Indian Tenders

Tender Notice

TDR 54483393
Tendering Authority military engineer services
Tender No 8746A
Tender ID 2026_MES_755157_1
Tender Brief Corrigendum : Tender For Special Repair To Building No P-203 (Offrs Single Living Accn) At Brichgunj Mil Stn, Sri Vijaya Puram.
City South Andamans
State Andaman And Nicobar Islands
Document Fees INR 500 /-
EMD INR 89500.0 /-
Tender Value INR 44.74 Lakhs /-
Tender Type Works
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender For Special Repair To Building No P-203 (Offrs Single Living Accn) At Brichgunj Mil Stn, Sri Vijaya Puram.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 30-03-2026 Date Corrigendum 2 Date 06-04-2026
2 24-03-2026 Date Corrigendum Date 31-03-2026
3 24-03-2026 Date Corrigendum Date 31-03-2026

Key Dates

Publish Date 24-03-2026
Last Date of Bid Submission 31-03-2026
Tender Opening Date 02-04-2026

Contact Information

Company Name military engineer services
Contact Person GE Brichgunj Sri Vijaya Puram
Address GE Brichgunj Sri Vijaya Puram

BOQ Items

Name of Work:- Spl repair to Bldg No P-203 (Offrs Single Living Accn) at Brichgunj Mil Stn, Sri Vijaya Puram.
Sl. No. Item Description
1Demolition of reinforced roof slabs, beams, staircases, landing, chajjas and similar suspended work complete all as specified and as directed by Engineer-in-Charge
2M&L Precast Cement Concrete Block Masonry with Solid Block, exc 10cm in width in type C-1, 1:3:6 (using 20mm graded stone aggregate) set in CM (1:6) all as specified.
3Demolition of PCC Block walling built in CM 1:6 complete all as specified and as directed
4Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specified complete all as directed.(plinthprotection)
5Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing the rubbish off the premises.
6M&L for 25 mm thick cement concrete type B1,1:2:4 (using 20mm graded stone aggregate) finishing the surface even and fair complete all as specified and as directed.
7M&L Non skid ceramic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.18 Sqm but n.exc 0.38 Sqm, in neat cement slurry and pointed in white or coloured cement with pigment to match over 15mm thick screed bed in cement mortar (1:6) all as specified and directed.
8M&L Glazed ceramic coloured / printed tiles (450X300mm) x 6-7mm thick on vertical surfaces as in skirting/dado, set and jointed with neat cement slurry and pointed in white/coloured cement to match the shade of tiles over 10mm thick rendering in cement mortar 1:3 all as specified and directed.
9Taking down cement plaster on Brick / Concrete surfaces incl raking out joints, hacking for key scrubbing down with water and Removing Rubbish out side of the MD Land all as directed by Engineer-in-Charge.
10M & L for rendering 10 mm thick in CM I:6 finished even and smooth without using extra cement etc complete all as specified and directed..
11M&L Rendering 15mm thick in two coat ie. 10mm thick under coat in CM 1:6 and 5mm thick finishing coat in CM 1:4 finished even & smooth without using extra cement using 3% of WPC
12M & L for rendering 5 mm thick in CM 1:3 on for ceiling /chajjas surfaces, finished even and smooth without using extra cement etc complete.
13M&L preparation of newly plastered surfaces of wall and applying two coats of Oil Bound distemper over a coat of primer complete all as specified and directed.
14M&L preparation of newly plastered surfaces of ceiling and applying two coats of Oil Bound distemper over a coat of primer complete all as specified and directed.
15M&L for Preparation of old plastered or unplastered surfaces of walls and applying two coat of oil bound distemper complete all as specified and directed by Eng-in charge.
16M&L preparation of old plastered surfaces of ceiling and applying two coats of Oil Bound distemper over a coat of primer complete all as specified and directed.
17M & L for 1 mm thick on wall care putty on wall complete all as sepecified and as directed.
18M & L for 1 mm thick on wall care putty on ceiling surfaces complete all as sepecified and as directed.
