Indian Tenders

Tender Notice

TDR 54569503
Tendering Authority Jharkhand Police Housing Corporation Limited
Tender No JPHCL/GR 02/NIT 08/2025-26
Tender ID 2026_JPHCL_111065_1
Tender Brief Corrigendum : Tender For Construction Of 100 Bedded Barrack At Jap- 08, Lesliganj In The District Of Palamu.
City Palamu
State Jharkhand
Document Fees INR 10000 /-
EMD INR 739000.0 /-
Tender Value INR 3.69 Crore /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Construction Of 100 Bedded Barrack At Jap- 08, Lesliganj In The District Of Palamu.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 24-03-2026 Date Corrigendum Date 08-04-2026

Key Dates

Publish Date 24-03-2026
Last Date of Bid Submission 08-04-2026
Tender Opening Date 10-04-2026

Contact Information

Company Name Jharkhand Police Housing Corporation Limited
Contact Person Chief Engineer
Address Jharkhand Police Housing Corporation Limited Line Tank Road Ranchi 834001

BOQ Items

Name of Work:- Construction of 100 Bedded Barrack at JAP- 08, Lesliganj in the district of Palamu.
Sl. No. Item Description
1Section-I Building Work
2Earth work in excavation in foundation trenches in ordinary soil(vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I.
3Extra for earth work in hard soil as per specification and direction of E/I.( vide classification of soil item B)
4Filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume)
5Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
6Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
7Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :5.3.1.31:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size)
8Providing designation 75A brick work in C.M (1: 6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I.
9Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level.5.3.9.11:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)IN FOUNDATION
10Centering and shuttering including strutting, propping etc. and removal of form for Centering and shuttering including strutting, propping etc. and removal of form for
11Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
12Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
13Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :5.3.1.11:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)Plinth Band
14Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
15Reinforced cement concrete work in beams,Slab,lintel,etc suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
16Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
17Reinforced cement concrete work in beams,Slab,lintel,etc suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
18Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
19Reinforced cement concrete work in beams,Slab,lintel,etc suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
20Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
21Reinforced cement concrete work in beams,Slab,Lintel Band,etc suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
22Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform in Lintel Band
23Reinforced cement concrete work in beams,Slab,lintel,etc suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
24Centering and shuttering including strutting, propping etc. and removal of form for Stairs, (excluding landings) except spiral-staircases
25Reinforced cement concrete work in beams,Slab,lintel,etc suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
26Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges
27Reinforced cement concrete work in beams,Slab,lintel,etc suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
28Centering and shuttering including strutting, propping etc. and removal of form for Shelves (Cast in situ)
29Exra for adddition Hight in centering, shuttering where ever required with adequate bracing, propping etc. , including cost of deshuttering and at all levels, over a height of 3.5 m, for every additional height of 1metre or part there of (plan area to be measured)Suspended floors, roofs, landing, beams and balconies (plan area to be measured)
30Providing designation 75 A brick work in C.M. (1: 6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
31Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x3\\") in CM (1:6) in super structure with approved quality of Clean coarse sand of F.M 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening materials raking our joints to 15 mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
32Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I
33Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scafolding taxes and royalty all complete as per buildings specification and direction of E/I.
34Extra for brick work for each consecutive floor above first floor including watering and scaffolding, all complete as per direction of E/I.
35( a) For S.F.
36From 250 mm B/W in S/S item \\"C\\" &\\"D\\"
37Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for each four floors or part thereof.
38( a) For S.F. Total RCC in 2nd Floor
39Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
40Providing reinforecment ( Round bars conforming to I.S 432 dia in mm ( I.S 2062 Gr.A ) to 6 &8 mm dia rods as per approved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire, removal or rust placing the rods in position all complete as per building specification and direction of E/I. (i) 6mm dia Gr. A ( Only Valid for SAIL & TATA Steel )
41Providing TMT steel reinforcement of 8 mm dia rods as per approved design and drawing excluding carriage of Rods (straight or in coils) to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position complete as per building specification and direction of E/I.
