Indian Tenders

Tender Notice

TDR 54638924
Tendering Authority Public Works Department
Tender No WBPWDTE/AE/BMCESD/NIQ-45/Q of 2025-2026_2nd call
Tender ID 2026_WBPWD_1020611_2
Tender Brief Tender For Annual Maintenance Of The electrical installation Work At Lokpur Admin And Academic Building, Mrd, Cardiology, Eye Opd Allied Non Residential Type Building Of Bsmch Under Bsmch Electrical Section Iii, Pwd Te For The Year Of 2024-2025.-----
City Bankura
State West Bengal
Document Fees Refer document
EMD INR 9950.0 /-
Tender Value Refer document
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Annual Maintenance Of The electrical installation Work At Lokpur Admin And Academic Building, Mrd, Cardiology, Eye Opd Allied Non Residential Type Building Of Bsmch Under Bsmch Electrical Section Iii, Pwd Te For The Year Of 2024-2025.-----Replacement Of Old Rusted Dbs And Damaged Cable & Street Light Fittings Incl. Paintig Of St Pole & Feeder Pillers At Different Loaction Under Bankura Bmc Electrical Section-Iii, Bankura.

Key Dates

Publish Date 13-03-2026
Last Date of Bid Submission 17-03-2026
Tender Opening Date 19-03-2026

Contact Information

Company Name Public Works Department
Contact Person AE/BMCESD/PWD
Address Kenduadihi, Gobindanagar Hospital campus, Bankura-722102

