Indian Tenders

Tender Notice

TDR 54388462
Tendering Authority Public Works Department
Tender No WBPWD/SE/SWEC/NIQ49/2025-26
Tender ID 2026_WBPWD_1017935_1
Tender Brief Corrigendum : Tender For Construction (Civil + Electrical ) Of A New Two Pump Fire Station (G+1 Storied Building With Foundation Of G+3 Storied Building ) At Manbazar In Purulia District--- Supply Installation Testing and Commissioning of Air-Conditioning System
City Purulia
State West Bengal
Document Fees Refer document
EMD INR 5939.0 /-
Tender Value Refer document
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Construction (Civil + Electrical ) Of A New Two Pump Fire Station (G+1 Storied Building With Foundation Of G+3 Storied Building ) At Manbazar In Purulia District--- Supply Installation Testing and Commissioning of Air-Conditioning System

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 15-03-2026 DATE CORRIGENDUM Date 23-03-2026

Key Dates

Publish Date 15-03-2026
Last Date of Bid Submission 23-03-2026
Tender Opening Date 25-03-2026

Contact Information

Company Name Public Works Department
Contact Person SUPERINTENDING ENGINEER, SWEC, PWDte
Address OFFICE OF THE SUPERINTENDING ENGINEER (P.W.Dte) South-Western Electrical Circle PWD Compound,Midnapore,Paschim Medinipur

BOQ Items

Name of Work:- Construction (Civil + Electrical ) of a new two pump fire station (G+1 storied building with foundation of G+3 storied building ) at Manbazar in Purulia District--- SITC of Air-Conditioning System
Sl. No. Item Description
1Supply and delivery of Fixed Speed 220V, 50Hz, Single Phase (with applicable tolerance) Room Air Conditioner fitted with rotary compressor and copper condenser and cooling coil having the following major specifications: Refrigerant R410A/R32, Capacitor Type P2, minimum cooling capacity 3.5 kW or higher based on latest ISEER rating 3.92 (BEE: 2 Star/2026) or higher, maximum power consumption 1360 Watts or less, minimum tonnage 1.1 TR (as per manufacturer’s standard) or higher with other modern features, and minimum room discharge air flow 550 CFM or higher.The unit shall be capable of operating satisfactorily at an ambient temperature of 50°C or higher.The unit shall comply with all latest amendments and modifications of IS 1391 (Part-I) and shall be supplied complete with remote control, necessary connection kit, piping kit and all standard accessories as provided with Outdoor Unit (ODU) and Indoor Unit (IDU) as per manufacturer’s standard. Make: Fujitsu General – ASGA14BMAA-B (R32) or equivalent model of Mitsubishi Heavy Industries / Mitsubishi Electric complying with the above specifications. [Standard warrenty by OEM should be provided for Machine 1Year or more , For Compressor 5 Years or more]
2Supply and delivery of Fixed Speed 220V, 50Hz, Single Phase (with applicable tolerance) Room Air Conditioner fitted with rotary compressor and copper condenser and cooling coil having the following major specifications: Refrigerant R410A/R32, Capacitor Type P2, minimum cooling capacity 5.2 kW or higher based on latest ISEER rating 3.84 (BEE: 2 Star/2026) or higher, maximum power consumption 1450 Watts or less, minimum tonnage 1.5 TR (as per manufacturer’s standard) or higher with other modern features, and minimum room discharge air flow 777 CFM or higher.The unit shall be capable of operating satisfactorily at an ambient temperature of 50°C or higher. The unit shall comply with all latest amendments and modifications of IS 1391 (Part-I) and shall be supplied complete with remote control, necessary connection kit, piping kit and all standard accessories as provided with Outdoor Unit (ODU) and Indoor Unit (IDU) as per manufacturer’s standard. Make: Fujitsu General – ASGA18BMAA-B (R32) or equivalent model of Mitsubishi Heavy Industries / Mitsubishi Electric complying with the above specifications. [Standard warrenty by OEM should be provided for Machine 1Year or more , For Compressor 5 Years or more]
3Supply and delivery of Fixed Speed 220V, 50Hz, Single Phase (with applicable tolerance) Room Air Conditioner fitted with rotary compressor and copper condenser and cooling coil having the following major specifications: Refrigerant R410A/R32, Capacitor Type P2, minimum cooling capacity 7.0 kW or higher based on latest ISEER rating 3.81 (BEE: 2 Star/2026) or higher, maximum power consumption 1800 Watts or less, minimum tonnage 2.0 TR (as per manufacturer’s standard) or higher with other modern features, and minimum room discharge air flow 777 CFM or higher.The unit shall be capable of operating satisfactorily at an ambient temperature of 50°C or higher. The unit shall comply with all latest amendments and modifications of IS 1391 (Part-I) and shall be supplied complete with remote control, necessary connection kit, piping kit and all standard accessories as provided with Outdoor Unit (ODU) and Indoor Unit (IDU) as per manufacturer’s standard. Make: Fujitsu General – ASGA24BMAA-B (R32) or equivalent model of Mitsubishi Heavy Industries / Mitsubishi Electric complying with the above specifications. [Standard warrenty by OEM should be provided for Machine 1Year or more , For Compressor 5 Years or more]
4Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for the system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required [Cu. Pipe Make : Nippon/Mandev/Ryoku][Insulation Make-K-Flex/Accroflex/Suprime]
56.35 mm dia (OD)with tube thickness0.8mm with 9mm thick nitrile insulation for liquid line for 2/1.5/1 Tr split AC Machine
615.9 mm dia (OD) with tube thickness 0.8 mm with 9 mm thick insulation for suction line for 2/1.5 Tr split AC machine
7Supply, laying and termination of 1.1 kv grade following size PVC insulated PVC sheathed unarmoured Copper Cable (Make:-Finolex/Havells/Polycab) Control Cabling from Condensing Unit to control panel
8a) 4 core 2.5 sq.mm communication cable
9Installation Testing and Commissioning of wall mounted fixed speed split Air-Conditioners by making scaffolding arrangement as per site condition, incl.Supply & Charging of necessary Refrigerant, Outdoor brackets for holding and fixing the ODU, plates for fixing the IDU and connecting Control & power cabling & other necessary materials to complete the job.
10Supply & Installation of 6mm Nitrile Rubber insulated PVC / HDPE pipes of following sizes with fitting, accessories, bends, elbows, tees, flanges, U-trap, wall sleeves, hangers, supports, anchors etc for draining condensate water from indoor unit to the nearest drain point.[Make-Finolex/Suprime/Astral]
11a) 25 mm dia
12Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy.Connections Please Enable Macros to View BoQ information

Other Detail

Information Source https://wbtenders.gov.in/nicgep/app
Download FileName File Description File Size
Download 4883666c-1640-4974-93b8-6d52d4ac54e7.html Tender Documents 0 KB
Download BOQ_2501494.xls Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Download Tendernotice_2.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.