42Providing TMT Steel reinforcement of 10mm, 12mm & 16mm dia bars as per approved design and drawing excluding carriage of M.S. Rods (straight or in coils) to work site, cutting bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I
4310 mm dia (TMT Fe 500 (Only valid for SAIL & TATA Steel )
4412 mm dia (TMT Fe 500 (Only valid for SAIL & TATA Steel ) 16 mm dia (TMT Fe 500 (Only valid for SAIL & TATA Steel ) Providing TMT steel reinforcement of 20 mm & 25mm dia, bars as per approved design and drawing excluding carriage of M.S. Rods (straight or in coils) to work site, cutting bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/I. (TMT Fe 500 (Only valid for SAIL & TATA Steel )
45Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flats as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, hoisting carriage of grill to work site, hoisting as per building specification and direction of E/I.
46Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness,including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strikeplate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineerin-charge:
47Supplying, fitting & fixing 30mm thick solid core type decorative Single leaf flush shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with Aluminium fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/I.
48Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fastenersetc.).
49Supplying , fitting and fixing collepsible gate of approved size & make properly febricated with vertical double channels 20 x 10 x 2 mm at 100 mm center & braced with M.S.flat diagonals 20 x 3 mm, with top & bottom rails of T - iron 40 x 40 x 6 mm with 38 mm dia steel pulleys complete with bolts, nuts, locking arrangements, stoppers, handles, including applying a priming coat of red lead paint, carriage, hoisting & taxes all complete as per building specification and direction of E/I.
50Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron
51Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness
52Supplying, fitting & fixing 35mm thick solid core type decorative Double leaf flush shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with Aluminium fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/I.
53Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc.complete as per design approved by Engineer-in-Charge Granite work
54Providing and fixing wooden moulded beading to door frames with iron screws, plugs and priming coat on unexposed surface etc. complete. 50X20 MM
55Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
56Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand),jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm
57Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement:4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
58Glazed Vitrified tiles Matt/Antiskid finish of Size of Tile 600 x 600 mm sqm 1311.05
59Marble work gang saw cut (polished and machine cut) of thickness 18 mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade (To be secured to the backing by means of cramps, which shall be paid for separately). Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble. Area of slab upto 0.50 sqm
60Providing and laying 25mm thick kotah stone slab flooring of approved size texure and colour over 19mm thick base of lime mortar (1:1:1) (limeputty:surkhi:coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I.600x600 Size
61Extra for plaster work over exterior surface for each consecutive floor above first floor including cost of scaffolding etc. all complete as per direction of E/I.
62( a) For S.F.
63Making 6x6mm grooves in plaster surface over walls truly horizontal vertical as specified at regular intervals at all heights including cleaning finishing scaffoding and curing with all leads and lifts of water all complete as per building specification and direction of E/I.
64Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size)
65Providing & supplying Cico liquid / impermo water proofing compound in cement concrete or cement mortar @ 2% of cement quqntity by weight ( as specified) for water proofing, including all carraige and taxes .
66Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) :Light shade pigment using white cement
67Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
68Providing 19 mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I.
69Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
70Providing 250 mm wide brick drain in cement mortar (1: 6) with av. 150 mm. clean depth and 150 mm apron including cost of earthwork involved with 75 mm, cement concrete (1: 4: 3) over one brick designation 75A, flat soling in proper grade and slope at the base, the drain duly plastered in C.M (1:3) with punning over exposed surface all complete as per building specification and direction of E/I.
71Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
72Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm)over and including priming coat of exterior primer applied@ 2.20kg/10 sqm
73Providing two coat of Oil bond distemper of approved shade and make over a cement primer over new surface including preparing the plastered surface by rubbing smooth with pumic stone or fine sand papper ,applying putty where required scaffolding, washing the floor and taxes all complete as per building specification and direction of E/I.