19M&L for complete removal of existing treatment on new/old plastered surfaces of walls and applying two coats of Plastic Emulsion Paint on the plaster surfaces over a coat of primer with water proof putty of two coats over a coat of damp proof primer complete all as specified and directed by Engineer-in-charge.Make: Berger (Glamour),Asian paints (Royal Shine),Nerolac (Impression Kashmir).
20M& L for Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) etc complete all as specified and as directed by Engineer-in-Charge.(Make Apex Ultima)
21M & L for preparation of old plastered surfaces of wall and applying two coats of weather Proof Exterior acrylic emulsion paint with anti fungal property including seal-o-primer over a two coat of water proof putty complete all as specified and directed by Engineer-in-Charge.. Make :Berger (Weather Coat Longlife Flexo),Asian Paints (Apex Ultima),Nerolac (Excel No Dust)
22Taking down chowkats or frames exceeding n exc 1.5 sq. m each (Without taking off shutters & Grill from the frame).
23Taking down chowkats or frames exceeding exc 1.5 sq. m but n exc 4 sq. m each (Without taking off shutters & Grill from the frame).
24S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately).
25S&F factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of EngineerIn- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)
26S&F for anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified
27S & F anodised aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge.
28S&F for Anodised aluminium grill (anodised transparent or dyed to required shade according to IS : 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass /stainless steel screws @200 mm center to center, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening all complete as per requirement and direction of engr in charge.
29Supply and fix aluminium composite panel sheet of 4 mm thick with 0.5 mm thick aluminium sheet on both sides approved colour of exterior grade as in chajjas fixed on aluminium frame work with plastic strips ( double sided sticker) of suitable size , applying adhesive over aluminium sections for fixing composite panel and fixed with screws. The joints of panels shall be filled with weather proof sealant, The board shall be stuck with a layer of any colour high intensity reflective grade polymer sticker installed using epoxy adhesive complete all as specified and as directed. (Note : Necessary frame work if any will be measured and paid separately)
30Supply and fix aluminium composite panel sheet of 4 mm thick with 0.5 mm thick aluminium sheet on both sides approved colour of interior grade as in aluminium frame work for doors,windows ,Almirahs with plastic strips ( double sided sticker) of suitable size , applying adhesive over aluminium sections for fixing composite panel and fixed with screws. The board shall be stuck with a layer of any colour high intensity reflective grade polymer sticker installed using epoxy adhesive complete all as specified and as directed. (Note : Necessary frame work if any will be measured and paid separately)
31S&F in repairs for providing and fixing stainless steel (Grade-304) ) railing made of hollow tubes, channels, Plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the drain cover with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangments.
32M&L for removing loose and broken concrete by chiselling /picking etc upto a depth of 10 to 30 mm from floor/roof slab/chajjas and similar structural members cleaning the dismantled portion with wire brushes etc to remove dust, dirt and other foreign particles including necessary scaffolding etc and removal of debris to a distance not exceeding 50m, complete all as specificed and as per directed by Engineer-in-Charge.
33M&L for application of high build polymer cement sand mortar 1:2.5 with water cement ratio 0.35 to 0.45 mixing with Nito bond SBR @ 5 ltrs per 50 Kg cement on ceiling / chajja surfaces 10 to 20mm thick in two layers over slurry priming coat of 1 volume Nito bond SBR to 1 volume water, 3 volume fresh cement (5 sqm per litre Nito Bond SBR) etc all as per manufacturers instructions, including painting/finishing to match with the existing complete all as specified and as directed.[ Note : Nitobond SBR shall from Fosroc chemical (India) Pvt Ltd or equivalent chemicals of MC Bouchemics/Beck].
34M & L Water proofing treatment to roof , edges of roof, Chajja , Edges of Chajja & Top Facia ( Vertical or tapered portion) etc, in following portion sequence :- (i) Properly cleaning and drying the surface (ii) Applying priming method over cleaned surface, (III) Laying APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) Keep minimum 100mm overlap laid on primed surfaces by sealed and bonded to the surfaces by torching Method, including taking out old treatment complete upto mother slab complete all as specified and directed.
