|
| 1 | (1) Improvement of Vivekananda Road Lane No-27 with RCC Cover Drain, starting from Dinendra Purkayastha house to RCC Bridge, Clearing and Grubbing road land including uprooting wild vegetation ,grass,bushes,shrubs,saplings and trees of girth upto 300m,removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned ,upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150mm in thickness as per T.S clause 201.(i) By Manual Means (B)(b) In area of thorny jungle |
| 2 | Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5(I) Private Land |
| 3 | Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC and compacting with smooth wheel roller to achieve the desired density, complete as per Clause 401,II) For Grading II Material |
| 4 | Providing and fixing retro reflectorised cautionery, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75mmx 75mmx 8mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concreyte 450mmx450mmx600mm below ground level as per drawings and technical specification Clause 801. 800mm x 600mm rectangular |
| 5 | Providing and fixing of typical informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 |
| 6 | Utility shifting |
| 7 | RCC Rectangular Drain Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.I. In Ordinary soil (i) Upto 3 m depth |
| 8 | Providing Providing concrete for plain/ reinforced concrete in open foundation complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203. A With crushed Stone ( II). PCC Grade M15 Nominal mix 1:2.5:5. |
| 9 | Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/ Esser Steel/ Jindal steel/Shyam steel/RINL) in foundation complete as per drawings and technical specifications Clauses 1000 and 1202 |
| 10 | Providing plain/reinforced concrete in Sub Structure complete as per drawings and technical specifications Clause 802, 804,805,806,807, 1202 & 1204. A. With crushed Stone IV R.C.C Grade M20 Nominal mix (1:2:4) |
| 11 | Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. |
| 12 | Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 |
| 13 | (2) Improvement of Baidik Township Chincoorie Road Clearing and Grubbing road land including uprooting wild vegetation ,grass,bushes,shrubs,saplings and trees of girth upto 300m,removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned ,upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150mm in thickness as per T.S clause 201.(i) By Manual Means (A)In area of non thorny jungle. |
| 14 | Construction of Embankment with Material Obtained from Borrow Pits.Construction of embankment with approved materials obtained from borrow pits with a lift upto 1.5 m transporting to site spreading grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5.(i) Private Land. |
| 15 | Construction of Subgrade and Earthen Shoulders. Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads transporting to site spreading grading to required slope and compacted to meet requirement of Table 300.2 with upto 1000 m as per Technical Specification Clause 303.1 (i) Private Land |
| 16 | Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (ii) For Grading II Material |
| 17 | Providing laying spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness hand packing rolling with three wheel 80-100 kN static roller in stages to proper grade and camber applying and brooming stone screening/binding materials to fill up the interstices of coarse aggregate watering and compacting to the required density Grading 3 as per Technical Specification Clause 405 . 3) WBM Grading -III Using stone screening Type-B 11.2 mm for Gr.III (A) By Manual Means |
| 18 | Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per echnical specification clause 1504 including carriage.a) including Edge block/Edge restraints |
| 19 | Providing and fixing of retro-reflectorised cautionary mandatory and informatory sign as per IRC:67 made if encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over alluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm 600 mm below grounded level as per drawings and Technical Specification Clause 801. 600 mm equilateral triangle |
| 20 | Providing and fixing of retro-reflectorised cautionary mandatory and informatory sign as per IRC:67 made if encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over alluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm 600 mm below grounded level as per drawings and Technical Specification Clause 801. 800mm x 600mm rectangular |
| 21 | Providing and fixing of typical informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 |
| 22 | Utility Shifting |
| 23 | (3) Improvement Maa Kali Lane, Ashram Road, (Construction of Retaining Wall) & Construction of 2x5x5 Box Culvert at Padmini Lane, Ashram Road Maa Kali Lane, Ashram Road RCC Retaining Wall with RCC Pile Earth work in excavation for structureas as per drawing and technical specification Cl;305.1 , including setting out, construction of shoring and bracing,removal of stumps and other deleterious materials and disposal upto a lead of 50 m, dressing of sides and bottom and back filling in tranches with excavated suitable materials.Ordinary soil(i)Up to 3.00m depth. |
| 24 | Bored cast-in-situ M25 grade R.C.C. pile excluding reinforcement complete as per drawing and technical specifications nd removal of excavated earth with all lifts and lead upto 1000 m. (Pile diameter-400 mm)(Manual means) |