74Finishing Wall with acrylic smooth exterior paint of required shade : New work ( Two or more coat applied @1.67 lit./ 10 sq.m over and including base coat of water proofing cement paint applied @ 2.20 kg/10 sqm)
75French spirit polishing :Two or more coats on new works including a coat of wood filler
76Provinding primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dirt, scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurment Area shall be multiplied by the co-efficient as indicated in building specificaton.)
77Providing two coats of synthetic enamel paint of approved shade and made over steel surface including cleaning the surface thoroughly including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I
78Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
79Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming toIS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
80Coupler 110 MM
81Single pushfit Coupler
82110 MMSingle pushfit coupler
83Single tee with door
84110X110X110 MM
85Single tee without door
86110X110X110 MM
87Bend 87.5°
88110 MM Bend
89110 MM Shoe
90Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size).
91Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge.
92Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.
93Fly Ash Bricks
94Bricks
95Coarse Sand
96Stone Chips
97Cement
98Steel
99Earth
100Section II Water Supply
101Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls
10215mm dia
10320mm dia
10425 mm nominal outer dia Pipes
10532 mm nominal outer dia Pipes
106Providing and fixing 15 mm dia male ended brass bib cock of approved quality (wt. not less than 350 gms. ) with extra socket all complete as per specification and direction of E/I.
107Supplying materials labour tools for fixings of gun matel full way valve of approved quality with all complete job.
108(a) 25 mm dia
109Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. Jaquar/Hindware Make
11015 mm nominal bore
111Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
112Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved makeand shade with 6 mm thick hard board backing : Circular shape 450 mm dia
113SANITARY WORK
114Supplying , fitting and fixing vitreous white glazed earthen ware I.W.C. of Party Hindustan or any other I.S.S approved make with 100mm H.C.I. \\"P\\" trap 15 litres C.I. pull and let go flushing cistern of nmaes or other I.S.S equipalent make complete with all fittings, C.I. or C.C. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing apair of vitreour white glazed eaarthenware foot rest to be fixed in floor 15mm C.I. bodybrass spindle stop cock ofweight notless than 50grms, 15mm P.V.C. connection pipe 450 mm long and the exposed piep and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per building specification and direction of E/I. Jaquar/Hindware Make
115580mm long I.W.C. pan with 10 litres low leve P.V.C. Cistern. Hindware/Jaquar Make
116Supplying fitting and fixing 40mm high vitreous white glazed earthen E.W.C with Ptrap of parry/Hindustan or any other approved I.S.S make ineluding supplying and fixing 15 liters C.I mosquito proof low down flushing cistern of approved make with complete fittings with C.I handle and R.S or bracket wit h telescopic flush pipe with brass eoupling and plumbers joints spindle stop coci of approved quality weight not less than 450grams 15mm P.V.C alkathene pipe 45cm long with brass coupling at both ends and white /black plastic solid state seal and lead of commander / cuckoo or other I.S.S make with hinges or screws etc painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide priming all complete as per specification and direction of E/I. (I) With 'P' trap(b) 10 Lit Law Lavel PVC Cistern.
117Providing and fixing wash basin with C.I. brackets, 15 mm C.P. Brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mmwith a pair of 15 mm C.P. brass pillar taps
118Providing and fixing PTMT Bottle Trap for Wash basin and sink Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms
119Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
120Providing and fixing white vitreous china flat back half stall urinal of 580X380X350mm with white PVC automatic flushing cistern, parryware/Hindware with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass with waste fitting as per IS : 2566 P.V.C. trap with outlet grating and other couplings in C.P. brass including parenting of fitting and cutting and making good the walls and floors wherever required..
121Single half stall urinals with litre P.V.C. auotmatic flushing cistern
122Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
123(a) 110 mm dia
124(b) 75 mm dia
125Making holes in walls for laying H.C.I Pipes and restoring the same after pipe laying as per specification and direction of E/I.