35M & L for Cement concrete 1:2:4 type B-1 ( using 20mm graded stone aggregate ) as in levelling coarse and other works as in roof,kerb, copping , padding with wpc etc complete all as specified and directed.
36M & L Chequered cement concrete tiles, with grey cement and pigment 30cm x30cm x20mm thick set, jointed and pointed in neat cement slurrry in floors including 15mm thick screed bed in Cm 1:4 all as specified and directed.
37M&L PCC 1:3:6 type C2 using 40 mm graded stone aggregate as in plinth protection of 75 mm thick finished fair and even, using extra cement complete all as specified and as directed
38S&F 100 Butt hinges extruded aluminium alloy, anodised. With galvanished mild steel hinge pin , anodised and fixed type B-21 complete all as specified and as directed
39S&F 200mm Aluminium anodised barrel tower bolts of extruded sections complete all as specified and as directed.
40S&F 150mm Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed.
41S& F Aluminium alloy anodised sliding door bolt with hasp, staple (bolt type) 300 mm long and fixing clips of sheet cast or extruded sections and fixing bolt or cast aluminium alloy& fixed complete .
42Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 20 mm dia .
43Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 25 mm dia .
44Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 40 mm dia .
45Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified of dia 20 mm.
46Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified of dia 25 mm.
47Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified of dia 40 mm.
48M & L in repairs PVC (SWR) floor trap 75 mm dia plain with grating including jointing with solvent cement ..
49M & L in repairs PVC (SWR) Gully trap 125/110 mm dia setting and jointing with solvent cement ..
50S&F in repairs 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints,laid in floor.
51S&F in repairs 75mm dia outlet PVC (SWR) PVC (SWR)floor trap with grating including jointing with solvent cement
52S&F in repairs 110mm PVC (SWR) WC connector bent type setting including Joining with solvent cement
53S&F in repairs 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints,fixed to walls
54S&F in repairs 75mm dia PVC (SWR) bend with oval access door
55S&F in repairs 110mm dia PVC (SWR) bend with oval access door
56S&F in repairs PVC (SWR) cowls 100mm dia.
57S&F in repairs stack clamps out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays ,including bolts and nuts and securing ends of stays to wall or roof.
58S&F in repairs 25mm dia aluminum powder coated best quality curtain rails including decorative globes at both ends complete all as specified and as directed.
59Supply and fix in repairs vitreous china CASCADE type WC single piece-WC with UF Soft close slim seat Cover, hinges, fixing accessories set, dual flush cistern fittings complete of size 655 x 360 x 765 mm , P or S trap-180mm in approved colour all as specified and directed as per ISI mark.
60S&F in repairs wash hand basin ovel type, vitreous china, of size 550x400mm fixed complete incl fixing the same in to granite slab complete including CP waist coupling , waste pipe, PVC Connection of twice on each WHB for Hot & cold all as specified and directed,Note:Cost of granite slab will be separatly in respective item of sch.
61S&F in repair 600mm x 450 mm bevelled Edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers.complete all as specified and directed by the Engineer -in- charge..
62S&F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
63S&F in repairs coloured Toilet paper holder, vitreous China, box type fixed to wall with chromium plated brass screws complete all as specified and as directed by Engineer-in-Charge.
64S&F in repairs two way bib cock, brass CP mixture 20 mm dia complete all as specified and as directed by Engineer-in-Charge
65S&F in repairsglass corner shelf complete all as specified and as directed by Engineer-in-Charge.
66S&F in repairsAluminium anodised chromium plated tubular towel rack, 20mm dia, D type, 60cm long, between flanges including suitable bracket complete all as specified and as directed by Engineer-in-Charge.
67S&F in repairs15mm angle stop valve of PTMT any colour high pressure screwed for iron pipe and fixed (minimum weight 15 mm -90gms) complete all as specified and as directed by Engineer-in-Charge.
