Indian Tenders

Tender Notice

TDR 54398534
Tendering Authority Local Self Government Department
Tender No AE/KLPT/TR/05/2025-26
Tender ID 2026_LSGD_842948_11
Tender Brief Tender For Annual Plan-Electrification Of Kalappurakkal Unnathi Padana Veedu, Kalpetta Municipality.-S0631/26-General Electrical Work
City Kalpetta
State Kerala
Document Fees INR 555 /-
EMD INR 2165.0 /-
Tender Value INR 86603.0 /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Annual Plan-Electrification Of Kalappurakkal Unnathi Padana Veedu, Kalpetta Municipality.-S0631/26-General Electrical Work

Key Dates

Publish Date 05-03-2026
Last Date of Bid Submission 10-03-2026
Tender Opening Date 11-03-2026

Contact Information

Company Name Local Self Government Department
Contact Person ME
Address KALPETTA MUNICIPALITY

BOQ Items

Name of Work:- Annual Plan-ELECTRIFICATION OF KALAPPURAKKAL UNNATHI PADANA VEEDU, KALPETTA MUNICIPALITY.-S0631/26-General Electrical Work
Sl. No. Item Description
1ELECTRIFICATION
21.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C
31.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
41.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
51.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
61.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
71.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
81.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
91.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
10OD461382/2025-2026:Supply and fixing of 9W LED Bulb.
11OD461377/2025-2026:Supply of Die cast Al housing 9W/700lmn LED bulkhead having IP65 protection.
121.41:Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
1390.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
141.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1590.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
161.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
171.56:Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
181.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
191.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
202.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door
212.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
222.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
232.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Double pole
245.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
25OD461383/2025-2026:Providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthing system.
265.9:Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
275.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
282.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required.
29OD461376/2025-2026:Supply and installation of dust and vermin proof Three-phase sintex meter board (GS MB-5345) 530x450x75 mm and to fix KSEB meters, fuse unit, CTs, etc. as required including fixing it on the wall, making good the damages, color washing, etc. as required.
30OD461378/2025-2026:Supply and fixing 32 A, 2 Way Bakelite neutral links mounted on DMC/SMC base
31OD461381/2025-2026:Supply and fixing of 32 ampere Bakelite HRC fuse with HRC fuse-link with connections inexisting meter board.
32OD461379/2025-2026:Supply and installation of 10mm or nearest size hook type anchor bolt.
331.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm Please Enable Macros to View BoQ information

Other Detail

Information Source https://etenders.kerala.gov.in
Download FileName File Description File Size
Download 631SBD.pdf Tender Documents 0 KB
Download BOQ_1423104.xls Tender Documents 0 KB
Download e6d36313-efcd-4c86-b89e-0b424e4d2125.html Tender Documents 0 KB
Download Tendernotice_1 (1).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.