126(a) 250 mm thick wall
127(b) RCC chajja
128Providing and fixing PTMT towel ring trapezoidal shape 215 mm long,200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms
129Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements,weighing not less than 106 gms.
130Supplying materials and labours for constructing inspection chamber of designation class 100B bricks size 750mm deep, 600x450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600x450mm C.I . Cover with frame (weight not less than 39 Kg ) alongwith earth work in excavation and 80mm thick P.C.C. (1:3:6) in foundation and refilling all complete as per specification and direction of E/I
131Providing and laying non- pressure NP2 class ( light duty ) R.C.C. pipes with collars jointed with still mixture of cenent mortar in the proportion of 1:2 ( lcement : 2 fine sand ) including testing of joints etc. complete. 150 MM dia R.C.C. pipe .
132250 mm dia. R.C.C. pipe
133Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.15 mm nominal bore with 45 cm length
134Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming toIS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
135Coupler 75 MM
136Coupler 110 MM
137Single pushfit Coupler
13875 MM
139110 MMSingle pushfit coupler
140Single tee with door
14175X75X75 MM
142110X110X110 MM
143Single tee without door
14475X75X75 MM
145110X110X110 MM
146Bend 87.5°
14775 MM Bend
148110 MM Bend
14975 MM
150110 MM Shoe
151Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm,including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink with drain board
152510x1040 mm bowl depth 225 mm
153Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :
154150 mm diameter
155Section - III Septic tank & Soak pit
156Earth work in excavation in foundation trenches in ordinary soil(vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I.
157Extra for earthwork in hard soil as per specification and direction of E/I.
158Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
159Providing designation 75A brick work in C.M (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I.
160Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I.
161Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size)
162Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
163Providing, hoisting and fixing above plinth level up to floor five level precast Reinforced cement concrete in shelves, including setting in cement mortar 1:3 (1cement : 3 coarse sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
164Providing Tor steel reinforcement of 8 mm dia rods as per approved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per builing specification and direction of E/I.
165Providing TMT Steel reinforcement of 10mm, 12mm & 16mm dia bars as per approved design and drawing excluding carriage of M.S. Rods (straight or in coils) to work site, cutting bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I
166(a) 10 mm TMT bar FE 500 ( Only Valid for SAIL & TATA Steel )
167Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
168Providing 12mm thick cement plaster (1:4) with clean coarse sand of F.M. 1.5 approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
169Providing 1.5 mm thick cement punning including curing, carriage of water with all leads and lifts of water as per building specification and direction of E/I.
170Supplying fitting & fixing H.C.I. pipes with ear of approved make confirming to I.S.I. 1729 including supplying nails and bobins short pieces, cutting loose collars lead and yarn for making lead caullked joints, cutting pipes to size including earth work or scaffolding where necessary etc all complete as per spectification & direction of E/I.
171( a ) 100 mm dia.
172Providing and laying brick bats in soakpit with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I.
173Supplying, fitting and fixing C.I. cover with frame for mane hole and inspection chamber with all leads and lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of E/I. (a) Size 600 x 450 mm (Wt. 25 Kg).
174Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.
175Bricks
176Coarse Sand
177Stone Chips
178Cement
179Steel
180Section-IV (Deep Bore Well) 2 Nos.
181Suppling all materisls labour and tools and cost of drilling 200mm x 165mm bore well in all kinds of soil and rock in rural area for installation of pump set with hydrolic DTH rig machine, all complete including suplying all materials tools, drilling rig, Air compressor and equipments, as well as fuel, lubricants and cost of transprtation of Rig machine and other vehicles up to the site.
182From 0.0M to 50.0 M belew G.L
183From 51.0 M to 200.00 M belew G.L
184Supplying all tools, tackles & lowering of 200 mm dia MS ERW casing pipe of 6mm wall thickness including welding charges, cost of pipe itc including all taxes, VAT, Excise duty, freight charges with inspection charges etc as applicable, etc all complete job.
