
141.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1590.1.1.1:Supply and laying medium gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement, tying & fixing the conduit firmly with the re-inforcement etc. as required.20 mm
161.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
171.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
181.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm Please Enable Macros to View BoQ information

Other Detail

Information Source https://etenders.kerala.gov.in
Download FileName File Description File Size
Download 43c4a8c4-409b-4570-aa22-b47de168e177.html Tender Documents 0 KB
Download BOQ_1431553.xls Tender Documents 0 KB
Download MOM.pdf Tender Documents 0 KB
Download specificconditionNEW.pdf Tender Documents 0 KB
Download Tendernotice_1 (1).pdf Tender Documents 0 KB
Download viewnit.pdf Tender Documents 0 KB
Download viewsbd.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.