Indian Tenders

Tender Notice

TDR 54604086
Tendering Authority military engineer services
Tender No GE 874/EWS-02/2026-27
Tender ID 2026_MES_755835_1
Tender Brief Corrigendum : Tender For Civil Work, Provision Of Certain Minor And Revenue Works At Trehgam, Panzgam, Niyari, Zangli And Tangdhar Under The Aor Of Ge 874 Ews.
City Kupwara
State Jammu and Kashmir
Document Fees INR 500 /-
EMD INR 97200.0 /-
Tender Value Refer document
Tender Type Works
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender For Civil Work, Provision Of Certain Minor And Revenue Works At Trehgam, Panzgam, Niyari, Zangli And Tangdhar Under The Aor Of Ge 874 Ews.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 01-04-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 08-04-2026
2 23-03-2026 Amdt in Notice of Tender Other 01-04-2026
3 23-03-2026 Amdt in Notice of Tender Other 08-04-2026

Key Dates

Publish Date 23-03-2026
Last Date of Bid Submission 08-04-2026

Contact Information

Company Name military engineer services
Contact Person GE 874 EWS
Address GE 874 EWS Kupwara

BOQ Items

Name of Work:- PROVN OF CERTAIN MNNOR AND REVENUE WORKS AT TREHGAM, PANZGAM, NIYARI, ZANGLI AND TANGDHAR UNDER THE AOR OF GE 874 EWS.
Sl. No. Item Description
1Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in any type of soil complete all as specified and directed.
2Excavation in trenches n exc 1.5m wide and n exc 1.5m in depth for foundation etc n exc 10 sqm on plan and getting out in any type of soil complete all as specified and directed.
3Returning filling in including spreading levelling watering and well ramming in layers n exc 25cm complete all as specified and directed.
4Removal of excavated materials n. exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
5M & L PCC 1:4:8 type D-2 in foundation, filling and mass concrete (using 40 mm graded crushed stone aggregate) complete all as specified and directed.
6M & L PCC 1:3:6 type C-2 in foundation, filling and mass concrete (using 40 mm graded crushed stone aggregate) complete all as specified and directed.
7M & L for 100mm thick cement concrete type D-2, 1:4:8 (40 mm graded aggregate) as in sub bases complete all as specified and as directed.
8M & L for sand cushioning under floors or in foundations including watering and consolidation complete all as specified and as directed.
9M &L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-50 Grade with grey cement and pigments complete all as specified and as directed.
10M&L for brick work with sub class 'B' brick straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
11S&F mild steel as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to Fe410-W (Grade E-250) quality A complete all as specified and directed.
12S&F mild steel work as in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade Fe410-W (Grade E-250) quality A complete all as specified and directed.
13S&F mild steel work as in Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe410-W (Grade E-250) quality A complete all as specified and directed.
14S&F mild steel screw bolts (machine made),16-20 mm dia, with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 15cm and n exc 22.5cm long complete all as specified and directed.
15S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with tapping screws complete all as specified and directed.
16S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with tapping screws complete all as specified and directed.
17M&L hardcore (broken stone or boulders) of gauge n exc 63 mm deposited spread and levelled in layers n exc 15 cm thick watered and rolled / rammed to a true surface complete all as specified and directed.
18M&L for providing, cement concrete type B-0 (1:2:4) (using 12.5mm graded crushed stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed.
19M& L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick / concrete/stone, surfaces and finished even and smooth without using extra cement mixed with WPC @ 3% by Wt. of cement (External surfaces) WPC shall be measured and paid separately) complete all as specified and directed.
20Supply only approved integral water proofing compound complete all as specified and directed.
21M & L for preparing new surfaces of walls and applying two coats of cement base paint over one coat of white wash complete all as specified and directed.
22M&L for two coats of synthetic enamel paint over one coat of red oxide exc 10cm width or girth on newly prepared steel surfaces complete all as specified and directed.
23M&L for PCC 1:2:4 type B-1 using 20mm graded aggregate as in surface channel and drain complete all as specified and directed.
24M&L for rendering 15mm thick on fair faces of brick/stone or concrete surfaces in CM 1:4 and finished even and smooth without using extra cement (internal surfaces) complete all as specified and directed.
25M & L for rendering 15mm thick on other than fair faces of brick work or concrete surfaces in CM 1:4 finished over and smooth w/o using extra cement mixed with water proofing compound complete all as specified.
26Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/ stopped ends etc complete all as specified and directed.
27M & L for use and waste of formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pilasters, buttresses, etc.; vertical or to batter complete all as specified and directed.
