Tender For Supply & Commissioning Of Scada Cum Gateway Server With Latest Configuration For Configuration, Testing And Commissioning Of Gateway System At 132Kv S/S Biswan Under Etd, Sitapur., Sitapur-Uttar Pradesh
TDR : 54518672
Tender Notice
BOQ
4 Days Left
Sitapur
Uttar Pradesh
Tender For Supply & Commissioning Of Scada Cum Gateway Server With Latest Configuration For Configuration, Testing And Commissioning Of Gateway System At 132Kv S/S Biswan Under Etd, Sitapur.
Name of Work:- Supply & Commissioning of SCADA Cum Gateway Server with latest configuration for configuration, testing and commissioning of Gateway System at 132KV S/S Biswan Under ETD, Sitapur.
Sl. No.
Item Description
1
Supply of SCADA cum Gateway Server with latest configuration for configuration, testing and commissioning of Gateway System at 132kV S/S Biswan. Advantech/equivalent make with Intel Core i3-12500, 16GB RAM, Windows 10 OS, 512TB SSD, USB (6 Ports), RJ45 (2 Ports Rear), Single Power Supply License Software - Windows OS + Antivirus. Suitable for existing SCADA System as installed at 132KV Sub-station Biswan.
2
Supply, configuration and testing of new industrialgateway suitable to transfer the IEC-104 data to SLDC Lucknow & ALDC Modipuram. The following works to be carried out in gateway at substation level;Works Included:Supply of 2 no. of IEC-61850 Compliant IndustrialGateway suitable for transfer to data at SLDC and ALDC having following features;I. From 132kV S/S Biswan to SLDC Lucknow.II. From 132kV S/S Biswan to ALDS Modipuram.Specification of Gateway:1. With dual RJ-45 Port which can be configured for Independent IP address as per site requirement.2. Industrial Protocol Gateway: IEC 61850 EthernetServer to IEC 60870-5-104 Ethernet Client.3. Compliant with IEC 61850-3 and IEEE 1613 PowerSubstation Standards.4. Works in environments from -40°C to +80°C5.User friendly configuration with a Java-BasedWindows utility.6.Embedded PPTP, IPsec and OpenVPN Client/Server for enhanced security.7.Redundancy through embedded RSTP Protocol.8.5 Years manufacturer warranty.
3
Configuration of ICD/CID file for existing 132kV and 33kv feeders /bays. Following work to be carried out for SLDC Lucknow & ALDS-Modipuram:1.Complete configuration and testing of Gateway as per the signal list and parameter provided by client to transfer the data on IEC-104 2.Programming and resetting of communication of link of Gateway from data transfer as per IP address provided by UPPTC. 3.Complete testing of Gateway and validation of real time data as per existing signal list4. Complete checking of SAS gateway panel included architecture and settings. Following Feeders are Included.1. 132KV SITAPUR BAY2. 132KV KANDUNI-I BAY3. 132 KV KANDUNI-II BAY4. 132 KV BISWAN RLY. TSS BAY5. 132KV SEKSARIA SUGAR MILL BAY6. 132/33 KV 40 MVA T/F BAY7. 132/33KV 20 MVA T/F-I BAY8. 132/33KV 20 MVA T/F-II BAY9. 132KV TBC BAY10. 33 KV BISWAN TEHSIL BAY11. 33 KV BISWAN RL BAY12. 33 KV SANDA RL BAY13. 33 KV REAUSA N.P. BAY14. 33 KV TBC BAY15. 33 KV BELENUS BAY
4
For Rectification/modification/repair of existing Ethernet switch (2 Nos. Transmitting and Receiving data ) in Gateway Panel for healthycommunication with SLDC & ALDC.
5
Supply and Installation of power supply cord for existing Ethernet Switch and its rectification of issue in existing ethernet switch.
6
Checking and troubleshooting of existingEthernet Switch using relevant software and tools for real time for data transfer to SCADA
7
Configuration of Switch for same cloud of the network control center for data transfer
8
Supply of FO cable/patch cord/LIU/Cat6 Cable and itsrelated hardware, splicing work to complete the networkcommunication for smooth execution of Gateway system.- Checking healthiness and rectification of fault/issue of FO Network:-- Splicing and termination of FO cable in each Kiosk- Checking the healthiness of all protection relay'scommunication to Gateway- Checking the healthiness of existing IEC 61850-7Ethernet switch in existing panel, however, in case of any faulty ethernet switch, same shall be arrangedby UPPTCL for completion of work.
9
Supply of Armored FO Patch Cord (LC-LC – 3 Meter) Please Enable Macros to View BoQ information