Indian Tenders

Tender Notice

TDR 54386719
Tendering Authority Public Works Department
Tender No 15/2025-26/DMC
Tender ID 2026_DAMAN_4642_1
Tender Brief Tender For Supply And Comprehensive Operation And Maintenance Contract Of Street Light Poles At Various Places Of Daman Municipal Council, Daman.
City Daman
State Daman and Diu
Document Fees INR 10000 /-
EMD INR 138454.0 /-
Tender Value INR 55.38 Lakhs /-
Tender Type Works
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender For Supply And Comprehensive Operation And Maintenance Contract Of Street Light Poles At Various Places Of Daman Municipal Council, Daman.

Key Dates

Publish Date 03-03-2026
Last Date of Bid Submission 11-03-2026
Tender Opening Date 13-03-2026

Contact Information

Company Name Public Works Department
Contact Person Chief Officer, DMC
Address Daman Municipal Council, Fort Area, Moti Daman.

BOQ Items

Name of Work:- Supply and Comprehensive Operation and Maintenance contract of Street Light Poles at Various places of Daman Municipal Council, Daman.
Sl. No. Item Description
1Supplying and erecting LED street light / Flood light fittings with High power White LEDs wattage of 3 Watt and above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free High pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses, with toughened glass with company mark/name engraved or embossed 160 to 270 V,Power Factor more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45, Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %.( fittings required LM- 79 & LM-80 certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges shown.) (A) Street Light (IP-65), Surge protection -4KV integral and ,Light must have 440VAC line supply with over-voltage protection. (iv) above 90 to 120 watts Cat-III
2Providing & erecting 415V MCB Four Pole Switch for Lighting Load (B curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity (C) for 63 Amp. Cat.III
3ADD Extra for excavation in Semi hard rock (Murrum) by dry and wet blasting and chiselling for funnel type earthing of above.
4Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper cable 1.1 KV grade to be erected as directed of following size. (E) 3 core 2.5 Sq. mm.
5Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (B) 4 core 25 Sq. mm.
6(B) If additional machinery like hammer driller or JCB use [Add].
7Providing & laying approved make Double walled corrugated pipes (DWC) of polyethylene (B)63mm outer dia.
8Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following size . (C) 16/25 Sq.mm.
9Solder less crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner.(A) 1.5/2.5 to 6 Sq.mm.
10Supplying and erecting approved make Octagonal pole made from HR sheet steel. The pole should be made as per IS. and shall be coated with hotdip galvanizing as per IS2629/2633/4759, suitable suspend local wind speed with integral Junction box consist of terminal plate of min 6mm Hylam sheet, standard profile 35mmX7.5mm Din-Rail for MCB Mounting, stud type terminal and arrangement for cable termination to be erected as per details given by manufacturer considering site requirement.E)7Mtr.Long70mmTopX135mmbottomdia,3mmthicknesswith225mmX225mmX16mmbaseplate,4-M20Boltsand600mmlongJ-Bolt.ApproxPoleweight 67 kg.
11Providing 1:2:4 cement concrete foundation & 70 % PCC from bottom including excavation for the pole of size 60 x 60 x 150 cm. Deep in below ground level with plinth of 45 cm x 45 cm(or 45 cm dia x 45 cm) high upper ground level with necessary curing and finishing in approved manner.( for 9 & 10 mtr pole).
12Providing cement concrete.for foundation or for concrete filling in 1:2:4 ratio with 20 to 25 mm stone metal duly plastered with necessary curing for pole muffing or any other purpose.
13Providing and fixing Terminal board of size 5.0 x 127 x 152.4 mm.bakelite sheet with suitable brass studs with nuts, washers and clamps of size 25mm x 3mm suitable for pole.
14Supplying & erecting approved make SMC press moulded composite FRP. loop-in, loop- out approx. 2mm thick box complete with Bakelite connector strip 5way(3P+N+E),DIN rail for mounting mob & hinged doors as per requirement having locking arrangements with mounting clamp with nuts, bolts & washers suitable for erection on pole with cable clamps& earth bolt of following size of box. (A) 300mm x 200mm x 100mm [deep].