68S&F repairs PVC connection 15mm size with CP brass Nuts of length 450mm complete all as specified and as directed by Engineer-in-Charge
69S&F in repairs 32 mm bottle trap for wash hand basin with inlet and out let screwed for pipe or connection including necessary packing union and cap and fixed complete all as specified and as directed by Engineer-in-Charge.
70S & F in repairs 15 mm dia bore Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and as directed by Engineer-in-Charge
71S & F in repairs 15 mm dia bore Brass CP wall mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and as directed.
72S&F in Repair Brass Chromium Plated Shower Rose 125 mm size suitable for 15 mm bore pipes including shower arm complete all as specified and as directed by Engineer-in-Charge
73Excavation in post holes (or similar holes) each not exceeding 0.5 cum getting out in Hard/dense soil returning filling in and ramming earth or broken rubble mixed with earth around in layers n.exc 25cm watering and removing surplus soil to a distance not exceeding 50m and making good surfaces complete all as specified and as directed.
74M&L for PCC 1:3:6 type C2(using 40mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and as directed.
75Supply only PVC coated (1mm thick) chain link fencing exc 2.00 but n.exc 3.50 kg per sqm with size of mesh 50 x 50 mm and thickness of wire n.exc 2.83 mm all as specified and as directed.
76Supply only 6mm dia wire PVC coated for support/ line wire to chain link fencing, complete all as specified and as directed
77Fixing only PVC coated chain link fencing including fixing of line wires any mesh, size and any type of standards, rails, straining bolts etc including provision of binding wires complete.(Supply of MS line wire and flat iron bolt & nuts measured and paid seperately) including taking down old wire fencing all as specified and as directed.
78Supply only mild steel angles, bars, flats etc as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 all as specified and as directed.
79Supply only mild steel bolts with hexagonal or square head one end and screwed the other or screwed both ends each screwed end to be fitted with washers and one hexagonal or square nut exc 5 cm long n.exc 10 cm long dia metre of neck exceeding 11 to 15 mm complete all as specified and as directed.
80M&L for preparation new steel surfaces of any description n.exc 10cm width or girth when unconnected with other painting or when painted in a different tint, and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
81M&L for preparation of old painted concrete surfaces ( terracotta paint) over 10 cm in width or girth and applying one coat of floor exterior emulsion paint complete all as specified and directed by Engineer-in-charge.Make :
82M&L Painting two coats of synthetic enamel paint over a coat of red oxide including preparation of old steel surfaces of any description over 10cm in width or girth not other wise described complete all as specified and directed.
83Supply and fixed in repairs 4.0mm thick Sheet glass ordinary quality and glazing with oil putty in Square exc 0.5sqm in each pane
84S & F in repairs aluminium alloy wire mesh 0.45mm nominal dia of wire and average width of apeture 1.4mm fixed with aluminium wire staples etc.complete all as specified and as directed by Engineer-in-charge.
85Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc.laid , beded and pointed inany mortar of (Any type of flooring)and and Removing Rubbish out side of the MD Land all as directed by Engineer-in-Charge.
86M&L 18-20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms and like in cement mortar (1:4) including point ing in white cement (1:2) us ing marble dust with admix ture of pigment to match with shade of granite
87Taking down carefully aluminium point wiring (light, fan, socket or power) DBs complete offering credit, making good disturbed surfaces of walls, floors, etc, all as specified and as directed.
88M&L Point wiring complete with 1.5 sqmm single core FRLS PVC insulated and unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including concealed PVC conduit and all accessories fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm copper cable green in colour as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover for housing the switches, socket outlets,fan regulators etc., all as specified and as directed for the following:-
89One light point controlled by one switch
90One exhaust fan point controlled by one switch
91One bell point controlled by one switch
92One fan point controlled by one switch and one regulator
93One 3 pin switch socket outlet point 5 amps on same board with other switches
94One 3 pin switch socket outlet point 5 amps on independent board
95One light point controlled by two 2-way switches, with cables 1.5 sqmm size
96All as per item No 88 here-in-before but for 3 pin 15 Amps switch socket combination on independent board with 4 sq mm copper cable and provision of 4 sq mm FRLS PVC insulated stranded copper conductor cable for earth continuity conductor connected to common earth dolly connecting upto fittings complete all as specified and as directed.