185Cleaning Flushing and devloping of drilled hole for testing the discharge of water development of bore well by continueous flow of water bu using heavy compresser upto satisfaction of E/I. To get uniterrupted flow of water free from sand and soil etc.
186Supplying and fitting M.S cap over 200mm dia casing pipe as per direction of E/I .
187Supplying 100 mm dia submersible pump sets confirming to IS 8034 and motor confirming to IS 9283. Pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/ noryl impeller. Motor suitable for working on 415V + 10%, 3PH, 50 Hz, A.C. supply with cable guard, thrust carbon/ fiber bearing to withstand entire hydraulic thrust, water proof winding shall be provided. The pump set shall be suitable for direct coupling. Pump shall have suitable outlet as per manufacturers design. Anti thrust stream lined non return valve shall be provided with pump. 3 meter submersible copper conductor cable in single/ double run shall be provided with each pump.
188Submersible Pump 150 mm dia ( with Bronze impeller) up to 8 stages2.0 HP
189Supplying Fully Automatic Starter to operate induction motor working on 415v, 3 phase ,50 hz with no volt coil , Over load element , ON-OFF push buttons with necessary materials and connected to supply etc complete starter with original sheet steel encloser as per IS: 3914.F.A.S.D. Starter
190Supplying 3 core flat flexible submersible cable with, copper conductor, PVC insulated and PVC sheathed as per IS : 70983 Core 4mm thick
1912no heavy duty clamp 40mm dia duitable for pipe with all complet job.
192Supplying & lowering 40mm da column G. I. pipe with all complete job.
193Section-V Rain Water Harvesting
194Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I.
195Extra for earthwork in hard soil as per specification and direction of E/I. ( Vide classification of soil iten _B)
196Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
197Providing designation 75 A one brick flat soling joints files with local sand including cost of watering taxes royalty all complete as per building specefication and direction of E/I
198Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size)
199Providing designation 75A brick work in C.M (1: 4) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I.
200Stone Metal at quarry site .. Traxes and royalty all complete as per building specification and direction of E/I.90 mm Gravel filling
2010.90 M stone Boulder filling
202Providing, hoisting and fixing above plinth level up to floor five level precast Reinforced cement concrete in shelves, including setting in cement mortar 1:3 (1cement : 3 coarse sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
203Providing 12mm thick cement plaster (1:3) with clean coarse sand of F.M. 1.5 approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
204Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scafolding taxes and royalty all complete as per buildings specification and direction of E/I.
205Providing Tor steel reinforcement of 8 mm dia rods as per approved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per builing specification and direction of E/I. (TMT Fe 500 (Only valid for SAIL & TATA Steel )
206Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
207Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion.
208110 mm bend
209Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete (110 mm )
210Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.
211Bricks
212Coarse Sand
213Stone Chips
214Cement
215Steel
216125/115 mm dia drilled Tube Well for drilling in all kinda of Soil and rock for installation o hand pump with DI rings all complete including supplyin all materials, labours , tools drilling rigs air compressor and equipments s well as fuel li\ubricant for making 125/115 mm dia boring etc and cost of transporting rig machine and other vechile up to site of work including contrctor profit & OH chares as per specification and directtion of Engineer Incharge(basic rate)
217Drilling upto 30 M depth below G.L in Rular area
218Drilling beyond 31 mtr upto 55 mtr below GL in Rural area
219Supplying all materials labours equipments for lowering 125 mm dia blue UPVC Casing Pipe as casing for protecting the sides from falling during the process of drilling all complete including carrriage of materials to work site (Basic Rate)
220S/M/L for F/f wire mesh pipe
221Section-VI Approach Road (25 Metre.)
