Indian Tenders

Tender Notice

TDR 54377435
Tendering Authority Delhi University
Tender No CEET-7360
Tender ID 2026_DU_901103_1
Tender Brief Tender For Electrical Work To Be Carried Out In Reception, Library, Stack 1&2 ,Staircase At Faculty Of Management Studies, University Of Delhi
City Delhi
State Delhi
Document Fees INR 500 /-
EMD INR 16128.0 /-
Tender Value INR 8.06 Lakhs /-
Tender Type Works
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender For Electrical Work To Be Carried Out In Reception, Library, Stack 1&2 ,Staircase At Faculty Of Management Studies, University Of Delhi

Key Dates

Publish Date 03-03-2026
Last Date of Bid Submission 12-03-2026
Tender Opening Date 13-03-2026

Contact Information

Company Name Delhi University
Contact Person Executive Engineer
Address 12, Cavalry Lane, Engineering Department, University of Delhi, Delhi-110007

BOQ Items

Name of Work:- Electrical work to be carried out in Reception, Library, stack 1&2 ,Staircase at Faculty of Management Studies, University of Delhi
Sl. No. Item Description
1Supplying & fixing suitable size GI box with modularplate and cover in front on surface or in recessincluding providing and fixing 25 A modular socketoutlet and 25 A modular SP MCB, \\"C\\" curve includingconnections, painting etc. as required
2Supplying and fixing following modular switch/ socketon the existing modular plate & switch box includingconnections but excluding modular plate etc. as required
35/6 amps switch
43 pin 5/6 amps socket outlet
515/16 amps switch
66 pin 15/16 amp socket outlet
7Supplying and fixing two module stepped typeelectronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
8Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
925 mm
10Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required
116 Module (200mmX75mm)
128 Module (125mmX125mm
13Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthingthe point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C
14Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit asrequired.
151 x 1.5 sqmm
162 x 2.5 sqmm
172x 4 sqmm
182 x 6 sqmm
19Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V 50 HZ , Single phase AC supply , earthing etc complete as reqd
20Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
21Above 95 sqmm and upto 185 sqmm
22Upto 35 sqmm
23Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubiclepanel board including drilling holes in cubicle panel,making connections etc. as required
24400 A . 35 KA . TPMCCB
25Supply, Installation, testing and commissioning of pre-wired, single box fitting with one no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm complete i/c all accessories etc. directly on ceiling/wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. fitting equivalent to Philips Make, Cat No. TMC 502 1xT-LED 22W, Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I-2100lm
26Supply, Installation, testing and commissioning of pre-wired, Double box fitting with Two no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm complete i/c all accessories etc. directly on ceiling/wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. fitting equivalent to Philips Make, Cat No. TMC 502 2xT-LED 22W, Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I-2100lm
27Supply, Installation, testing and commissioning of pre-wired, 70 watt, Street Light luminaire delivering >100 lumen/watt with PDC housing, 220-240 V, 50 Hz on existig street light pole/wall including all accessories and connection etc.as required. Make Philips, Cat No. BRP032 P LED75 CW SLR PSU GR SPD or equivalent model of Thorn/Trilux
28Supply and fixing of street light pole box of size (250 X 200 X 100) complete with all necessary accessories including suitable clamps, bakelite sheet, brass screws, washers, and 01 no. 10 Amps SP MCB (Single Pole Miniature Circuit Breaker), inclusive of making electrical connections, as required at site.
29Supply, Installation, testing and commissioning of pre-wired, 45 watt, IP 65, Post top lantern light have symmetric light distribution, 220-240 V, 50 Hz complete i/c all accessories etc. directly on surface including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. Make Philips Uniscape Model, Cat No. BGP200 LED45 CW PSU GR CPC SPD or equivalent model of Thorn/Trilux
30Supplying of one number PVC insulated and PVC sheathed / XLPE aluminium conductor armoured power cable of 1.1 KV grade of size 4C X 16 sqmm etc as required.
314 x 16 sqmm
32Supply, installation , testing and commissioning of 1 HP , Direct on line starter with sheet steel enclosures suitable for 1-phase, 220V , complete set with contractor & OLR , start , stop push button with indicator lamps, voltmeter, ammeter, including mounting arragement of starter with all accesories etc. as required. Make Havells URJA- DOL submersible pump controller (Standard )- 1 Phase , Cat No. IHADOAJ1FD or equivalent model of crompton/BCH Electric
33Supply, Installation, testing and commissioning of one no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm in existing single box or double box fittings complete as required. Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I-2100lm
34Supplying , installation, testing and comissioning of 4 pin LED PLL tube 18 watt 1800 lm input voltage 220- 240 volt 50 Hz complete as required . Tube equivalent to philips Make Cat no. LED PLL 18W 6500K 2G11
35Supplying and Fixing of snap-on DLP trunking of size 105mm x 50 mm with cover and including accessories such as cover, Flat angle, end caps, internal/external angle support etc. on the wall/surface complete all as requied
36Supply, Installation, testing and commissioning of pre-wired, 150 watt, flood light Pressure die-cast aluminium housing with high impact resistance (IK07) glass cover IP66 protection, 130lm/w, 220-240 V, 50 Hz on existig street light pole/wall including all accessories and connection etc.as required..Philips Make, Cat No. BVP 192 LED 177 CW NB FG A1 PSU GR or equivalent model of Thorn/Trilux Please Enable Macros to View BoQ information

Other Detail

Information Source https://eprocure.gov.in/eprocure/app
Download FileName File Description File Size
Download a904ac2d-40ba-4ad2-8b20-c5d8b8ec5913.html Tender Documents 0 KB
Download BOQ_947147.xls Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.