Indian Tenders

Tender Notice

TDR 54639675
Tendering Authority Public Works Department
Tender No 154/T of 25-26 of AE/BESD
Tender ID 2026_WBPWD_1022179_1
Tender Brief Tender For Construction Of Plant And Manifold Room With Connecting Bridges For Set Up Of Mgps Connection For New 100 Bedded Building, Habra Sgh - electrical installation Work.
City Habra
State West Bengal
Document Fees Refer document
EMD INR 5360.0 /-
Tender Value Refer document
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Construction Of Plant And Manifold Room With Connecting Bridges For Set Up Of Mgps Connection For New 100 Bedded Building, Habra Sgh - electrical installation Work.

Key Dates

Publish Date 13-03-2026
Last Date of Bid Submission 24-03-2026
Tender Opening Date 27-03-2026

Contact Information

Company Name Public Works Department
Contact Person ASSISTANT ENGINEER P.W.D
Address OFFICE OF THE ASSISTANT ENGINEER P.W.D BARASAT ELECTRICAL SUB DIVISION SUB STATION BUILDING, HATIPUKUR BARASAT NORH 24 PARGANAS

BOQ Items

Name of Work:- Construction of plant and manifold room with connecting bridges for set up of MGPS connection for new 100 bedded building, Habra SGH - EI work.
Sl. No. Item Description
1Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC Average Run -- 08 Mtr.
2Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECCOn Board
3Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works 19 mm dia 3 mm thick polythene pipe without earth continuity wire
4Supplying and Drawing 1.1 KV single core stranded 'FR'PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC
52x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC
62x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC
7Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes as per GS.
82.5 Sq mm
94 Sq mm
106 Sq mm
11Supplying & Fixing Industrial Plug & Socket board with 240 V, 20A, SPN & Earth Metal Industrial Plug socket & 20A Industrial top incl. S&F 20 A SP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection.
12Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite /perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
13Supplying and fixing 415V, 32A TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. ( Make - Havells/L &T/Siemens )
14Supplying and fixing Sheet steel Main Switches onflat iron frame on wall 240 V, 16 A DP Main Switch with fuse on L&N ( Make - Havells/L &T/Siemens )
15Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall as per GS.
16(2+4) Way Enclosure (607712) [ Make - Legrand ]
17Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damagesas per GS.
18Upto 160A, 4 Way Enclosure ( 607913 ) [ Make - Legrand/Siemens/L&T ]
19Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs as per GS.
206-32 A SP MCB [ Make - Legrand/Siemens/L&T ]
2140 A TP MCB [ Make - Legrand/Siemens/L&T ]
22Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs as per GS.
2332 A DP Isolator [ Make - Legrand/Siemens/L&T ]
24Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection.
25160 A Four Pole [ Make - Legrand ]
26Supply & Delivery of 2 Core PVC/XLPE Insulated & Sheathed Armoured Aluminium Conductor Cables for Working Voltage up to 1100 Volts of following sizes. [ Make - Polycab/Gloster/RR Kabel ]
272 core 6 Sq mm. cable.
28Supply of 4 Core PVC/XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes. [ Make - Polycab/Gloster/RR Kabel ]
294 core 70 Sq. mm Cable.
304 core 10 Sq. mm Cable.
31Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as per GS. [ For 2 core 6 Sq mm. ]
32Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting [ For 3 core 6 Sq mm.]
33Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed [ 4 Core 70 Sq mm. ]
34Boring/ Micro tunnelling for CC road crossing below 600 mm from GL level for laying of 4 core 70 sq.mm. XLPE/Ar. Al cable through GI pipe protection incl. mending good the damages as per direction of EIC.
35Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry as per GS.
362 core 6 Sq mm.
374 core 10 Sq. mm.
384 core 70 Sq. mm.
39Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make) as per GS.
402 core 6 Sq mm. cable
414 core 10 Sq. mm.
424 core 70 Sq mm. cable
43Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
44Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling with HW block and suitable size MS fastener, Ceiling plate, nipples etc. as required
45Supply & Delivery of Single LED Fitting (18 watt, 230 V AC, 50 Hz, 4000K NW, THD< 10%, built in 2.5 KV SPD) with all accessories and 1 nos. LED Tube, as directed by EIC, Luminious efficacy > 105 & <120 Lumen/watt. The LED luminaves & accessories shall have BEE certification.
46Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box.
47Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw as per GS.
48Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
49Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible as per GS.
5030 cm. ( 12 '')
51Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long)
52For Aluminum, 30 cm. Exhaust Fan ( 12 '')
53Supply of 240V, 1- Phase AC Ceiling Fan complete with all accessories having the following [ Make - Crompton Greaves HS Plus Five Star/ USHA Striker/Orient ]
541200 mm Sweep AC Ceiling Fan , Colour - White
55Supply of 240V,1-Phase AC Light Duty Exhaust fans complete with all accessories having the following [ Make - EPC /Crompton Greaves]
5612 '' ( 300 mm ), Speed - 1420 RPM
57Excavation of soil for installation of Earth Electrode and filling & ramming.
58For Soft Soil
59Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level By ISI-Medium GI pipe with excavation of soil
60Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
61Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages, No. 4 SWG Please Enable Macros to View BoQ information

Other Detail

Information Source https://wbtenders.gov.in/nicgep/app
Download FileName File Description File Size
Download 2911.pdf Tender Documents 0 KB
Download a73e1371-889d-473e-a3ed-f525483b4c8e.html Tender Documents 0 KB
Download BOQ_2512267.xls Tender Documents 0 KB
Download Tendernotice_1 (5).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.