| 1 | True vertical steel tubular swaged pole, 9 metre long, complete with mild steel base plate 6mm thick of size 300mm x 300mm, B-118 finial taper plug, bolts, nuts, washers and screws, type 410 SP-31 including drilling of holes of required size and nuts for fixing of cross arms, painting with two coats of aluminium paint over a coat of red oxide and two coats of black bituminous paint for portion embedded in concrete, painting five black and white bands at lower portion of pole each of 300 mm height at 300mm spacing complete all as specified and directed.(Note : Excavation, earth work and PCC in foundation of poles, coping etc shall be measured and paid separately under respective items of work). |
| 2 | Street light bracket made out of GI tubing 40mm bore, medium grade, 1.5 metre long bent to shape as directed, including suitable 2 Nos MS clamp of MS Flat 50x6mm with MS bolts, nuts and washer fixed to steel tubular pole/PCC pole duly painted with two coats of aluminium paint complete, complete all as specified and as directed. |
| 3 | Factory made PVC pole mounted street light junction box, three phase and neutral, 415 volts, weather proof of size 325x220x150mm depth, accomodated with properly insulated 04 Nos of aluminium busbar of 40 Amps rated current cap, 02Nos of insulator per each busbar, nut bolts & clamps (25x3) for fixing of junction box etc. and including MCB SPN 6 Amps-01 Nos for connecting of security light fittings, with hinged door and locking bolt complete all as specified and directed. Make:-Sintex, Model No : GSJB-3726 or its equivalent make as specified in list of makes. |
| 4 | LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 5 | PVC insulated PVC sheathed multi core flexible cable copper conductor 1100 volts grade conforming to IS-694/2010 of size 1.5 sqmm 3 core including 25mm PVC conduit from junction box to light fittings connecting up complete all as specified and directed by EIC |
| 6 | Dismantling of ACSR conductor any type complete all as specified and directed. |
| 7 | Dismantling of insulators any type complete all as specified and directed. |
| 8 | Supply ,laying, jointing in trenches/floors or passing through pipe/under road and testing XLPE PVC insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 185 sqmm 3.5 core complete all as specified and directed. |
| 9 | All as per item No.8 above but 50 sqmm 3.5 core |
| 10 | All as per item No.8 above but 35 sqmm 3.5 core |
| 11 | All as per item No.8 above but 25 sqmm 3.5 core |
| 12 | All as per item No.8 above but 16 sqmm 4 core |
| 13 | Supply and fixing in repair pole mounted street light timer prewired DB with digital time switch three phase, 440 volts, 50 Hz of 32 Amps capacity including suitable MCB, timer, contactor, ammeter, voltmeter, selector switch (Auto/Manual) alongwith bypass arrangements etc. fitted on pole with 02 Nos of MS clamps including nut, bolt & washers complete with connecting up all as specified and directed by E-in-C. |
| 14 | Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of the earth plate not less than 1.5 m below ground level, connected to GI earth wire 4mm dia by means of bolts, nuts,check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part-I, connected to earth test point all as specified or indicated including excavation and earth work in hard/dense soil, P.C.C 1:3:6 type C-1 as in pit, 15mm bore GI pipe medium grade for watering pipe, 15mm bore GI light grade earth lead protection pipe, 50mm thick precast R.C.C. 1:2:4 type B-1 cover slab of earth pit reinforced with 8mm dia TMT bars @ 10cm C/C both ways and with handle made out of 10mm dia bars, funnel, strainer, including providing alternate layers of common salt and charcoal and testing on completion including dismantling unserviceable earthing complete all as specified and as directed. |
| 15 | All as per item No.14 above but using earth lead as 32x6 mm GI strip complete all as specified and directed. |
| 16 | Bus bar chamber of size 600x600x450mm suitable for 3 phase 433V outdoor type fabricated out of 3.15mm thick MS sheet with 100A rated aluminium busbar 4Nos., PVC sleeves (coloured red, yellow, blue and black) with suitable locking arrangments and four legged angle iron stand made of angle iron of size 40x40x6mm duly grouted in and including foundation in PCC 1:2:4 type B1 (using 20mm graded stone aggregates) alongwith all necesary cable connections, lugs and cable glands including applying two coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrome primer, complete all as specified and as directed. |