97Supply and fixing Modular switch 1 way 5 A, 1 module all as specified and directed.
98Supply and fixing Modular switch 1 way 15 A, 1 module all as specified and directed.
99Supply and fixing Modular Bell push 5A, 1 module all as specified and directed.
100Supply and fixing Modular switch 2 way 10 A, 1 module all as specified and directed.
101Supply and fixing modular socket outlet, 2/3 pin combined , 6/16 Amps, combined 2 module, 230 volts all as specified and directed.
102Supply and fixing modular socket outlet, 2/3 pin combined , 6 Amps, combined 2 module, 230 volts all as specified and directed.
103S & F modular white cover plate with frame, 3 module all as specified and directed.
104S & F modular white cover plate with frame, 4 module all as specified and directed.
105Supply and fixing modular fan step regulator, 230 V, AC, 120W - 2 module
106Supply and fix ceiling rose surface bakelite 65x50mm 3 terminal complete all as specified and as directed.
107Supply and fix bell push single phase, 240 Volts, 50 Hz, complete all as specified and as directed by Engineer-In-Charge.
108Supply and fix bell Ding Dong 240 Volts 50 Hz complete all as specified and directed by Engr-in-Charge.
109Supply and fix lamp holder(angle type) PVC body with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-in-Charge.
110Supply and fix LED lamp of 9/10 watt all as speciifed and dircted
111Supply and fix exhaust fan suitable for on working of AC 230 V, 50 HZ 225 mm sweep light duty , with metal body complete all as specified and as directed.
112Supply and fix in repairs sheet metal enclosures Loadline vertical distribution board TPN,4 ways 415 volts, with 200 amps rated bus bar, with IP 43 protection and double door, suitable for mounting MCBs and in and including 100A MCCB ,16KA as incomming complete all as specified and as directed including taking down old MCB DBs complete including cutting chases pinning in making good to facings where required and pointing in cement mortar 1:3 ends of edges of landing,steps, cills sunsades,shelves,lintels,etc and cutting for concealed conduit wiring etc and making good,cutting not exc 10 cm girth in brick wall complete all as specified.
113Supply and fix in repairs metal enclosure distribution board SPN, 8 way 240 volts, with 200 amps rated bus bar, double door suitable for mounting MCBs including taking down old MCB/DB complete all as specified and directed.Note-: Incoming & outgoing connections from the DB shall be provided with proper lugs/ thimbles etc
114Supply and fix in repairs MCB single pole 240 volts, 6 to 32 amps \\"B\\" series complete all as specified and as directed by Engineer-in-Charge
115Supply and fix in repairs single pole and netural 240 Volts 32 amps complete all as specified and as directed by Engineer-in-Charge
116S & F in repairs Single Pole and Neutral Enclosure with Two Pin Earth Plug and Socket complete with one MCB, SP, 20 Amps, 240 Volts fixed on flat iron 32x6 mm or 2nd class hard wood wooden board complete all as specified and as directed.
117Taking down old serviceable ceiling fan 1200 mm sweep by disconnecting the electric power supply, unscrewing the bolts and nuts, removing the blades and bearing including scrapping of old paint and applying two coats of synthetic enamelled white paint over a coat of red oxide primer complete and refixing back at site with new clamps, nuts, washers & bolts including cotter pin for complete all as directed.
118Supply and fixing in repairs aluminium housing LED batten 22 /20 Watt mounted batten fitting 4ft in length nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including lamp and connecting with twin core shethed cable from fitting to ceiling rose all as specified and as diected.
119Supply and fixing in repairs aluminium housing LED Smart bright batten 10 Watt mounted batten fitting 2 ft in length nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including lamp and connecting with twin core shethed cable from fitting to ceiling rose all as specified and as diected.
