Indian Tenders

Tender Notice

TDR 54372060
Tendering Authority Delhi Development Authority
Tender No 40/EE (E)/ELD-10/DDA/2025-26
Tender ID 2026_DDA_901105_1
Tender Brief Tender For Repair Maintenance Of Clear Water Booster Pump Sets,Compound/Street Lighting, D.G. Sets, Mechanical Ventilation , Lift Well Pressurization ,Common Area Lighting, Fire Alarm And Pa System And Fire Fighting System And Basement Storm Water Pumps E
City Delhi
State Delhi
Document Fees Refer document
EMD INR 97032.0 /-
Tender Value INR 48.51 Lakhs /-
Tender Type Works
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender For Repair Maintenance Of Clear Water Booster Pump Sets,Compound/Street Lighting, D.G. Sets, Mechanical Ventilation , Lift Well Pressurization ,Common Area Lighting, Fire Alarm And Pa System And Fire Fighting System And Basement Storm Water Pumps Etc. As Per Inventory And Terms & Conditions Attached. (I) Pump Operator-3No( 1No In Each Shift) (Ii) Khallasi-3 Nos (1No In Each Shift)) (Iii) Wireman-1No(10:00 Am To 6:00 Am & Whenever Requird). Note:- The Agency Shall Provide The Tower Wagon In The Contract Period For Maintenance Of Compound Lightings Of This Housing Within The Qouted Rate. No Extra Payment For The Same Will Be Entertained By This Division Office . , Providing Lift Operators For Rescue & Coordination With Johnson Of Lift As Per Inventory And Terms & Conditions Attached. (I) Multi Grade Operator Gr-Ii- 3 Nos (1No Round The Clock). Note:- The Agency Shall Arrange For Obtaining Noc From The Lift Inspector Of Delhi Govt. Payment Required To Be Deposited For Processing T

Key Dates

Publish Date 03-03-2026
Last Date of Bid Submission 11-03-2026
Tender Opening Date 12-03-2026

Contact Information

Company Name Delhi Development Authority
Contact Person EE(E)/ELD-10/DDA
Address EE(E)/ELD-10/DDA, B2B, Janakpuri, ND-58.