| 17 | Feeder pillar box made of angle iron frame of size 50mmx50mmx5mm on all side welded to 3.15mm thick CRCA steel sheet (Outdoor type) with openable shutters on both sides (Front and rear) having locking arrangement totally enclosed weather proof, spray painted internally & externally with two coats of synthetic enamel paint over a coat of primer, danger notice sticker complete suitable for 440 volts, 3 phase, 4 wire, 50 Hz, with properly insulated colour coded aluminium bus bar, AC supply, Current transformer, selector swtch, Volt Metre, Ammeter, LED type indicator lamps, timers, contactors etc. electrically connected complete as per norms and fitted with providing the following switch gears :- (a) Aluminium bus bar of capacity 200 Amps- 1 set 3 Nos phase, 1 No neutral (b) MCCB 200 Amps capacity 35 KA 4P, 415 volt-Nos-01 (incoming) (c) Outgoing- MCCB 150 Amps capacity, 25KA,4P=01 Nos (d) MCCB 63 Amps capacity, 16KA, 4P= 02 Nos (e) MCB SPN 32 Amps= 04 No (f) Digital Ammeter flush pattern type square dial 96x96 mm along with selector switch and suitable CT ratio. (g) Digital voltmeter flush pattern type square dial 96x96 mm along with selector switch |
| 18 | PCC 1:4:8 Type D-2 using 40 mm graded stone aggregate for foundation filling and mass concrete complete all as specified and directed. |
| 19 | PCC 1:2:4 Type B-1 using 20 mm graded stone aggregate for coping of steel tubular poles including necessary formwork and finishing the exposed surface even and smooth without using extra cement complete all as specified and directed. |
| 20 | Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth for foundation etc for shafts, wells,cesspits, man holes, pier holes etc not exceeding 10 sqm on plan and getting out in hard / dense soil, complete all as specified. |
| 21 | Excavation in trenches not exceeding 1.50m wide and for depth exceeding 1.50m in foundation etc for shafts, wells,cesspits, man holes, pier holes etc not exceeding 10 sqm on plan and getting out in hard / dense soil, complete all as specified. |
| 22 | Returning, filling in including spreading, leveling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each,complete all as specified and directed at site |
| 23 | Removing excavated material (soil) to a distance not exc. 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point complete all as specified and directed. |
| 24 | DWC HDPE pipe for protection of power cable (orange in colour) of size 50 mm bore conforming to IS 16098- Part-2 complete with fittings and including cutting, jointing and clamping all as specified and directed. |
| 25 | Cable route indicator, duly engraved with 'LT CABLE 1100 VOLT' on cast iron round plate 100 mm dia with provision of 500 mm long (minimum) single leg/stand of angle iron 50 x 6 mm, welded/riveted on back side of plate, fixed and grounted in position with PCC type C-1, block of suitable size complete.MAKE : JAIPURIA, RAYCHEM, RASHTRIYA. |
| 26 | Supply and fixing in replacement of GI tubing 50mm bore light grade with all fittings for protection of cable at road crossing complete all as specified and directed. |
| 27 | Taking down carefully copper/aluminium point wiring for light, bell socket power socket etc complete with boards, outlet boxes fittings and fixtures such as switchs, sockets, lamp holders bracket, ceiling rose, celing fan etc to match with existing finishes complete all as specified and directed. |
| 28 | Point wiring with 2x1.5 sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable and 1x1.5 sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable as earth continuity to common earth dolly running in and including PVC casing & caping (ISI marked) of suitable size with PVC boards of approporiate size and all requisite accessories such as PVC elbow, Tee, collars, bends etc with PVC terminals box& cover for mounting switches, sockets, fan regulator etc complete all as specified and as directed for the following:- |
| 29 | One light/fan point controlled by one switch complete all as specified and directed. |
| 30 | One 3 Pin switch socket combination 6 Amp on independent board complete all as specified and directed. |
| 31 | One 3 Pin switch socket combination 6 Amp on same board complete all as specified and directed. |
| 32 | One bell/ buzzer point controlled by one push button complete all as specified and directed. |
