Indian Tenders

Tender Notice

TDR 54571271
Tendering Authority Indian Oil Corporation Limited
Tender No 9070C26A74
Tender ID 2026_PDR_189248_1
Tender Brief Corrigendum : Tender For Structural Repair Of Piles At South Oil Jetty (Soj) Paradip Refinery.
City Paradip
State Odisha
Document Fees Refer document
EMD INR 118000.0 /-
Tender Value INR 3.99 Crore /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Structural Repair Of Piles At South Oil Jetty (Soj) Paradip Refinery.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 05-05-2026 Extension-05 Date 12-05-2026
2 28-04-2026 Extension-04 Date 04-05-2026
3 28-04-2026 Extension-04 Date 04-05-2026
4 20-04-2026 Corrigendum-GCC Other 27-04-2026
5 20-04-2026 Extension-03 Date 27-04-2026
6 20-04-2026 Corrigendum-GCC Other 04-05-2026
7 20-04-2026 Corrigendum-GCC Other 12-05-2026
8 20-04-2026 Extension-03 Date 27-04-2026
9 09-04-2026 Corrigendum-01 Other 27-04-2026
10 09-04-2026 Corrigendum-01 Other 04-05-2026
11 09-04-2026 Corrigendum-01 Other 12-05-2026
12 07-04-2026 Extension-02 Date 21-04-2026
13 07-04-2026 Extension-02 Date 21-04-2026
14 07-04-2026 Extension-02 Date 21-04-2026
15 25-03-2026 Extension-01 Date 08-04-2026
16 25-03-2026 Extension-01 Date 08-04-2026
17 25-03-2026 Extension-01 Date 08-04-2026
18 25-03-2026 Extension-01 Date 08-04-2026

Key Dates

Publish Date 05-05-2026
Last Date of Bid Submission 12-05-2026
Tender Opening Date 13-05-2026

Contact Information

Company Name Indian Oil Corporation Limited
Contact Person DGM(Contracts)
Address Indian Oil Corporation Limited, Paradip Refinery, PO- Jhimani, Via-Kujang, District-Jagatsinghpur, Odisha-754141, Tel No. - 06722- 255371

BOQ Items

Name of Work:- Structural Repair of Piles at South Oil Jetty (SOJ) Paradip Refinery.
Sl. No. Item Description
1SOJ Pile repair
2\\"Execution of Repair job of piles as the methodology mentioned as below. Step 1: Fix the Surface applied SRM TM Seamless Annular Shell Form (which is a high-performance Glass Fiber Reinforced Polymer (GFRP) annular forming laminate designed for creating a continuous, staying place, seamless external jacket around existing piles, columns, and similar vertical structural elements to be repaired or strengthened using suitable underwater epoxy adhesive and spacers as per site requirement. )over the prepared area of concrete section to be jacketed and cast it with Micro-concrete underwater to form a base collar ring along the periphery. Step 2: FIX SRM AF SPACERS at required Spacing in both directions and in plumb on the face of pier (also provide shear key and distribution steel bars wherever required in both directions. Step 3: Lower and fix the slide in high strength noncorrosive sacrificial SRM Annular Form Sheets in the spacers and fix it; after complete installation tie all of them together with annular tie bands for enhanced rigidity during casting. Step 4: Mixing the underwater Micro concrete and fill the same using the inlet point provided in SRM patch Form frame or pouring it in SRM Seamless Annular Shell with micro tremie pipes for better reach (for larger depths SRM Annular Form to be provided with Inlet ports for pouring Micro concrete). Use material with suitable consistency for underwater works. observe the fill through transparent window provided in form. Step 5: Allow to cure and carryout an underwater (after repair and retrofit works) inspection with photography and videography of repair , all complete as per direction of Engineer-In-charge The rate is inclusive of all consumables, materials , labours , Tool tackles, Transportation , Lodging etc. involved. The unit of measurement is in Sqm ( The Repaired area will be considered for measurement)\\"
3\\"Execution of Repair job of piles as the methodology mentioned as below. Step 1: Removal of the highly corroded steel liners Step 2: Fix the Surface applied SRM TM Seamless Annular Shell Form (which is a high-performance Glass Fiber Reinforced Polymer (GFRP) annular forming laminate designed for creating a continuous, staying place, seamless external jacket around existing piles, columns, and similar vertical structural elements to be repaired or strengthened using suitable underwater epoxy adhesive and spacers as per site requirement. )over the prepared area of concrete section to be jacketed and cast it with Micro-concrete underwater to form a base collar ring along the periphery. Step 3: FIX SRM AF SPACERS at required Spacing in both directions and in plumb on the face of pier (also provide shear key and distribution steel bars wherever required in both directions. Step 4: Lower and fix the slide in high strength noncorrosive sacrificial SRM Annular Form Sheets in the spacers and fix it; after complete installation tie all of them together with annular tie bands for enhanced rigidity during casting. Step 5: Mixing the underwater Micro concrete and fill the same using the inlet point provided in SRM patch Form frame or pouring it in SRM Seamless Annular Shell with micro tremie pipes for better reach (for larger depths SRM Annular Form to be provided with Inlet ports for pouring Micro concrete). Use material with suitable consistency for underwater works. observe the fill through transparent window provided in form. Step 6: Over water level or in splash zone, apply abrasion (erosion) resistant FRCM system (Fibre Reinforced Cementitious Matrix) mainly on the upstream sides of pier highly prone to erosive forces. Step 7: Allow to cure and carryout an underwater (after repair and retrofit works) inspection with photography and videography of repair , all complete as per direction of Engineer-In-charge The rate is inclusive of all consumables, materials , labours , Tool tackles, Transportation , Lodging etc. involved. The unit of measurement is in Sqm ( The Repaired area will be considered for measurement)\\"
4MICRO-CONCRETING: Providing and placing in position Micro-concrete as per relevant ASTM / BS/ IS having Compressive Strength of minimum 45 Mpa (M-45) at 28 days, of make PIDILITE / BASF/ SIKA/ FOSROC or equivalent in columns, beams, slabs etc. which shall be pre-packed single component, chloride free, non- shrink, free flow, self compacting and mixed as per manufacturer's specification, including required leak proof shuttering, pre-soaking of substrate, manual application or pumping, manpower and tools and tackles all complete as per direction of the Engineer-in-Charge.
5Providing & applying anti-carbonation coating (high performanceelastomeric) in 2 coats over one coat OF DEEP penetrating primer ofapproved brand quality and specification provided in the tender. MAKE :Pidilite, BASF, FOSROC, SIKA, CICO, PAREX or equivelent. Please Enable Macros to View BoQ information

Other Detail

Information Source https://iocletenders.nic.in/nicgep/app
Download FileName File Description File Size
Download ALL_TENDERDOCS.rar Tender Documents 0 KB
Download Bidders_help_Document_for_1.pdf Tender Documents 0 KB
Download BOQ_199513.xls Tender Documents 0 KB
Download CommonDocs.rar Tender Documents 0 KB
Download f36d1406-b8db-4ab1-9c94-bce23463d99d.html Tender Documents 0 KB
Download FAQs-IOCL-Online-EMD.pdf Tender Documents 0 KB
Download Special_Instructions_to_t_2.pdf Tender Documents 0 KB
Download TCBID.pdf Tender Documents 0 KB
Download Tender-Acceptance-Format.pdf Tender Documents 0 KB
Download Tendernotice_1 (3).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.