Indian Tenders

Tender Notice

TDR 54386886
Tendering Authority Water Resources Department
Tender No 1204/6A
Tender ID 2026_WR_159566_2
Tender Brief Corrigendum : Tender For Supply, Installation, Commissioning, And 5-Year Operation & Maintenance Of 200 Hp Pump Sets, Vacuum Pumps, Valves, Pipes, And Electrical Panels For Lifting Water From Sirhind Canal Rd 145700/R Into Neelon Drain
City Ludhiana
State Punjab
Document Fees INR 15000 /-
EMD INR 3180000.0 /-
Tender Value INR 15.90 Crore /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Supply, Installation, Commissioning, And 5-Year Operation & Maintenance Of 200 Hp Pump Sets, Vacuum Pumps, Valves, Pipes, And Electrical Panels For Lifting Water From Sirhind Canal Rd 145700/R Into Neelon Drain

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 02-04-2026 corrigendum02042026 Date 06-04-2026
2 01-04-2026 corrigendum01042026 Date 02-04-2026
3 30-03-2026 corrigendum30032026 Date 01-04-2026
4 30-03-2026 corrigendum30032026 Date 01-04-2026
5 27-03-2026 corrigendum27032026 Date 30-03-2026
6 27-03-2026 corrigendum27032026 Date 30-03-2026
7 25-03-2026 corrigendum25032026 Date 27-03-2026
8 25-03-2026 corrigendum25032026 Date 27-03-2026
9 25-03-2026 corrigendum25032026 Date 27-03-2026
10 24-03-2026 corrigendum24032026 Date 25-03-2026
11 24-03-2026 corrigendum24032026 Date 25-03-2026
12 24-03-2026 corrigendum24032026 Date 25-03-2026
13 24-03-2026 corrigendum24032026 Date 25-03-2026
14 21-03-2026 corrigendum21032026 Date 24-03-2026
15 21-03-2026 corrigendum21032026 Date 24-03-2026
16 21-03-2026 corrigendum21032026 Date 24-03-2026
17 21-03-2026 corrigendum21032026 Date 24-03-2026
18 20-03-2026 corrigendum20032026 Date 21-03-2026
19 20-03-2026 corrigendum20032026 Date 21-03-2026
20 20-03-2026 corrigendum20032026 Date 21-03-2026
21 20-03-2026 corrigendum20032026 Date 21-03-2026
22 20-03-2026 corrigendum20032026 Date 21-03-2026
23 19-03-2026 corrigendum19032026 Date 20-03-2026
24 19-03-2026 corrigendum19032026 Date 20-03-2026
25 19-03-2026 corrigendum19032026 Date 20-03-2026
26 19-03-2026 corrigendum19032026 Date 20-03-2026
27 17-03-2026 corrigendum17032026 Date 19-03-2026
28 17-03-2026 corrigendum17032026 Date 19-03-2026
29 17-03-2026 corrigendum17032026 Date 19-03-2026
30 17-03-2026 corrigendum17032026 Date 19-03-2026
31 17-03-2026 corrigendum17032026 Date 19-03-2026

Key Dates

Publish Date 02-04-2026
Last Date of Bid Submission 06-04-2026
Tender Opening Date 06-04-2026

Contact Information

Company Name Water Resources Department
Contact Person xen ldh drainage
Address XEN LUDHIANA DRAINAGE

BOQ Items

Name of Work:- Supply, Installation, Commissioning, and 5-Year Operation & Maintenance of 200 HP Pump Sets, Vacuum Pumps, Valves, Pipes, and Electrical Panels for Lifting Water from Sirhind Canal RD 145700/R into Neelon Drain
Sl. No. Item Description
1Supply of 200 HP PUMP pump casting CI ,impeller: CF8M,SHAFT:SS-410 SUCTION COVER :SS (PUMP+MOTOR+BASEFRAME+COUPLING+COUPLING GUARD)
2VACCUM PUMPSET water ring type vacuum pump model DV 50 having 50 mm suction, 50 mm delivery coupled on common ms fabricated base frame through suitable flexible coupling /CGL/ABB make (at our option) 10HP, 1450 RPM, TEFC, sq. cage induction motor suitable for operation on 415V, 50hz, 3pha.c. supply.
3Supply Of (CAST STEEL GATE Valve (Suction side-Pump-1 800 MM RATING CL-150
4Supply Of CAST STEEL CHECK VALVE (Suction side-Pump-1) 800 MM CL-150
5Supply Of CAST STEEL GATE Valve (Delivery side-Pump-1) 700 MM CL-150
6Supply Of CAST STEEL CHECK VALVE (Delivery side-Pump-1) 700 MM CL-150
7Supply Of TEMPERPROOF KINETIC AIR RELEASE VALVES P.N 1.6
8Supply of MS PIPE SIZE 800 MM SUCTION PIPE
9Supply of MS PIPE SIZE 700 MM DELIVERY PIPE
10Supply of MS PIPE SIZE 1000 MM RISER MAIN
11Providing and fixing premium make LT panel (TTA Type) having 4000A Four Pole ACB, 50kA with display including 8 nos VFD-200 HP Heavy Duty with in built choke with bypass star-delta option for Riser-1,2,3 & 4 having suitable contractors, digital ECOR, phase sequence relay, suitable rating MPCB/MCCB and 8 nos DOL - 5HP starter (with suitable rating of MPCB) Vaccune Pump. Isolation/Control Transformer of rating - 250VA , 415/230 Volt (for individual feeder) for control supply. Feeders for Lighting Load included. As per specification document (enclosed) with UPS of suitable capacity (3 KVA) with 6 hrs battery backup. The panel should be PLC controlled with IPC atleast 19 inch size.
12APFC Capacitor Panel of atleast 1000KVAR having APFC relay with detuned reactors and capacitor duty contactors.
13Earthing and Erection & installation & commissioning (above Proposed items) work having cabling between motors and panels, transformer to panel, VCB panel to transformer etc. including Lightning Arrester Please Enable Macros to View BoQ information

Other Detail

Information Source https://eproc.punjab.gov.in
Download FileName File Description File Size
Download 625e020b-5abc-4c3d-ae1e-c8f9e804e0a5.html Tender Documents 0 KB
Download BOQ_329578.xls Tender Documents 0 KB
Download Tendernotice_1 (1).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.