| 25 | Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in foundation complete as per drawings and technical specifications Clauses 1000 and 1202 |
| 26 | Providing concrete for plain/reinforcement concrete in open foundations complete as per drawings and technical specifications clause 802, 803, 1202 & 1203.(B)With Natural Gravel (I) P.C.C. grade M 10 Nominal mix 1:3:6 |
| 27 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification.(B)With Natural Gravel (III) R.C.C. grade M 20 (i) for height upto 5m |
| 28 | Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 |
| 29 | Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 |
| 30 | Back filling behind abutment, wing wall & return wall complete as per drawings and technical specifications. Clause 1204.3.8 (i) Granular Material |
| 31 | Utility Shifting |
| 32 | Padmini Lane, Ashram Road Construction of 2x5x5 Box Culvert Bamboo Piling below Box cell under PCC for marshy soil (Analysis rate as per approved estimate and drawing) |
| 33 | Double Cell 2X5mX5m Box Cell Culvert Earthwork in excavation for structures as per drawing and technical specifications Clause305.1 including setting out, construction of shoring and bracing, removal of stumpsand other deleterious material and disposal upto a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Marshy Soil |
| 34 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803,1202 & 1203With crushed StoneP.C.C grade M 10Nominal mix 1:3.6 (Hand mixing) |
| 35 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawing and technical specification Clause 802, 803, & 1203IV) R.C.C.grade M 20 |
| 36 | Providing concrete for plain / reinforced concrete in foundations complete as per drawings and technical specifications Clauses 802, 803, 1202 & 1203PCC Grade M 20Nominial mix (1:2:4) (Hand Mixed) |
| 37 | Providing concrete for plain / reinforced concrete in substructure complete as per drawings and technical specifications Clauses 802, 804, 805, 806, 1202 & 1204 RCC Grade M 20 i) For height upto 5 m |
| 38 | Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing |
| 39 | Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5. R.C.C grade M 20 i For nominal mix 1:2:4b) Height from 5m to 10M |
| 40 | Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and technical specification Clauses 615, 710 and 1204.3.11With Crushed stone |
| 41 | Supplying, fitting and placing TMT (Fe-500D) reinforcement bar (From Primary Producer: TATA/SAIL/EsserSteel/Jindalsteel/Shyamsteel/RINL) in foundation complete as per drawings and technical specifications Clauses 1000 and 1202 |
| 42 | Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 |
| 43 | Supplying, fitting and placing TMT (Fe-500D) reinforcement bar . (From Primary Producer:TATA/SAIL/EsserSteel/Jindalsteel/Shyamsteel/RINL)in Primary Producer: TATA/SAIL/Esser Steel/Jindal steel/ Shyam steel/ RINL) in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202 |
| 44 | Filling in foundation trenches as per drawing and technical specification Clause 305.3.9 Earth Filling (marshy Soil) |
| 45 | Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3 |
| 46 | Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8I Granular material |
| 47 | Construction of Embankment with Material Obtained from Borrow Pits Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 |
| 48 | Gabion Wall with Boulder in Crates Excavation for StructuresEarthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.Ordinary soilUpto 3 m depth |
| 49 | Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302 |
| 50 | Providing and laying wire created boulder structures boulder size 22.5 cm to 45 cm having 25 kg average weight for each i/c dumping/laying in S.W.G. Wire mesh of 10 cm x 10 cm (woven diagonally) 4mm dia i/c packing with small size stone spalls and carrying of boulders from a lead of 50 mtr and lift up to 1.5 mtr i/c lying properly the mesh by cutting the mouth and hoisting of wire where felt necessary as per direction of Engineer-in-Charge technical specifications Clause 1301. |
| 51 | Providing and fixing of retro-reflectorised cautionary mandatory and informatory sign as per IRC:67 made if encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over alluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm 600 mm below grounded level as per drawings and Technical Specification Clause 801. 600 mm equilateral triangle |
| 52 | Providing and fixing of retro-reflectorised cautionary mandatory and informatory sign as per IRC:67 made if encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over alluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm 600 mm below grounded level as per drawings and Technical Specification Clause 801. 600 mm circular |
| 53 | Providing and fixing of retro-reflectorised cautionary mandatory and informatory sign as per IRC:67 made if encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over alluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm 600 mm below grounded level as per drawings and Technical Specification Clause 801. 800mm x 600mm rectangular |
| 54 | Providing and fixing of typical informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 |
| 55 | Utility shifting Please Enable Macros to View BoQ information |