222Excavation in Soil by Manual means. (Excavation for foadway in soil using manual means including loading in truck for carrying of cut earth to embankment site with all lifts and lead upto 1000 metres.)(ii) Including Royalty @ Rs. 27.48 per cum the cost of watering, rolling & compaction
223Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
224Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
225Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)
226Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.
227Bricks
228Coarse Sand
229Stone Chips
230Cement
231Electrical Installation Work
232Section VII Note:- (1)PVC insuleted copper conductor cable of make:-Havell's/HPL/Polycab/Mescab/Anchor (2)PVC conduit of thikness 1.5mm/2mm for wiring:-Polycab/Arkaylitel/Saini star (3)Switches/soket outlet for piano type:-Anchor/ Cona/Havells/HPL (4)Switches/soket outlet for modular type:-Roma(Anchor/wood)/Havell's(carbtree)/ Hpl/Philips/Cona (5)MCCB,MCB,SFU,CHANGEOVER,RCCB,MCB-DB:-Havell's/Hpl/L&T/Legrand/C&S (6)XLPE/PVC aramoured cable:-Havell's/polycab/capital/V-guard (7)Electrical fitting/fixtures:-Bajaj/Philips/Crompton/wipro/Hpl (8)All internal wiring work should be recessed(conseeld)
233Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc.
234Group B
235Twin control point wiring PVC conduit with modular type switch:-wiring for Twin control point with 1.5 sq mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, 2 way modular, switch, pheonlic lamineted sheet,suitable size G.I.box etc.as required.
236Power plug wiring in PVC conduit (2x4 sq mm) :- Wiring for light/Power plug with 2x4 sq mm FR PVC insuleted copper conductor single core cable in recess PVC conduit along with 1 Nos. 4 sq mm FR PVC insuleted copper conductor single core cable for loop earthing as required.
237Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required
2382x1.5 sq mm+1x1.5 sq mm earth wire (for 2 set of 5 amp switch and socket)
2392x2.5 sq mm+1x2.5 sq mm earth wire (for circuit wiring)
2402x6.0 sq mm+1x6.0 sq mm earth wire (for sub main wiring LDB)
2412x10.0 sq mm+1x6.0 sq mm earth wire (for sub main wiring PDB)
2422x16.0 sq mm+1x6.0 sq mm earth wire (for submain wiring PDB G FLOOR)
2434x2.5 sq mm+2x2.5 sq mm earth wire (for building outer light)
244TV cable in existing conduit :- Supplying and drawing co-axial TV cable RG-6 grade copper conductor,PE insulated,with PVC sheath in the existing recessed PVC conduit as required.
245S/F PVC conduit :- supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required .
246S/F PVC/G.I. boxes :- Supplying and fixing PVC/G.I. box of following sizes on surface or in recess with suitable size of phenolic laminated sheet cover infront including painting etc as required .
24775mm x 75mm x 50mm deep/ (4\\" x 4\\")
248S/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required
2495/6 amps, one way switch
2505/6 amps, 3 pin socket outlet
251TV antenna socket outlet
252S/F Modular type electronic fan regulator:-Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connectionons but excluding modular plate etc, as required.
253S/F Modular type blanking plate:-Supplying and fixing modular blanking plate on the existing modular plate switch box excluding modular plate etc, as required.
254S/F Modular boxes, base & covre plate:-following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc, as required.
2551 or 2 module(78mm x 78mm x 45mm)
2566 module(78mm x 205mm x 50mm)
257S/F power plug point with modular type accessories:- Supplying and fixing suitable size G.I.box with modular plate and cover in front on recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switch conection painting etc, as required.
258S/F ceiling rose:-Supplying and fixing 2 pin 5 amp, ceiling rose on the existing junction box/wooden block including connection etc as required.
259S/F Batten holder:-Supplying and fixing batten/angle holder including connection etc, as required.
260Errection on incandescent light fitting:-Errection of wall bracket/ceiling fitting, complete with all accessories including connection etc as required.