120S&F in repairs25 W New genration energy saving & envoirmental friendly long life versatile pressure dia cast aluminium IP65 road way luminaire with high power LEDs as light and electronic driver complete with necessary brackets (made out of 25 mm bore GI light grade pipe approx. 0.6 M long) nuts, bolts etc to be fixed as on walls complete as directed.
121Supply and fix Electric water heater storage type ( GeySer ) of 25 Ltr capacity BEE 5 star rated including inlet and out let connection with hot and cold pipe lines and all accessories etc including taking down old item and depositing in AGE E/M store all as specified and direcetd
122M & L in repairs for sub main wiring complete with two runs of 6 Sqmm FRLS single core PVC insulated unsheathed single core cable 1100 volts grade, multistranded with copper conductor (ISI Marked) drawn through and including PVC Casing and caping and all accessories fixed to wall/ roofs/ floors etc with one run of 6 sqmm FRLS single core multistranded copper conductor as earth continuity conductor, including dismantling unserviceable sub main wiring including accessories,complete all as specified and as directed by Engineer-in-Charge. Note : (1) Two runs of cable one run of casing caping & one run of earth continuity conductor shall be measured as one running metre.
123All as per above item Sr No 115.00 but of size 4 sqmm complete all as specified and as directed.
124M&L for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less thab 1.5 Meter below normal ground level connected to GI wire 4 mm dia by means of bolts, nuts , check nuts and washers of GI and GI tubing 20 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1 pre cast RCC (1:2:4) type B1 cover slab 54 x 54 x 5 cm with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing (LG) for watering, charcoal or coal and salt in alternate layers including excavation earth work complete all as specified and directed electrical plate No. 3 of SSR part - I
125supply & Lay in repair XLPE insulated, heavy duty 1100 volt grade electric armoured LT UG cable with aluminium conductor of size 25 Sqmm 3.5 Core in trenches/along the wall/including making all connections, saddles, spacers complete with aluminium lugs as required at site and as directed by Engr-in-Charge
126Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out Soft/loose Soil
127Returning, filling in, including spreading, leveling watering and well ramming in layers not exceeding 25cm soil / hard dense soil.
128Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point.Soft Soil / hard dense soil
129Supply & lay cable protection pipe of HDPE double wall corrugated (DWC) incl couplers,bends etc of size 50 mm OD and ID 38mm confirming to IS 14930 -II and ISI Marked all specified and directed.
130S&F 50 mm bore GI tube light grade galvanised with all fittings laid in trenches 50 mm bore.
131Material and Labour for cutting existing BT / PCCroad of size 45cm x 60cm for taking out/laying of underground cable/pipe and including necessary earth work and refilling the same in layers well ramming including watering as required and matching with the existing surface with 200mm thick PCC 1:2:4 type B1 and curing the same with wet gunny bags and removing debris to a distance not less than 50m complete all as specified and as directed .
132Supply, lay/fix, connect and testing steel water tubing of 25 mm bore, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings and fixtures,Clamps and fixed to wall/ceiling or laid on floors including taking down of old unserviceable pipe complete all as specified and directed.
133All as per item No 125 above but of size 40mm dia.
134S&F in repairs gunmetal gate or globe valve for 40mm dia, conforming to IS-778, ISI marked, with iron wheel head screwed at both ends for iron pipes or ferrule and fixing including necessary fittings like unions, check nuts, etc and any addition / alteration required for fixing, complete all as specified and as directed.
135All as per item No 127 above but of size 25mm dia.
136Supply and fix 25 mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed, complete all as specified and as directed
137Supplying, hoisting and fixing rotational moulded polythylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I of 1000 Litre capacity etc including taking down old tank complete all as specified and directed. Please Enable Macros to View BoQ information

Other Detail

Information Source https://defproc.gov.in/nicgep/app
Download FileName File Description File Size
Download 8746ATenderdocu.pdf Tender Documents 0 KB
Download a2fbd707-fd11-4431-aef9-cabbee89402e.html Tender Documents 0 KB
Download BOQ_845810.xls Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.