28M&L for use and waste of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
29M&L for RCC 1:2:4, type B-1(Nominal mix) using 20 mm graded crushed aggregate as in slab supported on walls, beams and column in floor roof, landings , balconies, canopies , deck slab and in shelves etc. complete all as specified and directed.
30M&L MS TMT bars 10mm dia and over cut to length, bent to shape required incl. cutting, cranking, hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia complete all as specified and directed.
31S&F reinforced concrete pipes of 300mm dia, class NP3, laid and jointed complete including packing under and haunching against the sides of pipe after they are laid and tasted complete all as specified and directed.
32M&L for cement concrete bed to drain pipes in cement concrete 1:3:6 type C-2 for class NP 3 of dia 300mm including packing under and completely surrounding pipes with concrete after they are laid and tested in complete all as specified and directed.
33Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. Brushing neat cement slurry with 3.0kg of cement per sq. metre complete all as specified and directed.
34M&L 75 mm thick PCC 1:4:8 type D2 using 40 mm graded aggregate as in sub base complete all as specified and directed.
35M&L for 25mm thick PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate as in floor finished even and rough to receive the topping layer complete all as specified and directed.
36M&L for machine cut Kota stone slab flooring 18-20mm thick over screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete and including 15mm thick screed bed in CM 1:4 complete all as specified and directed.
37M&L for Kota stone slab 18-20mm thick in riser of steps, skirting, dado and pillar laid and jointed over and including 10mm screed plaster in CM 1:4 complete all as specified and directed.
38M&L for rounding to edges of stone/Kota/marble slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed.
39Taking down cement plaster on brick walls etc, including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
40M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in CM 1:6 and finished even and smooth without using extra cement complete all as specified and directed.
41M&L for preparation of old plastered surface of wall and applying one coats of cement based paint complete all as specified and as directed
42M&L for preparation of new plastered surfaces of wall and applying two coats of white wash complete all as specified and directed.
43M & L for point wiring One light /one fan/one bell point controlled by one switch, with PVC insulated unsheathed single core multistranded copper conductor 1.5 sqmm, 1100 volts grade cable, FRLS, drawn through PVC casing caping including accessories and provision of PVC boxes for mounting switches, switch socket, fan regulator, provision of modular Teressa plate Irene stripes, No of modules as required on site or as directed by Engineer-in-Charge including one run of PVC insulated unsheathed multistranded copper conductor cable 1.5 sqmm (green colour) earth wire and connected to earth dolly complete all as specified and directed.
44All as per Item No 43 above but point wiring for One socket outlet 5 pins 5 amps controlled by one switch on same board.
45All as per Item No 43 above but point wiring One socket outlet 5 pins 5 amps controlled by one switch on independent board.
46All as per Item No 43 herein before but wiring with 2.5 sqmm copper wire (FRLS) and 2.5 sqmm earth wire for socket outlet 6 pin 15 amps on independent board.
47S&F switch piano flush button single pole, one way 5 amps complete all as specified and directed.
48S&F socket outlet multi 5 pins 6 amp, complete all as specified and directed.
49S & F switch socket combination 2 in 1, 6A flush type complete all as specified and directed.
50S & F switch socket combination 3 pin 16A, flush type complete all as specified and directed.
51S&F ceiling rose, PVC/poly carbonate, isolated body three terminal complete all as specified and directed.
52Supply and fixing in replacement LED warm lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
53S&F sheet metal enclosure for DBs (double door type) when MCBs to be used single pole and neutral 4 way including blanking plate as required with 200 amps rated busbar 240V, fixed sunk/flush to the wall complete all as specified and directed.
54S&F MCB single pole & neutral 40 to 63 Amps 230 Volts 'C' series, 10 KA complete all as specified and directed.
55S&F MCB's single pole 240 volts 6 to 32Amps 10 KA 'C' series, complete all as specified and directed.
56Supply and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathed of PVC tape overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, including service bracket for incoming through one twin core cable of size 16 Sqmm complete all as specified and directed.
57M&L for earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0 mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 03 of 2009 SSR Pt-I and testing on complete including earth work in any type of soil, PCC 1:2:4 type B-0 as in earth pit and cover 40mm thick reinforced with XPM (weight not less than 4.0Kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, common salt, charcoal and testing on completion all as specified and directed.