261S/F Dingdong Call bell :-Supplying and fixing dingdong call bell suitable for DC/AC single phase,230 volt, complete as required.
262ITC exhaust fan up to 450 mm, sweep:-Installation of exhaust fan up to 450 mm. sweep in the exiting opening, including making the hole to suit the size of above fan, making good the damage, connection testing commissioning etc as required.
263S/F S.P. MCB DB:-Supplying and fixing following way single pole nutral,sheet,MCB distribution board,240 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR)
26412 Way,Double door
265S/F 'B' series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, 'B' series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required.
2666/32 amps,single pole, \\"B\\" SERIES
267S/F 'C' series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, 'C' series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required.
2686/32 amps,single pole, \\"C\\" SERIES
26940 amps ,DP
27050/63 amps, DP
271P/F M.V. danger notice plate:-Providing and fixing M.V danger notice plate of 200mm x150mm made of mild steel, at least 2mm thick, and vitreous enamelled white on both sides, and with inscription in single red coiour on front side as required.
272Copper Earth plate electrode:-Earthing with copper earth plate 600mmX600mmX3mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required.( with salt charcoal or coke)
273S/L 8 SWG copper wire ground :-Supplying and laying 8 SWG copper wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required.
274P/F G.I. lightning conductor finial:-Providing and fixing of lighting cnductor finial, made of 25 mm dia 300mm long, copper tube having single prong at top, with 85mm dia 3mm thick G.I. base plate including holes etc. complete as required.
275Reverting, sweating and soldering of copper/G.I. tape(with another coppr/G.I. tape, base of the finial or any other metallic object) as required.
276P/F G.I. lightning conductor tape in horizontal run:-Providing and fixing GI tape 20mm x 3mmthick on parapet or surface of wall for lightning conductor complete as required(For horizontal run)
277P/F G.I lightning conductor tape in vertical run:-Providing and fixing GI tape 20mm x 3mmthick on parapet or surface of wall for lightning conductor complete as required(for vertical run)
278P/F Testing joint for G.I. lighting conductor:-Providing and fixing testing joint, made of 20mm x 3mm thick G.I. strip, 125mm long, with 4 nos.of G.I. bolts, nuts, chek nuts and spring washers etc complete as required.
279Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size exceeding 35 sq.mm.but not exceeding 95sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required.
280Supply of PVC XLPE insuletd PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:7098, part-1)
28150 sq.mm. 3.5 core
28295 sq.mm. 3.5 core
283Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required
284Supplying and making end termination with brass commpression gland and aluminium lugs for following size of PVC insuleted and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required.
2853½ X 50 sq. mm (35mm)
2863½ X 95 sq. mm (45mm)
287Providing of 12'' (300 mm)exhaust fan of make bajaj/havells/usha/crompton
288Providing of 15'' (380 mm)exhaust fan of make bajaj/havells/usha/crompton
289Providing of 16'' (400 mm) Wall fan of make bajaj/havells/usha/crompton
290Providing of Bulkhead fitting with 9/10 watt LED/ CFL of make bajaj/havells/crompton
291Supplying and fixing of LED/CFL 18/20 W of make bajaj/havells/crompton
292S.I.T.C of following size ceiling fan 3 blades confirming to IS:374:2019 including wiring the down rods of standared length (upto 30cm) with 1.5 sq.mm FR PVC insuleted ,copper wire suitable for 230 V 50 Hz, single phase supply etc. complete as required.
2931200 mm (48\\") Ceiling Fan of make bajaj/havells/usha/crompton/polar
294SITC of following rating surface mounted LED tube light fitting suitable for 230 V 50 Hz, single phase supply etc .complete as required
29510/12 W LED Batten of make bajaj/havells/crompton/C&S
29620/22 W LED Batten of make bajaj/havells/crompton/C&S
297SITC of following rating LED street lighting luminarie with pressure dia cast housingh and toughned glass cover ,IP 66 Protection , LUMINOUSEFFICARY >_110 LM/W with lens in existing pole /pipe for supply voltage 100-270V AC ,50 Hz, luminarie shall be confirm to IS 10322 part -5 /section -3 and shall be complete with all neccssary accessosries as required.