| 33 | All as per item No. 28 above but with two 2.5 sqmm size cable as phase and neutral and one 2.5 sqmm size cable as earth continuity for 15/20 amp multipurpose socket outlet on independent board complete all as specified and directed. |
| 34 | Sub main wiring with single core cable 2 x 4 sqmm FRLS insulated unsheathed stranded copper conductor cable 1100 Volts grade drawn through PVC casing/caping 25 mm dia ISI marked fixed on wall/ceiling, alongwith 1x2.5 Sqmm FRLS insulated unsheathed copper conductor cable as earth wire connected with main earth dolly , complete all as specified and directed.Note:-Two runs of 4 sqmm cable alongwith one run of 2.5sqmm PVC insulated copper conductor as earh wire incl casing caping shall be measured as one unit. |
| 35 | Switch Piano modular type 5 amp single pole flush type one way complete all as specified and directed. |
| 36 | Switch Piano modular type 15 amp single pole flush type one way complete all as specified and directed. |
| 37 | Switch socket outlet modular type 3 pin 5 amp flush type complete all as specified and directed. |
| 38 | Switch socket outlet modular type 3 pin 15 amp flush type complete all as specified and directed. |
| 39 | Modular white cover plate with frame for 3 module complete all as specified and directed. |
| 40 | Modular white cover plate with frame for 4 module complete all as specified and directed. |
| 41 | Modular white cover plate with frame for 8 module complete all as specified and directed. |
| 42 | Modular metal flush box 3 module complete all as specified and directed. |
| 43 | Modular metal flush box 4 module complete all as specified and directed. |
| 44 | Modular metal flush box 8 module complete all as specified and directed. |
| 45 | Ceiling rose, 3 phase,bakelite 65x50mm two or three therminals complete all as specified and directed. |
| 46 | Modular bell push flush type 5 Amps complete all as specified and directed. |
| 47 | Bell Ding Dong 230 V single phase complete all as specified and directed. |
| 48 | Supply and fix in repairs Electronic step regulator (speed regulation in 5 steps) suitable for ceiling fan 1200 / 1400 mm sweep complete all as specified and as directed. |
| 49 | Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed. |
| 50 | Inverter LED Lamp , CDL 12 Watt , B22 base complete all as specified and as directed. |
| 51 | Supply and fixing in repair Inverter LED light fittings, 1x20 w LED, 230 V complete with all accessories internally per wired including lithium Ion battery with charging time 8-10 hours and back up time upto 4 hours and connecting up with PVC insulated and sheathed, 1100 v grade, flexible, multistranded copper conductor three core cable complete all as directed. |
| 52 | Supply and fixing in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 53 | Decorative wall light gold finish fixture with cognac hammered glass diffuser suitable for 7.5 watt LED filament E27 base complete all as specified and directed. |
| 54 | Distribution board double door type (for incoming MCCB & outgoing MCBs) TPN 4 way vertical sheet steel powder painted with busbar neutral link & earth bar etc. with IP 43 degree of protection flushing in wall including connecting up all incoming and outgoin cables/circuit wiring complete all as specified and directed. |
| 55 | Sheet metal enclosure for MCB distribution board 230 volts single pole and neutral 12 way double door type flushed inside the wall with 200 Amp rated bus bar incl making the surface good complete all as specified and directed. |
| 56 | MCBs SPN 63 amp B curve 240 volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 sqmm terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB complete all as specified and directed. |
| 57 | MCBs SPN 40 amp B curve 240 volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 sqmm terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB complete all as specified and directed. |
| 58 | MCBs SP 5 to 32 amp B curve 240 volts 10 KA finger proof terminal, bi-connect termination, lable holder , 35 sqmm terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB complete all as specified and directed. |
| 59 | Taking down ceiling fan, sealing cable end, dismantling blades and removing fan and blades, complete all as specified and directed. |
