Tender Brief Tender For maintenance of electrical installation & Fans , Street Light , Compound Light And repair maintenance Pump Set Installed At I.T.I Malviya Nagar, Under Ae(E)-Ii-M-South During The Year 2025-26 (Sh- Supplying, Installation, Testing & Commissi
City Delhi
State Delhi
Document Fees Refer document
EMD INR 11581.0 /-
Tender Value INR 5.79 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for maintenance of electrical installation & Fans , Street Light , Compound Light And repair maintenance Pump Set Installed At I.T.I Malviya Nagar, Under Ae(E)-Ii-M-South During The Year 2025-26 (Sh- Supplying, Installation, Testing & Commissioning Of Plant Automatization & Management System With Microprocessor Based Control Panel, Online Monitoring, Wireless Connectivity With Complete Scada Software For Drinking Water And Raw Water In Iti Malviya Nagar, New Delhi)

Key Dates

Publish Date 02-03-2026
Last Date of Bid Submission 09-03-2026
Tender Opening Date 09-03-2026

Contact Information

Company Name Public Works Department
Contact Person Assistant Engineer (E) SD-II
Address The Assistant Engineer (E) PWD EMSD II M SOUTH, Hauz Khas, New Delhi

BOQ Items

Name of Work:- MOEI & Fans , Street Light , Compound Light and RMO Pump Set installed at I.T.I Malviya Nagar, under AE(E)-II-M-South during the year 2025-26 (SH- Supplying, installation, testing & commissioning of Plant Automatization & Management System with Microprocessor based control panel, online monitoring, wireless connectivity with complete Scada Software for Drinking Water and raw water in ITI Malviya Nagar, New Delhi)
Sl. No. Item Description
1Supplying, installation, testing & Commissioning of PUMP House Automation Electrical Panel, wall mounted indoor cubical Panel duly powder coated having suitable size for switchgear and accessories. The panel has to be fabricated from 1.6 mm thick CRCA sheet duly compartmentalized suitable for 415 volt 50Hz A.C supply of suitable size with control wiring in channel, MCB, Relay card channel, Terminal Block, Panel Control Wiring & Panel Stand i/c supplying and fixing of following accessories in panel complete as reqd.1.1) Cooling fan 4\\" - 1 Nos. 1.2) SPMCB 6-32 Amp. - 2 Nos. 1.3) 32 Amp TPN - 1 Nos. 1.4) Relay card 8 Channel - 3 Nos. 1.5) Push Button Flush Head - 12 Nos. 1.6) Contact Blocks - 30 Nos. 1.7) Push Button & Selector Actuators © 22.5 mm - 3 Nos. 1.8) SMPS 12 VDC 6 Amp. - 2 Nos. 1.9) SMPS 24 VDC 4.5 Amp. - 1 Nos. 1.10) Indicator Gen Next LED 8531 22.5 mm - 15 Nos. 1.11) Panel Light. - 1 Nos. 1.12) \\"Modular AC Box With 20A SP MCB, Plastic Enclosure 8 Unbreakable Heavy Duty With ISI Plug Top - 1 No.
21.13) MMU (Master Microprocessor Unit) With Smart Graphical Display Size 7\\" Inbuilt Software Application with wireless connectivity for all wireless device communication & cloud communication with wireless connectivity, Current transformer to be installed in pump house with following accessories listed below: Micro Processor Unit shall have control, protection & live data devices up to 6 Pumps 10 Sensor Micro Processor Fast Fourier transformation to eliminate harmonics &, Surges True RMS measurements & simultaneous sampling of Volts, Amps 2 layer protection & each 1/0 controller protected with a single form factor for multiple technologies high performance & accuracy with real time clock wireless connectivity compatible, data backup, various functions high Speed mode with instant switches from one input to the other & can be controlled in slot for memory with concocted to external devices like android/os/windows platform & Pe through software key - CGPS plug - in software. Software key should comprised of UDP/ FTP/HTTP open standard Internal Expansion Wireless CPUR: with an core ARM7 32- bit floating point (72 MIZ max) microprocessor, with integrated IDE & GPRS connection with Uptime - Minimum 95%, Download Speed up to -4 Mbps Transtar unlimited of all measured parameters/ quantity/ Auto Scrolling Password protected user programmable Parameters Fault Indication at display Access Point etc. - 1 No
3Supplying installation testing & commissioning of Ultrasonic Sensor status of water tank output analog approx. liquid Quantity in tank, made of ABS housing, detection range not less than 2 meters, output analog approx, liquid quantity in Tank, etc. complete as required.
4Supplying, installation, testing & commissioning of microprocessor, suitable with control & wireless connectivity device transmitter and receiver (To be installed nearby sensor & line pressure transmitters for wireless data Range upto 1000 meters i/c sending data from upward to downward) for sending status of water tank to Master Microprocessor unit of on real time basis, for sending/receiving data from SCADA. Made of ABS Housing, Control :- Relay Based output & Display at 50 Level Water in tank indicator with suitable control panel operated at SPMCB 6 AMP. 230V single phase 50 Hz AC supply etc. complete as required.
5Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
62 X 6 sq. mm + 1 X 6 sq. mm earth wire Please Enable Macros to View BoQ information

Other Detail

Information Source https://govtprocurement.delhi.gov.in
Download FileName File Description File Size
Download 02874cc5-3968-4586-b355-8c28b8c6e45a.html Tender Documents 0 KB
Download BOQ_381894.xls Tender Documents 0 KB
Download fullnithauzkhas.pdf Tender Documents 0 KB
Download Tendernotice_1 (1).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.