29890 /100 W LED Street light of make bajaj/havells/crompton/C&S
299SITC of following rating recess/ surface mounted LED round /square shape down light luminire with pressure dia cast housing for single phase supply voltage, Luminarie shall be confirmto IS:10322 part - 5/section -2 or IEC : 62722 with all neccessary accessories as required.
30015/16 W LED Round Down Light of make bajaj/havells/crompton/C&S
301Design manufacture, supply installation, testing and commissioning of 16 SWG sheet steel fabricated cubical type floor mounting front operated construction, enclosure class - IP 52, finishing with 7 tank process and powder coating of the entire panel including covers in required shade complete with top / bottom ( as called for ) removable gland plates, cable alleys, double compression doors to achieve dust and vermin proof complete with all inter connections small wiring by copper wires, ckt labels etc. The Copper Bus Bar shall be of suitable size for 500 volts, 3 phase 50 Hz TPN, electrolytic copper as per Is 8623 insulated by heat shrinkable sleaves with surround joints. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmeter, selector switches, CT's, PT's, etc. The panels shall be got fabricated only from panel builders having 7 tank process finishing system and CPRI approved certificate for similar LT Panel.
302LT PANEL (NORMAL SUPPLY) :35 KA) -INCOMING (1- sets ) each with following:
303INCOMING
304160 amps, 35 KA fixed thermal seting
305200 amps
306160 amps, 4 pole change over
307OUTGOING
30840 amps ,DP
30950/63 amps, DP
3106/32 amps ,DP
31140 amps 4 pole Isoletor
312OTHER ACCESSOSRIES
313DIGITAL VOLT METER 500V(3phase class 0.5)
314DIGITAL A METER 500V(3phase class 0.5)
315COPPER WIRE 1.5MM
316COPPER WIRE 6MM
317COPPER WIRE 10MM
318COPPER WIRE 25MM
319LED INDICATOR LAMP R/Y/B/G
320C.T COIL OF CT ratio 500/5 IS2705 part -3
321LT PANEL(Waterproof) :-Supplying, designing, manufactored Double Door LT Panel fabricated out of 2mm thick(14SWG) CRCA sheet steel, dust and vermin proof with reinforcement of suitable size iron channel, size 75mmx75mmx6mm with proper lifting arrangement effecting proper connection of all incomer and out going (IP-43) fully compartmentalized cubical type (folded joints construction), wall floor mounted, totally enclosed, extendable on both sides, switch board and suitable for use on 415V, 3 phase, AC Supply, 4 wire, 50 C/S, system having 36 KA fault capacity, housed with incoming,Steel Stand, interconnection, interlocking between feeders etc. space for 3 Phase Energy meters as required. The sheet steel under go minimum 7 tanks treatment followed by finishing of powder coating of minimum 60 micron thickness, duly compartmentalized cubical panel, 2 Nos. earth studs. The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions.The pannel shall be interlocked with switchgear.The gap between live part of the Panel shall be minimum 35mm.All openings shall be covered by soft rubber gasket (metal based neoprene) having structural re-inforcement with suitable Angle/Channel/T/Flat sections, hinged and lockable doors enclosure shall be galvanized.
322Add 18% GST
323Add 1% Lebour Cess Please Enable Macros to View BoQ information

Other Detail

Information Source https://jharkhandtenders.gov.in
Download FileName File Description File Size
Download Tendernotice_1 (3).pdf Tender Documents 0 KB
Download 4c71f4b4-155a-4167-ae7f-17e98a9858c7.html Tender Documents 0 KB
Download BOQ_150060.xls Tender Documents 0 KB
Download SBD02.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.