15Providing and erecting street light pole bracket comprising main B Class MS pipe of 4.2 cm/require outside dia. complete with suitable B Class M.S. sleeve tubing of approx. 45cms.length and suitable for 76.5 mm / 80mm. / require size pole top having sufficient fasteners for fixing the brackets and having spread of 1 mtr. length with suitable rise as per site condition & suitable welded stiffener reducer and nipple with check nut complete painted with one coat of Red oxide / PU base primer and two coats of Aluminium / PU paint. paint with following nos of arms. [A] Single Arm bracket 1.5 Mtr.
16Providing and erecting street light pole bracket comprising main B Class MS pipe of 4.2 cm/require outside dia. complete with suitable B Class M.S. sleeve tubing of approx. 45cms.length and suitable for 76.5 mm / 80mm. / require size pole top having sufficient fasteners for fixing the brackets and having spread of 1 mtr. length with suitable rise as per site condition & suitable welded stiffener reducer and nipple with check nut complete painted with one coat of Red oxide / PU base primer and two coats of Aluminium / PU paint. paint with following nos of arms [B] Double Arm Bracket 1.5 Mtr
17Supplying & erecting approved make Digital time switch having lithium cell 6 years operative and operate battery backup 1 channel day clock with 14 memory programme, suitable to operate on 240V + 5%, 16A with, floating contacts Minimum switching setup time 1 minimum & LCD display. Also comprised permanent ON/OFF switching. Programming switches & housed in fire proof thermoplastic enclosure & transparent cover erected as required with necessary connection erected as directed.
18Supplying & erecting power contactor ,AC3 duty for time switch complete erected as per direction Cat III , (D) 4 pole 440V 40 Amp.
19SITC of Galvanized Steel Flat 25x6 mm thickness from earth electrode directly in ground as required. Zinc coating: 500 g/m square (Approx:70 micron coating) tested and used exclusively for lightning protection earthing system and ring equipotential bonding.
20Dismantling the existing underground cable without damaging it with glands, cable end box including refilling the trench up to ground level and making coils complete to be placed at different store.
21Making trench in soft soil of suitable width of 90 cm deep for laying cable or locating the fault all over the run and back filling the same and making the surface as normal ground.+ B)If additional machinery like hammer driller or JCB use [Add].
22Making trench in Hard Murrum/Tar Road of suitable width of 90 cm or required depth for laying anysize of cable or locating the fault all over the run and backfilling the same and making the surface as normal ground. + B)If additional machinery like hammer driller or JCB use [Add].
23Charges for Re-Erecting approved make Octagonal pole made from HR sheet steel. The pole should be made as per IS. and shall be coated with hot dip galvanizing (E) 7 Mtr. Long 70 mm Top X 135 mm bottom dia, 3 mm thickness with 225mmX225mmX16mm base plate.
24Supplying & erecting XLPE(IS:7098) (I)-88 ISI unarmoured Aluminium cable 1.1 KV.grade to be erected as directed of following size. (C) 2 core 6 Sq. mm.
25Disconnecting the cable connection and Providing straight joint with PVC mould using heat shrink /cast resin type epoxy compound Insulating material and making the joint complete using necessary in line connectors, hardener, earth continuity connection, spacers etc. and reconnecting the same & ensure the joint resistance within the limits as per IS.(A) up to 25 Sq mm Cable.
26Comprehensive Operation and Maintenance Price Schedule for Street lighting system Providing of elctrician helper with exp of 5-6 years Providing and operation truck-mounted hydraulic boom lift for installation, inspection, repair and maintenance of street lighting systems, including all required manpower, fuel, tools and safety equipment.
27Comprehensive Operation and Maintenance Price Schedule for Street lighting system Maintanance of High Mast Pole (12.0 mt to 30.0 mt High) in DMC area.
28Comprehensive Operation and Maintenance Price Schedule for Street lighting system Providing of electrician with experience of 2-3 year
29Comprehensive Operation and Maintenance Price Schedule for Street lighting system Providing of elctrician helper with exp of 5-6 years Please Enable Macros to View BoQ information

Other Detail

Information Source http://ddtenders.gov.in/nicgep/app
Download FileName File Description File Size
Download Tendernotice_1.pdf Tender Documents 0 KB
Download 7556481d-e08c-40d1-acc5-07a4569b2d13.html Tender Documents 0 KB
Download BOQ_4818.xls Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.