58Supply, Installation testing and commissioning of Centralised Water Heater Facility with Water Heating Plant of Capacity 500 LPH, capable of heating 500 litres of water at 2 degrees Celsius to 50 degrees Celsius in 40 minutes (or 65 degrees, as required at site. But when 65 degrees Celsius is required, then time may be more for heating), with puffed glass wool/ polyurethane insulation
59(of thickness and density as directed at site by Engineer-In-Charge) over the boiler, boiler tank and pipelines, all covered with aluminium cover, digital temperature controller, electronically controlled burner, water temperature gauge, nylon braided fuel pipes, flue gas chimney and exhausts (insulated with POP ropes), fuel boiler, fuel level indicator, fuel burner, capable of running in Kerosene and Diesel, boards (for instructions, caution and installation names), necessary electrical wiring, necessary GI Gate valves, GI fittings and GI medium grade pipes (of any length and bore (from existing tank to boiler, from boiler to lower tank and from lower tank to upper tank, from upper tank to bathrooms) complete all as required at site) including polyurethane (covered with aluminium sheet and nylon cable ties) lagging as directed at site by Engineer-In-Charge.
60Including one set of beacons (to indicate plant running) and including a control panel with over current, over voltage protection circuits, Ampere meter, Voltage meter, power factor meter, all with 24 month AMC (all included warranty). Any other necessary fittings, accessories and infrastructure required shall also be provided by Contractor, as per site requirement complete all as specified and directed. The equipment shall have tolerance for any soil/ dirt/ water in fuel as applicable in field conditions in Army locations in Kashmir valley. In case of any doubt regarding electrical and plumbing requirement, the direction of GE shall be final.
61Material, Hoisting, Fixing and Labour for Rotational moulded polyethylene water storage tank/fuel storage tank of capacity of 500 litres (cuboidal (or cylindrical if approved by engineer in charge) vertical with closed top), for hoisting into position either inside or outside of building, connecting up pipes, securing access covers etc., with monkey-proofing mechanism, hoisted and fixed in position all as specified in SSR Part I
62Supply and fixing analogue/ digital temperature gauge (for measurement of temperature in water tank), IP67 rated, rainproof and snow proof, with separate sensor and gauge fixed upto 1.5 meters away complete all as specified and directed.
63Supply and Fixing single phase voltage stabiliser (copper wound) with variation in input between 90V to 300 V and stabilised output at 230 V, of 5 KVA capacity (or any other higher capacity to run all equipment of the contract), with over current and over voltage protection, complete all as specified and directed.
64Excavating in post holes (or similar holes) each n exc 0.5 cum as in soft /loose soil getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
65M&L for Plain Cement Concrete type B-2, 1:2:4 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete, complete all as specified and directed.
66M & L for Hardcore of gauge exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and directed.
67Material and Labour for fixing ibid tank with a head of 2 meters above the roof of the highest bathroom for which the heater pipes are provided, either by having a staging from ground level or by making suitable modifications in the walls of the building, including any RCC concrete, Brick work, structural steel work, cover for tank, plastering work, welding work or any other work required, complete, all as specified, clarified and directed by engineer in charge
68Supply and Fixing, Single Phase, electric motor water pump, with separate starter, self priming type, with 25 meter head, 0.5 HP (or any other higher capacity as required), for pumping hot water, complete with all plumbing and electrical fittings, complete all as specified and directed.
69Supply and install auto switch on and Switch off mechanism for above motor pump (based on sensors in upper tank and lower tank), IP67 rated, with all necessary electrical, electronic and mechanical fittings, complete, all as clarified, complete all as specified and directed. The controller shall have system to protect motor when lower tank is dry and correspondingly avoid dry running of motor.
70Material and Labour for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof overing/cladding to wall, fixed with self tapping screws complete all as specified and directed.
71Material and Labour for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof overing/cladding to wall, fixed with self tapping screws complete all as specified and directed.
72Material and Labour for mild steel framed work such as grills, gratings, etc.. with ends of tubular bars shouldered and/or riveted, or bolted, or welded, or forged for shed structure / water staging, conforming to Fe.290.Gde-E-165, painted in Olive Green/ MES Blue Colour complete all as specified and directed.
73Supply & Fixing 3-layer PP-R P o l y p r o p y l e n e random copolymer) concealed pipes 25mm dia SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded p o l y p r o p y l e n e random fittings fixed complete to walls, ceilings or in floors etc complete all as specified and directed.