BOQ Items

Name of Work:- Annual maintenance of the EI work at Lokpur Admin and Academic Building, MRD, Cardiology, Eye OPD allied non residential type building of BSMCH under BSMCH Electrical Section III, PWD te for the year of 2024-2025.-----Replacement of old rusted DBs and damaged cable & street light fittings incl. paintig of ST Pole & Feeder pillers at different loaction under Bankura BMC Electrical Section-III, Bankura.
Sl. No. Item Description
1Supply of XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make:- Gloster/Polycab /Havells/RR][For Eye IPD street light damaged cable replacement & for Badminton Court at Ladies Hostel] 2 Core 10 Sqmm
2Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed as per GS.
3Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below as per GS. 4 core 10 sqmm [7(c)/F-4]
42 core 10 sqmm [7(a)/F-4]
52 core 6 sqmm [7(a)/F-4]
6Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials as per GS. 4 core 10 sqmm cable [8(b)/F-5]
72 core 10 sqmm cable [8(b)/F-5]
82 core 6 sqmm cable [8(b)/F-5]
9Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required as per GS. 50mm Dia [11(d)/F-6] [For loop Box installation]
1065mm Dia [11(e)/F-6] [For loop Box installation]
11Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint as per GS. [5/H-5]
12Supplying & Fixing of SMC water proof type Loop box (Make-Sintex) of size 8\\"X10\\" comprising of hinged PVC top cover & 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement having suitable arrangement for installing DIN type MCB by installing DIN. The box has been fixed on pole near base incl. S&F of clamps with bolts & nuts as per direction of EIC.
13Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required as per GS. 3x1.5 Sqmm [1(b)/E-9]
144x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC [1(d1)/E-9]
15Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes as per GS. 1.5 Sqmm [NS]
162.5 Sqmm [9(i)/F-5]
174.0 Sqmm [9(ii)/F-5]
186.0 Sqmm [9(iii)/F-5]
1910 Sqmm [9(iv)/F-5]
20Cutting Channel of size (40 mm x 40 mm)/(43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19/25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles as per GS. 25 mm dia 3 mm thick [ 7 (a)/ E- 3 ]
21Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating as per GS. [Make: L&T, Seimens, Schneider] [For Quarter] 100A [4(a)/D-3]
22Supplying and fixing Sheet steel Main Switches on flat iron frame on wall as per GS.[Make: Standard/HPL/Havells] [For Quarter] 30/32A [1(a)/D-1]
23Dismantlling of existing HTPNDB at new ladies hostel with CO's own manpower, tools & tackels as per direction of EIC.
24Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment as per GS. ( Make - Legrand/ABB/Seimens ) [ For quarter) 6 Way
25Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS ( Make - Legrand/ABB/Seimens ) 40 A DP [6(a)/D-5]
2663A FP [6(a)/D-5]
27Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS. ( Make - Legrand/ABB/Seimens ) [For Hostel] 6-32A SP [7/D-6]
28Fixing only Floodlight Fitting with suitable tie clamps and MS plate for mounting on Pole/Tower or similar structure as per GS. [20(a)/C-3]
29Supply & Delivery 240V 90W LED street Light having luminious effeciency of 110-120lm/w incl. IP66 protection complete with all accessories as per direction of EIC. (Make: Bajaj, Model.- VISTA P 117L WH PO PC SD/ Phillips/Crompton) [NS] [Analysis Attached] [With 3 years on site warrenty]
30Supply & Delivery 240V 150W LED flood Light having luminious effeciency of 110lm/w & CCT: 3000K/5700K incl. IP66 protection complete with all accessories as per direction of EIC. (Make: Bajaj, Model.- PRAZEF 210L WH NB- A3 PC SD/ Phillips/Crompton) [NS] [Analysis Attached] [With 3 years on site warrenty]
31Supply & Delivery 240V 200W LED flood Light having luminious effeciency of 110lm/w & CCT: 3000K incl. IP66 protection complete with all accessories as per direction of EIC. (Phillips/Crompton/Bajaj) [NS] [Analysis Attached] [With 3 years on site warrenty]
32Supply & Laying of 100mm dia UPVC pipe in underground at an average dept of 600mm & 500mm wide after cutting the existing bituminous road & soil with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed & mending the damages as per direction of EIC. [For Lokepur Campus]
33S&F of 250V Single timer DB (equivalent to 8 way SPNDB in size) with double door sheet steel enclosure, neutral bar, din rail, with lP43 protection comprises with 32A DP MCB(C-curve 10ka) and 1 no 24 hr digital time switch and 1 nos. 25A modular type power contactor complete and 1 nos SP MCB outgoing with internal wiring with suitable size of copper wire includ LED indicator and earthing attachment as per direction of EIC. [NS] [Analysis Attached]
34Supply of 230V/50Hz, 2 KW AC, 8 bars, 10 litr storage, Thermostat control, Thermal Cutout, multi function, ISI Certification Closed Water Heater (Geyser). Inner Tank: Porcelain Enamel Glass Lined Tank. Double Side enameling prevents rusting of flange and door plate. Heating Element: Copper Tubular Element.Outer Body Material: Plastic Outer Body. Indicator: Smart Indicator Color changing LED ring. (Make - VENUS, Model - Splash Pro or equivedlent model of Bajaj) (For Gynae Building)
35Supplying and fixing double door SPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS.( Make - Legrand/L&T/Seimens ) 2+10 way [ 13 / D- 9 ]
36Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS ( Make - Legrand/ABB/Seimens ) 40 A DP [6(a)/D-5]
37Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -Legrand ] 6-32 A SP [ 7 / D- 6]
38Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make -Finolex/ RR Kabel / Polycabe /Havells or as per direction of EIC.) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish as per GS.Average run 8 mtr [2©/E-14] [For 4 Nos. Room EB 6, 14,15,17]
39Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe as per GS. Make -Finolex/ RR Kabel / Polycabe /Havells or as per direction of EIC 2x(2.5 sqmm)+1x(1.5 sqmm) [ 1(s) / E-9 ] [For Power Board]
402x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC [1(y)/E-9] [For SPNDB]
41Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 1.5sqmm
422.5sqmm [9 (i)/F-5]
434.0 Sqmm [9(ii)/F-5]
446 sqmm [9 (iii)/F-5]
45Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works as per GS. 20mm Size [7(a)/E-16]
4625mm Size [7(b)/E-16]
47Supply & Fixing 240 V, 2 nos. 6A, plug socket with separate 2 nos. 6 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 200x150x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required as per direction of EIC..
48Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connecte with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length as per GS [17/C-2]
49Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. as per G.S. [16/C-2]
50Supply of 4 Ft. single LED light fitting [ Make: Phillips, Model- TMC 502 1xT-LED 22W or Equivelent model of Crompton/Bajaj] complete with all accessories as per direction of EIC [With 3 years on site warrenty]
51Supply of 4 Ft. Double LED light fitting [ Make: Phillips, Model- TMC 502 2xT-LED 22W or Equivelent model of Crompton/Bajaj ] complete with all accessories as per direction of EIC [NS] [Analysis Attached] [With 3 years on site warrenty]
52S&D 20W LED T-8 lamp with polycarbonate housing & metal heat sink [Make: Phillips, Model- MAS LED tube 18W 2100 Lm 865 T8 ( Pc) or Equivelent model of Bajaj/Crompton ] as per direction of EIC. [With 3 years on site warrenty]
53Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works 200 mm x 150 mm x 65 mm [11(d)/E-4]
54Supply & Fixing bakelite / perspex top cover on existing Inspection board by Brass screws as per GS. 200 mm x 150 mm x 65 mm [13(d)/E-5]
55Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire as per GS. [21(a)/C-3]
56Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc. as per GS. [18(a)/E-6] Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe as to GS. Please Enable Macros to View BoQ information

Other Detail

Information Source https://wbtenders.gov.in/nicgep/app
Download FileName File Description File Size
Download 330747df-8c23-4024-9f45-edfb320363a9.html Tender Documents 0 KB
Download BOQ_2512526.xls Tender Documents 0 KB
Download Tendernotice_1 (5).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.