| 60 | Rewinding the ceiling fan 1200mm sweep with the same gauge of copper winding wire as well as number of turns and reassembling the fan after replacing the unsv spares like bushes, shafts, fastners, bearing, capacitors and flexible cord for putting fan in serviceable condition including refixing the same after carrying out necessary repairs to orginal place all as directed by E-in-C. |
| 61 | Painting of ceiling fans and writing of MES number on fans in situ with synthetic enamel paint by spraying incl filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed E-in-C. |
| 62 | Ceiling fans complete with three blade, down rod, accessories 230 V, 1200 mm sweep, BLDC fan with 5 star rating incl fan regulator complete all as specified and directed. |
| 63 | Supply and fixing in repairs Exhaust fan, steel body AC single phase, 230 Volts of size 300 mm sweep with, blades and frame and louvers complete all as specified and directed. |
| 64 | Single pole and neutral sheet metal enclosures with a two pin and earth plug and socket 240 Volts, 50Hz complete with one single pole MCB 20 A complete. |
| 65 | Electric water heater, storage type steel body with copper inner tank and heating element upto 1.5 KW capacity, 25 litre, BEE 5 star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc, complete all as specified and directed. |
| 66 | Bus bar chamber of size 600x600x450mm suitable of 3 phases 433V outdoor type fabricated out of 3.15mm thick MS sheet with 400A rated aluminium bus bar 4 Nos, PVC sleeves (coloured red, yellow, blue and black) with suitable looking arrangements and fourr legged angle iron stand made of angle iron of size 40x40x6mm duly grouted in and including foundation in PCC 1:2:4 type C1 using 20 mm graded stone aggregates alongwith all necessary cable connections, lugs and cable glands including applying two coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 67 | Dry Sand cushioning to cables 8cm thick before laying cable and 15 cm thick after laying and testing of cable complete all as specified and directed. Note:- Punned thickness shall be measured and paid. |
| 68 | Supply and laying sub class 'B' bricks laid dry flat transversely along the length of cable with widht equal to the length of bricks over sand cushioning as protection cover of cables complete all as specified and directed. |
| 69 | GI pipe light grade 40 mm bore for cable protection fixed on poles or laid in trenches, under floor, ducts etc with fixing clamps, nuts bolts etc complete all as specified and directed. |
| 70 | Making bore to road/cement path/hard standing/road for providing GI pipe 50mm both end socketed for passing armoured cable incl making good the disturbed surface complete all as specified and directed. |
| 71 | Making bore to road/cement path/hard standing/road for providing GI pipe 40mm both end socketed for passing armoured cable incl making good the disturbed surface complete all as specified and directed. |
| 72 | Energy efficient LED light fitting, 45W, input voltage 110V to 280VAC, 50Hz with ingress protection IP 66, LM 80, stranded luminries with efficiency 100 lumen/watt, with secondary optics, perfectly matched lenses, complying to IEC60598/IS10322, with auto shut down on high voltage, CRI>70, PF>0.95, with short circuit & reverse circuit protection against 10 kV high surges, minimum 25000 burning hours (life), operating temperature 1 to 50 degree Celcius , rectangular shape with pressure die cast aluminium housing with weather proof gasket for lamp and driver compartment with system wattage of 45W=10%W, rated lumens, 120 degree view angle, constant current type driver having THD<10%, including all fixing arrangement like clamps, nuts, bolts, washers, 45W LED rod lamp (having PF>0.9, input voltage 90-300V, IP-66, LM80) with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc including bracket complete all as specified and directed. |
| 73 | Socket outlet 2 in 1, 3 pin 5 amp flush type complete all as specified and directed. |
| 74 | Socket outlet 2 in 1, 3 pin 15 amp flush type complete all as specified and directed. |
| 75 | S&F in repair ceiling mounting LED light fittings luminaire 600mmx600mm,35/36 watt, 220 v, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver , holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor of suitable size complete all as specified and directed. |
| 76 | Sheet metal enclosure for MCB distribution board 230 volts single pole and neutral 8 way double door type flushed inside the wall with 200 Amp rated bus bar incl making the surface good complete all as specified and directed. Please Enable Macros to View BoQ information |