Indian Tenders

Tender Notice

TDR 54644765
Tendering Authority Public Works Department
Tender No ESDT/ET-272/2025-26
Tender ID 2026_PWD_841419_2
Tender Brief Tender For General-Rest House, Thycadu, Thiruvananthapuram New Block Ac Rooms And Non Ac Rooms Renovation-Renovation Except Room No 14,17 & 18 -General Electrical Work
City Thiruvananthapuram
State Kerala
Document Fees INR 555 /-
EMD INR 4234.0 /-
Tender Value INR 1.69 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for General-Rest House, Thycadu, Thiruvananthapuram New Block Ac Rooms And Non Ac Rooms Renovation-Renovation Except Room No 14,17 & 18 -General Electrical Work

Key Dates

Publish Date 13-03-2026
Last Date of Bid Submission 19-03-2026
Tender Opening Date 21-03-2026

Contact Information

Company Name Public Works Department
Contact Person AEE
Address PWD Electrical Sub Division Tvpm

BOQ Items

Name of Work:- GENERAL-Rest house, Thycadu, Thiruvananthapuram new block AC Rooms and non AC Rooms Renovation-Renovation except Room No 14,17 & 18 -General Electrical Work
Sl. No. Item Description
1Rest house Thycadu Thiruvananthapuram new block Non AC Rooms and AC Rooms Except Room no 14,17 &18
290.3.19.3:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture
390.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
4OD316674/2025-2026:Supply Conveyance, installation , testing and commissioning of exhaust fans of size 300/305 mm sweep Light Duty Exhaust fan in metal frame working on 230 V A/C single phase A/C existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan.
51.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
61.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
71.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
81.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
91.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
101.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
111.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
121.27.6:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm)
132.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door
142.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps
152.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
162.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole
172.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
18OD320689/2025-2026:Supply and fixing 5W ( 1 Feet) LED mirror lamp in position and giving connections as required.
191.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
201.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
211.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
221.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
231.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
2490.10.3.14:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A SP switch with indicator
2590.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
261.28.1:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
271.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
281.28.3:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module
291.28.4:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
301.28.5:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
311.28.6:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.12 Module
32OD334205/2025-2026:Supply, conveyance, installation, testing and commissioning of Wall light suitable for LED bulbs (Philips make'' COMET'' Model No 30575/31/86 or equivalent) and giving connections with the extended original wiring etc. as required.
33OD334230/2025-2026:Supply and providing 9W LED BULB of minimum efficacy 105 lumen/watt Please Enable Macros to View BoQ information

Other Detail

Information Source https://etenders.kerala.gov.in
Download FileName File Description File Size
Download specialconditionsmodified.pdf Tender Documents 0 KB
Download Tendernotice_1 (1).pdf Tender Documents 0 KB
Download viewsbd.pdf Tender Documents 0 KB
Download 69818a19-c57b-4e2c-a413-c4b248d0aea4.html Tender Documents 0 KB
Download BOQ_1432387.xls Tender Documents 0 KB
Download mom1MAIN.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.