Tender For Construction Of Additional Classroom At Gdc Sarh Bagga Mahore

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 24-03-2026 Date Date 25-03-2026

Key Dates

Publish Date 24-03-2026
Last Date of Bid Submission 25-03-2026
Tender Opening Date 27-03-2026

Contact Information

Company Name Public Works Department
Contact Person EE Mahore
Address Mahore

BOQ Items

Name of Work:- Construction of Additional classroom at GDC Sarh Bagga Mahore
Sl. No. Item Description
1Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metre All kinds of soil :
2Providing and Laying of hand packed stone boulders size ( 150mm - 230 mm ) before laying of mud mat compacted consolidated rammed filling the voids compacting all complete including carriage.
3Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) all complete including carriage
4Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) all complete including carriage
5Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) all complete including carriage
6Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts,Rcc slab , beams , foundation Raft upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) all complete including carriage
7Centering and shuttering including strutting, propping etc. and removal of form for: Strip foundation
8foundation beam
9Coloumns 1st and 2nd floor
10plinth beam
11floor beam first and second floor
12suspended floor
13stair case
14Edges of slabs and breaks in floors and walls Under 20 cm wide
15PCC Wall
16Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
17Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded
18Providing and fixing bolts including nuts and washers complete.
19Supplying and filling in plinth with fine sand under floors including watering , ramming, consolidating and dressing complete.
20Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) including Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level including all carriage complete.
2112mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand)
2215mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand)
23Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven storey height made with 40 mm dia M.S. tube 1.5 m centre to centre horizontal and vertical tubes joining with cup and lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffoldings for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding.
24Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm)
256 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand)
26Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1 mm thick
27Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work
28Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
29Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 25mm thick with 12.5 mm nominal size stone aggregate.
30Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm
31Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) Polyester powder coated aluminum (minimum thickness of polyester powder coated 50 microns) 50x50 mm section.
32Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board (conforming to IS: 12823 Grade-I type-II) in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-incharge. Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side.
33Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin-charge. (Cost of aluminum snap beading shall be paid in basic item.)
34Flooring with marble stone of specified thickness as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement:4 coarse sand) laid and jointed with grey cement slurry including rubbing, polishing and curing complete with: Black zebra
35Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete
36Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.63 mm thick with zinc coating not less than 275 gram/m2
37Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete. 0.63 mm thick with zinc coating not less than 275 gram/m2
38Providing and fixing plained eaves boarding. 2nd class kail wood 250x32 mm (nominal size )
39providing and fixing of 19mm thickness soffit of budloo wood specifications including jam work ( 1.50\\" x 3\\" ) of budloo wood underneath complete.
40Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
41Making soak pit 2.5 m diameter 3.0 meter deep with 45x45 cm dry brick honey comb shaft with common burnt clay (non modular) bricks of class designation 7.5 bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
42constructing brick masonry chamber in cement mix 1:4 collection chamber 750 x 750 internal size and 600mm deep fixed with CI Cover and frame 750 x 750 mm including 12mm plaster in 1:3 mix including all carriage complete.
43Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid.
44Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps.
45Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:
46Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
47Providing and fixing PVC ( B Type ) fitting of approved brand and quality roved brand and manfacture. 100 mm PVC double equal door Tee
48110 mm PVC double equal door Tee
4975 mm PVC Collar
50110 mm PVC Collar
51PVC Reducer 100 x75 mm
5275 mm dia Slotted Cowl
53PVC Pipe 75 mm diametre
54PVC Pipe 110 mm diametre
55PVC Pipe 75 mm bend
56PVC Pipe 110 mm bend
57Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete Semi rigid pipe 32 mm dia
58Providing and fixing 100 mm sand cast iron grating for gully trap.
59Providing and fixing toilet paper holder C.P. brass
60Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.: Internal work-Exposed on wall 15 mm dia. nominal bore
6120 mm dia. nominal bore
6225 mm dia. nominal bore
63Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. (external work) 15 mm dia. nominal bore
6420 mm dia. nominal bore
6525 mm dia. nominal bore
66Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) 25 mm nominal bore
67Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing Tee, including cutting and threading the pipe etc. complete 25 to 40 mm nominal bore
68Providing and fixing brass bib cock of approved quality. 15 mm nominal bore
69Providing and fixing brass bib cock of approved quality. 20 mm nominal bore
70Providing and fixing brass stop cock of approved quality 20mm
71Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.
72Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931
73Providing and fixing 15 mm nominal bore of standard back type C.P. brass close hole basin mixer pillar tap of approved quality and make, weighing not less than 1.970 kg.
74Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms.
75Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighing not less than 88 gms.
76Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 610x460mm bowl depth 200mm
77Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 453x357 mm
78Supply,installation and commissioning of 1.5 HP motor pump (submerssible) including all necessary fitting and fixture to inlet and outlet supply complete job.
79Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group-A
80Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loopearthing as required.
81Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
822 X 6 sq. mm + 1 X 6 sq. mm earth wire
832 x 10 sq. mm + 1x 6 sq. mm earth wire
84Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required.1 x 1.5 sq. mm
85Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
86Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
873 pin 5/6 A socket outlet
8815/16 A switch
896 pin 15/16 A socket outlet
90Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
91Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
92Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
93Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc. 6 way ( 4+18), (Double door) (TPN type)
94Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISImarked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947- 2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. ,conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. Single pole 6/10/16/32 Amp
95Single pole and neutral 32 Amp
96SPN 40 Amp
97SPN 63 Amp
98Supplying, Installation, Testing & Commissioning of 18 WATT LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver &electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained tilllife ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (StandardDeviation Colour Matching) <3, Maximum power consumption should not more than the specifiedrating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ NameEngraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connectionswith 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc.as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Wattoutput . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall besubmitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junctiontemperature shall not rise above 90°C) Powder coated die cast /Extruded aluminiumBody including trim
99Supplying, Installation, Testing & Commissioning of 18- 22 Watt LED surface mounted Batten light of following body material and construction as per IS : 10322 withdriver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductorsingle core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management:heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
100S&f of Mirror light LED fitting with 9/11W LED lamp
101Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
102Supplying and fixing of following electrical items suitable for operating on 240/230Volts AC, 50 Hz supply. including connections etc. as required. Ceiling fan 1200 mm sweep alongwith rod upto 1'-6\\" long (3 Star)
103Exhaust fan 300 mm size (Metalic)
104Supplying, installation, Testing & Commissioning of 72 watt Street light LED fixture powder coatedpressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%,Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the roadand the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electricalcircuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life endsas per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As perANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumptionshould not more than the specified rating and Fixture shall be of relevant BIS standard completein all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copperconductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing requiredfor LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved byEngineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housingsuch that LED junction temperature shall not rise above 90°C).
105Supply, installation, testing & commissioning of maintenance free copper earthing system with 3 mtrs. Electrode 40 mm dia with minium 2mm thick and does not require manual additional of water. The electrode shall be pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. the electrode shall be surrounded by suitable powdered form of BEE MOIST so as to provide maximum contact between the electrode and the compund. The compound should be eco-friendly The earthing pit should be covered with PVC cover.
106Providing and fixing of 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required.
107Providing and fixing 4.00 mm dia copper wire on surface or inrecess for loop earthing as required.
108Supplying, Installation, Testing & Commissioning of inverter 2000 VA along-with 2 Nos. long tubular batteries 150 AH and trolly of suitable size.
109SITC of wall/free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgear c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar (> 125). (d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge.
110Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type, Adjustable type) 100 Amp, 30 KA, FP MCCB ICU = 100% ICS
111Aluminium Bus Bar 200 Amp set of 4 strips 18\\"
112Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc.
113Supplying & laying of PVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) 50 sq. mm 3.5 core
114Supplying, installation, testing and commissioning of following type of water purifiers alongwith PVC connecting pipes as required. (RO + UV + UF mineral control with TDS control ) Please Enable Macros to View BoQ information

Other Detail

Information Source https://jktenders.gov.in
Download FileName File Description File Size
Download 508b21c9-dcd4-4ace-bce6-fb1724f40b8c.html Tender Documents 0 KB
Download BOQ_991120.xls Tender Documents 0 KB
Download Tendernotice_1 (1).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.