Indian Tenders

Tender Notice

TDR 54638882
Tendering Authority Public Works Department
Tender No WBPWD/EE/CED/eNIT-47/2025-2026
Tender ID 2026_WBPWD_1022045_1
Tender Brief Corrigendum : Tender For Urgent Replacement Of Old Unitary Air Conditioning Units Installed At Different Places Of Mjn Hospital Under Mjn Mc And H, Cooch Behar. (Electrical Work)
City Coochbehar
State West Bengal
Document Fees Refer document
EMD INR 8358.0 /-
Tender Value INR 4.17 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Urgent Replacement Of Old Unitary Air Conditioning Units Installed At Different Places Of Mjn Hospital Under Mjn Mc And H, Cooch Behar. (Electrical Work)

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 27-03-2026 DATE CORRIGENDUM Date 06-04-2026

Key Dates

Publish Date 27-03-2026
Last Date of Bid Submission 06-04-2026
Tender Opening Date 08-04-2026

Contact Information

Company Name Public Works Department
Contact Person Executive Engineer Cooch Behar Electrical Division
Address Executive Engineer Cooch Behar Electrical Division

BOQ Items

Name of Work:- Urgent replacement of old unitary Air Conditioning units installed at different places of MJN Hospital under MJN MC and H, Cooch Behar. (Electrical Work)
Sl. No. Item Description
1Sub Head----01 SITC SAC unit
2S&D of Concealed type split AC machine (a set of full metal body indoor and outdoor unit), having Cooling Capacity range (5.2 KW - 5.3 KW), with fixed speed rotary compressor, refrigerant gas R32/ R410A,, Air flow range CFM (560 - 600), both condenser and cooling coils made of copper tube, with P2 type capacitor, connecting chord with plug top, confirming to IS 1391 (Part-I & Part-II) with all amendments. Noise level not more than 52 db., suitable for1 Ph. 230V, 50 Hz. power supply. (Make - Mitsubishi Electric/ Daikin/ OGeneral/ Mitsubishi Heavy)
3S&D of Concealed type split AC machine (a set of full metal body indoor and outdoor unit), having Cooling Capacity range (6.6 KW - 7.0 KW), with fixed speed compatible rotary compressor, refrigerant gas R 32 / R 410A, Air flow range CFM (780 - 850), both condenser and cooling coils made of copper tube, with P2 type capacitor, connecting chord with plug top, confirming to IS1391 (Part-I & Part-II) with all amendments. Noise level not more than 52 db., suitable for 1 Ph. 230V, 50 Hz. power supply.(Make - Mitsubishi Electric/ Daikin/ OGeneral/ Mitsubishi Heavy)
4Installation, Testing & Commissioning of Indoor & Outdoor unit of the following capacity concealed type Split Air Conditioners after making hole in wall & necessary scaffolding arrangement etc as per site condition & direction of EIC including Supply of required Refrigerant as per the manufacturer specifications, S&F of necessary fixing arrangement for indoor duly painted etc as per direction of the EIC.
51.5/2 Tr
6Sub Head---02 Miscelleneous Items
7supply and drawing 5/8' & 1/4\\" copper refrigerant pipes with 9 mm thick nitrile rubber insulation along with other accessories, wrapping tape etc. on the surface of wall as per direction of EIC
8Supply and drawing copper communication & controlling cable of following size-4Core x 2.5 sq.mm copper cable (Make: Finolex / KEI / Polycab / Havells/ RR/Gloster)
9Supply & laying PVC Drain Pipe 25 mm dia with necy claming arrangement as per direction of EIC
10Sub Head----03 Grill Guard protection
11S & F iron cage ( 4O\\"x 36\\"x24\\" ) structure for the split AC machine ODUs on wall for holding and provide protection with locking arrangement & shade arrangement above the grills with corrugated tin shade, necessary anti-rust painting as per direction of EIC
12sub head- 04 EI work associated AC unit
13Supply & fixing of 240V, 50 Hz, 1ph OLP 3+ starter with digital display for split AC machine (1.5/ 2 TR) having rated current 21A, Voltage range 160-270 Volt having IP-20 protection and provision for display voltage, current & any fault indication (Make- Electron) incl. neccy. connection incl. supply material like wire, lugs etc. if required) and commissioning the same.
14Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc as to GS
15Supply & Fixing of 250V, 25A timer controlled single starter for controlling one no. room Air Conditioning Machine in SS double door 2+10 way DB enclosure (L&T / ABB / Legrand make) with S&F following electrical accessories & front door locking arrangement with all connections by finishing the ends of 2 x 4 & 1 x 2.5 mm2 copper wire with dowells solderless socket by crimping method as to GS, earthing attachment on wall incl. necessary connections as per direction of EIC : -
16i) 25A DP MCB (L&T / ABB / Legrand make) – 1 no.ii) 24Hr x 7 days programmable Digital timer (L&T make Cat no 67DDTO) – 1 no.iii) 3-pole power contactor (L&T make Cat no MNX22 / 250V) – 2no. [1W+1S units]
17iv) 3A SP MCB [for ON/OFF the Timer]-1no
18v) LED indication lamp (L&T/Legrand/Scneider) – 2 no.vi) Outgoing bakelite connector 32A (Reputed make as approved by EIC) – 2 nos.vii) with lock & key arrangement
19Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20/25 mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required
202 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC (for PB & RAC)
21Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. as per G S
224 sqmm
236 sqmm
24Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc as to GS
25Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.
26Hiring Charge of Scafolding Arrangements for installation of all the Indoor & Outdoor Units.
27Note: 1) All the above rates should be quoted inclusive of all taxes, duties and all ancilery charges with cost of maintenance, servicing, supply & replacement of spares for 1 (One) year from the date of commissioning. 2) Total is rounded off to the nearest rupees. Please Enable Macros to View BoQ information

Other Detail

Information Source https://wbtenders.gov.in/nicgep/app
Download FileName File Description File Size
Download 23e61316-a9c7-4b6a-8e60-69fee7e79ed4.html Tender Documents 0 KB
Download BOQ_2512010.xls Tender Documents 0 KB
Download Tendernotice_1 (5).pdf Tender Documents 0 KB
Download Tendernotice_2.pdf Tender Documents 0 KB
Disclaimer :