Indian Tenders

Tender Notice

TDR 54386329
Tendering Authority Public Works Department
Tender No 89_EE_DNIeT_MECH_202526
Tender ID 2026_CEPWD_71189_1
Tender Brief Tender For Providing, Installation And Commissioning Of High Wall Split/ Window/Cassette/Floor Mounted Split Type Air Conditioning System As And When Urgently Required In Different Areas Of Agmc & Gbp Hospital For 01 (One) Year Period.
City Agartala
State Tripura
Document Fees INR 1000 /-
EMD INR 47235.0 /-
Tender Value INR 23.61 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Providing, Installation And Commissioning Of High Wall Split/ Window/Cassette/Floor Mounted Split Type Air Conditioning System As And When Urgently Required In Different Areas Of Agmc & Gbp Hospital For 01 (One) Year Period.

Key Dates

Publish Date 03-03-2026
Last Date of Bid Submission 18-03-2026
Tender Opening Date 18-03-2026

Contact Information

Company Name Public Works Department
Contact Person Execvutive Engineer
Address Executive Engineer Mechanical Division

BOQ Items

Name of Work:- Providing, Installation and commissioning of High wall Split/ Window/Cassette/Floor mounted Split type Air Conditioning system as and when urgently required in different areas of AGMC & GBP Hospital for 01 (One) year period.
Sl. No. Item Description
1Providing star rated (Minimum 3 star with applicable ISEER according to current industry standard) high wall split type AC machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specification with hermetically sealed compressor operating on non CFC refrigerant, pipe as supplied with AC machine, necessary plug top for IDU (With 01 year overall machine and compressor warranty) suitable for wall mounting conforming to IS 1391(Part-II) specification (Except power consumption) suitable for operation on 230 volt, 50 Hz, single phase AC supply capable of performing a) Cooling b) Dehumidifying c) Air circulating d) Filtering having rated cooling capacity.
21.0 TR high wall split type AC machine (Minimum rated cooling capacity should not be lsss than 3000 Kcal/hr or 12000 BThu/hr or 3500 watt).
31.5 TR high wall split type AC machine (Minimum rated cooling capacity should not be lsss than 4500 Kcal/hr or 18000 BThu/hr or 5250 watt).
42.0 TR high wall split type AC machine (Minimum rated cooling capacity should not be lsss than 6000 Kcal/hr or 24000 BThu/hr or 7000 watt).
51.5 TR window/ type AC machine (Minimum rated cooling capacity should not be lsss than 4500cal/hr or 18000 Thu/hr or 5250 watt)
6Providing 3 star rated (Minimum 3 star with applicabls ISEER accordlng to current industry standard) Ceiling mounted Cassette/ Floor mounted vertical Split type AC machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specification with hermetically sealed compressor operating on non CFC refrigerant, pipe as supplied with AC machine, necessary plug top for IDU (With 01 year overall machine and compressor warranty) suitable for wall mounting conforming to IS 1391(Part-II) specification (Except power consumption suitable for operation on 420 volt, 50 Hz, single phase AC supply capable of performing a) Cooling b) Dehumidifying c) Air circulating d) Filtering having rated cooling capacity.
73.0 TR Cassette type AC machine (Minimum rated cooling capacity should not be lsss than 9000 Kcl/hr ) or 36000 BThu/h or 10500 watt).
83.65 TR floor mounted vertical Split type AC machine (Minimum rated cooling capacity should not be lsss than 10950 Kcl/hr ) or 43800 BThu/h or 12775 watt).
9Standard installation, testing and commissioning of 1.0/1.5 / 2.0 TR high wall split type / window AC machine, including hole cutting, finishing etc. as per direction of the Engineer-in-charge.
10Standard installation, testing and commissioning of 3.0 TR ceiling mounted cassette type AC machine, including hole cutting, finishing etc. as per direction of the Engineer-in-charge.
11Standard installation, testing and commissioning of 3.65 TR floor mounted vertical Split type AC machine including hole cutting, finishing etc. as per direction of the Engineer-in-charge.
12Fabrication of M.S platform for placement of condensing unit by using M.S angle of (65x65x5) or (50x50x5) mm size base plate, nuts and bolts/ universal bracket (GSS) for ODU of split type ACs including all accessories for onsite installation i/c painting, fitting, fixing, grouting by cement mixture as per direction of the Engineer-in-charge.
13Fabrication of M.S platform of appropriate size, base plate, nuts and bolts/ universal bracket (GSS) for both IDU and ODU of 3.65 TR floor mounted vertical Split type ACs including all accessories for onsite installation i/c painting, fitting, fixing, grouting by cement mixture as per direction of the Engineer-in-charge.
14Supply, installation of additional length of copper pipe of appropriate size of (5/8\\" (15.88 mm), 1/4”(6.35 mm), 3/8” (9.53 mm) and 3/4”(19.05 mm) or nearest dia. as per manufacturer design for for both suction and liquid line with insulation and necessary wiring between indoor and outdoor units for 1.5 / 2.0 TR high wall type and 3.65 TR floor mounting vertical Split type ACs.
15Providing hard PVC pipe of best quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-charge. Please Enable Macros to View BoQ information

Other Detail

Information Source http://tripuratenders.gov.in
Download FileName File Description File Size
Download 65194713-6453-4ca8-a3e1-eb5993ab470c.html Tender Documents 0 KB
Download BOQ_72437.xls Tender Documents 0 KB
Download DNIeT.pdf Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB