| 1 | UPS and AC installation |
| 2 | OD241883/2024-2025:SITC of Inverter type wall mounting split Air conditioner unit of the following ratings conforming to relevant IS suitable for operating on 230V, 50Hz single phase AC supply ,filled with R-410 A/R32 refrigerant gas, full copper condenser ,high energy efficient, RoHS complaint, capable of performing functions like cooling, dehumidifying ,air circulating ,filtering etc of following capacity including refrigerant copper piping 3m with insulation, control cable up to 5m,3m drain pipe, Condenser stant, microprocessor control with cordless remote control ,base frame etc. with comprehensive maintenance contract upto the end of 36 months from date commissioning including periodical services, gas topping etc. complete . 1.5 Tr single phase 3 Star rated inverter type Split Ac unit .Make Thosiba/Daikin/Carrier/LIOYD/mitsubishi. |
| 3 | OD228511/2024-2025:Supply, Installation, Testing and Commissioning of BIS certified 2.0KVA On-line UPS with 3 Year onsite warranty with following specification a. Input Voltage range : Single Phase 3 Wire, 230V/45-55Hz AC,voltage range 160-260V b. Output capacity :2 KVA c. Output Waveform : True Sine wave d.Isolation Transformer : Built-in e.output volatage : Single Phase 230V AC ,Voltage Regulation +/-1% f. Switching Device : IGBT Technology (IGBT power modules with 100A or above) g.Metering : "Digital meter with LCD display,AC input voltage, AC output voltage, Frequency, Battery DC " h. Power factor : 0.8 to Unity i. Over load capacity : 100%-125%, j. Indicators : "Mains ON, UPS ON, Battery ON, charging, overload etc l. Battery :6 NOS 40AH "C10 Tubular Battery Prefrably:Exide /Amaron, (12V each of same rating) m.Warranty : 4 year replacement for battery and 3 year for UPS n. Efficiency : 90% or above o. Battery rack : Painted MS angle iron rack Suitable for the battery supplied. p.Certification : For UPS Manufacturer ISO 9001,ISO:14001 q. Certification For Battery Manufacturer ISO 9001, ISO:14001 |
| 4 | 1.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm) |
| 5 | 1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm) |
| 6 | 2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door |
| 7 | 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 8 | 2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 9 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 10 | 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 11 | 90.10.3.23:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )16A 3 pin plug top |
| 12 | 90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket |
| 13 | 90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator |
| 14 | 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 15 | 90.1.1.1:Supply and laying medium gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement, tying & fixing the conduit firmly with the re-inforcement etc. as required.20 mm |
| 16 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 17 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 18 | 1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm Please Enable Macros to View BoQ information |