| 1 | Recessed wiring to light point/Fan point/ Exhaust fan point/Call bell point with 1.5sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC flexible conduit with 6Amp ,250V Modular switch ISI marked and ceiling rose ISI marked mounted on Metal box having front Modular cover of suitable size, Metal box with 1.5sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection (Make of wire-Polycab/Finolex/L&T/Anchor/Havells/V-Guard) Group-A -L.P- F.P- C.B.P- |
| 2 | Group-B L.P- F.P- C.B.P- |
| 3 | Group-C L.P- F.P- C.B.P- |
| 4 | Supply and fixing of 4 no.s of 3pin 5/6 amp modular socket and S.P. 5/6 amp one way modular switch, modular switch (4 nosX 5A S-S) on Modular G.I. Box with Modular Base and cover(make-Havells/ Anchor/ Legrand /Roma/panasonic) |
| 5 | Recessed submain wiring alongwith earth wire with the following sizes of PVC insulated single core multistrand copper conductor ISI marked conforming to IS-694/1990 in 20mm dia non metallic heavy duty flexible conduit 1.6 mm in surface /recessed PVC conduit as required (make of wire -Polycab/Finolex/L&T/Anchor/Havells/V-Guard/) 2 X 1.5sq.mm +1 X 1.5sqmm |
| 6 | 2 X 2.5sq.mm +1 X 1.5sqmm |
| 7 | 2 X 4sq.mm +1 X 1.5sqmm. |
| 8 | Re-wiring for light point/fan point/exhaust fan point/call bell point with 1.5sqmm FR PVC insulated single core multistrand copper conductor ISI marked and 1.5sqmm FR PVC insulated copper conductor single core multistrand copper conductor in existing surface recessed PVC/STEEL conductor including dismantling as required. Group-A -L.P- F.P- C.B.P- |
| 9 | Group-B L.P- F.P- C.B.P- |
| 10 | Group-C L.P- F.P- C.B.P- |
| 11 | Supply and drawing of following size PVC insulated single core multistrand copper conductor in existing surface/recessed/ steel /pvc conduit as required. 3 X 1.5sqmm |
| 12 | Supply and fixing of superior type call bell of ISI marked, on 6\\" X 4\\"conforming to IS-2268/1994 and bell push of ISI marked , conforming to IS-1293/ 1988 (make-Cona/ Anchor) Musical Call bell with battery |
| 13 | Supply and fixing of copper plate earthing( 600 X 600 X 3.15mm )with running copper flat 25 X 5mm from copper plate to funnel of 40mm dia G.I pipe including all accessories |
| 14 | Providing and fixing 8 SWG (4 mm) dia copper wire on surface or in recess for loop earthing as required |
| 15 | Supply and fixing of following way single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) make-Hager/Havells/Legrand/Anchor/schnider 8way, Double door |
| 16 | Supply and fixing of 5Amp to 32A rating 240V \\"B\\" series MCB suitable for lighting and other loads of the following poles in the exiting MCB DB ISI marked complete with connections testing and commissioning etc. as required. (make-Hager/Havells/Legrand/Anchor/schnider single poles MCB LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 Single pole (SP) |
| 17 | Single pole and Neutral (SP&N) |
| 18 | s/F of Type 1+2 AC Surge Protection Devices,(SPD) High Discharge Current : Imax 50 kA (L N)70 kA (N E),Compact Size : Integrated Type-1 & Type-2 protection in small module width. Ideal in all reduced-size plants. Protection : Voltage protection level 1.5 kV, The multi-pole single-piece surge arrester range is adapted for TT, TN-S, TN-C earthing systems. . The Uc maximum continuous operating voltage in common mode is 260VAC between neutral and earth, and is 340VAC between phase and earth. |
| 19 | Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, 2P, 240 volts, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 3 years. |
| 20 | 63Amp kit kat |
| 21 | Supply ,installation, testing and commissioning of main switches (IS 13940 part-3/1993 ) of following capacity on existing surface/wall mounting and complete with HRC fuse links, interconnections, earthing etc. as required (Make-Seimens/Hager/Havells/Legrand/Anchor/schnider 63Amp ICDP main switches with MS board |