BOQ Items

Name of Work:-
Sl. No. Item Description
1RMO of clear water booster pump sets,compound/street lighting, D.G. sets, Mechanical ventilation , Lift well pressurization ,common area lighting, fire alarm and PA system and fire fighting system and basement storm water pumps etc. as per inventory and terms & conditions attached. (i) Pump Operator-3No( 1No in each Shift)(ii) Khallasi-3 Nos (1No in each Shift)) (iii) Wireman-1No(10:00 AM to 6:00 AM & whenever requird).Note:- The agency shall provide the Tower Wagon in the contract period for maintenance of compound lightings of this housing within the qouted rate. No extra payment for the same will be entertained by this division office .
2Providing lift operators for rescue & coordination with Johnson of lift as per inventory and terms & conditions attached. (i) Multi Grade Operator Gr-II- 3 Nos (1no round the clock). Note:- The agency shall arrange for obtaining NOC from the lift inspector of Delhi Govt. Payment required to be deposited for processing the case shall be borne by the Agency.
3Dismantling and repairing & rewinding i/c supply and replacement of following items of existing 3 phase of induction motor of existing make couple with 7.5 HP centrifugal pump i/c reassembly/reinstallation the same, connection, testing etc. completed as required:- Rewinding of 7.5 HP motor--- 1No
4S/R of bearing no 6307, 6308- 1 Set
5Connection plate - 1 No.
6Cooling Fan
7Labour Charges
8Repairing,Supply and replacement of following items of existing centrifugal pump make couple with 7.5 HP motor i/c reassembly/reinstallation the same, connection with suction and delivery line, valve testing etc. completed as required:- Neckering
9S/R of Distance bush
10Impeller plate & Ballancing
11S/R of Gland plate - 2 Nos
12S/R of Gland shaft
13Stuffing box Repair
14Labour charges for dismentling
15Servicing of 100 KVA DG set (Asok Leyland Make Engine Sr.NO- AL6CTIDG2)) Model No -CSH 17/100/TP i/c supply and replacement of following items:-(a) S/R of air Filter -1 Set.(b) S/R of diesel Filter -1 Set.(c) S/R of mobil filter- 1Set(e) S/R of Mobil oil/Engine Oil- 35 ltrs(f)S/R of set of starter -30 ltr (g)S/R of fuel pump i/c calibration and repairing of governor,nozzle pumps,injectors etc as required--1 Job (h) Labour charges for servicing - 1 Job Note:- Servicing of generators shall be got done through the OEM authorized dealer/service centre of the manufacturer only.
16Servicing of 50 KVA D.G. set (Asok Leyland Make Engine Sr.NO- AL4CTIDG2) Model No- CSH 17/50/TP i/c supply and replacement of following items:-(a) S/R of air Filter -1 Set.(b) S/R of diesel Filter -1 Set.(c) S/R of mobil filter- 1Set(e) S/R of Mobil oil/Engine Oil- 20 ltrs(f)S/R of set of starter -30 ltr (g)S/R of fuel pump i/c calibration and repairing of governor,nozzle pumps,injectors etc as required--1 Job (h) Labour charges for servicing - 1 Job Note:- Servicing of generators shall be got done through the OEM authorized dealer/service centre of the manufacturer only.
17Supply and replacement of following 40 Watt Post Top light having following technical specification and size as per attached GA drawing i/c testing etc complete as required at site:- (i)Spigot and Heat Sink Materials:-Aliminium PDC (ii)Top Cover Material:-Aluminium Spun Sheet (iii)Front cover :- Clear Acrylic (iv) LED :- LM 80 Certified LED (v) LED Lumen Maintanance:-50,000 hours@ L70 (vi) Diffusor/Lens:- Opal, PC diffusor (vii)Control Gear:- Isolated, Electronic,CC driver (viii) Hardware:- SS & MS Zinc plated and passivated (ix)Internal Wiring:-Insulated Cu wire (x)Ingress Protection:-IP65 (xi)Operating Voltage:-140V-270V (xii) Operating Temp:- -10-50 deg.celius. Note:- Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt
18Supply and replacement and fixing of following rating and breaking capacity and pole RCCB with module a suitable for 3 Phase,50 Hz 415 V AC i/c connection and testing etc .complete as required. (a) 100 A,300 mA, 2-Module
19Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz,Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim (i)15-16Watt
20Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C. (i) 150 Watt
21Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) ,SDCM(Standard Deviation Color Matching) <5,Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (i) 70Watt
22Supply and replacement of following accessories i/c testing etc complete as required at site. a) Indicating Lamp suitable for LT Panel (RED-15 Nos, Green-10nos & Yellow-5 Nos)
23(b)1.5 Sq.mm FRLS PVC insulated single core copper wire
24(c) 2.5 Sq.mm FRLS PVC insulated single core copper wire
25(d) Electric Timer Relay, ST3 Type ,Miniature Size
26Providing and fixing of Electrical insulting mat having following technical specification and size as complete as required at site :- (i) class-A- confirming to IS 15652 (ii) Size:- 2mmThick x 1mtr Width x10 mtr Length (iii) Antiskid design :- Dotted & Botttom textured(Black Colour) (iv) Warranty:- 12 Months against manufacturing defects only.
27Supply and replacement of 180 Ah lead acid battery duly charged complete with copper wires, terminals & thimbles etc suitable for 50KVA/100 KVA DG set complete as require at site.
28Supply and replacement of stored pressure MAP 50% (ABC dry chemical Powder) type Fire Extinguisher of capacity 6 kg confirms to IS 15683 bearing ISI marked complete with brass forged squeeze grip type valve fitted with pressure guage, pressurize with dry nitrogen gas filled, with discharge nozzle with wall mounting bracket, having fire rating of 3A & 21B complete as require at site.
29Supply and replacement of stored pressure MAP 50% (ABC dry chemical Powder) type Fire Extinguisher of capacity 9 kg confirms to IS 15683 bearing ISI marked complete with brass forged squeeze grip type valve fitted with pressure guage, pressurize with dry nitrogen gas filled, with discharge nozzle with wall mounting bracket, having fire rating of 3A & 21B complete as require at site.
30Supplying of High Speed Diesel for operation of DG set/Diesel engine i/c cartage, storage, filling and arrangement of minimum 200 ltrs capacity tank etc complete as required at site.
31Photoluminescent Signage 2 mm thick Aluminum Sheet(12 inch x 6 inch) Non Toxic non radio active maintenance free self-glowing exit sign or any other fire or emergency signs comprising zinc sulphide chargeable crystals which glow in dark printed on u-1000 photo-luminescent base chemical cover with u-v stabilized coating which glow in dark. a) Single Side---13 Nos
32(b) Double Side--- 13
33Repairing & Rewinding of 2Hp Sewage sub. pump set/ storm water pump sets/Weda Pump set (Three phase) of Kirloskar make i/c painting, connection, testing etc. complete as reqd follow:- i)Rewinding of motor, i/c approxy paint to rotor & stater - 1 Jobii) Supply and replacement of ball bearing upper & lower side ---- 2 Setsiii) Supply and replacement of mechanical seals upper and lower --- 2 Sets iv) 'O' Ring Set----- 1 Set v) Cable seal fitting with compound -- 1 Jobvi) Lubricant Oil --- 2 ltrs vii)Impeller Nut and key ---- 1 Set viii) Balancing of Impeller --- 1Job ix) Labour Charges for the dismentling, rewinding and repairing etc.
34Supply , Installation ,testing and commissioning of Digital Battery Charger(Auto Cut) suitable for charging battery upto 80Ah to 300Ah battery having following technical specification i/c connection ,testing etc complete as required at site. (i) Input Voltage-230-240V (ii) Output Voltage-12V (iii) Charging Capacity:- 80Ah to 300Ah (iv)Cut off Voltage:-14.5 V (v) current Rating-20A (Body Material:- Metal Please Enable Macros to View BoQ information

Other Detail

Information Source https://eprocure.gov.in/eprocure/app
Download FileName File Description File Size
Download 2ef8e4d5-582c-4124-b15c-52734cb45dcc.html Tender Documents 0 KB
Download BOQ_947156.xls Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Download Tendernotice_2.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.