74Material & Labour for Lagging to pipes of 25mm bore used in internal/External water supply or plumbing all round with, 25min thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842 Complete all as specified and directed by Engr-in-Charge.
75Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including making connection as required including PVC conduit pipe 20mm dia for protection of cable from Junction box to GI bracket complete all as specified and directed. Note : PVC conduit and connection cable will be paid and measured separately.
76Supply and fix street light control junction box 200x160x98mm made out of thermoplastic and arrangement of incoming 3 phase 4 wire system and out going 3 phase 4 wire system with R.Y.B.& N studs and control for incoming & outgoing cables with MCB SP 6 Amps 230 volts with neutral link including flat iron 25x3 mm “D” clamps (2 Nos) suitable to pole of any size with bolts nuts & washers complete all as specified. Note: - The unit rate quoted shall be deemed to includes for incoming & outgoing cables glands & lugs complete all as specified and directed.
77S & F bracket suitable for street light fitting made out of 40mm dia GI tubing light grade 1.5m long bent to shape, fixed with necessary nuts bolts and clamps of size 32X6mm, including silver paint to bracket complete all as specified and directed.
78Supply & fixing multistranded Copper Conductor cable of 3 Core 2.5 Sq mm for connection of lights from junction box to light complete all as specified & directed.
79S&F Rigid PVC conduit of 20 mm dia exclusive of boxes (junction/terminal) but inclusive of all fixing accessories such as couplers, locknuts, saddles, pipe, hooks etc with steel tubular pole, for pvc wire protection from junction box to LED light fitting complete all as specified and directed.
80Supply and fixing LED flood light 70 watt, 230 Volt AC, outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including mounting/fixing arrangement complete all as specified and directed.
81M&L for Sand cushioning to underground cables 8 cm below the cable before laying and 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Part-I, complete all as specified and directed.
82Material and labour for kiln burnt Sub class 'B' bricks laid dry flat, width wise along the length of cable in trenches after sand cushioning for protection of under ground cable complete all as specified and directed.
83S & F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, 3.5 core 120 sqmm cross sectional area in trenches or walls complete all as specified and as directed. Note: for SI Nos 81 to 83 : Excavation & Earth work sand cushioning GI Pipe and brick for cable protection will be measured and paid separately.
84All as per item No. 81 above but 3.5 core 50 Sqmm
85All as per item No. 81 above but 3.5 core 35 Sqmm
86Supply, assembly, erection, testing and commissioning of Electrical panel cubical outdoor type powder coated with 8/7 tank process suitable for operation on 3-phase + N + E, 415V, 50 Hz, AC with internal arc containment, internally pre-wired with copper conductor factory fabricated as per CPRI approved make specified in CA, floor mounted free standing made out of 3.15mm thick CRCA sheet, and shall be compartmentalised with rubber gasketed hinged door having front and rear opening for installation of separate cable alleys, bus bar chamber and switch gear compartments, dust and vermin proof duly powder coated with aluminium bus bars 800A capacity for phases and neutral, set of three LED indicating lamps with base, air ventilation to be provided for heat dissipation, suitable sized knock out holes for cable glands shall be provided, with and including provision of the following switch gears, including suitable size of necessary PCC (1 : 3 : 6) type C2 as in foundation complete all as specified and directed.
87a) Aluminium Bus bar 800 Amps capacity TPN, full for phase and neutral with colour code PVC sleeves. - 01 Job
88b) LED RYB indicating lamps – 01 set
89c) LED Ammeter and voltmeter witn necessary CTs and display of required rating .
90d) MCCB 400Amp, 36KA TPN, 415 Volts - 1 Nos (Incomer)
91e) MCCB 250Amp, 36 KA TPN, 415 Volts - 01 Nos (Out going)
92f) MCCB 160Amp, 18KA TPN, 415 Volts - 03 Nos (Out going)
93g) Panel wiring with PVC Insulated un sheathed single core, 1100 Volts grade cable with copper conductor, multi stranded of suitable size. - 01 Job
94h) Interconnection of busbar with MCCB, contactor with suitable size aluminium strip - 01 Job
95j) Provisioning of cable glands and cable lugs for all incoming and out going cables & connecting the earthing to an earthing test point to main switch board as specified and testing on completion complete all as specified & directed by Engr-in-Charge. - 1 Job
96Supply and fix of off load changeover switch AC, 4 pole, 415 volt upto 400 Amp complete all as specified and directed. Please Enable Macros to View BoQ information

Other Detail

Information Source https://defproc.gov.in/nicgep/app
Download FileName File Description File Size
Download 02TENDER.pdf Tender Documents 0 KB
Download 2229ce88-d08b-4f42-b4c5-6eb66da848a4.html Tender Documents 0 KB
Download BOQ_846604.xls Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.