| 22 | 63Amp ICTPN Main switch on MS angle frame |
| 23 | Supply and fixing of copper bus bar with suitable sheet metal enclosure on MS angle frame with proper grouting on wall including all connections. 63Amp TPN bus bar -300 X 25 X 3mm size |
| 24 | 100Amp TPN bus bar-300 X 32 X 3mm size |
| 25 | Supply and fixing of 9Watt LED lamp , Lumens Efficacy minimum rating should meet :105 lumen per watt 6500k (Philips/ Havells/ AnchorBajaj) |
| 26 | Supply and fixing of 10 watt Mirrior light with all connections. , Lumens Efficacy minimum rating should meet :105 lumen per watt 6500k(Make-Havels/Panasonic/ Philips/Bajaj/Crompton) |
| 27 | S/F of 20W 4' LED fitting Surface LED Light fitting , Lumens Efficacy minimum rating should meet :105 lumen per watt 6500k (Make-Havels/Panasonic/ Philips/Bajaj/Crompton |
| 28 | S/F of 36W 2'X2' Surface/recessed on Ceiling LED fitting , Lumens Efficacy minimum rating should meet :105 lumen per watt 6500k (Make-Havels/Panasonic/ Philips/Bajaj/Crompton) |
| 29 | S/F of 18Watt White Circular/Square Surface LED fitting , Lumens Efficacy minimum rating should meet :105 lumen per watt 6500k (Make-Havels/Panasonic/ Philips/Bajaj/Crompton) |
| 30 | S/F of 60W LED street light fitting , Lumens Efficacy minimum rating should meet :105 lumen per watt 6500k(Make-Havels/Panasonic/ Philips/Bajaj/Crompton) |
| 31 | S/F of 90W LED street light fitting , Lumens Efficacy minimum rating should meet :105 lumen per watt 6500k (Make-Havels/Panasonic/ Philips/Bajaj/Crompton) |
| 32 | S/F of 3 watt LED SPOT Light round surface Fitting swivel modular, Lumens Efficacy :80 lumen per watt 6500k (Make-Havels/Panasonic/ Philips/Bajaj/Crompton) |
| 33 | S/F LED 30 watt Bollard in IP 67 Garden Trident Canopy Outdoor light fitting For Garden, Pathways & Landscape Lighting Large (Make-Havels/Panasonic/ Philips Bollard Light - |
| 34 | S/F of 40watt LED Gate light Aesthetically designed IP65 comprises of spun aluminium top cover,die cast aluminium with frosted polycarbonate cast alumium mounting base arm fitting Make-Panasonic/Philips / Havells/Eq.ModelPPTM02408R1 |
| 35 | Supply and fixing of Geyser(6 ltr INSTANT GEYSER) 5-star BEE energy efficiency ratings, high-pressure resistance (often 8 bar), and advanced safety features including auto-cutoff and thermal cut-out make- Havells,RACOLD,Orient, Ao smith,Vgurd/Crompton |
| 36 | Supply and fixing of Geyser(10ltr) 5-star BEE energy efficiency ratings, high-pressure resistance (often 8 bar), and advanced safety features including auto-cutoff and thermal cut-out make- Havells,racold,Orient, Ao smith,Vgurd/Crompton |
| 37 | Supply and fixing of changeover switch (Anchor/ Havells/ Apex) 63Amp double pole |
| 38 | S/F of 1200mm Brush Less Direct Current BLDC Ceiling fan with Low wattage consumption fan , Heavy Duty,durable, copper winding,Aluminium blade(ISI mark)Crompton Grave/Khaitan/Havells/Orient/Polycab/V-Guard |
| 39 | Exhaust fan 300mm |
| 40 | Wall mounted fan 400mm High speed low noise oscilation, make- Andrila wall fan havells/Khaitan/Almonard/Orient |
| 41 | Supply of PVC/XLPE Aluminium armored cables ISI marked.(Make- GLOSTER/Havells/Anchor. 4sq.mm 2core |
| 42 | 10sq.mm 4core |
| 43 | 25sq.mm 3 1/2 core |
| 44 | 1.5sq.mm 3core |
| 45 | Cable laying on wall surface with steel shaddle 25sqmm |
| 46 | 3.5C x 35 sq.mm |
| 47 | 4 C x16 sq.mm |
| 48 | S/F of 4KVA voltage stabiliser (CG/Shakti/V-guard/Autotac)(I/p-130V to 270V, O/P-200V to 240V) |
| 49 | Supply of Invertor,UPS 1650VA Pure Shine wave (Make Microtech/Su-kam/Luminous/Crompton) |
| 50 | Supply of Invertor Battery 12V 150AH(Make Exide/Amrom/Su-kam/Luminous/Crompton with 48 Month warranty) |
| 51 | Supply of Invertor Stand(Make Microtech/Su-kam/Luminous/) Please Enable Macros to View BoQ information |